Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Correcting Type Ia Supernova Distances for Selection Biases and Contamination in Photometrically Identified Samples

We present a new technique to create a bin-averaged Hubble diagram (HD) from photometrically identified SN Ia data. The resulting HD is corrected for selection biases and contamination from core-collapse (CC) SNe, and can be used to infer cosmological parameters. This method, called “BEAMS with Bias Corrections” (BBC), includes two fitting stages. The first BBC fitting stage uses a posterior distribution that includes multiple SN likelihoods, a Monte Carlo simulation to bias-correct the fitted SALT-II parameters, and CC probabilities determined from a machine-learning technique. The BBC fit determines (1) a bin-averaged HD (average distance versus redshift), and (2) the nuisance parameters α and β, which multiply the stretch and color (respectively) to standardize the SN brightness. In the second stage, the bin-averaged HD is fit to a cosmological model where priors can be imposed. We perform high-precision tests of the BBC method by simulating large (150,000 event) data samples corresponding to the Dark Energy Survey Supernova Program. Our tests include three models of intrinsic scatter, each with two different CC rates. In the BBC fit, the SALT-II nuisance parameters α and β are recovered to within 1% of their true values. In the cosmology fit, we determine the dark energy equation of state parameter w using a fixed value of Ω{sub M} as a prior: averaging over all six tests based on 6 × 150,000 = 900,000 SNe, there is a small w-bias of 0.006±0.002. Finally, the BBC fitting code is publicly available in the SNANA package.

79 ASTRONOMY AND ASTROPHYSICS↗

A background correction algorithm for Van Allen Probes MagEIS electron flux measurements

We describe an automated computer algorithm designed to remove background contamination from the Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) electron flux measurements. We provide a detailed description of the algorithm with illustrative examples from on-orbit data. We find two primary sources of background contamination in the MagEIS electron data: inner zone protons and bremsstrahlung X-rays generated by energetic electrons interacting with the spacecraft material. Bremsstrahlung X-rays primarily produce contamination in the lower energy MagEIS electron channels (~30–500 keV) and in regions of geospace where multi-M eV electrons are present. Inner zone protons produce contamination in all MagEIS energy channels at roughly L < 2.5. The background-corrected MagEIS electron data produce a more accurate measurement of the electron radiation belts, as most earlier measurements suffer from unquantifiable and uncorrectable contamination in this harsh region of the near-Earth space environment. These background-corrected data will also be useful for spacecraft engineering purposes, providing ground truth for the near-Earth electron environment and informing the next generation of spacecraft design models (e.g., AE9).

47 OTHER INSTRUMENTATION↗

A statistical analysis of the COHERENT data and applications to new physics

The observation of coherent elastic neutrino nucleus scattering (CEvNS) by the COHERENT collaboration in 2017 has opened a new window to both test Standard Model predictions at relatively low energies and probe new physics scenarios. Our investigations show, however, that a careful treatment of the statistical methods used to analyze the data is essential to derive correct constraints and bounds on new physics parameters. In this manuscript we perform a detailed analysis of the publicly available COHERENT CsI data making use of all available background data. We point out that Wilks’ theorem is not fulfilled in general and a calculation of the confidence regions via Monte Carlo simulations following a Feldman-Cousins procedure is necessary. As an example for the necessity of this approach to test new physics scenarios we quantify the allowed ranges for several scenarios with neutrino non-standard interactions. Furthermore, we provide accompanying code to enable an easy implementation of other new physics scenarios as well as data files of our results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Locality-aware and load-balanced static task scheduling for MapReduce

Task scheduling for MapReduce jobs has been an active area of research with the objective of decreasing the amount of data transferred during the shuffle phase via exploiting data locality. In the literature, generally only the scheduling of reduce tasks is considered with the assumption that scheduling of map tasks is already determined by the input data placement. However, in cloud or HPC deployments of MapReduce, the input data is located in a remote storage and scheduling map tasks gains importance. Here, we propose models for simultaneous scheduling of map and reduce tasks in order to improve data locality and balance the processors’ loads in both map and reduce phases. Our approach is based on graph and hypergraph models which correctly encode the interactions between map and reduce tasks. Partitions produced by these models are decoded to schedule map and reduce tasks. A two-constraint formulation utilized in these models enables balancing processors’ loads in both map and reduce phases. The partitioning objective in the hypergraph models correctly encapsulates the minimization of data transfer when a local combine step is performed prior to shuffle, whereas the partitioning objective in the graph models achieve the same feat when a local combine is not performed. Here, we show the validity of our scheduling on the MapReduce parallelizations of two important kernel operations – sparse matrix–vector multiplication (SpMV) and generalized sparse matrix–matrix multiplication (SpGEMM) – that are widely encountered in big data analytics and scientific computations. Compared to random scheduling, our models lead to tremendous savings in data transfer by reducing data traffic from several hundreds of megabytes to just a few megabytes in the shuffle phase and consequently leading up to 2.6x and 4.2x speedup for SpMV and SpGEMM, respectively.

97 MATHEMATICS AND COMPUTING↗

A method to correct coordinate distortion in EBSD maps

Drift during electron backscatter diffraction mapping leads to coordinate distortions in resulting orientation maps, which affects, in some cases significantly, the accuracy of analysis. A method, thin plate spline, is introduced and tested to correct such coordinate distortions in the maps after the electron backscatter diffraction measurements. The accuracy of the correction as well as theoretical and practical aspects of using the thin plate spline method is discussed in detail. By comparing with other correction methods, it is shown that the thin plate spline method is most efficient to correct different local distortions in the electron backscatter diffraction maps. - Highlights: • A new method is suggested to correct nonlinear spatial distortion in EBSD maps. • The method corrects EBSD maps more precisely than presently available methods. • Errors less than 1–2 pixels are typically obtained. • Direct quantitative analysis of dynamic data are available after this correction.

36 MATERIALS SCIENCE↗

New JAM Global Analysis of Spin-Dependent PDFs

We present the results of a new global next-to-leading order analysis of spin-dependent parton distribution functions from the most recent world data on polarized deep-inelastic scattering (DIS) and pp collisions, focusing in particular on the large-x and low-Q2 regions. By directly fitting DIS polarization asymmetries, we eliminate biases introduced by using polarized structure function data extracted under nonuniform assumptions for the unpolarized structure functions. For analysis of the large-x data, we implement nuclear smearing corrections for deuterium and 3He nuclei, and systematically include target mass and higher twist corrections to the g1 and g2 structure functions at low Q2. We also explore the effects of Q2 and W2 cuts in the data sets, and the potential impact of future data on the behavior of the spin-dependent parton distributions at intermediate and large x.

Melnitchouk, Wolodymyr↗

Large-scale real-time signal processing in physics experiments: the ALICE TPC FPGA pipeline

For LHC Run 3, the ALICE Time Projection Chamber was upgraded to operate in continuous readout mode. Interaction rates of up to 50 kHz in Pb-Pb collisions require real-time processing of more than 3 TB s -1 of raw detector data. This requirement is met by a custom FPGA-based processing pipeline that performs the complete front-end data treatment fully in-stream, including common-mode correction, pedestal subtraction, ion-tail filtering, zero suppression, and dense data packing. A central element of the design is a highly parallel common-mode correction algorithm operating directly on the streaming data. It robustly identifies signal-free readout channels on a time-bin basis and applies pad-dependent scaling to compensate for local variations in capacitive coupling in the GEM readout. In combination with pedestal subtraction and ion-tail filtering, this enables accurate baseline restoration under extreme high-occupancy conditions, preventing signal loss while efficiently suppressing noise prior to zero suppression. The pipeline operates continuously at the full detector bandwidth and reduces the raw input rate of approximately 3 TB s -1 to about 900 GBps for Pb-Pb collisions at the target interaction rate. Overall, it represents a large-scale FPGA-based real-time signal-processing implementation for high-energy physics detector readout.

Digital signal processing (DSP)↗

Correction to ‘Twenty-five years of Genomes OnLine Database (GOLD): data updates and new features in v.9’

In the originally published online version of this manuscript, there were two co-authors missing from the author list: Tanja Woyke (https://orcid.org/0000-0002-9485-5637) and Emiley Eloe-Fadrosh (https://orcid.org/0000-0002-8162-1276). The author list should read: ‘Supratim Mukherjee, Dimitri Stamatis, Cindy Tianqing Li, Galina Ovchinnikova, Jon Bertsch, Jagadish Chandrabose Sundaramurthi, Mahathi Kandimalla, Paul A. Nicolopoulos, Alessandro Favognano, Tanja Woyke, Emiley A. Eloe-Fardosh, I-Min A. Chen, Nikos C. Kyrpides and T.B.K. Reddy’. This emendation is outlined only in this correction notice to preserve the version of record.

99 GENERAL AND MISCELLANEOUS↗

A BAYESIAN METHOD FOR THE INTERCALIBRATION OF SPECTRA IN REVERBERATION MAPPING

Flux calibration of spectra in reverberation mapping (RM) is most often performed by assuming the flux constancy of some specified narrow emission lines, which stem from an extended region that is sometimes partially spatially resolved, in contrast to the point-like broad-line region and the central continuum source. The inhomogeneous aperture geometries used among different observation sets in a joint monitoring campaign introduce systematic deviations to the fluxes of broad lines and central continuum, and intercalibration over these data sets is required. As an improvement to the previous empirical correction performed by comparing the (nearly) contemporaneous observation points, we describe a feasible Bayesian method that obviates the need for (nearly) contemporaneous observations, naturally incorporates physical models of flux variations, and fully takes into account the measurement errors. In particular, it fits all the data sets simultaneously regardless of samplings and makes use of all of the information in the data sets. A Markov Chain Monte Carlo implementation is employed to recover the parameters and uncertainties for intercalibration. Application to the RM data sets of NGC 5548 with joint monitoring shows the high fidelity of our method.

79 ASTRONOMY AND ASTROPHYSICS↗

Bias Correcting NOAA's High-Resolution Rapid Refresh (HRRR) Wind Resource Data for Grid Integration Applications [Slides]

Many weather years of high-quality wind data are widely accepted in the grid integration community to be important for studying wind energy technical potential, energy system operations, and grid resilience. NREL makes high-quality wind and solar resource data available. NREL's Grid-Atmosphere workshop (March 2024) identified NREL National Solar Radiation Database as widely used in grid integration modeling, but there is less agreement on commonly used wind datasets. One important factor identified by ESIG's 2023 report 'Weather Dataset Needs for Planning and Analyzing Modern Power Systems' for gold standard wind data is regular updates. To address the need for regular updates, NREL's team can now process all currently available and regularly updated High-Resolution Rapid Refresh (HRRR) outputs. HRRR is an hourly-updated operational forecast product produced by the National Oceanic and Atmospheric Administration (NOAA) (Dowell et al., 2022). One barrier to NREL using HRRR is systematic bias and consistency with NREL's existing wind datasets (e.g. WIND Toolkit, 'WTK') across weather years. To address this barrier, we show that the HRRR can be interpolated and bias-corrected to be consistent with NRE's existing datasets. We call the new dataset BC-HRRR (bias-corrected HRRR). As with historical datasets like the WTK, BC-HRRR is intended for use in grid integration modeling (e.g., capacity expansion, production cost, and resource adequacy modeling). BC-HRRR's (2015-present) consistency with WTK (2007-2013) allows NREL to extend internal grid integration tooling with 15+ weather years of wind data with low-overhead extensibility to future years as they are made available by NOAA. The rest of this slide deck documents the BC-HRRR processing methods, validation, and its implications for intended use.

17 WIND ENERGY↗

Prompt Gamma Analysis of Hanford 3013 Containers. Final Report

Prompt gamma analysis was completed on 1,947 oxide and 310 metal Hanford 3013 containers. This report discusses the method used to analyze the gamma-ray spectra for the 3013 containers and determine the light element impurities present in the material and their respective concentrations. The light elements sensitive to this method include aluminum, beryllium, boron, chlorine, fluorine, magnesium, phosphorus, potassium and sodium. The results from the analyses are used to link the containers to representative materials in the MIS program whose storage behavior is known. The results are also used to place containers in surveillance bins based on their expected behavior in storage. The results indicate definite trends between the impurities detected and the material’s process history. However, unexpected impurities were found in some process groups suggesting that the material is not well characterized by process history in all cases. In addition, it was found that the spectrum names were incorrectly assigned to the data files due to an electronics issue. Therefore, spectrum name corrections were made to 258 containers Hanford data set, and the effect of those changes on container representation are also discussed.

Mgmt Of Radioactive & Non-radioactive Wastes from ↗

Corrective Action Investigation Plan for Corrective Action Unit 413: Clean Slate II Plutonium Dispersion (TTR) Tonopah Test Range, Nevada (Rev. 1)

Corrective Action Unit (CAU) 413 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 413 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate II (CSII) storage–transportation test conducted on May 31, 1963. CAU 413 includes one corrective action site (CAS), TA-23-02CS (Pu Contaminated Soil). The known releases at CAU 413 are the result of the atmospheric deposition of contamination from the 1963 CSII test. The CSII test was a non-nuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 2 feet of soil. This test dispersed radionuclides, primarily plutonium, on the ground surface. The presence and nature of contamination at CAU 413 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 17, 2015, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 413. The CAI will include radiological surveys, geophysical surveys, collection and analyses of soil samples, and assessment of investigation results. The collection of soil samples will be accomplished using both probabilistic and judgmental sampling approaches. To facilitate site investigation and the evaluation of DQO decisions, the releases at CAU 413 have been divided into seven study groups.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Investigation Plan for Corrective Action Unit 414: Clean Slate III Plutonium Dispersion (TTR) Tonopah Test Range, Nevada, Revision 1

Corrective Action Unit (CAU) 414 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 414 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate III (CSIII) storage–transportation test conducted on June 9, 1963. CAU 414 includes one corrective action site (CAS), TA-23-03CS (Pu Contaminated Soil). The known releases at CAU 414 are the result of the atmospheric dispersal of contamination from the 1963 CSIII test. The CSIII test was a nonnuclear detonation of a nuclear device located inside a reinforced concrete bunker covered with 8 feet of soil. This test dispersed radionuclides, primarily uranium and plutonium, on the ground surface. The presence and nature of contamination at CAU 414 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 7, 2016, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective action alternatives for CAU 414.

54 ENVIRONMENTAL SCIENCES↗

Avoiding erroneous analysis of MIM diode current-voltage characteristics through exponential fitting

Accurate fitting of measured current-voltage [$I$ ($V$) ] data is crucial to the correct analysis and understanding of metal-insulator–metal (MIM) diodes, especially for optical rectennas. With the commonly used polynomial fitting of the $I$$(V)$ data, the order of the fit can drastically affect the diode performance metrics such as resistance, responsivity, and asymmetry. Additionally, the resulting fitting coefficients provide no useful parameters. An exponential-based equation can fit the $I$$(V)$ data well, can avoid artifacts from the choice of order of the polynomial, and allows for the accurate calculation of diode performance metrics directly from the fitting coefficients. Finally, connecting the performance metrics to fitting coefficients shows a correspondence between zero-bias responsivity and asymmetry at any given voltage.

42 ENGINEERING↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

Complete Monte Carlo Simulation of Neutron Scattering Experiments

In the far past, it was not possible to accurately correct for the finite geometry and the finite sample size of a neutron scattering set-up. The limited calculation power of the ancient computers as well as the lack of powerful Monte Carlo codes and the limitation in the data base available then prevented a complete simulation of the actual experiment. Using e.g. the Monte Carlo neutron transport code MCNPX [1], neutron scattering experiments can be simulated almost completely with a high degree of precision using a modern PC, which has a computing power that is ten thousand times that of a super computer of the early 1970s. Thus, (better) corrections can also be obtained easily for previous published data provided that these experiments are sufficiently well documented. Better knowledge of reference data (e.g. atomic mass, relativistic correction, and monitor cross sections) further contributes to data improvement. Elastic neutron scattering experiments from liquid samples of the helium isotopes performed around 1970 at LANL happen to be very well documented. Considering that the cryogenic targets are expensive and complicated, it is certainly worthwhile to improve these data by correcting them using this comparatively straightforward method. As two thirds of all differential scattering cross section data of {sup 3}He(n,n){sup 3}He are connected to the LANL data, it became necessary to correct the dependent data measured in Karlsruhe, Germany, as well. A thorough simulation of both the LANL experiments and the Karlsruhe experiment is presented, starting from the neutron production, followed by the interaction in the air, the interaction with the cryostat structure, and finally the scattering medium itself. In addition, scattering from the hydrogen reference sample was simulated. For the LANL data, the multiple scattering corrections are smaller by a factor of five at least, making this work relevant. Even more important are the corrections to the Karlsruhe data due to the inclusion of the missing outgoing self-attenuation that amounts to up to 15%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System and method for generating motion corrected tomographic images

A method and related system for generating motion corrected tomographic images includes the steps of illuminating a region of interest (ROI) to be imaged being part of an unrestrained live subject and having at least three spaced apart optical markers thereon. Simultaneous images are acquired from a first and a second camera of the markers from different angles. Motion data comprising 3D position and orientation of the markers relative to an initial reference position is then calculated. Motion corrected tomographic data obtained from the ROI using the motion data is then obtained, where motion corrected tomographic images obtained therefrom.

47 OTHER INSTRUMENTATION↗