Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Preparation of fine-particles at cryogenic temperatures

Flash freezing process yields gelling agent for use at cryogenic temperatures. Vaporized material, diluted with an inert gas, is injected below the surface of an agitated cryogenic liquid. This method disperses particles of chlorine trifluoride in liquid oxygen difluoride.

Globus, H.↗

Submerged gas injector expels cryogenic liquids from tanks

Vaporizing small portion of cryogenic liquid into pressurizing gas reduces amount of pressurizing gas required to expel cryogenic liquid from tank. Specific example of injecting helium gas, stored at same temperature of liquid hydrogen, through submerged porous plate directly into liquid hydrogen is described.

Conrad, E. W.↗

Apollo 13 Mission: Cryogenic Oxygen Tank 2 Anomaly Report

There were two investigative aspects associated with the loss of the cryogenic oxygen tank pressure during the Apollo 13 flight. First, what was the cause of the flight failure of cryogenic oxygen tank 2. Second, what possible contributing factors during the ground history of the tank could have led to the ultimate failure in flight. The first flight indication of a problem occurred when the quantity measurement in the tank went full scale about 9 hours before the incident. This condition in itself could not have contributed to ignition in the tank, since the energy in the circuit is restricted to about 7 milli-joules. Data from the electrical system provided the second indication of a problem when the fans in tank 2 were activated to reduce any stratification which might have been present in the supercritical oxygen in the tank. Several short-circuits were detected and have been isolated to the fan circuits of tank 2. The first short-circuit could have contained as much as 160 joules of energy, which is within the current-protection level of the fan circuits. Tests have shown that two orders of magnitude less energy than this is sufficient to ignite the polytetrafluoroethylene insulation on the fan circuits in the tank. Consequently, the evidence indicates that the insulation on the fan wiring was ignited by the energy in the short-circuit.

Source record↗

Cryogenic insulation system Patent

Prefabricated multilayered self-evacuating insulation panels using gas with low vapor pressure at cryogenic temperatures for application to storage of cryogens

Perkins, P. J., Jr.↗

Overflow sensor for cryogenic-fluid vessels

Overflow sensor for cryogenic fluid vessels has been designed by winding electrical resistance element on porous tubular coil form. Form is positioned in overflow vent of cryogenic fluid vessel where it can differentiate vapor from liquid at same temperature.

Tener, W. M.↗

Filament-wound, fiberglass cryogenic tank supports

The design, fabrication, and testing of filament-wound, fiberglass cryogenic tank supports for a LH2 tank, a LF2/FLOX tank and a CH4 tank. These supports consist of filament-wound fiberglass tubes with titanium end fittings. These units were satisfactorily tested at cryogenic temperatures, thereby offering a design that can be reliably and economically produced in large or small quantities. The basic design concept is applicable to any situation where strong, lightweight axial load members are desired.

Carter, J. S.↗

Passive retention/expulsion methods for subcritical storage of cryogens: Test plan, subscale dual-screen-liner retention/expulsion system

A test program is described to demonstrate liquid-free gas venting of a subcritically stored cryogen using a passive retention/expulsion system. The test plan is specifically aimed at verifying this capability for the dual-screen-liner concept, independent of gravity level and direction. In addition, the test is designed to yield operational characteristics data for the dual-screen-liner, including: tank filling, frequency and duration of venting, cryogen temperature and pressure histories, sensitivity of pressure relief control, and the ability of the passive device to provide communication between the vapor annulus and bulk regions. Normal l-g aircraft and drop tower tests using nitrogen as the test liquid are discussed.

Hise, R. E.↗

Cryogen acquisition in orbit

Orbital cryogen acquisition is a definite requirement for engine restart and/or propellant transfer on all major future missions. The most promising methods, especially for large scale vehicles, are acquisition by linear acceleration and acquisition by capillary systems. Intermittent acceleration and propellant settling requires some state-of-the-art extension since it has not been attempted on a large scale cryogen vehicle. Capillary acquisition systems offer the advantages of reusability, passiveness, low weight, and mission flexibility. The major disadvantage is that of an undeveloped technology. The method does not lend itself to verification through ground testing.

Hastings, L. J.↗

Modified Apollo cryogenic oxygen tank design

Assessment of the Apollo 13 mission indicated that some design changes to be incorporated into Apollo cryogenic oxygen storage tanks. These changes broadly fit into three categories. They were: (1) deletion of the fluid equilibration motors and redesign of heater assembly, (2) material changes for internal tank wiring and density sensor, and (3) the addition of a heater assembly temperature sensor. Development of a cryogenic oxygen tank incorporating these changes is presented.

Vanleuven, K.↗

The cryogenics analysis program for Apollo mission planning and analysis

The cryogenics analysis program was developed as a simplified tool for use in premission planning operations for the Apollo command service module. Through a dynamic development effort, the program has been extended to include real time and postflight analysis capabilities with nominal and contingency planning features. The technical aspects of the program and a comparison of ground test and mission data with data generated by using the cryogenics analysis program are presented. The results of the program capability to predict flight requirements also are presented. Comparisons of data from the program with data from flight results, from a tank qualifications program, and from various system anomalies that have been encountered are discussed. Future plans and additional considerations for the program also are included. Among these plans are a three tank management scheme for hydrogen, venting profile generation for Skylab, and a capability for handling two gas atmospheres. The plan for two gas atmospheres will involve the addition of the capability to handle nitrogen as well as oxygen and hydrogen.

Scott, W.↗

A review of cryogenic testing performed by the thermochemical test branch, Manned Spacecraft Center in support of Apollo 13 and14

The Apollo 13 anomaly provided considerable impetus for a variety of types of cryogenic and ignition tests. The logic of the various test program designs, the test techniques, and their final impact upon the investigation findings are described. In addition, several test programs initiated to determine the thermal performance and general performance characteristics of the redesigned Apollo 14 cryogenic storage system are presented.

Propp, C. E.↗

Thermal modeling of a cryogenic turbopump for space shuttle applications.

Thermal modeling of a cryogenic pump and a hot-gas turbine in a turbopump assembly proposed for the Space Shuttle is described in this paper. A model, developed by identifying the heat-transfer regimes and incorporating their dependencies into a turbopump system model, included heat transfer for two-phase cryogen, hot-gas (200 R) impingement on turbine blades, gas impingement on rotating disks and parallel plate fluid flow. The ?thermal analyzer' program employed to develop this model was the TRW Systems Improved Numerical Differencing Analyzer (SINDA). This program uses finite differencing with lumped parameter representation for each node. Also discussed are model development, simulations of turbopump startup/shutdown operations, and the effects of varying turbopump parameters on the thermal performance.

Knowles, P. J.↗

Thermal/structural optimization of cryogenic storage systems.

An analytical method has been developed to optimize a cryogenic storage system designed for long term storage of cryogenic propellants. The type of propellant, mission duration, thermal environment, insulation thermal properties, insulation vent time, and the storage system weight penalty imposed by the design pressure were considered as the dependent parameters. The optimum system insulation thickness and vent pressure were then calculated in terms of these parameters. The method was applied to the design of the Space Shuttle Orbiter oxygen and hydrogen tanks to obtain an optimum design. It was determined that for the mission examined, the hydrogen tank optimum design was close to the initial pressure. A continuously vented hydrogen tank, therefore, was close to the optimum design. Also, it was determined that for this particular mission the oxygen tank should not be vented.

Navickas, J.↗

Low thermal flux glass-fiber tubing for cryogenic service.

Study of thin metallic liners which provide leak-free service in cryogenic propulsion plumbing systems and are overwrapped with a glass-fiber composite that provides strength and protection from handling damage. The composite tube is lightweight, strong, and has a very low thermal flux. The resultant reduced boiloff of stored cryogenic propellants yields a substantial weight savings for long-term missions (seven days or greater). Twelve styles of tubing ranging from 1/2 to 5 in. in diameter were fabricated and tested with excellent results for most of the concepts at operating temperatures from +70 to -423 F and operating pressures up to 3000 psi.

Hall, C. A.↗

Static and dynamic fatigue behavior of glass filament-wound pressure vessels at ambient and cryogenic temperatures.

Investigation of the pressure load carrying capacity and fatigue strength of filament-wound glass-reinforced plastic pressure vessels subjected to static and cyclic loading at ambient and cryogenic (liquid nitrogen) temperature environments. The results indicate that the static fatigue problem is not critical at cryogenic temperatures. Under static loading at liquid nitrogen temperature, a reinforced plastic cylinder sustained pressurization for 88 days without failure at about 90% of the single cycle burst strength. At ambient temperature, the static life at 90% of the burst strength was about 7 min. Under cyclic loading in liquid nitrogen, no failure resulted after 1509 cycles at 55% of the single cycle burst strength. Under the same cyclic loading at ambient temperature, the test results would predict failure in the reinforced plastic. The results of similar tests upon adhesively bonded polyimide aluminum-foil lined cylinders are also reviewed.-

Hanson, M. P.↗

Fracture and crack growth resistance studies of 304 stainless steel weldments relating to retesting of cryogenic vessels

Fracture and crack growth resistance characteristics of 304 stainless steel alloy weldments as relating to retesting of cryogenic vessels were examined. Welding procedures were typical of those used in full scale vessel fabrication. Fracture resistance survey tests were conducted in room temperature air, liquid nitrogen and liquid hydrogen. In air, both surface-flawed and center-cracked panels containing cracks in weld metal, fusion line, heat-affected zone, or parent metal were tested. In liquid nitrogen and liquid hydrogen, tests were conducted using center-cracked panels containing weld centerline cracks. Load-unload, sustained load, and cyclic load tests were performed in air or hydrogen gas, liquid nitrogen, and liquid hydrogen using surface-flawed specimens containing weld centerline cracks. Results were used to evaluate the effectiveness of periodic proof overloads in assuring safe and reliable operation of over-the-road cryogenic dewars.

Hall, L. R.↗