Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

X-ray streak camera cathode development and timing accuracy of the 4{omega} ultraviolet fiducial system at the National Ignition Facility

The convergent ablator experiments at the National Ignition Facility (NIF) are designed to measure the peak velocity and remaining ablator mass of an indirectly driven imploding capsule. Such a measurement can be performed using an x-ray source to backlight the capsule and an x-ray streak camera to record the capsule as it implodes. The ultimate goal of this experiment is to achieve an accuracy of 2% in the velocity measurement, which translates to a {+-}2 ps temporal accuracy over any 300 ps interval for the streak camera. In order to achieve this, a 4{omega} (263 nm) temporal fiducial system has been implemented for the x-ray streak camera at NIF. Aluminum, titanium, gold, and silver photocathode materials have been tested. Aluminum showed the highest relative quantum efficiency, with five times more peak signal counts per fiducial pulse when compared to Gold. The fiducial pulse data were analyzed to determine the centroiding statistical accuracy for incident laser pulse energies of 1 and 10 nJ, showing an accuracy of {+-}1.6 ps and {+-}0.7 ps, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE FRACTAL DENSITY STRUCTURE IN SUPERSONIC ISOTHERMAL TURBULENCE: SOLENOIDAL VERSUS COMPRESSIVE ENERGY INJECTION

In a systematic study, we compare the density statistics in high-resolution numerical experiments of supersonic isothermal turbulence, driven by the usually adopted solenoidal (divergence-free) forcing and by compressive (curl-free) forcing. We find that for the same rms Mach number, compressive forcing produces much stronger density enhancements and larger voids compared to solenoidal forcing. Consequently, the Fourier spectra of density fluctuations are significantly steeper. This result is confirmed using the {delta}-variance analysis, which yields power-law exponents {beta} {approx} 3.4 for compressive forcing and {beta} {approx} 2.8 for solenoidal forcing. We obtain fractal dimension estimates from the density spectra and {delta}-variance scaling, and by using the box counting, mass size, and perimeter area methods applied to the volumetric data, projections, and slices of our turbulent density fields. Our results suggest that compressive forcing yields fractal dimensions significantly smaller compared to solenoidal forcing. However, the actual values depend sensitively on the adopted method, with the most reliable estimates based on the {delta}-variance, or equivalently, on Fourier spectra. Using these methods, we obtain D {approx} 2.3 for compressive and D {approx} 2.6 for solenoidal forcing, which is within the range of fractal dimension estimates inferred from observations (D {approx} 2.0-2.7). The velocity dispersion to size relations for both solenoidal and compressive forcings obtained from velocity spectra follow a power law with exponents in the range 0.4-0.5, in good agreement with previous studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suzaku X-ray observations of the Fermi Bubbles: Northernmost cap and southeast claw discovered with maxi-SSC

We report on Suzaku observations of large-scale X-ray structures possibly related to the Fermi Bubbles obtained in 2013 with a total duration of ≃80 ks. The observed regions were (1) the northern cap (N-cap; l ∼ 0°, 45°<b< 55°) seen in the mid-band (1.7–4.0 keV) map recently provided by Monitor of All-sky X-ray Image Solid-state Slit Camera (MAXI-SSC) and (2) the southeast claw (SE-claw; l ∼ 10°, −20{sup ∘}<b<−10{sup ∘}) seen in the ROSAT all-sky map and MAXI-SSC low-band (0.7–1.7 keV) map. In each region, we detected diffuse X-ray emission, which is represented by a three-component plasma model consisting of an unabsorbed thermal component (kT ≃ 0.1 keV) from the Local Hot Bubble, absorbed kT = 0.30 ± 0.05 keV emission representing the Galactic halo (GH), and a power-law component due to the isotropic cosmic X-ray background radiation. The emission measure of the GH component in the SE-claw shows an excess by a factor of ≃2.5 over the surrounding emission at 2° away. We also found a broad excess in the 1.7–4.0 keV count rates across the N-cap after compiling other archival data from Suzaku and Swift. The spectral stacking analysis of the N-cap data indicates the presence of another thermal component with kT = 0.70{sub −0.11}{sup +0.22}keV. The temperature kT ≃ 0.3 keV of the GH is higher than the ubiquitous value of kT ≃ 0.2 keV near the Fermi bubbles, and can be even higher (∼0.7 keV). We discuss our findings in the context of the bubble–halo interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

Including massive neutrinos in thermal Sunyaev Zeldovich power spectrum and cluster counts analyses

We consistently include the effect of massive neutrinos in the thermal Sunyaev Zeldovich (SZ) power spectrum and cluster counts analyses, highlighting subtle dependencies on the total neutrino mass and data combination. In particular, we find that using the transfer functions for cold dark matter (CDM) + baryons in the computation of the halo mass function, instead of the transfer functions including neutrino perturbations, as prescribed in recent work, yields an ≈0.25 percent downward shift of the σ 8 constraint from tSZ power spectrum data, with a fiducial neutrino mass Σm ν = 0.06 eV. In ΛCDM, with an X-ray mass bias corresponding to the expected hydrostatic mass bias, i.e. (1 - b) ≃ 0.8, our constraints from Planck SZ data are consistent with the latest results from SPT, DES-Y1, and KiDS+VIKING-450. In νΛCDM, our joint analyses of Planck SZ with Planck 2015 primary CMB yield a small improvement on the total neutrino mass bound compared to the Planck 2015 primary CMB constraint, as well as (1 - b) = 0.64 ± 0.04 (68 percent CL). For forecasts, we find that competitive neutrino mass measurements using cosmic variance limited SZ power spectrum require masking the heaviest clusters and probing the small-scale SZ power spectrum up to ℓ max ≈ 10 4 . Although this is challenging, we find that SZ power spectrum can realistically be used to tightly constrain intracluster medium properties: we forecast a 2 percent determination of the X-ray mass bias by combining CMB-S4 and our mock SZ power spectrum with ℓ max = 10 3 .

Astronomy & Astrophysics↗

A Compact, Flexible, High Channel Count DAQ Built From Off-the-Shelf Components

Medium to large channel count detectors are usually faced with a few unattractive options for data acquisition (DAQ). Small to medium sized TPC experiments, for example, can be too small to justify the high expense and long development time of application specific integrated circuit (ASIC) development. In some cases an experiment can piggy-back on a larger experiment and the associated ASIC development, but this puts the time line of development out of the hands of the smaller experiment. Another option is to run perhaps thousands of cables to rack mounted equipment, which is clearly undesirable. The development of commercial high-speed high-density FPGAs and ADCs combined with the small discrete components and robotic assembly open a new option that scales to tens of thousands of channels and is only slightly larger than ASICs using off-the-shelf components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of aldo‐keto reductase 1 C 3 ( AKR 1 C 3)‐mediated prostaglandin D 2 ( PGD 2) metabolism in keloids

Abstract Keloids are progressively expanding scars, mostly prevalent in individuals of African descent. Previous data identified increased mast cell number and activation state in keloids suggesting a role in disease progression. The major eicosanoid secreted by mast cells is prostaglandin D2 ( PGD 2), a relatively unstable pro‐inflammatory mediator which can be spontaneously converted to 15‐deoxy‐(Delta12,14)‐prostaglandin J2(15d‐PGJ2) or enzymatically metabolized to 9α,11β‐ PGF 2 by aldo‐keto reductase 1C3 ( AKR 1C3). In this work, we investigated the possible role of PGD 2 and its metabolites in keloids using CRL 1762 keloid fibroblasts ( KF ) and immunohistochemical staining. Our data suggested approximately 3‐fold increase of tryptase‐positive mast cell count in keloids compared with normal skin. Furthermore, AKR 1C3 was overexpressed in the fibrotic area of keloids while relatively weak staining detected in normal skin. Metabolism of PGD 2 to 9 α ,11 β ‐ PGF 2 by both, KF and normal fibroblasts, was dependent on AKR 1C3 as this reaction was attenuated in the presence of the AKR 1C3 inhibitor, 2′‐hydroxyflavanone, or in cells with decreased AKR 1C3 expression. 15d‐ PGJ 2, but not the other tested PG s, inhibited KF proliferation, attenuated KF ‐mediated collagen gel contraction and increased caspase‐3 activation. In addition, treatment with 15d‐ PGJ 2 activated P38‐ MAPK , induced reactive oxygen species and upregulated superoxide dismutase‐1 ( SOD ‐1). Finally, inhibition of P38‐ MAPK further augmented 15d‐ PGJ 2‐induced caspase‐3 cleavage and attenuated its effect on SOD ‐1 transcription. This work suggests that localized dual inhibition of AKR 1C3 and P38‐ MAPK may inhibit keloid progression. Inhibiting AKR 1C3 activity may generate oxidative environment due to redirection of PGD 2 metabolism towards 15d‐ PGJ 2 while inhibition of P38‐ MAPK will sensitize keloid cells to ROS ‐induced apoptosis.

Mantel, Alon↗

High-Sensitivity Fast Neutron Detector KNK-2-8M

The design of the fast neutron detector KNK-2-8M is outlined. The results of he detector study in the pulse counting mode with pulses from {sup 238}U nuclei fission in the radiator of the neutron-sensitive section and in the current mode with separation of functional section currents are presented. The possibilities of determination of the effective number of {sup 238}U nuclei in the radiator of the neutron-sensitive section are considered. The diagnostic capabilities of the detector in the counting mode are demonstrated, as exemplified by the analysis of reference data on characteristics of neutron fields in the BR-1 reactor hall. The diagnostic capabilities of the detector in the current mode are demonstrated, as exemplified by the results of measurements of {sup 238}U fission intensity in the power startup of the BR-K1 reactor in the fission pulse generation mode with delayed neutrons and the detector placed in the reactor cavity in conditions of large-scale variation of the reactor radiation fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incoherent range-based holography of far-distant objects using LIDAR

Los Alamos National Laboratory has developed an incoherent, long-range, sub-centimeter resolution (LIDAR) with which we achieve centimeter-scale reflection holography at extremely long ranges. The system consists of a pulsed laser and photon-counting receiver. This combination yields round-trip time of flight data to illuminate parts of the object of interest. The aggregation of these data for many LIDAR pulses yields a plot with a range on the X axis and reflectance on the Y axis, which we refer to as a range profile. Observing that the range profile is a projection of the reflection map of the object onto the view vector, we collect profiles from a variety of viewing angles and invert these data to form an image. We adapt imaging algorithms from the field of computer aided tomography to suit our application and present results from imaging demonstrations at a 10 km range.

Hoffmann, Mitchell P. (ORCID:0000000170551324)↗

Fission-product decay studies with the FRIB Decay Station

The Facility for Rare Isotopes Beams (FRIB) will be the flagship facility in low-energy nuclear physics when it comes online in 2022. This U.S. Department of Energy Office of Science user facility will open up a multitude of new opportunities to study exotic nuclei and will lead to new discoveries in nuclear structure, nuclear astrophysics, fundamental symmetries, and isotopes of importance to nuclear applications. The b-decay properties of neutron-rich isotopes will be measured with the FRIB Decay Station, a sophisticated state-of-the-art modular multi-detector system envisioned to perform b, g, n, and charged-particle spectroscopy. In this feasibility study, we use nuclear decay data collected with the FRIB Decay Station precursor, the Beta-Counting Station, currently used at Michigan State University with a radioactive beam produced at the National Superconducting Cyclotron Laboratory to identify the FRIB Decay Station capabilities for future measurements of neutron-rich exotic nuclei at FRIB to help provide a path forward for future measurements of interest to the lab’s mission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Prospect of Chemically Transferable Coarse-Grained Electronic Models for Soft Materials

Electronic coarse-graining (ECG) methods predict quantum-mechanical electronic properties directly from coarse-grained (CG) molecular configurations, enabling electronic predictions at mesoscale length scales. Here, we present a diagnostic assessment of the feasibility of chemically transferable ECG models across a broad polymer-relevant chemical space using all-atom, united-atom, and Martini-scale representations. While high-resolution ECG models achieve near-quantitative accuracy, we show that chemically transferable ECG at the Martini resolution fails because the CG force field does not sample the same configurational distribution of local molecular structure as that underlying the DFT-parameterized ECG model. We demonstrate that our proposed Element-Count-Label (ECL) representation, which augments Martini beads with explicit stoichiometric data, significantly improves chemical generalization across diverse polymer chemistries. However, we find that even with improved chemical resolution, the model cannot recover electronic property distributions that are absent from the configurational space sampled by the CG force field. These results demonstrate that chemically transferable ECG requires future Martini-like force fields to explicitly preserve quantum chemistry–compatible local molecular structure in addition to thermodynamic and structural fidelity.

Kidder, Katherine M [Department of Chemistry; Univ↗

The Spitzer-IRAC/MIPS Extragalactic survey (SIMES) IN the south ecliptic pole field

We present the Spitzer-IRAC/MIPS Extragalactic survey (SIMES) in the South Ecliptic Pole field. The large area covered (7.7 deg{sup 2}), together with one of the lowest Galactic cirrus emissions in the entire sky and a very extensive coverage by Spitzer, Herschel, Akari, and GALEX, make the SIMES field ideal for extragalactic studies. The elongated geometry of the SIMES area (≈4:1), allowing for significant cosmic variance reduction, further improves the quality of statistical studies in this field. Here we present the reduction and photometric measurements of the Spitzer/IRAC data. The survey reaches depths of 1.93 and 1.75 μJy (1σ) at 3.6 and 4.5 μm, respectively. We discuss the multiwavelength IRAC-based catalog, completed with optical, mid-, and far-IR observations. We detect 341,000 sources with F{sub 3.6μm}⩾3σ. Of these, 10% have an associated 24 μm counterpart, while 2.7% have an associated SPIRE source. We release the catalog through the NASA/IPAC Infrared Science Archive. Two scientific applications of these IRAC data are presented in this paper. First, we compute integral number counts at 3.6 μm. Second, we use the [3.6]–[4.5] color index to identify galaxy clusters at z > 1.3. We select 27 clusters in the full area, a result consistent with previous studies at similar depth.

79 ASTRONOMY AND ASTROPHYSICS↗

Counter tube window and X-ray fluorescence analyzer study

A study was performed to determine the best design tube window and X-ray fluorescence analyzer for quantitative analysis of Venusian dust and condensates. The principal objective of the project was to develop the best counter tube window geometry for the sensing element of the instrument. This included formulation of a mathematical model of the window and optimization of its parameters. The proposed detector and instrument has several important features. The instrument will perform a near real-time analysis of dust in the Venusian atmosphere, and is capable of measuring dust layers less than 1 micron thick. In addition, wide dynamic measurement range will be provided to compensate for extreme variations in count rates. An integral pulse-height analyzer and memory accumulate data and read out spectra for detail computer analysis on the ground.

Hertel, R.↗

The effects of space flight on polymorphonuclear leukocyte response experiment MA-032

In a series of studies performed at intervals from 30 day before flight to 30 days after recovery, blood samples were obtained from the three astronauts of the Apollo Soyuz Test Project and from eight control subjects. To determine the effects of space flight on polymorphonuclear leukocytes, tests were performed on blood samples obtained as quickly as possible after splashdown and on the day following recovery. The astronauts' inhalation of propellant gases and the inception of corticosteroid therapy 1 day after recovery provided an additional opportunity to investigate the possible effects of these factors on leukocyte function. Data were obtained during each time period on the total leukocyte count, differential count, leukocyte adhesion, leukocyte migration and chemotaxis, phagocytosis, and histochemical staining for leukocyte acid and alkaline phosphatase. These observations present a variety of in vitro correlates to white blood cell function within the body. Taken together, they serve as a reasonable approximation of the effects of space flight on leukocyte function.

Martin, R. R.↗

Spatial distribution of Compton-produced X-ray flux from rich and regular clusters of galaxies

The spatial distribution of radio and X-ray fluxes from rich and regular clusters of galaxies is discussed. A diffusion model is investigated in which high-energy electrons are ejected from a point source at the center of the cluster. While diffusing out, the electrons lose energy by Compton scattering with the universal blackbody photons, thus producing the X-ray emission. Traversing intracluster magnetic fields, the electrons emit synchrotron radio emission. For the Coma cluster of galaxies good agreement is found between the observed and predicted X-ray counting-rate distribution for the Compton model. From the observed radio data a value of about 3 by 10 to the -8th power gauss is deduced for the average magnetic-field strength in the central region of Coma.

Rephaeli, Y.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗