Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Copula-Based Flood Frequency Analysis at Ungauged Basin Confluences: Nashville, Tennessee

Many cities are located at or near the confluence of streams where availability of water resources may be enhanced to sustain user needs while also posing an increased flooding risk from multiple tributaries. An accurate flood frequency estimator that models the joint flood potential at a basin confluence is needed. Given that long-term flow observations are often unavailable, estimating flood frequency at ungaged basin confluences proves challenging. Through the use of copulas, this case study demonstrates how an improved flood frequency analysis can be performed for stream confluences at Nashville, TN. The approach involves four major steps including initial data quality control, fitting of marginal distributions of tributary peak flows, construction of a suitable dependence structure, and identification of flood frequency at the confluence point based on synthesized peak flows. This case study may help researchers and practitioners develop a better understanding of joint flood frequency with consideration of upstream dam regulation among several contributing watersheds.

54 ENVIRONMENTAL SCIENCES↗

The development of Thomson scattering system on HL-2A tokamak

A new Thomson scattering diagnostic system is successfully developed to measure core plasma electron temperature (T{sub e}) and density (n{sub e}) of HL-2A tokamak (major radius R=165 cm, minor radius a=40 cm). In this system, a standard lamp-monochromator combination is utilized for the calibration of spectral responses. By sweeping in the range of 750-1200 nm with a step of 2 nm, the work can be done automatically for one-point calibration and then for other. Electronic gain calibration and gain monitoring are done by pulsed light emitting diode light. By utilizing an intense Nd:YAG laser of pulse energy up to 4 J and employing good quality interference filters in the five-channel filter polychromator to surpress greatly the stray light, the TS system can be routinely used to make measurements with good quality data. After each HL-2A plasma discharge, the measured T{sub e} and n{sub e} data are transferred to HL-2A database for lookup and analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-barrier scattering of {sup 6}He and {sup 11}Be

Experiments on halo nuclei at energies around the Coulomb barrier can provide good quality data on elastic, inelastic, breakup and nucleon transfer reactions. This information turns out to be very important to understand the structure and dynamics of these exotic nuclei. In this work we present relevant results obtained from recent scattering experiments of {sup 11}Be and {sup 6}He on heavy targets at energies around the Coulomb barrier. Our data exhibit strong absorption effects in the elastic channel. The role played by transfer and breakup channels, and the coupling to the continuum, are studied using CDCC and DWBA calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absolute spectral radiance responsivity calibration of sun photometers

Sun photometers are designed to measure direct solar irradiance and diffused sky radiance for the purpose of atmospheric parameters characterization. A sun photometer is usually calibrated by using a lamp-illuminated integrating sphere source for its band-averaged radiance responsivity, which normally has an uncertainty of 3%-5% at present. Considering the calibration coefficients may also change with time, a regular high precision calibration is important to maintain data quality. In this paper, a tunable-laser-based facility for spectral radiance responsivity calibration has been developed at the Key Laboratory of Optical Calibration and Characterization, Chinese Academy of Sciences. A reference standard radiance radiometer, calibrated against cryogenic radiometer, is used to determine the radiance from a laser-illuminated integrating sphere source. Spectral radiance responsivity of CIMEL CE318-2 sun photometer is calibrated using this new calibration system with a combined standard uncertainty of about 0.8%. As a validation, the derived band-averaged radiance responsivity are compared to that from a Goddard Space Flight Center lamp-based sphere calibration and good agreements (difference <1.4%) are found from 675 to 1020 nm bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status of SPring-8 macromolecular crystallography beamlines

Seven beamlines are operated for macromolecular crystallography (MX) at SPring-8. The three undulator beamlines are developed for cutting edge target and four bending-magnet beamlines are developed for high throughput MX. The undulator beamline, BL41XU that provides the most brilliant beam, is dedicated to obtain high quality data even from small-size and weakly-diffracting crystals. The minimum beam size at sample position is achieved to 10 {mu}m diameter using a pin-hole collimator. Its photon flux at wavelength {lambda} = 1.0 A is 2.8x10{sup 11} photons/sec. This small beam coupled with irradiation point scanning method is quite useful to take diffraction dataset from small crystals by suppressing the radiation damage. These advanced technologies made a number of difficult protein structure analysis possible, (i.e. Sodium-potassium ATPase). The bending-magnet beamlines BL26B1/B2 and BL38B1 provide automatic data collection exploiting the high mobility of the beam. The beamline operation software 'BSS', sample auto-changer 'SPACE' and web-based data management software 'D-Cha' have made the automatic data collection possible. The 'Mail-in data collection system' that accepts distant users samples via courier service have made users possible to collect diffraction data without visiting SPring-8. The structural genomics research is promoted by these beamlines.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

MAST YAG Thomson scattering upgrade alignment system

The recent upgrade to the MAST YAG Thomson scattering while enhancing the diagnostic capabilities increased the complexity of the system. There are eight YAG lasers now operational, doubling the number from the previous setup. This means alignment between each laser individually and reference points is essential to guarantee data quality and diagnostic reliability. To address this issue an alignment system was recently installed. It mimics the beams alignment in MAST by sampling 1% of the laser beam that is sent into a telescope which demagnifies by a factor of 8. The demagnified beam is viewed with a CCD camera. By scanning the camera the profile and position of the beams in the scattering zone and in a range of several meters inside MAST can be determined. Therefore alignment is checked along the beam path without having to sample it inside the vessel. The experimental apparatus and test procedures are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Some (not so) Recent Results From Continuum Decay Spectroscopy

Recent technical advances have allowed for high-order multiparticle correlation experiments to be done. The first round of experiments done by our collaboration has lead to the highest quality data on the decay of {sup 6}Be(into an alpha particle and 2 protons), detailed how the continuum states of {sup 10}C decay (into 2 alphas and 2 protons) and lead to finding several previously unknown states in light nuclei and casting doubt on some states found by others.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and characterization of optical heads for interferometric ballistic velocity measurements

The design of optical fiber based heads offering high accuracy and bandwidth for use in VISAR (velocity interferometer system for any reflector) experiments measuring ballistic velocities is described. A new, expanded, model for predicting the distance-dependent collection efficiency of the heads is presented. The model is shown to agree very well with experimental results, both within and outside the ''depth of field''. Various optical heads are demonstrated, to suit different experimental setups and conditions. Designs offering options for high bandwidths, accurate prealignment, and large stand-off distances are discussed. Results from a typical VISAR experiment are presented, verifying that our designs yield high-quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase contrast tomography of the mouse cochlea at microfocus x-ray sources

We present phase contrast x-ray tomography of functional soft tissue within the bony cochlear capsule of mice, carried out at laboratory microfocus sources with well-matched source, detector, geometry, and reconstruction algorithms at spatial resolutions down to 2 μm. Contrast, data quality and resolution enable the visualization of thin membranes and nerve fibers as well as automated segmentation of surrounding bone. By complementing synchrotron radiation imaging techniques, a broad range of biomedical applications becomes possible as demonstrated for optogenetic cochlear implant research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ANTARES deep sea neutrino telescope results

The ANTARES experiment is currently the largest underwater neutrino telescope in the Northern Hemisphere. It is taking high quality data since 2007. Its main scientific goal is to search for high energy neutrinos that are expected from the acceleration of cosmic rays from astrophysical sources. This contribution reviews the status of the detector and presents several analyses carried out on atmospheric muons and neutrinos. For example it shows the results from the measurement of atmospheric muon neutrino spectrum and of atmospheric neutrino oscillation parameters as well as searches for neutrinos from steady cosmic point-like sources, for neutrinos from gamma ray bursts and for relativistic magnetic monopoles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A novel normalization scheme for laser-based plasma x-ray sources

A kHz repetition rate laser pump-X-ray probe system for ultrafast X-ray diffraction is set up based on a laser-driven plasma X-ray source. A simple and reliable normalization approach has been developed to minimize the impact of large X-ray pulse intensity fluctuation on data quality. It utilizes one single X-ray area detector to record both sample and reference signals simultaneously. Performance of this novel normalization method is demonstrated in reflectivity oscillation measurement of a superlattice sample at sub-ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Q-switched Ho:YAG laser assisted nanosecond time-resolved T-jump transient mid-IR absorbance spectroscopy with high sensitivity

Knowledge of dynamical structure of protein is an important clue to understand its biological function in vivo. Temperature-jump (T-jump) time-resolved transient mid-IR absorbance spectroscopy is a powerful tool in elucidating the protein dynamical structures and the folding/unfolding kinetics of proteins in solution. A home-built setup of T-jump time-resolved transient mid-IR absorbance spectroscopy with high sensitivity is developed, which is composed of a Q-switched Cr, Tm, Ho:YAG laser with an output wavelength at 2.09 μm as the T-jump heating source, and a continuous working CO laser tunable from 1580 to 1980 cm{sup −1} as the IR probe. The results demonstrate that this system has a sensitivity of 1 × 10{sup −4} ΔOD for a single wavelength detection, and 2 × 10{sup −4} ΔOD for spectral detection in amide I′ region, as well as a temporal resolution of 20 ns. Moreover, the data quality coming from the CO laser is comparable to the one using the commercial quantum cascade laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-array valence emission spectrometer (DAVES): A new approach for hard x-ray photon-in photon-out spectroscopies

CHESS has developed and successfully deployed a novel Dual Array Valence Emission Spectrometer (DAVES) for high energy resolution, hard x-ray spectroscopy. DAVES employs the simplest method for scanning multiple spherical crystals along a Rowland Circle. The new design achieves unique 2-color collection capability and is built to take special advantage of pixel array detectors. Our initial results show why these detectors greatly improve data quality. The presentation emphasizes flexibility of experimental design offered by DAVES. Prospects and benefits of 2-color spectroscopy are illustrated and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CO 2 laser heating system for in situ high pressure-temperature experiments at HPCAT

We present a CO 2 laser heating setup for synchrotron x-ray diffraction inside a diamond anvil cell, situated at HPCAT (Sector 16, Advanced Photon Source, Argonne National Lab, Illinois, USA), which is modular and portable between the HPCAT experiment hutches. Specifically, the system allows direct laser heating of wide bandgap insulating materials to thousands of degrees at static high pressures up to the Mbar regime. Alignment of the focused CO 2 laser spot is performed using a mid-infrared microscope, which addressed past difficulties with aligning the invisible radiation. The implementation of the mid-infrared microscope alongside a mirror pinhole spatial filter system allows precise alignment of the heating laser spot and optical pyrometry measurement location to the x-ray probe. A comparatively large heating spot (~50 μ m) relative to the x-ray beam (<10 μ m) reduces the risk of temperature gradients across the probed area. Each component of the heating system and its diagnostics have been designed with portability in mind and compatibility with the various experimental hutches at the HPCAT beamlines. We present measurements on ZrO 2 at 5.5 GPa which demonstrate the improved room-temperature diffraction data quality afforded by annealing with the CO 2 laser. We also present in situ measurements at 5.5 GPa up to 2800 K in which we do not observe the postulated fluorite ZrO 2 structure, in agreement with recent findings.

47 OTHER INSTRUMENTATION↗

The FIREBIRD-II CubeSat Mission (Focused Investigations of Relativistic Electron Burst Intensity, Range, and Dynamics)

FIREBIRD-II is a National Science Foundation funded CubeSat mission designed to study the scale size and energy spectrum of relativistic electron microbursts. The mission consists of two identical 1.5 U CubeSats in a low earth polar orbit, each with two solid state detectors that differ only in the size of their geometric factors and fields of view. Having two spacecraft in close orbit allows the scale size of microbursts to be investigated through the intra-spacecraft separation when microbursts are observed simultaneously on each unit. Each detector returns high cadence (10 s of ms) measurements of the electron population from 200 keV to >1 MeV across six energy channels. The energy channels were selected to fill a gap in the observations of the Heavy Ion Large Telescope instrument on the Solar, Anomalous, and Magnetospheric Particle Explorer. FIREBIRD-II has been in orbit for 5 years and continues to return high quality data. After the first month in orbit, the spacecraft had separated beyond the expected scale size of microbursts, so the focus has shifted toward conjunctions with other magnetospheric missions. FIREBIRD-II has addressed all of its primary science objectives, and its long lifetime and focus on conjunctions has enabled additional science beyond the scope of the original mission. This paper presents a brief history of the FIREBIRD mission’s science goals, followed by a description of the instrument and spacecraft. The data products are then discussed along with some caveats necessary for proper use of the data.

47 OTHER INSTRUMENTATION↗

A broadband wavelet implementation for rapid ultrasound pulse-echo time-of-flight measurements

A broadband wavelet approach to ultrasonic pulse-echo time-of-flight measurements is described. The broadband approach significantly reduces the time required for frequency-dependent pulse-echo measurements, enabling studies of dynamic systems ranging from biological systems to solid-state phase transitions. The described broadband approach is demonstrated in parallel with the more traditional frequency stepping approach to perform ultrasound time-of-flight measurements inside a large volume Paris-Edinburgh press in-situ at a synchrotron source. The broadband wavelet data acquisition process was found to be 1-2 orders of magnitude faster than the steppedfrequency approach, with no compromise in data quality or determined results.

47 OTHER INSTRUMENTATION↗