Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of software models for energy savings from cool roofs

For this study, a web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savings to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Finally, radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine-learning modeling of magnetization dynamics in quasi-equilibrium and driven metallic spin systems

Here, we present a perspective on recent progress in machine-learning (ML) force-field approaches for large-scale Landau–Lifshitz–Gilbert (LLG) simulations of metallic spin systems. Building on a generalization of the Behler–Parrinello (BP) architecture originally developed for quantum molecular dynamics, we develop scalable and transferable ML models that faithfully capture the complex, environment-dependent electron-mediated exchange fields characteristic of itinerant magnets. A central ingredient of this framework is the implementation of symmetry-aware magnetic descriptors based on group-theoretical bispectrum formalisms. Leveraging these ML force fields, LLG simulations faithfully reproduce hallmark non-collinear magnetic orders—such as the 120° and tetrahedral states—on the triangular lattice, and successfully capture the complex spin textures emerging in the mixed-phase states of a square-lattice double-exchange model under thermal quench. We further discuss a generalized potential theory that extends the BP formalism to incorporate both conservative and nonconservative electronic torques, thereby enabling ML models to learn nonequilibrium exchange fields from computationally demanding microscopic approaches such as nonequilibrium Green’s-function techniques. This extension yields quantitatively accurate predictions of voltage-driven domain-wall motion and establishes a foundation for quantum-accurate, multiscale modeling of nonequilibrium spin dynamics and spintronic functionalities.

Descriptors↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗

On estimating cosmology-dependent covariance matrices

We describe a statistical model to estimate the covariance matrix of matter tracer two-point correlation functions with cosmological simulations. Assuming a fixed number of cosmological simulation runs, we describe how to build a 'statistical emulator' of the two-point function covariance over a specified range of input cosmological parameters. Because the simulation runs with different cosmological models help to constrain the form of the covariance, we predict that the cosmology-dependent covariance may be estimated with a comparable number of simulations as would be needed to estimate the covariance for fixed cosmology. Our framework is a necessary first step in planning a simulations campaign for analyzing the next generation of cosmological surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of soiling and weathering on the albedo of building envelope materials: Lessons learned from natural exposure in two European cities and tuning of a laboratory simulation practice

Chemical and physical stress, weathering, organic and inorganic matter deposition, and microbial growth over time, or “aging”, affect the optical-radiative performance of building envelope materials. Natural exposure helps to quantify these effects, but it usually requires several years. Further, the contribution of the different degradation agents cannot be isolated, and results from different campaigns cannot be easily compared because of the variability in the boundary conditions producing aging. Here in this paper we present an adaptation of the protocol implemented by ASTM as D7897-18 “Standard Practice for Laboratory Soiling and Weathering of Roofing Materials to Simulate Effects of Natural Exposure on Solar Reflectance and Thermal Emittance”. The aim is to reproduce in the laboratory the changes in albedo (solar reflectance) and thermal emittance experienced by building envelope materials in European urban areas rather than in the United States. We tuned the spraying duration and weathering cycles, and we compared the UV–vis–NIR reflectances of naturally-aged specimens (48 months in Rome and Milan) of roofing and wall finish materials to those exposed to laboratory weathering and soiling. Excluding those materials that show early physical-chemical degradation, the mean absolute deviation between natural and laboratory exposure of roofing products is equal to 0.027 in albedo. This is a lower value than the differences between two natural exposure campaigns at the same site. We clearly defined the limits of application of the protocol, providing an appraisal of the repeatability of natural aging. Moreover, we identified possible improvements in the methodology to conduct both natural and laboratory exposure.

36 MATERIALS SCIENCE↗

Estimating the value of jointly optimized electric power generation and end use: a study of ISO-scale load shaping applied to the residential building stock

A generation-to-load simulation estimated the impact, in terms of production costs and CO2 emissions, attributable to the joint optimization of electric power generation and flexible end uses to support increasing penetrations of renewable energy. Newly conceived, evaluated, and foundational in developing a U.S. National Standard was a transaction-less yet continuous demand response system based on a day-ahead optimum load shape (OLS) designed to encourage Internet-connected devices to autonomously and voluntarily explore options to favour lowest cost generators - without requiring two-way communications, personally identifiable information, or customer opt-in. Boundary conditions used for model calibration included historical weather, residential building stock construction attributes, home appliance and device empirical operating schedules, prototypical power distribution feeder models, thermal generator heat rates, startup and ramping constraints, and fuel costs. Results of an hourly-based annual case study of Texas indicate a 1/3 reduction in production costs and a 1/5 reduction in CO2 emissions are possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Capabilities of Behind-the-Meter Solar-plus-Storage for Providing Backup Power during Long-Duration Power Interruptions [Slides]

The study estimates the performance of behind-the-meter solar PV-plus-energy-storage-systems (PVESS) in providing critical-load or whole-building backup across a wide range of geographies, building types, and power interruption conditions. The study also considers a set of 10 historical long-duration power outage events and evaluates how PVESS could have performed in providing backup power during those specific events. The analysis is the first in what will be a series of studies by Berkeley Lab, in collaboration with the National Renewable Energy Laboratory, on the use of PVESS for backup power. This initial study, which relies on simulated end-use level building loads, solar generation, and storage dispatch, is intended to provide a baseline set of performance estimates and to illustrate key performance drivers.

14 SOLAR ENERGY↗

Quantum Hamiltonian Physics with Supercomputers

The vision of solving the nuclear many-body problem in a Hamiltonian framework with fundamental interactions tied to QCD via Chiral Perturbation Theory is gaining support. The goals are to preserve the predictive power of the underlying theory, to test fundamental symmetries with the nucleus as laboratory and to develop new understandings of the full range of complex quantum phenomena. Advances in theoretical frameworks (renormalization and many-body methods) as well as in computational resources (new algorithms and leadership-class parallel computers) signal a new generation of theory and simulations that will yield profound insights into the origins of nuclear shell structure, collective phenomena and complex reaction dynamics. Fundamental discovery opportunities also exist in such areas as physics beyond the Standard Model of Elementary Particles, the transition between hadronic and quark–gluon dominated dynamics in nuclei and signals that characterize dark matter. I will review some recent achievements and present ambitious consensus plans along with their challenges for a coming decade of research that will build new links between theory, simulations and experiment. Opportunities for graduate students to embark upon careers in the fast developing field of supercomputer simulations is also discussed.

Physics↗

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.↗

Studying methane migration mechanisms at Walker Ridge, Gulf of Mexico, via 3D methane hydrate reservoir modeling

We have developed a 3D methane hydrate reservoir simulator to model marine methane hydrate systems. Our simulator couples highly nonlinear heat and mass transport equations and includes heterogeneous sedimentation, in-situ microbial methanogenesis, the influence of pore size contrast on solubility gradients, and the impact of salt exclusion from the hydrate phase on dissolved methane equilibrium in pore water. Using environmental parameters from Walker Ridge in the Gulf of Mexico, we first simulate hydrate formation in and around a thin, dipping, planar sand stratum surrounded by clay lithology as it is buried to 295mbsf. We find that with sufficient methane being supplied by organic methanogenesis in the clays, a 200x pore size contrast between clays and sands allows for a strong enough concentration gradient to significantly drop the concentration of methane hydrate in clays immediately surrounding a thin sand layer, a phenomenon that is observed in well log data. Building upon previous work, our simulations account for the increase in sand-clay solubility contrast with depth from about 1.6% near the top of the sediment column to 8.6% at depth, which leads to a progressive strengthening of the diffusive flux of methane with time. By including an exponentially decaying organic methanogenesis input to the clay lithology with depth, we see a decrease in the aqueous methane supplied to the clays surrounding the sand layer with time, which works to further enhance the contrast in hydrate saturation between the sand and surrounding clays. Significant diffusive methane transport is observed in a clay interval of about 11m above the sand layer and about 4m below it, which matches well log observations. The clay-sand pore size contrast alone is not enough to completely eliminate hydrate (as observed in logs), because the diffusive flux of aqueous methane due to a contrast in pore size occurs slower than the rate at which methane is supplied via organic methanogenesis. Therefore, it is likely that additional mechanisms are at play, notably bound water activity reduction in clays. Three-dimensionality allows for inclusion of lithologic heterogeneities, which focus fluid flow and subsequently allow for heterogeneity in the methane migration mechanisms that dominate in marine sediments at a local scale. Incorporating recently acquired 3D seismic data from Walker Ridge to inform the lithologic structure of our modeled reservoir, we show that even with deep adjective sourcing of methane along highly permeable pathways, local hydrate accumulations can be sourced either by diffusive or advective methane flux; advectively-sourced hydrates accumulate evenly in highly permeable strata, while diffusively-sourced hydrates are characterized by thin strata-bound intervals with high clay-sand pore size contrasts.

Nole, Michael↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Failure investigation of nuclear grade POCO graphite target in high energy neutrino physics through numerical simulation

In many high energy physics neutrino beamlines, targets are made up of isotropic POCO graphite grade for production of neutrinos for high energy particle physics research and are bombarded with highly energetic pulsed proton beam. The pulsed proton beam with a small beam size creates thermal stress waves as well as radiation damage such as displacement damage, void formation, swelling, and gas formation amongst others. As a result, after a few years of operation one of the longest operated targets appears to have undergone bulk swelling and fractured along the beam centerline. A complex interaction of dynamic loading due to beam, material degradation due to irradiation are thought to have caused such a failure. Here, we present a numerical simulation to capture the combined effects of swelling and the dynamic effect of thermal stress waves due to beam heating, to explain the failure of target. An empirical formula has been developed to take into account swelling as a function of temperature and proton fluence and has been implemented in a commercial finite element code. Extensive X-ray diffraction (XRD) were performed on graphite samples from the failed target to understand the lattice parameter changes due to irradiation and build a valid empirical model. Simulation results show that swelling plays a major role in elevating the stress state in the material exceeding the failure strength while the pulsed beam heating also introduces fatigue loading that would explain brittle fracture emanating from inside of the material and propagating outward. Such empirical formulations will help in identifying the threshold values of critical parameters to extend the service life of future multi-megawatt neutrino targets and targets in other accelerator environments.

43 PARTICLE ACCELERATORS↗

Twenty Years On!: Updating the IEA BESTEST Building Thermal Fabric Test Cases for ASHRAE Standard 140

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and the informative example results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Energy Savings Measures for Building Retrofits in an Interactive Workshop Environment

As part of the Better Buildings Summit 2025, a workshop was developed to simulate the decision process for implementing a set of energy savings measures on an existing building. As part of the workshop a "game" was created around energy savings strategies, and workshop participants selected renovation cards that provided data around the impacts of that renovation choice. Participants then were able to calculate overall savings and payback from the selected retrofit opportunities. This publication has been produced to package the resources used in the activity in an organized document so that the materials can be distributed and reused more broadly. It provides a comprehensive framework for replicating the workshop, including step-by-step instructions, retrofit "game cards" with data points, and facilitation guidance. By using these materials, readers can conduct their own version of this interactive workshop with stakeholders in their networks, such as building owners, energy managers, or policy makers. The goal is to empower users to simulate the decision-making processes for energy projects, foster collaboration, and drive meaningful discussions around cost-effective retrofit opportunities and goal-oriented outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Ensemble Generation for Improved Characterization of Representing Geologic Variability in a Reservoir: IBDP Case Study for SMART Initiative

This document is a poster covering the findings from activities on training data generation, specifically geologic ensemble generation. The generated geologic realizations captured the range of possible permeability distributions of the subsurface at the Illinois Basin - Decatur Project (IBDP) site, based on available well log variabilities. The percentages of reservoirs and baffles in the injection zone and a truncation of baffle permeability led to more variance in the simulations. This will be used to build forward modeling, history matching, and optimization workflows. The geologic realizations were also ranked according to dynamic measures of hydraulic diffusivity, and simulations confirm a greater contrast between the reservoir and the baffles during injection.

stochastic ensemble generation↗

Data Sets for Evaluation of Building Fault Detection and Diagnostics Algorithms

This documentation and dataset can be used to test the performance of automated fault detection and diagnostics algorithms for buildings. The dataset was created by LBNL, PNNL, NREL, ORNL and ASHRAE RP-1312 (Drexel University). It includes data for air-handling units and rooftop units simulated with PNNL's large office building model.

AHU↗