Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Impact of Different Vein Catheter Sizes for Mechanical Power Injection in CT: In Vitro Evaluation with Use of a Circulation Phantom

The purpose of this study was to evaluate the influence of different peripheral vein catheter sizes on the injection pressure, flow rate, injection duration, and intravascular contrast enhancement. A flow phantom with a low-pressure venous compartment and a high-pressure arterial compartment simulating physiological circulation parameters was used. High-iodine-concentration contrast medium (370 mg iodine/ml; Ultravist 370) was administered in the venous compartment through peripheral vein catheters of different sizes (14, 16, 18, 20, 22, and 24 G) using a double-head power injector with a pressure limit of 325 psi. The flow rate was set to 5 ml/s, with a total iodine load of 36 g for all protocols. Serial CT scans at the level of the pulmonary artery and the ascending and the descending aorta replica were obtained. The true injection flow rate, injection pressure, injection duration, true contrast material volume, and pressure in the phantom during and after injection were continuously monitored. Time enhancement curves were computed and both pulmonary and aortic peak time and peak enhancement were determined. Using peripheral vein catheters with sizes of 14-20 G, flow rates of approximately 5 ml/s were obtained. During injection through a 22-G catheter the pressure limit was reached and the flow rate was decreased, with a consecutive decreased pulmonary and aortic contrast enhancement compared to the 14- to 20-G catheters. Injection through a 24-G peripheral vein catheter was not possible because of disconnection of the canula due to the high flow rate and pressure. In summary, intravenous catheters with sizes of 14-20 G are suitable for CT angiography using an injection protocol with a high flow rate and a high-iodine-concentration contrast medium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Liver Embolization with Four Different Spherical Embolic Materials: Impact on Inflammatory Tissue and Foreign Body Reaction

We sought to describe and compare material specific inflammatory and foreign body reactions after porcine liver embolization with spherical embolic agents. In 40 animals, superselective liver embolization was performed with four different spherical embolic agents of various sizes: 40-120 {mu}m (Embozene, Embosphere), and 100-300 {mu}m, 500-700 {mu}m, and 700-900 {mu}m (Embozene, Embosphere, Bead Block, and Contour SE, respectively). After 4 or 12 weeks, inflammatory reactions were evaluated microscopically according to the Banff 97 classification. For investigation of foreign body reactions, a newly designed giant cell score was applied. Banff 97 and giant cell scores closely correlated. At 4 weeks, small Embosphere particles (100-300 {mu}m) had a significantly higher Banff 97 score than Embozene, Bead Block, and Contour SE of the corresponding size. After 12 weeks, the calculated differences were not statistically significant. Comparison between the 4-week results and the 12-week results revealed a statistically higher Banff 97 score for Embosphere 100-300 {mu}m after 4 weeks than after 12 weeks (P = 0.02). The overall foreign body reaction was pronounced after embolization with smaller particles, especially in small Embosphere particles. Giant cell numbers with Embosphere 100-300 {mu}m were statistically higher compared with the other materials of corresponding size (P < 0.0001). Inflammatory and giant cell reactions after embolization procedures depend on the embolic material. The overall inflammatory reaction was low. However, marked inflammation was associated with small Embosphere particles at 4 weeks, a finding that might be caused by the allogeneic overcoat. Correspondingly, giant cells indicating a foreign body reaction were more frequently associated with small particle sizes, especially after embolization with small Embosphere particles.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uterine Artery Embolization Combined with Local Methotrexate and Systemic Methotrexate for Treatment of Cesarean Scar Pregnancy with Different Ultrasonographic Pattern

Purpose: This study was designed to compare the effectiveness of systemic methotrexate (MTX) with uterine artery embolization (UAE) combined with local MTX for the treatment of cesarean scar pregnancy (CSP) with different ultrasonographic pattern, and to indicate the preferable therapy in CSP patients. Methods: The results of 21 CSP cases were reviewed. All subjects were initially administrated with systemic MTX (50 mg/m{sup 2} body surface area). UAE combined with local MTX was added to the patients who had failed systemic MTX. The transvaginal ultrasonography data were retrospectively assessed, and two different ultrasonographic patterns were found: surface implantation and deep implantation of amniotic sac. The management and its effectiveness for patients with the two ultrasonographic patterns were studied retrospectively. Ultrasound scan and serum {beta}-hCG were monitored during follow-up. Data were analyzed with the Student's t test. Results: Nine patients were successfully treated with systemic MTX. The remaining 12 cases were successfully treated with additional UAE combined with local MTX. According to the classification by Vial et al. of CSP on ultrasonography, most surface implanted CSPs (8/11, 72.7%) could be successfully treated with systemic MTX, whereas most deeply implanted CSPs (9/10, 90%) had failed systemic MTX but still could be successfully treated with additional UAE combined with local MTX. All patients recovered without severe side effects. Most patients with a future desire for reproduction achieved subsequent pregnancy. Conclusions: For CSP patients suitable for nonsurgical treatment, UAE combined with local MTX would be the superior option compared with systemic MTX in the cases with deep implantation of amniotic sac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differences in Patient Characteristics and Midterm Outcome Between Asian and European Patients Treated with Radiofrequency Ablation for Hepatocellular Carcinoma

PurposeThe aim of this study was to compare patient characteristics and midterm outcomes after RFA for unresectable Hepatocellular carcinoma (HCC) in Asian and European cohorts.Materials and MethodsThe study was based on retrospective analysis of 279 patients (mean 64.8 ± 12.1 years; 208 males) treated with RFA for de novo HCC in tertiary referral centers in Singapore and the Netherlands, with median follow-up of 28.2 months (quartiles: 13.1–40.5 months). Cumulative incidence of recurrence and death were analyzed using a competing risk model.ResultsAge was higher in the Asian group: 66.5 versus 60.1 years (p < 0.0001). The most common etiology was hepatitis B in the Asian group (48.0 %) and alcohol-induced cirrhosis in Europeans (54.4 %); p < 0.001. Asian patients had less advanced disease: 35.5, 55.0, and 3.0 %, respectively, had BCLC 0, A, and B versus 21.5, 58.2, and 15.2 % in the European group (p = 0.01). The cumulative incidences of recurrence in the Asian group at 1, 2, 3, and 5 years were 37.0, 56.4, 62.3, and 67.7 %, respectively, compared to 32.6, 47.2, 49.7, and 53.4 % in the European group (p = 0.474). At 1, 2, 3, and 5 years, the cumulative incidence rates of death in the Asian group were 2.0, 3.9, 4.9, and 4.9 %, respectively, corresponding to 7.7, 9.2, 14.1, and 21.0 % in the European group (p = 0.155).ConclusionSimilar short-term treatment outcomes are achieved with RFA in HCC patients in the South-East Asian and Northern-European populations. Midterm recurrence and death rates differ between the groups as a result of differences in baseline patient characteristics and patient selection. Our study provides insight relevant to the design of future international studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Inversion (“flipping”) Rates Among Different Port Designs: A Single-Center Experience

PurposeTo compare incidence of port inversion among different types of implantable venous access devices.Materials and Methods Records of patients who underwent imaging-guided subcutaneous port placement without port fixation between July 2001 and April 2015 were reviewed with use of a quality assurance database. 1930 patients with complete follow-up (death or explant) were included in the study. Collected data included date and indication for port placement, port type, venous access site, immediate and long-term complications, indication for removal, and total number of catheter days. BMI of patients with inverted ports was also calculated.Results Port inversion within the pocket was observed in 18 patients (0.9%) including 7/82 (9%) of Dignity ports, 4/126 (3%) of Vaxcel plastic arm ports, 3/142 (2%) of Smartports, 2/100 (2%) of Powerports, 1/14 (7%) of Vaccess ports, and 1/1421 (0.07%) of Vortex LP ports. Among these designs, the inversion rate was significantly lower in Vortex LP ports (0.1%) (P < 0.05). There was a trend toward higher inversion rate of Dignity ports, which have a rectangular design with a relatively narrow base. Mean dwell in inverted ports was 114 days (7–580).Conclusion The incidence of port inversion without suture fixation of the port base to the pocket is extremely low. The present study shows differences in inversion incidence based on port design.Level of Evidence: Case Series, Level IV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microseismic Monitoring of Laboratory Hydraulic Fracturing Experiments in Granitic Rocks for Different Fracture Propagation Regimes

While hydraulic fracturing (HF) is a widely employed process, the underlying fracturing processes are still heavily contested. The attributes of the HF generated fracture network can exhibit substantial variation when dealing with specific HF propagation regimes encountered in the field. In this study, HF experiments were performed on true-triaxially loaded Barre granite cubes, with microseismic monitoring, to identify and characterize the fracturing mechanisms associated with different viscosity injection fluids. Utilizing fluids with high (oil/1450 cP) and low (water/1 cP) viscosity represented two key HF propagation regimes: viscosity- and toughness-dominated. The experiments conducted with oil involved higher breakdown pressures, larger fluid volumes, and slower fracture propagation speeds. Furthermore, the frequency–magnitude distribution (b value) for all experiments (1.9–2.3) was similar to those encountered for large-scale operations. Slightly larger b values were encountered during the initiation phase (2.4–2.7) relative to the fracture propagation and post-fracturing phases (1.9–2.2). Techniques such as polarity and moment-tensor inversion were utilized to characterize the source mechanisms. For the HF experiments with oil, tensile fractures were most dominant (92%) in the initiation phase compared to fracture propagation and post-fracturing phases (70–75%). Similar tensile fracturing dominancy was not observed with water, attributable to fluid permeation and leak-off. Regardless of the injection fluid or classification criteria employed, tensile fractures were the dominant type consistently, with fewer occurring in water experiments but the specific ratio of crack types varied with different source mechanism criteria employed.

58 GEOSCIENCES↗

Pyrolysis-Molecular Beam Mass Spectrometry to Characterize Soil Organic Matter Composition in Chemically Isolated Fractions from Differing Land Uses

Today's questions concerning the role of soil organic matter (SOM) in soil fertility, ecosystem functioning and global change can only be addressed through knowledge of the controls on SOM stabilization and their interactions. Pyrolysis molecular beam mass spectrometry (py-MBMS) provides a powerful and rapid means of assessing the biochemical composition of SOM. However, characterization of SOM composition alone is insufficient to predict its dynamic behavior. Chemical fractionation is frequently used to isolate more homogeneous SOM components, but the composition of fractions is frequently unknown. We characterized biochemical SOM composition in two previously studied soils from the USA, under contrasting land uses: cultivated agriculture and native vegetation. Bulk soils, as well as chemically isolated SOM fractions (humic acid, humin and non-acid hydrolysable), were analyzed using py-MBMS. Principal components analysis (PCA) showed distinct differences in the SOM composition of isolated fractions. Py-MBMS spectra and PCA loadings were dominated by low molecular weight fragments associated with peptides and other N-containing compounds. The py-MBMS spectra were similar for native whole-soil samples under different vegetation, while cultivation increased heterogeneity. An approach based on previously published data on marker signals also suggests the importance of peptides in distinguishing samples. While the approach described here represents significant progress in the characterization of changing SOM composition, a truly quantitative analysis will only be achieved using multiple internal standards and by correcting for inorganic interference during py-MBMS analysis. Overall, we have provided proof of principle that py-MBMS can be a powerful tool to understand the controls on SOM dynamics, and further method development is underway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trade-offs of different land and bioenergy policies on the path to achieving climate targets

Many papers have shown that bioenergy and land-use are potentially important elements in a strategy to limit anthropogenic climate change. But, significant expansion of bioenergy production can have a large terrestrial footprint. In this paper, we test the implications for land use, the global energy system, carbon cycle, and carbon prices of meeting a specific climate target, using a single fossil fuel and industrial sector policy instrument—the carbon tax, but with five alternative bioenergy and land-use policy architectures. We find that the policies we examined have differing effects on the different segments of the economy. Comprehensive land policies can reduce land-use change emissions, increasing allowable emissions in the energy system, but have implications for the cost of food. Bioenergy taxes and constraints, on the other hand, have little effect on food prices, but can result in increased carbon and energy prices.

54 ENVIRONMENTAL SCIENCES↗

Failure stress comparison of different pairings of Ag-plating and reflow-oven-processed pressureless-sintered-Ag interconnects

Here, sintered-silver is a candidate material to supplant solders for interconnects in power electronic packaging for many reasons including its desirably high electrical and thermal conductivities and compliance to Restriction of Hazardous Substances (RoHS) guidelines. The shear failure stress of interconnects though is limited by whatever constituent is the weakest, and that includes any employed plating. In the present study, silver-platings were processed electrolytically, electrolessly, and through sputter deposition and their influence on the entire “interconnect system” shear strength was examined. Test sets employing gold plating and no plating were included for comparison and to aid interpretation. Ambient-air, reflow-oven-processed, pressureless-sintered-silver interconnects were identically fabricated with all plating test sets. It was found that all considered silver-plating methods produced consistently strong (characteristic failure stresses > 55 MPa) sintered-silver interconnects. Because failures tended to be adhesive in all six sets, differences in failure stress among the silver-plated sets and the gold-plated or unplated sets were likely due to differences in the adhesive strength of the sintered silver with silver-plating, gold-plating, or direct bonding with copper.

36 MATERIALS SCIENCE↗

Chemical demineralization of different metamorphic grade coals

The paper analyzes a process of deep mineralization of various metamorphic grade coals pre-ground in different destructive units, namely, in centrifugal-planetary mill and disintegrator. Coal dispergation in higher energy intensive mills greatly enhances inorganic component extraction to acidic solutions. This is explained by distortion of crystal structure and amorphization of minerals under various kinds and different intensity mechanical actions.

01 COAL, LIGNITE, AND PEAT↗

Fastness Properties and Color Analysis of Natural Indigo Dye and Compatibility Study of Different Natural Reducing Agents

Conventional reduction process of indigo dyes with sodium dithionite produced lots of harmful byproducts and caused environmental pollution. A new reduction method should be introduced to textile dyer so that reduction can be less hazardous with low impact on the environment and energy resources. This study investigates an alternative reducing agent obtained from natural resources. Three different types of reducing agent are used, extracted from the Date palm, Banana and Apple by boiling method. To compare their effect on the reduction of the natural indigo dyestuff, different color fastness properties, pH and the color yield (K/S) were measured according to the concentration of reducing agent and hydrated lime concentration. Outcomes show that K/S value varies with the amount of reducing agent. Average higher value shows from date palm among the three reducing agents at 25 °C & pH range 10.8–11. By using natural reducing agents, it can be possible to get satisfactory colorfastness and depth of shed compared to a synthetic reducing agent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Magnetic Hysteresis Behaviors in a Mixed Spin (3/2, 2) Bilayer System with Different Crystal-Field Interactions

Dynamic magnetic hysteresis (DMH) behaviors of the mixed spin-3/2 and spin-2 Ising bilayer system with different crystal-field interactions on a two-layer square lattice is studied by the use of dynamic mean field calculations based on the Glauber-type stochastic. The hysteresis loops are obtained for different reduced temperatures (T), magnetic field amplitudes (h), frequencies (w) and interlayer coupling constants (J{sub 3}). Influences of the T, h, w and J{sub 3} on the DMH properties are investigated. We also study the temperature, frequency and interlayer coupling interaction dependence of the coercive field and remanent magnetization. We compare our results with some theoretical and experimental works and observe a quantitatively good agreement with some theoretical and experimental results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of FeSe Superconducting Tapes with Different Sheath Materials and Precursor Powders

FeSe superconducting tapes with different sheath materials of Nb/Cu composite, Ag, and Fe have been fabricated with a traditional in situ powder-in-tube (PIT) process, respectively. With the same cold working process and heat treatment, the influences of different sheath materials on the phase composition and microstructures of FeSe filaments have been analyzed. Due to the reaction between Nb-Se and Ag-Se, Nb{sub 2}Se and Ag{sub 2}Se particles can be clearly observed embedded in the filaments. Therefore, it is necessary to introduce a new method for the fabrication of Ag or Nb sheath FeSe wires in order to avoid the introduction of metal Fe in magnet system during practical applications. Based on our previous study, a high-energy ball milling process has been performed to achieve precursor powders with amorphous FeSe binary compound instead of elemental Se. The formation of Ag-Se compounds has been successfully avoided and the superconducting tapes with high superconducting FeSe critical temperature of 9.0 K have been obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparative Study on Microstructures, Magnetic Features and Morphologies of Ternary Fe–Co–Ni Alloy Thin Films Electrochemically Fabricated at Different Deposition Potentials

Electrochemically fabricated ternary Fe–Co–Ni alloy thin films with different chemical compositions were obtained at different deposition potentials. An increase in the deposition potential increased the Ni content while it decreased the Co and Fe contents in the film structure. An anomalous co-deposition behaviour was also studied and the anomalous order of co-deposition was found to be Fe–Ni > Co–Ni > Fe–Co irrespective of deposition potential. Structural characterizations confirmed the presence of single face-centred cubic (fcc) phase structure with [111] preferred crystallographic orientation for all films. The size of the crystallites and the texture degree increased with increasing applied deposition potential. Smaller globular particles occurred on the surface structure of the film fabricated at higher deposition potentials compared to those grown at lower deposition potentials. A decrement detected in the coercive field with increasing applied deposition potential was related to the variations occurred in the chemical composition and the particle size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of Fluxgate Sensors for Different Applications from Geology to Medicine

In this study, we have shown that fluxgate sensors can be used for different application areas. Alternative sensor configurations have been developed for three different application areas. These are mainly rod- and ring-type fluxgate sensors. In the first study, a measurement system with the rod-type fluxgate sensor has been developed in order to monitor the local magnetic field distributions on a magnetic tape (e.g., credit card). With this system, the magnetic recording data on the credit card were measured and imaged successfully. The second and the third application areas, which are monitoring the influence of solar storms on the earth field and heartbeat analysis of mankind, were carried out by using a ring-core fluxgate sensor geometry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Zn, Ga and Gd Doping on Structural and Magnetic Properties of Nanonickel Ferrite Prepared by Two Different Methods

Zn/Ga/Gd-substituted NiFe{sub 2}O{sub 4} was formed by solid state reaction and citrate methods. The influence of substitutions on phase formation, the strain, crystallize size, cations distribution and magnetic properties have been examined by X-ray diffraction, Mössbauer effect spectrometer, Fourier-transform infrared, and vibrating sample magnetometer. Zn/Ga/Gd substituted NiFe{sub 2}O{sub 4} samples prepared by solid state method showed that as gadolinium introduced into the system, a second phase was formed with a small percentage while samples prepared by citrate method exhibited a single phase. The distributions of different cations between different sites were determined by both Mössbauer effect spectroscopy, modified Bertaut and Rietveld analysis. Mössbauer technique at room temperature showed that samples synthesized by the ceramic method have a magnetic order while samples prepared by citrate method have a superparamagnetic nature. The canting angle between magnetic ions was increased by increased the amount of Zn in samples prepared by both methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Different Nano-sized MgO Addition on YBa{sub 2}Cu{sub 3}O{sub 7-δ} Superconductor

The effect of nanoparticle with different size on a superconductor is interesting because the size of the coherence length, penetration depth, and the magnetic flux in a superconductor is in the nanometer range. In this paper, we report the effects of different nano-sized MgO (20, 40, and 100 nm) addition on YBa{sub 2}Cu{sub 3}O{sub 7-δ}(MgO){sub x} for x = 0, 0.1, and 0.2 wt.%. X-ray diffraction patterns indicated a single YBa{sub 2}Cu{sub 3}O{sub 7} (YBCO) phase where the peaks were shifted to larger angles in the 20- and 40-nm MgO-added samples indicating induced stress of first order in the structure. The electrical resistance versus temperature was measured using the four-probe method. The transition temperature, T{sub c}, for the pure YBCO showed T{sub c} = 90 K and was suppressed to 78–80 K for the 20- and 40-nm MgO-added samples. AC susceptibility (χ = χ′ + iχ″) measurements showed a shift in the peak temperature, T{sub p}, of the imaginary susceptibility χ″ towards lower temperatures for 20-nm MgO-added samples but increased with larger MgO (100 nm). This work showed that smaller nano-sized MgO suppressed the superconducting properties of YBCO more compared with the larger MgO.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

32 Channel × 40 Gb/s WDM optical communication system utilizing different configurations of hybrid fiber amplifier

In this paper, a simulation analysis of 40 Gb/s wavelength division multiplexing system of 32 channels is implemented through RZ modulation format by using a different hybrid fiber amplifier (HFA) configurations, namely, serial HFA, parallel HFA, and combined serial–parallel hybrid fiber amplifier (CSP-HFA). The performance of the proposed amplifiers is compared in terms of average gain level, average noise figure, flat gain bandwidth. In addition, quality factor, bit error rate, and eye diagram for the demonstrated 32 channel × 40 Gb/s wavelength division multiplexing optical communication system utilizing different configurations of the hybrid fiber amplifier is compared. The CSP-HFA shows better performance than serial and parallel hybrid amplifiers in terms of wider flat gain bandwidth, higher quality factor, lower bit error rate, and wider and clearer eye opening. Furthermore, CSP-HFA exhibits a flat gain bandwidth of 65 nm with an acceptable average gain of 16 dB and average noise figure of 7 dB.

42 ENGINEERING↗