Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Building America Case Study: Multifamily Central Heat Pump Water Heaters, Davis, California

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16-month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

30 DIRECT ENERGY CONVERSION↗

Achievements of the DOT-NASA Joint Program on Remote Sensing and Spatial Information Technologies: Application to Multimodal Transportation

This report presents three-year accomplishments from the national program on Commercial Remote Sensing and Geospatial Technology (CRSGT) application to transportation, administered by the U.S. Department of Transportation (U.S. DOT) in collaboration with the National Aeronautics and Space Administration (NASA). The joint program was authorized under Section 5113 of the Transportation Equity Act for the 21st Century (TEA-21). This is the first national program of its type focusing on transportation applications of emerging commercial remote sensing technologies. U.S. DOT's Research and Special Programs Administration manages the program in coordination with NASA's Earth Science Enterprise's application programs. The program focuses on applications of CRSGT products and systems for providing smarter and more efficient transportation operations and services. The program is performed in partnership with four major National Consortia for Remote Sensing in Transportation (NCRST). Each consortium focuses on research and development of products in one of the four priority areas for transportation application, and includes technical application and demonstration projects carried out in partnership with industries and service providers in their respective areas. The report identifies products and accomplishments from each of the four consortia in meeting the goal of providing smarter and more efficient transportation services. The products and results emerging from the program are being implemented in transportation operations and services through state and local agencies. The Environmental Assessment and Application Consortium (NCRST-E) provides leadership for developing and deploying cost effective environmental and transportation planning services, and integrates CRSGT advances for achieving smarter and cost effective corridor planning. The Infrastructure Management Consortium (NCRST-I) provides leadership in technologies that achieve smarter and cheaper ways of managing transportation infrastructure assets, operation, and inspection, and integrates CRSGT advances for achieving infrastructure security. The Traffic Flow Consortium (NCRST-F) provides leadership to develop new tools for regional traffic flow management including heavy vehicles and intermodal flow of freight, and integrates CRSGT advances for complementing and extending the reach of ITS user services. The Safety, Hazards and Disasters (NCRST-H) provides leadership for deploying remote sensing technology to locate transportation hazards and improve disaster recovery, and integrates CRSGT advances for application to protect transportation systems from terrorism. The DOT-NASA team is proud to present this report of accomplishments on products and results emerging from the joint program for application to transportation practice.

Source record↗

CFD Study of Full-Scale Aerobic Bioreactors: Evaluation of Dynamic O2 Distribution, Gas-Liquid Mass Transfer and Reaction

If advanced biofuels are to measurably displace fossil fuels in the near term, they will have to operate at levels of scale, efficiency, and margin unprecedented in the current biotech industry. For aerobically-grown products in particular, scale-up is complex and the practical size, cost, and operability of extremely large reactors is not well understood. Put simply, the problem of how to attain fuel-class production scales comes down to cost-effective delivery of oxygen at high mass transfer rates and low capital and operating costs. To that end, very large reactor vessels (>500 m3) are proposed in order to achieve favorable economies of scale. Additionally, techno-economic evaluation indicates that bubble-column reactors are more cost-effective than stirred-tank reactors in many low-viscosity cultures. In order to advance the design of extremely large aerobic bioreactors, we have performed computational fluid dynamics (CFD) simulations of bubble-column reactors. A multiphase Euler-Euler model is used to explicitly account for the spatial distribution of air (i.e., gas bubbles) in the reactor. Expanding on the existing bioreactor CFD literature (typically focused on the hydrodynamics of bubbly flows), our simulations include interphase mass transfer of oxygen and a simple phenomenological reaction representing the uptake and consumption of dissolved oxygen by submerged cells. The simulations reproduce the expected flow profiles, with net upward flow in the center of column and downward flow near the wall. At high simulated oxygen uptake rates (OUR), oxygen-depleted regions can be observed in the reactor. By increasing the gas flow to enhance mixing and eliminate depleted areas, a maximum oxygen transfer (OTR) rate is obtained as a function of superficial velocity. These insights regarding minimum superficial velocity and maximum reactor size are incorporated into NREL's larger techno-economic models to supplement standard reactor design equations.

09 BIOMASS FUELS↗

Beyond Widgets -- Systems Incentive Programs for Utilities

Utility incentive programs remain one of the most significant means of deploying commercialized, but underutilized building technologies to scale. However, these programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – baseline energy use must be defined and measured; the metrics for energy and performance must be defined and tested against; in addition, system savings must be validated under well understood conditions. This paper presents a sample of findings of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with Xcel Energy (CO, MN), ComEd, and a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)). Furthermore, these program packages consist of system specifications, system performance, M&V protocols, streamlined assessment methods, market assessment and implementation guidance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beyond Widgets: Validated Systems Energy Savings and Utility Custom Incentive Program Systems Trends

Energy efficiency upgrades to buildings to date through avenues such as utility incentive programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Integrated building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings (Regnier et al. 2017) that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – energy savings assessments are inherently more complex and are not easily suited to the deemed measure model, and implementation of systems can be more disruptive. This paper presents the outcomes of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with ComEd, a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)), and Xcel Energy (CO, MN). Previous work described the potential for energy savings of these systems at the individual and market level, early test findings for the task-ambient lighting system, and described the work products to develop utility incentive programs (Regnier et al. 2016). This paper presents validated end use energy savings of all three systems showing energy savings of ~20% for automated shading combined with daylight dimming (does not include light fixture retrofit savings); 30-46% for task-ambient lighting systems combined with plug load occupancy controls, depending on technology package and office building size (no daylight dimming impacts); and ~94% in the south-façade daylit zone for workstation specific lighting systems with daylight dimming (including lighting retrofit and task tuning). Using a U.S. Department of Energy (DOE) reference building model (DOE 2018), this translates to whole building savings of 2-5% (large-medium commercial), 12-23% (large-small commercial), and 13-15% (medium-large commercial) for these systems respectively. Early findings from the utilities in deploying these systems through their incentive programs indicate that deployment methods such as direct install programs might be best suited for these integrated systems. Further, early findings from a scoping study across custom utility programs and federal retrofit programs indicate that component level retrofits are still prevalent even in these programs, pointing towards an opportunity for deeper energy savings deployment. High performance retrofit case studies demonstrate that deeper energy savings is possible through integrated approaches. Market stakeholder interviews indicate however that there is generally a low level of awareness of the potential for energy savings of these three integrated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air pollution control strategies directly limiting national health damages in the US

Exposure to fine particulate matter (PM 2.5 ) from fuel combustion significantly contributes to global and US mortality. Traditional air pollution control strategies typically focus on emission reductions for specific air pollutants or sectors to maintain air pollutant concentrations within acceptable levels. Here we directly set national PM 2.5 mortality cost reduction targets within a global human-earth system model with US state-level energy systems, identifying endogenously the control actions, sectors, and locations that most cost-effectively reduce PM 2.5 mortality. Our results show that substantial health benefits can be cost-effectively achieved by using electricity to replace sources with high primary PM 2.5 emission intensities, including industrial coal, building biomass, and industrial liquids. Increasing the stringency of PM 2.5 reduction targets expedites the phaseout of high emission intensity sources, leading to larger declines in major air pollutant emissions, but very limited co-benefits in reducing CO 2 emissions. Control strategies achieve the greatest mortality cost reductions in the East North Central and Middle Atlantic states.

54 ENVIRONMENTAL SCIENCES↗

Development of a Technical, Economic, and Risk Assessment Tool for the Evaluation of Work Reduction Opportunities

Efficient and cost-effective operation of a nuclear power plant (NPP) is essential to ensuring long-term economical and safe operation. Multiple cost saving opportunities exist, referred to here as work reduction opportunities (WRO). These WROs reduce plant operating costs by employing various cost-effective strategies (e.g., implementation of modern technologies). Identifying and objectively screening WROs is an essential task to help reduce overall costs. However, there is no comprehensive framework for assessing WROs in the nuclear industry and evaluating their impact on plant operations. This report presents a novel framework for systematically evaluating WROs from a technical, economic, and risk perspective. As NPPs continue to add new technology and implement modernization strategies into their current processes, potential WROs are commonly identified. Although most WROs have the potential to reduce costs, not all opportunities will result in significant cost savings due to unforeseen risks, large implementation costs, or benefits that fall short of expectations. Examples of this can be the result of a technology that is not fully developed, uncertainty in the amount of cost reduction, or difficulties introducing a new process into an organization. These uncertainties can manifest several ways and can result in a WRO with limited cost savings or even a loss of investment. The framework developed emphasizes the importance of effectively screening the WROs from a holistic perspective to objectively identify inefficiencies and ensure a positive impact to the organization. This report presents the Technical, Economic, and Risk Assessment (TERA) as a key methodology for the screening and evaluation of potential WROs. The TERA framework begins with a screening phase where the process is examined through a hybrid combination of Lean Six Sigma and Integrated Operations for Nuclear (ION) guiding principles. This framework examines the current processes using the Lean Six Sigma SIPOC (Suppliers, Inputs, Process, Outputs, Consumers) methodology but retains the ION key elements of People, Technology, Process, and Governance as important factors to the nuclear decision-making process. By combining the principles of Lean Six Sigma and ION, the developed screening process is specific to the nuclear industry in that it systematically evaluates WROs in order to implement new technology that is comprehensively evaluated. The TERA begins by mapping current processes as they relate to WROs and examining the inefficiencies. Furthermore, the created process map can be used to identify and evaluate potential solutions. Using key performance indicators (KPIs), the TERA evaluates each area—technology, economics, and risk—for uncertainties and to perform cost-benefit analysis. The results of the TERA are important KPIs that allow for an evaluation of different processes and technology implementations. This assessment enables decision-makers to compare various WROs based on metrics and then make informed decisions for which opportunity to implement first. This research includes not only the creation of the TERA framework, but also the evaluation of its performance. A case study for screening potential WROs at Southern Nuclear Company is presented that utilizes the TERA methodology. Through the use of TERA, various WROs were screened, and the solutions evaluated for cost-benefit expectations. The report concludes by summarizing the overall effort and implications for utility modernization. The performance of the screening and TERA are discussed as well as the impact on the nuclear industry. The TERA process enables utilities to evaluate and inform investment decisions for WROs and mitigate any potential risks. Through this research, we provide utilities with a valuable framework to optimize operations, reduce costs, and drive continuous process improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Feasibility of Economic Analysis of Radiation Therapy Oncology Group (RTOG) 91-11 Using Medicare Data

Purpose: The specific aim of this analysis was to evaluate the feasibility of performing a cost-effectiveness analysis using Medicare data from patients treated on a randomized Phase III clinical trial. Methods and Materials: Cost data included Medicare Part A and Part B costs from all providers-inpatient, outpatient, skilled nursing facility, home health, hospice, and physicians-and were obtained from the Centers for Medicare and Medicaid Services for patients eligible for Medicare, treated on Radiation Therapy Oncology Group (RTOG) 9111 between 1992 and 1996. The 47-month expected discounted (annual discount rate of 3%) cost for each arm of the trial was calculated in 1996 dollars, with Kaplan-Meier sampling average estimates of survival probabilities for each month and mean monthly costs. Overall and disease-free survival was also discounted 3%/year. The analysis was performed from a payer's perspective. Incremental cost-effectiveness ratios were calculated comparing the chemotherapy arms to the radiation alone arm. Results: Of the 547 patients entered, Medicare cost data and clinical outcomes were available for 66 patients. Reasons for exclusion included no RTOG follow-up, Medicare HMO enrollment, no Medicare claims since trial entry, and trial entry after 1996. Differences existed between groups in tumor characteristics, toxicity, and survival, all which could affect resource utilization. Conclusions: Although we were able to test the methodology of economic analysis alongside a clinical trial using Medicare data, the results may be difficult to translate to the entire trial population because of non-random missing data. Methods to improve Medicare data capture and matching to clinical trial samples are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DOE Commercial Building Energy Asset Rating: Market Research and Program Direction

This paper presents the development of a voluntary energy asset rating system, to evaluate the physical characteristics and as-built energy efficiency of new and existing commercial buildings. The energy asset rating system is intended to enable commercial building stakeholders to directly compare expected as-built energy performance among similar buildings and to analyze the potential for capital improvements to increase energy efficiency cost-effectively. Market research has been performed to understand the market demand and how to communicate energy and cost savings to owners, investors, financiers, and others to overcome market barriers and motivate capital investment in building energy efficiency. The paper discusses the findings of the market research. Building owners are concerned about redundancy, conflicting requirements, and cost. They also pointed out a data gap and desire a rating program that identifies improvement opportunities. A meaningful linkage between the energy asset rating and other rating systems is essential. Based on the findings, criteria for a successful energy asset rating program have been developed to direct the program design, including validity of ratings, actionable, cost effective recommendations, effective quality control, integration with other rating systems, and necessary training and education. In addition to the rating system, an asset rating tool is being developed to reduce cost and increase standardization, allowing for consistent and reliable comparisons among and between buildings. The asset rating tool is the first step in the process by which owners can enter information about their building structure and receive information on the building’s modeled performance and recommended efficiency measures.

commercial building, energy asset rating, market r↗

The hydrogen economy can reduce costs of climate change mitigation by up to 22%

In response to the urgent need to mitigate climate change via net-zero targets, many nations are renewing their interest in clean hydrogen as a net-zero energy carrier. Although clean hydrogen can be directly used in various sectors for deep decarbonization, the relatively low energy density and high production costs have raised doubts as to whether clean hydrogen development is worthwhile. Here, we improve on the GCAM model by including a more comprehensive and detailed representation of clean hydrogen production, distribution, and demand in all sectors of the global economy and simulate 25 scenarios to explore the cost-effectiveness of integrating clean hydrogen into the global energy system. We show that, due to costly technical obstacles, clean hydrogen can only provide 3%–9% of the 2050 global final energy use. Nevertheless, clean hydrogen deployment can reduce overall energy decarbonization costs by 15%–22%, mainly via powering “hard-to-electrify” sectors that would otherwise face high decarbonization expenditures. Our work provides practical references for cost-effective clean hydrogen planning.

08 HYDROGEN↗

National Energy Efficiency Evaluation, Measurement and Verification (EM&V) Standard: Scoping Study of Issues and Implementation Requirements

This report is a scoping study that identifies issues associated with developing a national evaluation, measurement and verification (EM&V) standard for end-use, non-transportation, energy efficiency activities. The objectives of this study are to identify the scope of such a standard and define EM&V requirements and issues that will need to be addressed in a standard. To explore these issues, we provide and discuss: (1) a set of definitions applicable to an EM&V standard; (2) a literature review of existing guidelines, standards, and 'initiatives' relating to EM&V standards as well as a review of 'bottom-up' versus 'top-down' evaluation approaches; (3) a summary of EM&V related provisions of two recent federal legislative proposals (Congressman Waxman's and Markey's American Clean Energy and Security Act of 2009 and Senator Bingaman's American Clean Energy Leadership Act of 2009) that include national efficiency resource requirements; (4) an annotated list of issues that that are likely to be central to, and need to be considered when, developing a national EM&V standard; and (5) a discussion of the implications of such issues. There are three primary reasons for developing a national efficiency EM&V standard. First, some policy makers, regulators and practitioners believe that a national standard would streamline EM&V implementation, reduce costs and complexity, and improve comparability of results across jurisdictions; although there are benefits associated with each jurisdiction setting its own EM&V requirements based on their specific portfolio and evaluation budgets and objectives. Secondly, if energy efficiency is determined by the US Environmental Protection Agency to be a Best Available Control Technology (BACT) for avoiding criteria pollutant and/or greenhouse gas emissions, then a standard can be required for documenting the emission reductions resulting from efficiency actions. The third reason for a national EM&V standard is that such a standard is likely to be required as a result of future federal energy legislation that includes end-use energy efficiency, either as a stand-alone energy-efficiency resource standard (EERS) or as part of a clean energy or renewable energy standard. This study is focused primarily on this third reason and thus explores issues associated with a national EM&V standard if energy efficiency is a qualifying resource in federal clean energy legislation. Developing a national EM&V standard is likely to be a lengthy process; this study focuses on the critical first step of identifying the issues that must be addressed in a future standard. Perhaps the most fundamental of these issues is 'how good is good enough?' This has always been the fundamental issue of EM&V for energy efficiency and is a result of the counter-factual nature of efficiency. Counter-factual in that savings are not measured, but estimated to varying degrees of accuracy by comparing energy consumption after a project (program) is implemented with what is assumed to have been the consumption of energy in the absence of the project (program). Therefore, the how good is good enough question is a short version of asking how certain does one have to be of the energy savings estimate that results from EM&V activities and is that level of certainty properly balanced against the amount of effort (resources, time, money) that is utilized to obtain that level of certainty. The implication is that not only should energy efficiency investments be cost-effective, but EM&V investments should consider risk management principles and thus also balance the costs and value of information derived from EM&V (EM&V should also be cost-effective).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multipath star switch controller

Device concept permits parallel computers to scan several commonnetwork-connected data stations at maximum rate. Sequencers leap-frog to bypass ports already being serviced by another computer. Two-path system for 16-port star switch controller is cost effective if added bandwidth or increased reliability is desired. Triple-path system would be cost effective for 32-port controller.

Anderson, T. O.↗

Simplifying Energy Efficiency for Homeowners - Results from a California Utility's Pilot Study of a Scalable Solution to Assess Retrofit and Solar Opportunities: Preprint

For homeowners, typical choices to reduce net energy use in their homes include: upgrading their home with a tailored efficiency retrofit or investing in roof-top solar. Determining the unique combination of these options that will provide the most cost-effective solution requires analysis for each home. This analysis needs to be presented in a simple and actionable way to homeowners. The solution should also be easily scalable to thousands of homes to enable utilities to better target efficiency program options and support solar installations. Sacramento Municipal Utility District (SMUD) piloted a new tool developed by Vistar Energy called XeroHome that automates the assessment of energy efficiency and solar opportunities in existing homes. XeroHome demonstrates an approach to using building energy modeling, energy use data analytics and homeowner engagement to identify and target energy efficiency opportunities at scale. XeroHome uses automation to build an EnergyPlus model for each home, based on information from public data sources such as property assessment records, building permit records, aerial/satellite photography, and template models derived from ResStock. Utilizing cloud computing, machine learning and optimization algorithms, energy upgrade packages are ranked by cost-effectiveness for each home and presented over an interactive web-portal. This paper discusses SMUD's pilot project using XeroHome to conduct analysis for 1,500 existing homes in Sacramento, CA. Development of XeroHome's advanced analytics capabilities are discussed in the context of applicability for utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplifying Energy Efficiency for Homeowners - Results from a California Utility's Pilot Study of a Scalable Solution to Assess Retrofit and Solar Opportunities

For homeowners, typical choices to reduce net energy use in their homes include: upgrading their home with a tailored efficiency retrofit or investing in roof-top solar. Determining the unique combination of these options that will provide the most cost-effective solution requires analysis for each home. This analysis needs to be presented in a simple and actionable way to homeowners. The solution should also be easily scalable to thousands of homes to enable utilities to better target efficiency program options and support solar installations. Sacramento Municipal Utility District (SMUD) piloted a new tool developed by Vistar Energy called XeroHome that automates the assessment of energy efficiency and solar opportunities in existing homes. XeroHome demonstrates an approach to using building energy modeling, energy use data analytics and homeowner engagement to identify and target energy efficiency opportunities at scale. XeroHome uses automation to build an EnergyPlus model for each home, based on information from public data sources such as property assessment records, building permit records, aerial/satellite photography, and template models derived from ResStock. Utilizing cloud computing, machine learning and optimization algorithms, energy upgrade packages are ranked by cost-effectiveness for each home and presented over an interactive web-portal. This paper discusses SMUD's pilot project using XeroHome to conduct analysis for 1,500 existing homes in Sacramento, CA. Development of XeroHome's advanced analytics capabilities are discussed in the context of applicability for utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗