Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Initial Report of Pencil Beam Scanning Proton Therapy for Posthysterectomy Patients With Gynecologic Cancer

Purpose: To report the acute toxicities associated with pencil beam scanning proton beam radiation therapy (PBS) for whole pelvis radiation therapy in women with gynecologic cancers and the results of a dosimetric comparison of PBS versus intensity modulated radiation therapy (IMRT) plans. Methods and Materials: Eleven patients with posthysterectomy gynecologic cancer received PBS to the whole pelvis. The patients received a dose of 45 to 50.4 Gy relative biological effectiveness (RBE) in 1.8 Gy (RBE) daily fractions. Acute toxicity was scored according to the Common Terminology Criteria for Adverse Events, version 4. A dosimetric comparison between a 2-field posterior oblique beam PBS and an IMRT plan was conducted. The Wilcoxon signed rank test was used to assess the potential dosimetric differences between the 2 plans and PBS target coverage robustness relative to setup uncertainties. Results: The median patient age was 55 years (range 23-76). The primary site was cervical in 7, vaginal in 1, and endometrial in 3. Of the 11 patients, 7 received concurrent cisplatin, 1 each received sandwich carboplatin and paclitaxel chemotherapy, both sandwich and concurrent chemotherapy, and concurrent and adjuvant chemotherapy, and 1 received no chemotherapy. All patients completed treatment. Of the 9 patients who received concurrent chemotherapy, the rate of grade 2 and 3 hematologic toxicities was 33% and 11%, respectively. One patient (9%) developed grade 3 acute gastrointestinal toxicity; no patient developed grade ≥3 genitourinary toxicity. The volume of pelvic bone marrow, bladder, and small bowel receiving 10 to 30 Gy was significantly lower with PBS than with intensity modulated radiation therapy (P<.001). The target coverage for all PBS plans was robust relative to the setup uncertainties (P>.05) with the clinical target volume mean dose percentage received by 95% and 98% of the target volume coverage changes within 2% for the individual plans. Conclusions: Our results have demonstrated the clinical feasibility of PBS and the dosimetric advantages, especially for the low-dose sparing of normal tissues in the pelvis with the target robustness maintained relative to the setup uncertainties. Future studies with larger patient numbers are planned to further validate our preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Patterns of Ipsilateral Supraclavicular Nodal Metastases in Breast Cancer: Rethinking the Clinical Target Volume for High-risk Patients

Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. A modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Report of a Prospective Dosimetric and Clinical Feasibility Trial Demonstrates the Potential of Protons to Increase the Therapeutic Ratio in Breast Cancer Compared With Photons

Purpose: To compare dosimetric endpoints between proton therapy (PT) and conventional radiation and determine the feasibility of PT for regional nodal irradiation (RNI) in women with breast cancer. Methods and Materials: From 2012 to 2014, 18 women (stage IIA-IIIB) requiring RNI prospectively enrolled on a pilot study. Median age was 51.8 years (range, 42-73 years). The cohort included breast-conserving therapy (BCT) and mastectomy patients and right- and left-sided cancers. Treatment targets and organs at risk were delineated on computed tomography scans, and PT and conventional plans were developed. Toxicity was prospectively recorded using Common Terminology Criteria for Adverse Events version 4.0. A Wilcoxon signed-rank sum test compared the dose-volume parameters. The primary endpoint was a reduction in cardiac V5. Results: Median follow-up was 20 months (range, 2-31 months). For all patients, the PT plan better met the dosimetric goals and was used for treatment. Proton therapy alone was used for 10 patients (9 postmastectomy, 1 after BCT) and combined proton–photon in 8 (6 BCT, 2 postmastectomy with immediate expander reconstruction). Proton therapy improved coverage of level 2 axilla (P=.0005). Adequate coverage of internal mammary nodes was consistently achieved with PT (median D95, 50.3 Gy; range, 46.6-52.1 Gy) but not with conventional radiation therapy (median D95, 48.2 Gy; range, 40.8-55 Gy; P=.0005). Median cardiac V5 was 0.6% with PT and 16.3% with conventional radiation (P<.0001). Median ipsilateral lung V5 and V20 were improved with PT (median V5 35.3% vs 60.5% [P<.0001]; and median V20, 21.6% vs 35.5% [P<.0001]). Grade 3 dermatitis developed in 4 patients (22%), which was the only grade 3 toxicity. No grade 4+ toxicities developed. Conclusion: Proton therapy for RNI after mastectomy or BCT significantly improves cardiac dose, especially for left-sided patients, and lung V5 and V20 in all patients without excessive acute toxicity. Proton therapy simultaneously improves target coverage for the internal mammary nodes and level 2 axilla, which may positively impact long-term survival in breast cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer

Purpose: The purpose of this study was to compare the impact of uncertainties and interplay on 3-dimensional (3D) and 4D robustly optimized intensity modulated proton therapy (IMPT) plans for lung cancer in an exploratory methodology study. Methods and Materials: IMPT plans were created for 11 nonrandomly selected non-small cell lung cancer (NSCLC) cases: 3D robustly optimized plans on average CTs with internal gross tumor volume density overridden to irradiate internal target volume, and 4D robustly optimized plans on 4D computed tomography (CT) to irradiate clinical target volume (CTV). Regular fractionation (66 Gy [relative biological effectiveness; RBE] in 33 fractions) was considered. In 4D optimization, the CTV of individual phases received nonuniform doses to achieve a uniform cumulative dose. The root-mean-square dose-volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under the RVH curve (AUCs) were used to evaluate plan robustness. Dose evaluation software modeled time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Dose-volume histogram (DVH) indices comparing CTV coverage, homogeneity, and normal tissue sparing were evaluated using Wilcoxon signed rank test. Results: 4D robust optimization plans led to smaller AUC for CTV (14.26 vs 18.61, respectively; P=.001), better CTV coverage (Gy [RBE]) (D{sub 95%} CTV: 60.6 vs 55.2, respectively; P=.001), and better CTV homogeneity (D{sub 5%}-D{sub 95%} CTV: 10.3 vs 17.7, resspectively; P=.002) in the face of uncertainties. With interplay effect considered, 4D robust optimization produced plans with better target coverage (D{sub 95%} CTV: 64.5 vs 63.8, respectively; P=.0068), comparable target homogeneity, and comparable normal tissue protection. The benefits from 4D robust optimization were most obvious for the 2 typical stage III lung cancer patients. Conclusions: Our exploratory methodology study showed that, compared to 3D robust optimization, 4D robust optimization produced significantly more robust and interplay-effect-resistant plans for targets with comparable dose distributions for normal tissues. A further study with a larger and more realistic patient population is warranted to generalize the conclusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Validation of a High Dimensional Shape Model for Organ Motion in Intact Cervical Cancer

Purpose: Validated models are needed to justify strategies to define planning target volumes (PTVs) for intact cervical cancer used in clinical practice. Our objective was to independently validate a previously published shape model, using data collected prospectively from clinical trials. Methods and Materials: We analyzed 42 patients with intact cervical cancer treated with daily fractionated pelvic intensity modulated radiation therapy and concurrent chemotherapy in one of 2 prospective clinical trials. We collected online cone beam computed tomography (CBCT) scans before each fraction. Clinical target volume (CTV) structures from the planning computed tomography scan were cast onto each CBCT scan after rigid registration and manually redrawn to account for organ motion and deformation. We applied the 95% isodose cloud from the planning computed tomography scan to each CBCT scan and computed any CTV outside the 95% isodose cloud. The primary aim was to determine the proportion of CTVs that were encompassed within the 95% isodose volume. A 1-sample t test was used to test the hypothesis that the probability of complete coverage was different from 95%. We used mixed-effects logistic regression to assess effects of time and patient variability. Results: The 95% isodose line completely encompassed 92.3% of all CTVs (95% confidence interval, 88.3%-96.4%), not significantly different from the 95% probability anticipated a priori (P=.19). The overall proportion of missed CTVs was small: the grand mean of covered CTVs was 99.9%, and 95.2% of misses were located in the anterior body of the uterus. Time did not affect coverage probability (P=.71). Conclusions: With the clinical implementation of a previously proposed PTV definition strategy based on a shape model for intact cervical cancer, the probability of CTV coverage was high and the volume of CTV missed was low. This PTV expansion strategy is acceptable for clinical trials and practice; however, we recommend daily image guidance to avoid systematic large misses in select patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulated Online Adaptive Magnetic Resonance–Guided Stereotactic Body Radiation Therapy for the Treatment of Oligometastatic Disease of the Abdomen and Central Thorax: Characterization of Potential Advantages

Purpose: To characterize potential advantages of online-adaptive magnetic resonance (MR)-guided stereotactic body radiation therapy (SBRT) to treat oligometastatic disease of the non-liver abdomen and central thorax. Methods and Materials: Ten patients treated with RT for unresectable primary or oligometastatic disease of the non-liver abdomen (n=5) or central thorax (n=5) underwent imaging throughout treatment on a clinical MR image guided RT system. The SBRT plans were created on the basis of tumor/organ at risk (OAR) anatomy at initial computed tomography simulation (P{sub I}), and simulated adaptive plans were created on the basis of observed MR image set tumor/OAR “anatomy of the day” (P{sub A}). Each P{sub A} was planned under workflow constraints to simulate online-adaptive RT. Prescribed dose was 50 Gy/5 fractions, with goal coverage of 95% planning target volume (PTV) by 95% of the prescription, subject to hard OAR constraints. The P{sub I} was applied to each MR dataset and compared with P{sub A} to evaluate changes in dose delivered to tumor/OARs, with dose escalation when possible. Results: Hard OAR constraints were met for all P{sub Is} based on anatomy from initial computed tomography simulation, and all P{sub As} based on anatomy from each daily MR image set. Application of the P{sub I} to anatomy of the day caused OAR constraint violation in 19 of 30 cases. Adaptive planning increased PTV coverage in 21 of 30 cases, including 14 cases in which hard OAR constraints were violated by the nonadaptive plan. For 9 P{sub A} cases, decreased PTV coverage was required to meet hard OAR constraints that would have been violated in a nonadaptive setting. Conclusions: Online-adaptive MRI-guided SBRT may allow PTV dose escalation and/or simultaneous OAR sparing compared with nonadaptive SBRT. A prospective clinical trial is underway at our institution to evaluate clinical outcomes of this technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Joint Estimation of Cardiac Toxicity and Recurrence Risks After Comprehensive Nodal Photon Versus Proton Therapy for Breast Cancer

Purpose: The study aims to perform joint estimation of the risk of recurrence caused by inadequate radiation dose coverage of lymph node targets and the risk of cardiac toxicity caused by radiation exposure to the heart. Delivered photon plans are compared with realistic proton plans, thereby providing evidence-based estimates of the heterogeneity of treatment effects in consecutive cases for the 2 radiation treatment modalities. Methods and Materials: Forty-one patients referred for postlumpectomy comprehensive nodal photon irradiation for left-sided breast cancer were included. Comparative proton plans were optimized by a spot scanning technique with single-field optimization from 2 en face beams. Cardiotoxicity risk was estimated with the model of Darby et al, and risk of recurrence following a compromise of lymph node coverage was estimated by a linear dose-response model fitted to the recurrence data from the recently published EORTC (European Organisation for Research and Treatment of Cancer) 22922/10925 and NCIC-CTG (National Cancer Institute of Canada Clinical Trials Group) MA.20 randomized controlled trials. Results: Excess absolute risk of cardiac morbidity was small with photon therapy at an attained age of 80 years, with median values of 1.0% (range, 0.2%-2.9%) and 0.5% (range, 0.03%-1.0%) with and without cardiac risk factors, respectively, but even lower with proton therapy (0.13% [range, 0.02%-0.5%] and 0.06% [range, 0.004%-0.3%], respectively). The median estimated excess absolute risk of breast cancer recurrence after 10 years was 0.10% (range, 0.0%-0.9%) with photons and 0.02% (range, 0.0%-0.07%) with protons. The association between age of the patient and benefit from proton therapy was weak, almost non-existing (Spearman rank correlations of −0.15 and −0.30 with and without cardiac risk factors, respectively). Conclusions: Modern photon therapy yields limited risk of cardiac toxicity in most patients, but proton therapy can reduce the predicted risk of cardiac toxicity by up to 2.9% and the risk of breast cancer recurrence by 0.9% in individual patients. Predicted benefit correlates weakly with age. Combined assessment of the risk from cardiac exposure and inadequate target coverage is desirable for rational consideration of competing photon and proton therapy plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic and Magnetic Properties of Al Adsorption on α-Uranium(001) Surface: Ab Initio Calculations

First-principles calculations based on density functional theory with the generalized gradient approximation have been performed to study the aluminum (Al) adsorption on the (001) surface of α-uranium (α-U). The geometric, electronic and magnetic properties have been investigated at coverages of 0.25 and 0.5 monolayer. The results show that the quasi-trigonal sites are preferred at both coverages. The bonding of Al with U is found to be metallic, which mainly arises from the mixing of Al 3sp and U 5f states. A ferromagnetic phase is determined for the bare α-U(001) surface, while the adsorption of Al on the surface significantly perturbs the spin arrangement pattern and reduces the local magnetic moment, leading to a ferrimagnetic phase on the α-U(001) surface at the coverage of 0.5 monolayer. However, the Al overlayer is paramagnetic. Generally, the spin polarization has negligible effects on the geometric and electronic properties of Al atoms on the α-U(001) surface.

36 MATERIALS SCIENCE↗

Selectivity of Chemisorbed Oxygen in C–H Bond Activation and CO Oxidation and Kinetic Consequences for CH₄–O₂ Catalysis on Pt and Rh Clusters

Rate measurements, density functional theory (DFT) within the framework of transition state theory, and ensemble-averaging methods are used to probe oxygen selectivities, defined as the reaction probability ratios for O* reactions with CO and CH₄, during CH₄–O₂ catalysis on Pt and Rh clusters. CO₂ and H₂O are the predominant products, but small amounts of CO form as chemisorbed oxygen atoms (O*) are depleted from cluster surfaces. Oxygen selectivities, measured using ¹²CO–¹³CH₄–O₂ reactants, increase with O₂/ CO ratio and O* coverage and are much larger than unity at all conditions on Pt clusters. These results suggest that O* reacts much faster with CO than with CH₄, causing any CO that forms and desorbs from metal cluster surfaces to react along the reactor bed with other O* to produce CO₂ at any residence time required for detectable extents of CH₄ conversion. O* selectivities were also calculated by averaging DFTderived activation barriers for CO and CH₄ oxidation reactions over all distinct surface sites on cubo-octahedral Pt clusters (1.8 nm diameter, 201 Pt atoms) at low O* coverages, which are prevalent at low O₂ pressures during catalysis. CO oxidation involves non-activated molecular CO adsorption as the kinetically relevant step on exposed Pt atoms vicinal of chemisorbed O* atoms (on *–O* site pairs). CH₄ oxidation occurs via kinetically relevant C–H bond activation on *–* site pairs involving oxidative insertion of a Pt atom into one of the C–H bonds in CH₄, forming a three-centered HC₃–Pt–H transition state. C–H bond activation barriers reflect the strength of Pt–CH₃ and Pt–H interactions at the transition state, which correlates, in turn, with the Pt coordination and with CH₃ * binding energies. Ensemble-averaged O* selectivities increase linearly with O₂/CO ratios, which define the O* coverages, via a proportionality constant. The proportionality constant is given by the ratio of rate constants for O₂ dissociation and C–H bond activation elementary steps; the values for this constant are much larger than unity and are higher on larger Pt clusters (1.8–33 nm) at all temperatures (573–1273 K) relevant for CH₄–O₂ reactions. The barriers for the kinetically relevant C–H bond dissociation step increase, while those for CO oxidation remain unchanged as the Pt coordination number and cluster size increase, and lead, in turn, to higher O* selectivities on larger Pt clusters. Oxygen selectivities were much larger on Rh than Pt, because the limiting reactants for CO oxidation were completely consumed in ¹²CO–¹³CH₄–O₂ mixtures, consistent with lower CO/O₂ ratios measured by varying the residence time and O₂/CH₄ ratio independently in CH₄–O₂ reactions. These mechanistic assessments and theoretical treatments for O* selectivity provide rigorous evidence of low intrinsic limits of the maximum CO yields, thus confirming that direct catalytic partial oxidation of CH₄ to CO (and H₂) does not occur at the molecular scale on Pt and Rh clusters. CO (and H₂) are predominantly formed upon complete O₂ depletion from the sequential reforming steps.

Environmental Molecular Sciences Laboratory↗

Oxide-catalyzed self- and cross-condensation of cycloketones. Kinetically relevant steps that determine product distribution

Metal oxides with acid-base properties can be used to catalyze aldol condensation and potentially obtain valuable chemicals from biomass-derived oxygenates. Understanding the reaction mechanisms could enable the development of effective catalysts with controllable selectivity. In this work, we investigate the reaction parameters that affect the kinetics and product distribution of self- and cross-aldol condensation of cyclopentanone (CPO) and cyclohexanone (CHO) over CeO 2 and ZrO 2 catalysts by combining detailed analysis of experiments and DFT calculations. It is well-known that either the deprotonation of an α-C–H that generates an enolate or the C–C coupling that produces the dimers can be rate-limiting step. Indeed, the detailed kinetics analysis shows that the observed data can be fitted by unimolecular or bimolecular Langmuir-Hinshelwood models. Specifically, on the ZrO 2 catalyst, the unimolecular α-C–H activation is the rate limiting step for the CPO self-condensation, while the bimolecular C–C coupling limits the CHO self-condensation. By contrast, on CeO 2 , the bimolecular C–C coupling step seems to be rate-limiting for both CPO and CHO self-condensation reactions. The adsorption parameters derived from kinetics fitting indicate that when the two reactants are co-fed, the surface is preferentially covered by CHO. So, the condensation rate of [CPO]-activated products ([CPO]CPO + [CPO]CHO) decreases in the presence of CHO, due to the competitive adsorption. However, despite a higher surface coverage, CHO is not an effective electrophile because it imposes stronger steric constraints to the formation of the C–C bond than CPO. Therefore, for a given enolate, the product distribution shows that [CPO]CPO > [CPO]CHO and, similarly [CHO]CPO > [CHO]CHO. Likewise, the yields of [CPO]- and [CHO]-activated products in mixed CPO/CHO feeds are similar because the higher surface coverage and stability of the [CHO] enolate is counterbalanced by the inhibition of C–C coupling by steric constraints when CHO is involved. In summary, the overall rank of products observed experimentally can be explained in terms of a combination of the following effects: relative surface coverage of the reactants, steric constraints for the C–C coupling, stability of the enolate, and effectiveness of the electrophile to accept an electron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consequences of adsorbate-adsorbate interactions for apparent kinetics of surface catalytic reactions

Lateral adsorbate interactions at catalyst surfaces are known to influence adsorption energies and reaction rates. Lattice-based kinetic Monte Carlo (kMC) simulations are able to capture these influences, but such models are typically parameterized for a specific reaction network and catalyst surface. Here we report kMC simulations to probe the influence of lateral interactions on simulated rates, rate orders, apparent activation energies, and Sabatier plots. We construct a simple, two-step reaction network involving a single adsorbate and rate- limiting diatomic dissociation, employ a generic repulsive lateral interaction model consistent with known adsorbate-adsorbate interactions on metal surfaces, and a rate model consistent with known Brønsted-Evans-Polyani relationships for diatomic dissocations. Furthermore, we juxtapose reaction kinetics over a wide range of reaction conditions and catalyst binding energies, as a function of interaction strength. We find that at a given zero-coverage binding energy and external conditions, adsorbate coverage decreases monotonically with increasing interaction strength, but absolute rates can vary linearly or nonlinearly. Interactions flatten the Sabatier volcano and shift the maximum towards stronger binding. Influences on apparent rate orders and activation energies are modest and are sensitive to interaction-induced adsorbate ordering. Model predictions are sensitive to lattice size effects at high coverages. The results, modelled for a simple reaction system, highlight the generic consequences of lateral interactions and guidance for identifying their signatures in observed kinetics.

kinetic Monte Carlo↗

Neutron reflectivity study of substrate surface chemistry effects on supported phospholipid bilayer formation on (1120) sapphire.

Oxide-supported phospholipid bilayers (SPBs) used as biomimetric membranes are significant for a broad range of applications including improvement of biomedical devices and biosensors, and in understanding biomineralization processes and the possible role of mineral surfaces in the evolution of pre-biotic membranes. Continuous-coverage and/or stacjed SPBs retain properties (e.,g. fluidity) more similar to native biological membranes, which is desirable for most applications. Using neutron reflectivity, we examined face coverage and potential stacking of dipalmitoylphosphatidylcholine (DPPC) bilayers on the (1120) face of sapphire (a-Al2O3). Nearly full bilayers were formed at low to neutral pH, when the sapphire surface is positively charged, and at low ionic strength (l=15 mM NaCl). Coverage decreased at higher pH, close to the isoelectric point of sapphire, and also at high I>210mM, or with addition of 2mM Ca2+. The latter two effects are additive, suggesting that Ca2+ mitigates the effect of higher I. These trends agree with previous results for phospholipid adsorption on a-Al2O3 particles determined by adsorption isotherms and on single-crystal (1010) sapphire by atomic force microscopy, suggesting consistency of oxide surface chemistry-dependent effects across experimental techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Engineering surface segregation of perovskite oxide through wet exsolution for CO catalytic oxidation

Cation segregation occurring near the surface or interfaces of solid catalysts plays an important role in catalytic reactions. Unfortunately, the native surface of perovskite oxides is dominated by passivated A-site segregation, which severely hampers the catalytic activity and durability of the system. To address this issue, we present a wet exsolution method to reconstruct surface segregation in perovskite cobalt oxide. Here, under reduction etching treatment of glycol solution, inert surface Sr segregation was transformed into active Co 3 O 4 segregation. By varying the reaction time, we achieved differing coverage of the active Co 3 O 4 segregation on the La 0.5 Sr 0.5 CoO 3-δ (LSCO) perovskite oxide surface. This study reveals that CO oxidation activity exhibits a volcano-shaped dependence on the coverage of Co 3 O 4 segregation at the surface of a perovskite cobalt oxide. Furthermore, we find that a suitable coverage of Co 3 O 4 segregation can dramatically improve the catalytic activity of the perovskite catalyst by enhancing interface interactions. Co K-edge, Co L-edge, and O K-edge X-ray absorption spectra confirm that the synergistic effect optimizes the covalence of the metal-oxygen bond at the surface and interface. This work not only contributes to the design of perovskite-type catalysts, but also provides important insight into the relationship between surface segregation and catalytic activity.

36 MATERIALS SCIENCE↗

Effects of Intergranular Gas Bubbles on Thermal Conductivity

Model microstructures obtained from phase-field simulations are used to study the effective heat transfer across bicrys- tals with stationary grain boundary bubble populations. We find that the grain boundary coverage, irrespective of the intergranular bubble radii, is the most relevant parameter to the thermal resistance, which we use to derive effec- tive Kapitza resistances that are dependent on the grain boundary coverage and Kaptiza resistance of the intact grain boundary. We propose a model to predict thermal conductivity as a function of porosity, grain-size, Kaptiza resistance of the intact grain boundary, and grain boundary bubble coverage.

36 MATERIALS SCIENCE↗

Phase-field simulations of intergranular fission gas bubble behavior in U 3 Si 2 nuclear fuel

U 3 Si 2 is a potential accident-tolerant fuel that shows promise due to its high thermal conductivity and higher uranium density relative to UO 2 . However, its swelling and fission gas release behavior in light water reactor (LWR) conditions is relatively unknown. To provide mechanistic insight and determine parameters for engineering-scale fuel performance modeling of pellet-form U 3 Si 2 , phase-field simulations of the growth, interconnection, and venting of intergranular fission gas bubbles were performed. The fractional coverage of the grain boundary and the fraction of bubble area that is vented were calculated as a function of time. From the simulation data, the fractional grain boundary coverage at saturation, an important parameter needed in engineering-scale modeling of swelling and fission gas release, was determined. Multiple simulations were run to determine the uncertainty in the calculated value. Finally, the effect of model assumptions and input parameters that are not well known was evaluated. Simulation results are compared to related theoretical and computational work. Based on the simulation results, a value of 0.60 for the fractional grain boundary coverage at saturation is recommended for U 3 Si 2 fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ag adsorption on Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces: First-principles investigations

First-principles calculations are performed to study the adsorption of Ag at Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces as a function of Ag coverage. Our results reveal that Ag adsorption at Cd-terminated (0 0 0 1) has a large binging energy than at S-terminated (0 0 0 1-bar) surface. For Ag adsorption at Cd-terminated (0 0 0 1) surface, T4 structure is more favorable and the Ag-Cd bond posses an ionic-like character. While for Ag adsorption at S-terminated (0 0 0 1-bar) surface, the H3 structure is most stable and the bonding between Ag-S is covalent. It is found that the magnitude and the sign of surface dipole moment are partly determined by the difference between the electronegativities of Ag and the host atom bonding with Ag. The adsorption energy changes as a function of Ag coverage. In addition, related properties of Ag cluster adsorption at Cd-terminated (0 0 0 1) surface are also discussed. -- Graphical abstract: We studied the adsorption of Ag at Cd-terminated CdS (0 0 0 1) and S-terminated CdS (0 0 0 1-bar) surfaces as a function of Ag coverage by means of the first-principles calculations. In addition, related properties of Ag cluster adsorption at Cd-terminated (0 0 0 1) surface are also discussed. Our ab initio calculations are useful complement to the intense experimental studies for Ag-CdS interface. Display Omitted Research highlights: {yields} Ag adsorption effects on electronic structure and associated physics properties of CdS is systemically studied. {yields} The surface dipole moment is partly determined by the difference between the electronegativities of silver and the host atom bonding with silver. {yields} The characteristic of Ag cluster (Ag{sub 2}, Ag{sub 4}, and Ag{sub 7}) adsorption on the CdS (0 0 0 1) surface is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Split-Volume Treatment Planning of Multiple Consecutive Vertebral Body Metastases for Cyberknife Image-Guided Robotic Radiosurgery

Cyberknife treatment planning of multiple consecutive vertebral body metastases is challenging due to large target volumes adjacent to critical normal tissues. A split-volume treatment planning technique was developed to improve the treatment plan quality of such lesions. Treatment plans were generated for 1 to 5 consecutive thoracic vertebral bodies (CVBM) prescribing a total dose of 24 Gy in 3 fractions. The planning target volume (PTV) consisted of the entire vertebral body(ies). Treatment plans were generated considering both the de novo clinical scenario (no prior radiation), imposing a dose limit of 8 Gy to 1 cc of spinal cord, and the retreatment scenario (prior radiation) with a dose limit of 3 Gy to 1 cc of spinal cord. The split-volume planning technique was compared with the standard full-volume technique only for targets ranging from 2 to 5 CVBM in length. The primary endpoint was to obtain best PTV coverage by the 24 Gy prescription isodose line. A total of 18 treatment plans were generated (10 standard and 8 split-volume). PTV coverage by the 24-Gy isodose line worsened consistently as the number of CVBM increased for both the de novo and retreatment scenario. Split-volume planning was achieved by introducing a 0.5-cm gap, splitting the standard full-volume PTV into 2 equal length PTVs. In every case, split-volume planning resulted in improved PTV coverage by the 24-Gy isodose line ranging from 4% to 12% for the de novo scenario and, 8% to 17% for the retreatment scenario. We did not observe a significant trend for increased monitor units required, or higher doses to spinal cord or esophagus, with split-volume planning. Split-volume treatment planning significantly improves Cyberknife treatment plan quality for CVBM, as compared to the standard technique. This technique may be of particular importance in clinical situations where stringent spinal cord dose limits are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical and Dosimetric Considerations in Multi-Isocenter Intensity Modulated Radiotherapy for Nasopharyngeal carcinoma with Small Multileaf Collimator

Multileaf collimator (MLC)-assisted intensity modulated radiotherapy (IMRT) has greatly improved the target coverage and avoidance of organs at risk (OAR) for the treatment of nasopharyngeal carcinoma; however, its implementation is also constrained by the features of the MLC. Nasopharyngeal carcinoma tends to have a large gross target volume (GTV) and clinical target volume (CTV) due to its biological characteristics. More than one isocenter may be needed when small MLCs (i.e., BrainLAB M3, whose largest field is 10 x 10 cm{sup 2}) are used to treat the nasopharyngeal carcinoma. The BrainLAB IMRT system was used to evaluate the effectiveness of a multi-isocenter IMRT plan for treating nasopharyngeal cancers. Dose coverage of GTVs and CTVs were compared among IMRT plans with 1, 2 and 3 isocenters, as were dose objectives for OARs including brainstem, cord, and parotids. The dosimetric variation and the delivery time were also measured with a phantom. IMRT plans with more than 1 isocenter achieved a better dose coverage, homogeneity, and conformity on GTVs and CTVs; however, with risk of higher doses given to OARs. In most cases, one can generate satisfactory IMRT plans using the 2-isocenter IMRT planning strategy. Two-isocenter planning strategy may be a suitable compromise when more isocenters are needed.

61 RADIATION PROTECTION AND DOSIMETRY↗