Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Using an Automated Air Traffic Simulation Capability for a Parametric Study in Traffic Flow Management

Flight delays occur when demand for capacity-constrained airspace or airports exceeds predicted capacity. Demand for capacity-constrained airspace or airports can be controlled by a series of Traffic Management Initiatives (TMIs), which use departure and airborne delays, as well as pre-departure and airborne reroutes, to manage access to the constrained resources. Two systems exist in current and planned future operations to address imbalances between demand and capacity. The Collaborative Trajectory Options Program (CTOP) reduces demand to constrained resources by assigning strategic departure delay and pre-departure reroutes. Reroutes are selected from Trajectory Options Sets (TOSs) submitted by airlines. As flights approach the constrained resource, the Time-Based Flow Management System (TBFM) is used to assign tactical delay to satisfy constraints. This paper describes experiments performed to study the impact of varying levels of airline participation in CTOP via submission of TOSs on ground delay and flight time, and the impact of departure uncertainty on TBFM delays. Results suggest that as CTOP participation increases, average ground delays decrease for all airlines, but to the greatest extent for airlines participating in CTOP. A threshold in CTOP participation, which varies with the constraint capacity, is identified beyond which there is relatively little further reduction in average ground delays. Similarly, given the likely level of CTOP participation, the capacity reduction for which CTOP would be an appropriate TMI is also identified. Results also suggest that high average departure errors and high variability in departure error can make the prioritization of TBFM internal departures in TBFM metering and scheduling infeasible. Departure errors at current levels are, however, acceptable.

CTOP↗

Using an Automated Air Traffic Simulation Capability for a Parametric Study in Traffic Flow Management

Flight delays occur when demand for capacity-constrained airspace or airports exceeds predicted capacity. Demand for capacity-constrained airspace or airports can be controlled by a series of Traffic Management Initiatives (TMIs), which use departure and airborne delays, as well as pre-departure and airborne reroutes, to manage access to the constrained resources. Two systems exist in current and planned future operations to address imbalances between demand and capacity. The Collaborative Trajectory Options Program (CTOP) reduces demand to constrained resources by assigning strategic departure delay and pre-departure reroutes. Reroutes are selected from Trajectory Options Sets (TOSs) submitted by airlines. As flights approach the constrained resource, the Time-Based Flow Management System (TBFM) is used to assign tactical delay to satisfy constraints. This paper describes experiments performed to study the impact of varying levels of airline participation in CTOP via submission of TOSs on ground delay and flight time, and the impact of departure uncertainty on TBFM delays. Results suggest that as CTOP participation increases, average ground delays decrease for all airlines, but to the greatest extent for airlines participating in CTOP. A threshold in CTOP participation, which varies with the constraint capacity, is identified beyond which there is relatively little further reduction in average ground delays. Similarly, given the likely level of CTOP participation, the capacity reduction for which CTOP would be an appropriate TMI is also identified. Results also suggest that high average departure errors and high variability in departure error can make the prioritization of TBFM internal departures in TBFM metering and scheduling infeasible. Departure errors at current levels are, however, acceptable.

integrated demand management↗

Short-Lived Modules Need to be Efficient, Lightweight, and Circular for the Energy Transition

Deployment projections for decarbonizing the grid predict 1.75 TW of PV is needed in the United States by 2050. This entails a cumulative demand of 97 million metric tonnes of virgin materials for c-Si modules. These material needs are extraction and energy intensive, making them a key target for improving PV sustainability. Emerging PV technologies, such as perovskites, are targeting 15-year modules, high efficiencies, and circular designs. Previous analysis found that by just modifying the life expectancy to 15 years (keeping target c-Si efficiencies and BOM), an additional 1.4 TW of replacement modules are required to maintain capacity, increasing virgin material demand by 1.75x unless >95% closed-loop recycling is maintained. This study examines the effect of achieving higher efficiencies with thin-film designs and a 15-year expectancy. Higher efficiencies and thin film designs can decrease deployment and material demands, making the level of circularity more attainable. If BOM mass is reduced by 50%, closed-loop recycling rates need to be >80% to reduce virgin material demands compared to a 35-yr c-Si module. If module efficiencies are 30%, closed-loop recycling rates can be reduced to 65%. This efficiency increase also reflects that 1500 million fewer modules can be deployed, however, this is still 2000 million more modules than a 35-year module needs to deploy to achieve energy transition targets, and no PV technology is closed-loop recycled for all component materials.

circular economy↗

Variability of near-fault seismic risk to reinforced concrete buildings based on high-resolution physics-based ground motion simulations

Broadband physics-based simulated earthquake ground motions are utilized to characterize the regional-scale seismic risk to modern reinforced concrete (RC) structures. A highly dense dataset of ground motions covering a 100-km urn:x-wiley:00988847:media:eqe3413:eqe3413-math-0001 40-km domain was generated using kinematic fault rupture models with varying rupture characteristics to represent shallow crustal earthquakes and resolved up to frequencies of 5 Hz. Over 40,000 nonlinear response history simulations of short- and mid-rise RC special moment frame buildings were conducted using simulation models that are capable of representing nonlinear behavior and component deterioration effects. The spatial variability of structural risk within a single earthquake scenario and between different rupture scenarios is examined, and the regions of strongest directivity effects and highest structural demands are identified. The structural demands may vary by factor of up to 8.0 at very short distances from the fault, and the large dispersion in the demands decreases significantly beyond a distance of 15 km. The interstory drift and member rotation demands are substantially impacted by important features of the geological structure and the characteristics of the rupture scenarios, particularly the presence of localized high-slip regions. The frequency characteristics of the structures are found to play an important role in determining the effects of near-fault ground motions on the structural response and expected damage. The results of this study suggest that the simulated ground motions, particularly those generated using the hybrid rupture approach, may offer reasonable structural risk estimates for low-frequency structures and conservative estimates for high-frequency structures.

58 GEOSCIENCES↗

Exploring urban typologies using comprehensive analysis of transportation dynamics

Abstract As urban areas continue to expand and develop, categorizing cities into typologies offers a valuable framework for understanding metropolitan dynamics and fostering inter-city collaboration. However, existing typologies related to urban mobility have limitations, failing to consider cities within a single large urban region and often overlooking crucial dimensions such as trip demand and traffic flow. In this paper, we introduce a transportation-focused characterization for cities within a large urban region, specifically the San Francisco Bay Area, California. We incorporate over 40 metrics across five transportation dimensions: trip demand, road network, multi-modal network, traffic flow, and land use. Specifically, for the trip demand dimension, we include metrics capturing residents’ trip characteristics, such as mode share, intra-city trips, and inter-city trips. Additionally, we analyze the purpose of trips entering the city to gain a deeper understanding of incoming trip patterns. In the traffic flow dimension, we examine metrics like vehicle miles traveled, delay, and congestion to assess the traffic conditions on the street network. These, combined with other dimensions, provide a comprehensive view of a city’s transportation dynamics. Using unsupervised machine learning clustering methods, we identified eight distinct typologies for the Bay Area: Live Work Cities; Job and Activity Magnet Cities; Anchor Cities; Multi-modal Cities; Hyper-connected Cities; Low-density Residential Cities; Medium-density Residential Cities; and Mixed-use Residential Cities. Our findings show that many clusters are strongly influenced by trip demand and traffic flow metrics. Finally, we examine the practicality of this typology and its potential to guide collaborative transportation management strategies. The typologies provide a foundation for dialogue among Bay Area cities, focusing on evaluating shared characteristics and leveraging successes or challenges to develop unified strategies for transportation management.

Kuncheria, Anu↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Economic analysis of a nuclear hybrid energy system in a stochastic environment including wind turbines in an electricity grid

The electricity market in the U.S. is moving toward an energy mix including more variable renewable energy (VRE) sources like wind and solar. This increasing VRE penetration is altering the profile of the net electricity demand. Normally, flexible generators (e.g. gas turbines) are used to absorb fluctuations in the electricity demand. Therefore, an increase in VRE also leads to an increase in installed capacity for such flexible generators which, in turn, may increase the price of electricity. Nuclear-Renewable Hybrid Energy Systems (N-R HES) are seen as a solution to this problem. The N-R HES contains a nuclear power plant electrically and/or thermally linked to an industrial process (IP). This paper demonstrates a new methodology and presents the corresponding RAVEN/Modelica-based software framework to evaluate the financial performance of N-R HES. The novelty of the method is that it explicitly incorporates the stochastic nature of N-R HES inputs such as electricity demand and wind speeds. The method is applied to a generic (rather than region-specific) N-R HES. The analysis shows that under the right market conditions, economic benefits can be achieved by adding a suitable IP to the base-load generator. In particular, there exists an optimal relationship between the IP capacity and the demand. Furthermore, global trends indicate VRE penetration raises the cost of electricity due to the added volatility, an issue only mitigated when operating with high profit margins for the IP.

97 MATHEMATICS AND COMPUTING↗

Scalable probabilistic estimates of electric vehicle charging given observed driver behavior

To prepare for rapid growth in global electric vehicle adoption, grid and policy planners depend on detailed forecasts of future charging demand. In this paper we propose a novel holistic, scalable, probabilistic framework to produce large-scale estimates of electric vehicle charging load for long-term planning that capture real drivers’ charging patterns. Our framework captures the uncertainty and stochasticity in charging demand by taking a graphical modeling approach. It has three core elements: driver groups, charging segment choices, and charging session time and energy requirements. The framework uses hierarchical clustering to group drivers by their charging histories, capturing their heterogeneous behaviors and preferences across different segments or types of charging. The framework uses probabilistic mixture models for each driver group’s sessions to identify the unique charging behaviors observed within each segment. We illustrate its application with a large data set from California, profiling the charging patterns and unique driver clusters it identifies. Using the model knobs representing drivers’ battery capacities, behavior, and segment access we present scenarios for California’s charging demand in 2030 with 8 million passenger electric vehicles. Peak charging demand ranged from 3.3 to 8.7 GW across scenarios. Furthermore, each was calculated in under 45 s on a laptop computer.

33 ADVANCED PROPULSION SYSTEMS↗

Energy storage in combined gas-electric energy transitions models: The case of California

California’s vision for a net-zero future by 2045 relies heavily on variable renewable energy systems. Thus, energy storage - particularly long-duration storage - could play a fundamental role in reliably supplying low-carbon electricity. We study energy storage using the BRIDGES model, a combined gas-electric capacity expansion model for California across multiple investment periods (2025-2045), modeled with progressively decreasing carbon emission targets to a zero emissions by 2045. This least-cost optimization model includes renewable gas production via power-to-gas, long-term storage of energy in gaseous form, electric energy storage such as through batteries and hydrogen storage, and renewable energy generation, all with capacity tracking and investment. Multiple scenarios are evaluated to examine the sensitivity of the optimal storage portfolio to system-level and sector-level parameters. The scenario results show that all electric energy storage systems - which vary in storage duration - are deployed and required in a net-zero California in 2045, amounting to around 75 GW of storage capacity. Lithium ion systems make up approximately 80% of this power capacity and supply most short-run storage needs. Hydrogen storage - in the form of a power-to-gas-to-power system - emerges as a replacement to conventional natural gas storage, comprising most of the total energy storage capacity (~ 4 TWh). This capacity is less than 5% of the current natural gas storage capacity (94 TWh), indicating sufficient room for repurposing part of the gas infrastructure. A demand-side sensitivity analysis proves that higher electricity demand correlates with more builds of Li-ion batteries, while higher industrial heat demand leads to more builds of long-duration storage systems in a net-zero economy. Furthermore, power-to-gas systems satisfy part of the industrial heat demand by locally supplying renewable gas, which overtakes the traditional centralized gas storage and transfers through pipelines, casting significant doubts on the future of the large-scale gas infrastructure.

03 NATURAL GAS↗

Ten questions concerning reinforcement learning for building energy management

As buildings account for approximately 40% of global energy consumption and associated greenhouse gas emissions, their role in decarbonizing the power grid is crucial. The increased integration of variable energy sources, such as renewables, introduces uncertainties and unprecedented flexibilities, necessitating buildings to adapt their energy demand to enhance grid resiliency. Consequently, buildings must transition from passive energy consumers to active grid assets, providing demand flexibility and energy elasticity while maintaining occupant comfort and health. This fundamental shift demands advanced optimal control methods to manage escalating energy demand and avert power outages. Reinforcement learning (RL) emerges as a promising method to address these challenges. Here, in this paper, we explore ten questions related to the application of RL in buildings, specifically targeting flexible energy management. We consider the growing availability of data, advancements in machine learning algorithms, open-source tools, and the practical deployment aspects associated with software and hardware requirements. Our objective is to deliver a comprehensive introduction to RL, present an overview of existing research and accomplishments, underscore the challenges and opportunities, and propose potential future research directions to expedite the adoption of RL for building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Numerical modeling and parametric study of a dual purpose underground thermal battery

We report integrating thermal energy storage with building energy systems can enable flexible building electric demands at buildings to help mitigate the mismatch between electricity supply and demand. A novel building heating and cooling system that integrates a dual-source heat pump with hybrid thermal storage named dual-purpose underground thermal battery (DPUTB) has been developed for reshaping building electric demands. The proposed DPUTB integrated geothermal heat pump system is an original innovation that enables Grid-interactive Energy Efficient buildings. This paper focuses on the study of the novel DPUTB. The DPUTB works as both a thermal storage tank (an inner tank) and a ground heat exchanger (an outer tank separated from the inner tank by the insulation material). High fidelity and computationally effective models are needed to predict the performance of the novel DPUTB. This study has developed a simplified dynamic model for the DPUTB according to heat transfer and energy conservation principles and validated it by using experimental data obtained from testing a small-scale DPUTB apparatus. A parametric study was conducted to identify a design that can achieve the target thermal storage performance of load shift and energy efficiency. The parametric study results show that the inner tank shell thermal conductivity and the phase change material's melting point are the two most influencing factors on the performance of the DPUTB. One single full-size DPUTB with the identified design could provide 1-ton cooling (3.51 kW) with the supply temperature lower than 11 °C for 4 hours in summer after being fully charged in 8 hours. The inner tank filled with phase change material is for cooling thermal storage as a latent tank in the design. However, its capacity can be as high as 60 MJ as a sensible water tank for heating storage in winter. In the future study, the DPUTB model will be incorporated into the dual-source heat pump system for evaluating the overall system performance of demand side management in the long term.

25 ENERGY STORAGE↗

Solving the duck curve in a smart grid environment using a non-cooperative game theory and dynamic pricing profiles

With the intermittency that comes with electricity generation from renewables, utilizing dynamic pricing will encourage the demand-side to respond in a smart way that would minimize the electricity costs and flatten the net electricity demand curve. Determining the optimal dynamic pricing profile that would leverage distributed storage to flatten the curve is a novel idea that needs to be studied. Moreover, the economic feasibility of utilizing distributed electrical energy storage is still not given in the literature. Therefore, in this paper, a novel way of solving a citywide dynamic model using a bilevel programming algorithm is introduced. The problem is developed as a novel non-cooperative Stackelberg game that utilizes air-conditioning systems and electrical storage through the end-users to determine the optimal dynamic pricing profile. The results show that the combined effect of utilizing demand-side air-conditioning systems and distributed storage together can flatten the curve while employing the optimal dynamic pricing profile. An economic study is performed to determine the economic feasibility of 20 different cases with different battery designs and the level of solar penetration. Three metrics were used to evaluate the economic performance of each case: the levelized cost of storage, the levelized cost of energy, and the simple payback period. Most cases had levelized cost of storage values lower than 0.457 $/kWh, which is the lower bound available in the literature. Seven out of 16 cases have a simple payback period shorter than the lifetime of the system (25 years). The case with a 100 MW PV power plant and a battery storage of size 597 MWh, was found to be the most promising case with a simple payback period of 12.71 years for the photovoltaic plant and 19.86 years for the demand-side investments.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large-scale scenarios of electric vehicle charging with a data-driven model of control

Transportation electrification is forecast to bring millions of new electric vehicles to roads worldwide this decade. Planning to support those vehicles depends on detailed scenarios of their electricity demand in both uncontrolled and controlled or smart charging scenarios. In this work, we present a novel modeling approach to enable rapid generation of demand estimates that represent the impact of controlled charging for large-scale scenarios with millions of individual drivers. To model the effect of load modulation control on aggregate charging profiles, we propose a novel machine learning approach that replaces traditional optimization approaches. We demonstrate its performance modeling workplace charging control under a range of electricity rate schedules, achieving small errors (2.5%–4.5%) while accelerating computations by more than 4000 times. To generate the uncontrolled charging demand for scenarios with residential, workplace, and public charging we use statistical representations of a large data set of real charging sessions. We demonstrate the methodology by generating diverse sets of scenarios for California's charging demand in 2030 which consider multiple charging segments and controls, each run locally in under 50 s. We further demonstrate support for rate design by modeling the large-scale impact of a new, custom rate schedule for workplace charging.

33 ADVANCED PROPULSION SYSTEMS↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploring the potential of hydrogen in decarbonizing China's light-duty vehicle market

The Chinese government has pledged to achieve overall carbon neutrality by 2060. Currently, the transportation sector contributes to about 10% of total greenhouse gas (GHG) emissions in China. Hence, China has created a well-defined energy vehicle development strategy to reduce GHG emissions from the transportation sector, further expanding into hydrogen vehicle technologies. In this study, the Transportation Energy Analysis Model (TEAM) investigates the potential of hydrogen internal combustion engine vehicles (H2- ICEVs) and fuel cell vehicles (FCEVs) as a reliable pathway towards the government's aspiration of carbon neutrality in the transportation sector. According to TEAM, by adopting FCEVs and H2-ICEVs in the vehicle market, hydrogen demand could reach 25% of the total light-duty transportation energy demand in 2050. Consequently, this will lead to an annual reduction of more than 35 million tons GHG compared to only counting on the electrification pathway in the decarbonization task. Besides, FCEVs would take longer to penetrate the light-duty vehicle market compared to H2-ICEVs, as the current fuel cell technology still requires much improvement to attain a competitive vehicle cost of production.

Life cycle analysis↗