Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The Quickest, Lowest-cost Lunar Resource Assessment Program: Integrated High-tech Earth-based Astronomy

Science and technology applications for the Moon have not fully kept pace with technical advancements in sensor development and analytical information extraction capabilities. Appropriate unanswered questions for the Moon abound, but until recently there has been little motivation to link sophisticated technical capabilities with specific measurement and analysis projects. Over the last decade enormous technical progress has been made in the development of (1) CCD photometric array detectors; (2) visible to near-infrared imaging spectrometers; (3)infrared spectroscopy; (4) high-resolution dual-polarization radar imaging at 3.5, 12, and 70 cm; and equally important (5) data analysis and information extraction techniques using compact powerful computers. Parts of each of these have been tested separately, but there has been no programmatic effort to develop and optimize instruments to meet lunar science and resource assessment needs (e.g., specific wavelength range, resolution, etc.) nor to coordinate activities so that the symbiotic relation between different kinds of data can be fully realized. No single type of remotely acquired data completely characterizes the lunar environment, but there has been little opportunity for integration of diverse advanced sensor data for the Moon. Two examples of technology concepts for lunar measurements are given. Using VIS/near-IR spectroscopy, the mineral composition of surface material can be derived from visible and near-infrared radiation reflected from the surface. The surface and subsurface scattering properties of the Moon can be analyzed using radar backscattering imaging.

Pieters, Carle M.↗

Single-Photon-Sensitive HgCdTe Avalanche Photodiode Detector

The purpose of this program was to develop single-photon-sensitive short-wavelength infrared (SWIR) and mid-wavelength infrared (MWIR) avalanche photodiode (APD) receivers based on linear-mode HgCdTe APDs, for application by NASA in light detection and ranging (lidar) sensors. Linear-mode photon-counting APDs are desired for lidar because they have a shorter pixel dead time than Geiger APDs, and can detect sequential pulse returns from multiple objects that are closely spaced in range. Linear-mode APDs can also measure photon number, which Geiger APDs cannot, adding an extra dimension to lidar scene data for multi-photon returns. High-gain APDs with low multiplication noise are required for efficient linear-mode detection of single photons because of APD gain statistics -- a low-excess-noise APD will generate detectible current pulses from single photon input at a much higher rate of occurrence than will a noisy APD operated at the same average gain. MWIR and LWIR electron-avalanche HgCdTe APDs have been shown to operate in linear mode at high average avalanche gain (M > 1000) without excess multiplication noise (F = 1), and are therefore very good candidates for linear-mode photon counting. However, detectors fashioned from these narrow-bandgap alloys require aggressive cooling to control thermal dark current. Wider-bandgap SWIR HgCdTe APDs were investigated in this program as a strategy to reduce detector cooling requirements.

Huntington, Andrew↗

Intelligent Experiments through Real-Time AI: Fast Data Processing and Autonomous Detector Control for High-Energy Nuclear Experiments

The aim of this project is to develop software and hardware for fast real-time data processing and autonomous detector control and calibration for the sPHENIX and the future EIC experiments. Below summarizes Georgia Tech team efforts in the past year: 1. We developed a real-time clustering algorithm and FPGA-based pipeline architecture for processing fired pixel data from ALPIDE sensors in sPHENIX experiments. Our Columnar Clustering Co-Design introduces a hardware-aware, stream-friendly approach that segments pixel data by column pairs using a Column Pair Clustering (CPC) strategy, followed by Cluster Stitching to merge adjacent subclusters. Implemented in Vitis HLS, the pipeline comprises five stages—read-in, subclustering, stitching, analysis, and write-out—connected by tagged HLS streams with custom end-of-event signaling for robust synchronization. We designed a pipelined dataflow model optimized for throughput, low latency, and minimal buffering, enabling scalable clustering across events of arbitrary size. Our system maintains spatial precision via center-of-mass and shape key extraction and efficiently handles edge cases such as fragmented or nested clusters. Compared against DBSCAN in both software and hardware, our approach demonstrates competitive performance under FPGA constraints. 2. We also conducted a comprehensive algorithm-to-hardware co-design of connected component analysis tailored for sPHENIX experiments, focusing on real-time, low-latency processing using FPGAs and High-Level Synthesis (HLS). Starting from a Python-based particle tracking pipeline, the team translated the core logic—graph traversal via DFS and Union-Find—into an HLS-compatible C++ model, replacing dynamic memory and recursion with static arrays and pipelined control flow. The final design includes a fully streamed and dataflow-compatible Union-Find kernel optimized across five iterations, incorporating loop pipelining, array partitioning, AXI/FIFO interface tuning, and function flattening. Experimental results show up to 14.8× speedup over the CPU baseline, reducing per-graph latency to 1.58 μs and demonstrating strong resource efficiency with only ~7k LUTs and zero BRAM usage. The design maintains functional correctness against the Python reference using a Python-based C-simulation framework and Mean Squared Error metrics. This work validates the potential of HLS-driven FPGA designs for edge-level HEP data acquisition, laying a scalable foundation for future integration with real-time detector pipelines and multi-graph processing systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Airborne spectrograph for the thermal IR: Broadband Array Spectrograph System

Spectroscopic studies in the 'fingerprint' region of the thermal IR from 3 to 14 microns of celestial dust components and the overall energy distribution of the sources are best served by moderate spectral resolution (R = lambda/Delta lambda approximately 30 to 200), high sensitivity observations. Spectral purity and the reproducibility of the spectral shape are critical as well, when using the spectral shape to assign temperatures to dust grains or to gas clouds based on the wavelength and shape of molecular bands. These sensor attributes are also important to the use of wavelengths and ratios of solid state features to derive compositions of dust grains in celestial sources. The advent of high quality linear arrays of blocked impurity band (BIB) detectors of Si:As permitted the development of a state-of-the-art, patented, cooled prism spectrograph. Developed at The Aerospace Corporation largely with in-house funds, the Broadband Array Spectrograph System (BASS) has been used for a variety of remote sensing applications, but especially for IR astronomical studies on the Kuiper Airborne Observatory and at the NASA Infrared Telescope Facility (IRTF). The attributes of the spectrograph, specifically having the pupil imaged onto the 2 linear 58 element detector arrays so that the effects of guiding errors are minimized, being able to maximally exploit the limited observing time by acquiring all 116 spectral channels simultaneously, and having all spectral channels imaged through the same aperture so that spectral mapping is readily and reliably accomplished, afford the scientist with a unique opportunity to conduct both surveys of examples of many different types of sources as well as in-depth studies of a given class of object by thoroughly sampling the class members. This duality was demonstrated with the BASS through a combination of KAO flights where spectral maps were obtained as part of in-depth studies of specific source regions (such as Orion and W3) and flights where up to 21 legs/flight were used to survey many different sources of different types.

Russell, Ray W.↗

Albedo in the ATIC Experiment

ATIC(Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first 16-day flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2000. The ATIC flight collected approximately 25 million events. To measure charge of primary particle in presence of radiation scattered back from the interaction and subsequent shower development in the calorimeter a charge detector must be a mosaic of small detector pads so that the pad containing the signal from the incident particle has no additional signal from albedo particles. Therefore the silicon matrix was built of 4480 individual silicon pads each 2 cm x 1.5 cm. The matrix consists of four planes of detectors and the active detector area, in these planes are partially overlapped to completely cover the aperture. The lateral and amplitude distributions of albedo signals in Si-matrix are analyzed for different primary nuclei and different energy deposits in BGO calorimeter. The greater part of albedo signals has Q near 1, where Q = square root of Amplitude(MIP). The albedo distribution exponentially decreases up to Q near 8. These high values are produced by slow protons and plans. There are also a small number of signals of Q > 8, mainly for heavy nucleus primaries. These signals are apparently generated by neutrons. The comparison of the experimental data and simulations with GEANT 3-21 code using QGSM generator for nucleus-nucleus interactions is presented.

Sokolskaya, N. V.↗

Forward silicon vertex/tracking detector design and R$\&$D for the future Electron-Ion Collider

The proposed high-luminosity high-energy Electron-Ion Collider (EIC) will provide a clean environment to precisely study several fundamental questions in the fields of high-energy and nuclear physics . A low material budget and high granularity silicon vertex/tracking detector is critical to carry out a series of hadron and jet measurements at the future EIC especially for the heavy flavor product reconstruction or tagging. The conceptual design of a proposed forward silicon tracking detector with the pseudorapidity coverage from 1.2 to 3.5 has been developed in integration with different magnet options and the other EIC detector sub-systems. The tracking performance of this detector enables precise heavy flavor hadron and jet measurements in the hadron beam going direction. The detector R&D for the proposed silicon technology candidates: Low Gain Avalanche Diode (LGAD) and radiation hard depleted Monolithic Active Pixel Sensor (MALTA), which can provide good spatial and timing resolutions, is underway. Bench test results of the LGAD and MALTA prototype sensors will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The High Visible Resolution (HVR) instrument of the spot ground observation satellite

Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.

Otrio, G.↗

JWST Near-Infrared Detectors: Latest Test Results

The James Webb Space Telescope, an infrared-optimized space telescope being developed by NASA for launch in 2013, will utilize cutting-edge detector technology in its investigation of fundamental questions in astrophysics. JWST's near infrared spectrograph, NIRSpec utilizes two 2048 x 2048 HdCdTe arrays with Sidecar ASIC readout electronics developed by Teledyne to provide spectral coverage from 0.6 microns to 5 microns. We present recent test and calibration results for the NIRSpec flight arrays as well as data processing routines for noise reduction and cosmic ray rejection.

Smith, Erin C.↗

Observations of optical counterparts of Gamma-Ray bursts

This is a final report for a contract begun in Dec. 1987 and ended in Mar. 1989 to use the existing Lincoln Laboratory Experimental Test Site in Socorro, NM to search for optical counterparts to gamma-ray bursts. The objective was to develop an autonomous staring system to search for stationary, transient optical flashes. The search was to use an existing 31-inch telescope equipped with a sensitive video detector. The approach for the search was to develop real-time processing software to monitor the video signal from the detector and to record any transient, point-like flashes that occurred in the field of view. The system would have been able to detect fainter flashes (B is approximately 15(sup m) in 1/30 s, delta(m(sub v)) = 0.25(sup m)) than other systems but lacked a large field of view (only 1.2 deg diameter) necessary to give a high probability of detecting a random flash on the sky. As such, the plan was to monitor known gamma-ray burst error boxes and wait for a repetition of an earlier event. The high payoff of good sensitivity with high angular resolution (1 pixel = 10sec) and good time resolution (30 s) to allow post-burst searches warranted funding if the cost was not prohibitive. The contract began in the middle of the three-year cycle for High Energy Astrophysics Gamma-Ray Astronomy Research and Analysis Program. This final report briefly describes the portion of the plan completed under the original contract.

Knight, Frederick K.↗

Closeout Report of BNL LDRD 23-050 A Second EIC Detector: Physics Case and Conceptual Design

This document is the closeout report for LDRD 23-050, a type-A LDRD project awarded in FY2022 under the title “ A Second EIC Detector: Physics Case and Conceptual Design ”. The project was motivated by the strong interest within the EIC community in a second general-purpose detector and interaction region, and by the recognition that such a detector is essential to fully exploit the scientific potential of the EIC over its multi-decade lifetime. The key goals of the LDRD were to (i) strengthen the case for a second EIC detector, building on the arguments already articulated in the community Yellow Report, (ii) provide a realistic detector concept that is complementary to the current project detector, ePIC, in terms of physics reach, precision, and control of systematics, and (iii) broaden the overall physics program of the EIC facility. Since a possible second detector is expected to be realized with a delay of several years relative to the first detector, the project explicitly aimed at identifying technologies that are not yet sufficiently mature for ePIC but could be deployed on the later timescale of a second detector, thereby providing genuine complementarity and room for innovation. LDRD 23-050 provided support for two postdoctoral researchers and partial support for several BNL staff members, and the effort ramped up in mid-2023. Work was carried out in close collaboration with colleagues from the EIC project, the Cold QCD and STAR groups at BNL, and with substantial input from members of the EIC User Group and the ePIC Collaboration as reflected in the author list. Over the period from October 2022 through September 2025, this team developed and refined a physics program tailored to a second detector, translated the resulting physics requirements into detector-level performance targets, and explored multiple conceptual detector layouts capable of meeting these targets within the constraints of the second interaction region. The expected outcome, as stated in the original proposal, was a document detailing the physics potential and requirements of a second EIC detector, accompanied by a comprehensive conceptual detector design and an outline of the remaining R&D needed to bring the relevant technologies to maturity. The present report summarizes the progress that has been achieved toward these goals. It consolidates the physics studies, detector concepts, and technology assessments developed under this LDRD and places them in the broader context of worldwide detector R&D. While the evolving priorities of the EIC project and the substantial community effort required to design and construct ePIC naturally limited the scope of EIC-wide activities toward a second detector during this period, the work documented here is intended to provide a foundation and a point of reference for future efforts. Whatever form a second EIC detector may ultimately take, we hope that this report will serve as a useful guide for colleagues who continue to advance this program in the near- and mid-term future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

X-ray detector physics and applications; Proceedings of the Meeting, San Diego, CA, July 23, 24, 1992

Recent developments in X-ray and hard X-ray imaging detector, high-intensity sources, hard X-ray imaging optics, calibration, and detection technologies are discussed. Particular attention is given to a high-MTF X-ray image intensifier, application of monolithic CdZnTe linear solid state ionization detectors for X-ray imaging, magnetic response of high-Tc superconductors to X-ray radiation and detection of X-rays, laboratory soft X-ray source with foil target, detection of explosive materials using nuclear radiation, energy response of astronomical CCD X-ray detectors, calibration techniques for high-flux X-ray detectors, fabrication of grazing-incidence optics using flow-polishing techniques, and numerical simulations for capillary-based X-ray optics. (No individual items are abstracted in this volume)

Hoover, Richard B.↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

Scintillating Bubble Chambers for Direct Dark Matter Detection, and an Update on SBC-LAr10

The Scintillating Bubble Chamber (SBC) Collaboration aims to use the liquid-noble bubble chamber technology as a low-threshold detector for dark matter particles of 1-10 GeV/c2. The detector combines the remarkable electron recoil (ER) discrimination of the bubble chamber with the event-by-event energy resolution provided by liquid argon (LAr) scintillation, with the crucial added benefit that ER discrimination in liquid-noble bubble chambers extends to much lower thresholds than in past freon-filled bubble chambers, with the potential for quasi-background-free operation at thresholds of 100 eV in nuclear recoil (NR) energy. SBC has developed two functionally identical 10 kg detectors: SBC-LAr10 at Fermilab will calibrate low-threshold performance, while the radio-pure SBC-SNOLAB chamber will execute SBC s first deep-underground dark matter search. SBC-LAr10 at Fermilab was recently installed in the MINOS tunnel 100 meters underground, and the first bubbles are expected this fall. I will present the current status of SBC-LAr10 and describe the suite of gamma and neutron calibrations we will execute. The calibrations will confirm the physics reach of this new technology, motivating not just the SBC-SNOLAB chamber now being assembled but also future searches into the solar neutrino fog at 1 GeV/c2.

Sheng, Zhiheng↗

The "Puck" Energetic Charged Particle Detector: Design, Heritage, and Advancements

Energetic charged particle detectors characterize a portion of the plasma distribution function that plays critical roles in some physical processes, from carrying the currents in planetary ring currents to weathering the surfaces of planetary objects. For several low-resource missions in the past, the need was recognized for a low-resource but highly capable, mass-species-discriminating energetic particle sensor that could also obtain angular distributions without motors or mechanical articulation. This need led to the development of a compact Energetic Particle Detector (EPD), known as the "Puck" EPD (short for hockey puck), that is capable of determining the flux, angular distribution, and composition of incident ions between an energy range of approximately 10 kiloelectronvolts to several megaelectronvolts. This sensor makes simultaneous angular measurements of electron fluxes from the tens of kiloelectronvolts to about 1 megaelectronvolt. The same measurements can be extended down to approximately 1 kiloelectronvolt per nucleon,with some composition ambiguity. These sensors have a proven flight heritage record that includes missions such as MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) and New Horizons, with multiple sensors on each of Juno, Van Allen Probes, and Magnetospheric Multiscale. In this review paper we discuss the Puck EPD design, its heritage, unexpected results from these past missions and future advancements. We also discuss high-voltage anomalies that are thought to be associated with the use of curved foils, which is a new foil manufacturing processes utilized on recent Puck EPD designs. Finally, we discuss the important role Puck EPDs can potentially play in upcoming missions.

Clark, G.↗