Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condition monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Autonomous planetary rover at Carnegie Mellon

This report describes progress in research on an autonomous robot for planetary exploration. In 1989, the year covered by this report, a six-legged walking robot, the Ambler, was configured, designed, and constructed. This configuration was used to overcome shortcomings exhibited by existing wheeled and walking robot mechanisms. The fundamental advantage of the Ambler is that the actuators for body support are independent of those for propulsion; a subset of the planar joints propel the body, and the vertical actuators support and level the body over terrain. Models of the Ambler's dynamics were developed and the leveling control was studied. An integrated system capable of walking with a single leg over rugged terrain was implemented and tested. A prototype of an Ambler leg is suspended below a carriage that slides along rails. To walk, the system uses a laser scanner to find a clear, flat foothold, positions the leg above the foothold, contacts the terrain with the foot, and applies force enough to advance the carriage along the rails. Walking both forward and backward, the system has traversed hundreds of meters of rugged terrain including obstacles too tall to step over, trenches too deep to step in, closely spaced rocks, and sand hills. In addition, preliminary experiments were conducted with concurrent planning and execution, and a leg recovery planner that generates time and power efficient 3D trajectories using 2D search was developed. A Hero robot was used to demonstrate mobile manipulation. Indoor tasks include collecting cups from the lab floor, retrieving printer output, and recharging when its battery gets low. The robot monitors its environment, and handles exceptional conditions in a robust fashion, using vision to track the appearance and disappearance of cups, onboard sonars to detect imminent collisions, and monitors to detect the battery level.

Whittaker, William↗

Empirical profiling of cold hydrogen plumes formed from venting of LH 2 storage vessels

Liquid hydrogen (LH 2 ) storage is viewed as a viable approach to assure sufficient hydrogen capacity at commercial fuelling stations. Presently, LH 2 is produced at remote facilities and then transported to the end-use site by road vehicles (i.e., LH 2 tanker trucks). Venting of hydrogen to depressurize the transport storage tank is a routine part of the LH 2 delivery and site transfer process. The behavior of cold hydrogen plumes has not been well characterized because of the sparsity of empirical field data, which can lead to overly conservative safety requirements. Committee members of the National Fire Protection Association (NFPA) Standard 2 [1] formed the Hydrogen Storage Safety Task Group, which consists of hydrogen producers, safety experts, and computational fluid dynamics modellers, has identified the lack of understanding of hydrogen dispersion during LH 2 venting of storage vessels as a critical gap for establishing safety distances at LH 2 facilities, especially commercial hydrogen fuelling stations. To address this need, the National Renewable Energy Laboratory Sensor Laboratory, in collaboration with the NFPA Hydrogen Storage Task Group, developed a prototype Cold Hydrogen Plume Analyzer to empirically characterize the hydrogen plume formed during LH 2 storage tank venting. The prototype analyzer was field deployed during an actual LH 2 venting process. Critical findings included: hydrogen above the lower flammable limit (LFL) was detected as much as 2 m lower than the release point, which is not predicted by existing models; personal monitors detected hydrogen at ground level, although at levels below the LFL; a small but inconsistent correlation was found between oxygen depletion and the hydrogen concentration; a negligible to non-existent correlation was found between in-situ temperature measurements and the hydrogen concentration. The prototype analyzer is being upgraded for enhanced metrological capabilities, including improved real-time spatial and temporal profiling of hydrogen plumes and tracking of prevailing weather conditions. Additional deployments are planned to monitor plume behavior under different wind, humidity, and temperature conditions. The data will be shared with the Hydrogen Storage Task Group and ultimately will be used support theoretical models and code requirements prescribed in NFPA 2.

08 HYDROGEN↗

Durability testing at one atmosphere of advanced catalysts and catalyst supports for automotive gas turbine engine combustors, part 1

The durability of catalysts and catalyst supports in a combustion environment was experimentally demonstrated. A test of 1000 hours duration was completed with two catalysts, using diesel fuel and operating at catalytically supported thermal combustion conditions. The performance of the catalysts was determined by monitoring emissions throughout the test, and by examining the physical condition of the catalyst core at the conclusion of the test. The test catalysts proved to be capable of low emissions operation after 1000 hours diesel aging, with no apparent physical degradation of the catalyst support.

Heck, R. M.↗

Durability testing at 5 atmospheres of advanced catalysts and catalyst supports for gas turbine engine combustors

The durability of CATCOM catalysts and catalyst supports was experimentally demonstrated in a combustion environment under simulated gas turbine engine combustor operating conditions. A test of 1000 hours duration was completed with one catalyst using no. 2 diesel fuel and operating at catalytically-supported thermal combustion conditions. The performance of the catalyst was determined by monitoring emissions throughout the test, and by examining the physical condition of the catalyst core at the conclusion of the test. Tests were performed periodically to determine changes in catalytic activity of the catalyst core. Detailed parametric studies were also run at the beginning and end of the durability test, using no. 2 fuel oil. Initial and final emissions for the 1000 hours test respectively were: unburned hydrocarbons (C3 vppm):0, 146, carbon monoxide (vppm):30, 2420; nitrogen oxides (vppm):5.7, 5.6.

Olson, B. A.↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Tonopah Test Range Air Monitoring: CY2020 Meteorological, Radiological, and Wind Transported Particulate Observations

In 1963, the U.S. Department of Energy (DOE) (formerly the Atomic Energy Commission [AEC]), implemented Operation Roller Coaster on the Tonopah Test Range (TTR) and an adjacent area of the Nevada Test and Training Range (NTTR) (formerly the Nellis Air Force Range). This operation resulted in radionuclide-contaminated soils at the Double Tracks site and Clean Slate I, II, and III sites. This report documents observations made during ongoing monitoring of radiological, meteorological, and dust conditions at stations installed adjacent to the Clean Slate sites and at the TTR Sandia National Laboratories (SNL) Range Operations Center (ROC). The monitoring effort supports the DOE Office of Legacy Management in its stewardship of the Clean Slate sites as part of their mission to protect human health and the environment at sites of former nuclear device development and testing. Specific monitoring objectives include determining if wind blowing across the Clean Slate sites is transporting particles of radionuclide-contaminated soil beyond the physical and administrative boundaries of the sites, and providing information for planning long-term stewardship of the sites.

54 ENVIRONMENTAL SCIENCES↗

Feasibility Study of a Rotorcraft Health and Usage Monitoring System ( HUMS): Usage and Structural Life Monitoring Evaluation

The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FLS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques. The data that was used for the evaluation of the usage monitoring techniques was collected under an independent HUMS Flight trial program, using a commercially available HUMS and data recording system. The usage data collect from the HUMS trial aircraft was analyzed off-line using PC-based software that included the FCR and FLS techniques. In the future, if the technique prove feasible, usage monitoring would be incorporated into the onboard HUMS.

Dickson, B.↗

Feasibility Study of a Rotorcraft Health and Usage Monitoring System (HUMS): Usage and Structural Life Monitoring Evaluation

The objective of this study was to evaluate two techniques, Flight Condition Recognition (FCR) and Flight Load Synthesis (FIS), for usage monitoring and assess the potential benefits of extending the retirement intervals of life-limited components, thus reducing the operator's maintenance and replacement costs. Both techniques involve indirect determination of loads using measured flight parameters and subsequent fatigue analysis to calculate the life expended on the life-limited components. To assess the potential benefit of usage monitoring, the two usage techniques were compared to current methods of component retirement. In addition, comparisons were made with direct load measurements to assess the accuracy of the two techniques.

Dickson, B.↗

Multifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR-II Probe

Contrasted with imaging in the visible (400–650 nm) and near-infrared window I (NIR-I, 650–900 nm) regions, imaging in near-infrared window II (NIR-II, 1000–1700 nm) is a highly promising in vivo imaging modality with improved resolution and deeper tissue penetration. Here, a small molecule NIR-II dye,5,5'-(1H,5H-benzo[1,2-c:4,5-c'] bis[1,2,5]thiadiazole)-4,8-diyl)bis(N,N-bis(4-(3-((tert-butyldimethylsilyl)oxy)propyl)phenyl) thiophen-2-amine), is successfully encapsulated into phospholipid vesicles to prepare a probe CQS1000. The novel NIR-II probe is studied for in vivo multifunctional biological imaging. The results of this study indicate that the NIR-II vesicle CQS1000 can noninvasively and dynamically visualize and monitor many physiological and pathological conditions of circulatory systems, including lymphatic drainage and routing, angiogenesis of tumor, and vascular deformity such as arterial thrombus formation and ischemia with high spatial and temporal resolution. More importantly, by virtue of the favorable half-life of blood circulation of CQS1000, NIR-II imaging is capable of aiding precise resection of tumor such as osteosarcoma and accelerating the process of lymph node dissection to complete sentinel lymph node biopsy for better decision making during the tumor surgery. Overall, CQS1000 is a highly promising NIR-II probe for multifunctional biomedical imaging in physiological and pathological conditions, surpassing traditional NIR-I imaging modality and pathologic assessments for clinical diagnosis and treatment.

36 MATERIALS SCIENCE↗

Radiative transfer in shrub savanna sites in Niger: Preliminary results from HAPEX-Sahel. Part 3: Optical dynamics and vegetation index sensitivity to biomass and plant cover

A shrub savannah landscape in Niger was optically characterized utilizing blue, green, red and near-infrared wavelengths. Selected vegetation indices were evaluated for their performance and sensitivity to describe the complex Sahelian soil/vegetation canopies. Bidirectional reflectance factors (BRF) of plants and soils were measured at several view angles, and used as input to various vegetation indices. Both soil and vegetation targets had strong anisotropic reflectance properties, rendering all vegetation index (6) responses to be a direct function of sun and view geometry. Soil background influences were shown to alter the response of most vegetation indices. N-space greenness had the smallest dynamic range in VI response, but the n-space brightness index provided additional useful information. The global environmental monitoring index (GEMI) showed a large 6 dynamic range for bare soils, which was undesirable for a vegetation index. The view angle response of the normalized difference vegetation index (NDVI), atmosphere resistant vegetation index (ARVI) and soil atmosphere resistant vegetation index (SARVI) were asymmetric about nadir for multiple view angles, and were, except for the SARVI, altered seriously by soil moisture and/or soil brightness effects. The soil adjusted vegetation index (SAVI) was least affected by surface soil moisture and was symmetric about nadir for grass vegetation covers. Overall the SAVI, SARVI and the n-space vegetation index performed best under all adverse conditions and were recommended to monitor vegetation growth in the sparsely vegetated Sahelian zone.

vanLeeuwen, W. J. D.↗

Evidence of Au(111) topological states in a kagome analogue lattice and their robustness beyond ultra-low temperatures and defect-free conditions

The experimental realization of kagome lattices that exhibit the predicted coexistence of topological states with high electron kinetics and non-dispersing quantum states remains challenging. Additionally, the robustness of these states against structural perturbations has rarely been explored. Here, we report on the formation of an analogue kagome structure via the electrostatic self-assembly of 4,7-dibromobenzo[c]-1,2,5-thiadiazole (2Br-BTD) molecules on Au(111). Local spectroscopic measurements, supported by theoretical calculations, reveal that the weak molecular coupling reshapes the topological-induced Shockley surface state of Au(111) by imposing a (7 × 7) periodicity, resulting in new band crossings. The molecular overlayer favours the opening of electron gaps at these positions manifested as sharp peaks in dI/dV spectra and electron localization in either the hexagonal or triangular sublattices of the kagome structure. To explore the robustness of these topological states, we monitored their stability under varied conditions, including different temperatures, the unaltered herringbone reconstruction of the Au(111) surface and local structural relaxation of the molecular assembly. These results demonstrate the degree of topological protection of these states, which holds potential for fundamental and applied research.

Austin, Dave [University of Central Florida, Orlan↗

Method and apparatus for conducting structural health monitoring in a cryogenic, high vibration environment

Sensors affixed to various such structures, where the sensors can withstand, remain affixed, and operate while undergoing both cryogenic temperatures and high vibrations. In particular, piezoelectric single crystal transducers are utilized, and these sensors are coupled to the structure via a low temperature, heat cured epoxy. This allows the transducers to monitor the structure while the engine is operating, even despite the harsh operating conditions. Aspects of the invention thus allow for real time monitoring and analysis of structures that operate in conditions that previously did not permit such analysis. A further aspect of the invention relates to use of piezoelectric single crystal transducers. In particular, use of such transducers allows the same elements to be used as both sensors and actuators.

Qing, Xinlin↗

Intelligent Control and Health Monitoring

Advanced model-based control architecture overcomes the limitations state-of-the-art engine control and provides the potential of virtual sensors, for example for thrust and stall margin. "Tracking filters" are used to adapt the control parameters to actual conditions and to individual engines. For health monitoring standalone monitoring units will be used for on-board analysis to determine the general engine health and detect and isolate sudden faults. Adaptive models open up the possibility of adapting the control logic to maintain desired performance in the presence of engine degradation or to accommodate any faults. Improved and new sensors are required to allow sensing at stations within the engine gas path that are currently not instrumented due in part to the harsh conditions including high operating temperatures and to allow additional monitoring of vibration, mass flows and energy properties, exhaust gas composition, and gas path debris. The environmental and performance requirements for these sensors are summarized.

Sanjay Garg↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

Absence of arterial baroreflex modulation of skin sympathetic activity and sweat rate during whole-body heating in humans

1. Prior findings suggest that baroreflexes are capable of modulating skin blood flow, but the effects of baroreceptor loading/unloading on sweating are less clear. Therefore, this project tested the hypothesis that pharmacologically induced alterations in arterial blood pressure in heated humans would lead to baroreflex-mediated changes in both skin sympathetic nerve activity (SSNA) and sweat rate. 2. In seven subjects mean arterial blood pressure was lowered (approximately 8 mmHg) and then raised (approximately 13 mmHg) by bolus injections of sodium nitroprusside and phenylephrine, respectively. Moreover, in a separate protocol, arterial blood pressure was reduced via steady-state administration of sodium nitroprusside. In both normothermia and heat-stress conditions the following responses were monitored: sublingual and mean skin temperatures, heart rate, beat-by-beat blood pressure, skin blood flow (laser-Doppler flowmetry), local sweat rate and SSNA (microneurography from peroneal nerve). 3. Whole-body heating increased skin and sublingual temperatures, heart rate, cutaneous blood flow, sweat rate and SSNA, but did not change arterial blood pressure. Heart rate was significantly elevated (from 74 +/- 3 to 92 +/- 4 beats x min(-1); P < 0.001) during bolus sodium nitroprusside-induced reductions in blood pressure, and significantly reduced (from 92 +/- 4 to 68 +/- 4 beats x min(-1); P < 0.001) during bolus phenylephrine-induced elevations in blood pressure, thereby demonstrating normal baroreflex function in these subjects. 4. Neither SSNA nor sweat rate was altered by rapid (bolus infusion) or sustained (steady-state infusion) changes in blood pressure regardless of the thermal condition. 5. These data suggest that SSNA and sweat rate are not modulated by arterial baroreflexes in normothermic or moderately heated individuals.

Clinical Trial↗

Monitor support on accelerated processing device

A technique for implementing synchronization monitors on an accelerated processing device (“APD”) is provided. Work on an APD includes workgroups that include one or more wavefronts. All wavefronts of a workgroup execute on a single compute unit. A monitor is a synchronization construct that allows workgroups to stall until a particular condition is met. Responsive to all wavefronts of a workgroup executing a wait instruction, the monitor coordinator records the workgroup in an “entry queue.” The workgroup begins saving its state to a general APD memory and, when such saving is complete, the monitor coordinator moves the workgroup to a “condition queue.” When the condition specified by the wait instruction is met, the monitor coordinator moves the workgroup to a “ready queue,” and, when sufficient resources are available on a compute unit, the APD schedules the ready workgroup for execution on a compute unit.

42 ENGINEERING↗

Background Free‐Tropospheric Ice Nucleating Particle Concentrations at Mixed‐Phase Cloud Conditions

Abstract Clouds containing ice are vital for precipitation formation and are important in determining the Earth's radiative budget. However, primary formation of ice in clouds is not fully understood. In the presence of ice nucleating particles (INPs), the phase change to ice is promoted, but identification and quantification of INPs in a natural environment remains challenging because of their low numbers. In this paper, we quantify INP number concentrations in the free troposphere (FT) as measured at the High Altitude Research Station Jungfraujoch (JFJ), during the winter, spring, and summer of the years 2014–2017. INPs were measured at conditions relevant for mixed‐phase cloud formation at T = 241/242 K. To date, this is the longest timeline of semiregular measurements akin to online INP monitoring at this site and sampling conditions. We find that INP concentrations in the background FT are on average capped at 10/stdL (liter of air at standard conditions [ T = 273 K and p = 1013 hPa]) with an interquartile range of 0.4–9.6/stdL, as compared to measurements during times when other air mass origins (e.g., Sahara or marine boundary layer) prevailed. Elevated concentrations were measured in the field campaigns of 2016, which might be due to enhanced influence from Saharan dust and marine boundary layer air arriving at the JFJ. The upper limit of INP concentrations in the background FT is supported by measurements performed at similar conditions, but at different locations in the FT, where we find INP concentrations to be below 13/stdL most of the time.

54 ENVIRONMENTAL SCIENCES↗

Optimization of the x-ray monitoring angle for creating a correlation model between internal and external respiratory signals

Purpose: To perform dynamic tumor tracking irradiation with the Vero4DRT (MHI-TM2000), a correlation model [four dimensional (4D) model] between the displacement of infrared markers on the abdominal wall and the three-dimensional position of a tumor indicated by a minimum of three implanted gold markers is required. However, the gold markers cannot be detected successfully on fluoroscopic images under the following situations: (1) overlapping of the gold markers; and (2) a low intensity ratio of the gold marker to its surroundings. In the present study, the authors proposed a method to readily determine the optimal x-ray monitoring angle for creating a 4D model utilizing computed tomography (CT) images. Methods: The Vero4DRT mounting two orthogonal kV x-ray imaging subsystems can separately rotate the gantry along an O-shaped guide-lane and the O-ring along its vertical axis. The optimal x-ray monitoring angle was determined on CT images by minimizing the root-sum-square of water equivalent path lengths (WEPLs) on the orthogonal lines passing all of the gold markers while rotating the O-ring and the gantry. The x-ray monitoring angles at which the distances between the gold markers were within 5 mm at the isocenter level were excluded to prevent false detection of the gold markers in consideration of respiratory motions. First, the relationship between the WEPLs (unit: mm) and the intensity ratios of the gold markers was examined to assess the validity of our proposed method. Second, our proposed method was applied to the 4D-CT images at the end-expiration phase for 11 lung cancer patients who had four to five gold markers. To prove the necessity of the x-ray monitoring angle optimization, the intensity ratios of the least visible markers (minimum intensity ratios) that were estimated from the WEPLs were compared under the following conditions: the optimal x-ray monitoring angle and the angles used for setup verification. Additionally, the intra- and interfractional variations in the intensity ratio were examined from the optimal x-ray monitoring angle. Results: A negative strong correlation was observed between the WEPL (x) and the intensity ratio (y) (y= 6.57 exp[-0.0125x]+ 1, R=-0.88 [95% confidence interval: -0.85 to -0.90], p < 0.01). Our proposed method effectively avoided having the x-ray beam pass through high-density structures, although there were large interpatient variations in the optimal x-ray monitoring angle because of the geometric arrangement between the gold markers and the anatomical structures. The minimum intensity ratios that were estimated from the WEPLs at the optimal x-ray monitoring angle ranged from 1.43 to 2.48, which was an average of 1.27 times (range, 1.02-1.66) higher than the angles used for setup verification. The maximum intra- and interfractional decreases in the intensity ratio were 0.23 and 0.17, respectively. Conclusions: The authors demonstrated that the optimal x-ray monitoring angle for creating a 4D model can improve the visibility of gold markers.

60 APPLIED LIFE SCIENCES↗