Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Development of an Ultra-wide band Receiver for the North America Array

The North America Array (NAA), also known as the next-generation Very Large Array (ngVLA), is a concept for a radio astronomical interferometric array operating in the frequency range 1.2 GHz to 116 GHz and designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage while reducing operational costs compared to the current Jansky Very Large Array (JVLA). At JPL, we are designing a single receiver package designed to operate across the 8 to 48 GHz frequency range, in contrast to the current JVLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs. We are developing a prototype integrated feed-receiver package with a system noise temperature that meets the requirements of the ngVLA/NAA primary science programs, with a design that meets the requirement of low long-term operational costs. The receiver package being developed at JPL consists of a feed horn, low-noise amplifier (LNA), and down-converters to analog intermediate frequencies. We report on the status of this receiver package development.

Lazio, Joseph↗

Multimessenger Gravitational-wave Searches with Pulsar Timing Arrays: Application to 3C 66B Using the NANOGrav 11-year Data Set

When galaxies merge, the supermassive black holes in their centers may form binaries and emit low-frequency gravitational radiation in the process. In this paper, we consider the galaxy 3C 66B, which was used as the target of the first multimessenger search for gravitational waves. Due to the observed periodicities present in the photometric and astrometric data of the source, it has been theorized to contain a supermassive black hole binary. Its apparent 1.05-year orbital period would place the gravitational-wave emission directly in the pulsar timing band. Since the first pulsar timing array study of 3C 66B, revised models of the source have been published, and timing array sensitivities and techniques have improved dramatically. With these advances, we further constrain the chirp mass of the potential supermassive black hole binary in 3C 66B to less than (1.65±0.02)×109Me using data from the NANOGrav 11-year data set. This upper limit provides a factor of 1.6 improvement over previous limits and a factor of 4.3 over the first search done. Nevertheless, the most recent orbital model for the source is still consistent with our limit from pulsar timing array data. In addition, we are able to quantify the improvement made by the inclusion of source properties gleaned from electromagnetic data over “blind” pulsar timing array searches. With these methods, it is apparent that it is not necessary to obtain exact a priori knowledge of the period of a binary to gain meaningful astrophysical inferences.

Zaven Arzoumanian↗

Experimental Validation of Swarm Array Results Using Mars Cube One (Marco) A,B Downlink Signals

In this paper, we investigate the feasibility of calibrating an orbiting phased array composed of CubeSat class spacecraft together with a larger reference (or “chief”) spacecraft, comprising an overall Swarm Array. Considered as an analog to the Deep Space Network (DSN) Uplink Arraying problem [1], a spaceborne Swarm Array that can potentially deliver comparable or even greater operational performance than large monolithic spacecraft (such as increased data rates for telecommunications, or greater baselines for improved spatial resolution), thus increasing future mission capability but with significantly enhanced flexibility, evolvability and robustness.

Kahan, Daniel↗

Astrophysics Milestones for Pulsar Timing Array Gravitational-wave Detection

The NANOGrav Collaboration reported strong Bayesian evidence for a common-spectrum stochastic process in its12.5 yr pulsar timing array data set, with median characteristic strain amplitude at periods of a year of A(yr) = 1.92(+0.75,-0.55) x 10^(-15). However, evidence for the quadrupolar Hellings & Downs interpulsar correlations, which are characteristic of gravitational-wave signals, was not yet significant. We emulate and extend the NANOGrav data set, injecting a wide range of stochastic gravitational-wave background(GWB)signals that encompass a variety of amplitudes and spectral shapes, and quantify three key milestones.(I)Given the amplitude measured in the 12.5 yr analysis and assuming this signal is a GWB, we expect to accumulate robust evidence of an interpulsar-correlated GWB signal with 15–17 yr of data, i.e., an additional 2–5 yr from the 12.5 yr data set.(II)At the initial detection, we expect a fractional uncertainty of 40% on the power-law strain spectrum slope, which is sufficient to distinguish a GWB of supermassive black hole binary origin from some models predicting more exotic origins.(III)Similarly, the measured GWB amplitude will have an uncertainty of 44% upon initial detection, allowing us to arbitrate between some population models of supermassive black hole binaries. In addition, power-law models are distinguishable from those having low-frequency spectral turnovers once 20 yr of data are reached. Even though our study is based on the NANOGrav data, we also derive relations that allow for a generalization to other pulsar timing array data sets. Most notably, by combining the data of individual arrays into the International Pulsar Timing Array, all of these milestones can be reached significantly earlier.

Nihan S. Pol↗

Antennas, Arrays, and Systems for Submillimter-Wave Radio Astronomy

In this paper we present the design and development of a 16-pixel submillimeter-wave array instrument using SIS technology. We show that this instrument concept demonstration and component development dramatically simplifies the fabrication, assembly, and integration of large focal plane arrays at these frequencies. This advancement is enabled by the innovative array architecture with silicon microlens based antenna arrays, highly sensitive SIS mixers at these frequencies, integrated SiGe BiCMOS based low-noise intermediate frequency (IF) amplifiers, and silicon micromachined packaging.

Chattopadhyay, Goutam↗

Experimental Validation of Swarm Array Results Using Mars Cube One (MarCO) A,B Downlink Signals

In this paper, we investigate the feasibility of calibrating an orbiting phaased array composed of CubeSat class spacecraft together with a larger reference (or “chief”) spacecraft, comprising an overall Swarm Array. Considered as an analog to the Deep Space Network (DSN) Uplink Arraying problem [1], a spaceborne Swarm Array that can potentially deliver comparable or even greater operational performance than large monolithic spacecraft (such as increased datarates for telecommunications, or greater baselines for improved spatial resolution), thus increasing future mission capability but with significantly enhanced flexibility, evolvability and robustness.

Vilnrotter, Victor↗

Infrared Imaging using Sparse Microresonator Arrays and Compressed Sensing

In this work, we present an uncooled infrared (IR) thermal imager featuring a sparse array of resonant pixels that can be monolithically integrated with the readout electronics for long-term operation in high-temperature environments. Each of the detector pixels is made of an IR-sensitive GaN microresonator developed to be operated at up to 500 0C. The pixels are employed in sparse array configuration to allow for routing the signal carrying traces and to ease the routing from pixel to circuit, as well as to reduce the power consumption at the expense of moderate post-processing time and increased complexity to recover the image. Three 128 by 128 sparse resonator arrays with the array densities of 10%, 25% and 37.5% are designed, and used in conjunction with the Compressed Sensing (CS) method to reconstruct complex test images from highly incomplete data. Capabilities and performance metrics of the recovery technique are explored.

Rais-Zadeh, Mina↗

Thermal Infrared Detector Sparse Array for NASA Planetary Applications

In this work, we present an uncooled infrared (IR) thermal imager featuring a sparse array of resonant pixels that can be monolithically integrated with the readout electronics for long-term operation in hightemperature environments. Each of the detector pixels is made of an IR-sensitive GaN microresonator developed to be operated at up to 500 0C. The pixels are employed in sparse array configuration to allow for routing the signal carrying traces and to ease the routing from pixel to circuit, as well as to reduce the power consumption. A 128´128 sparse resonator array with the array density of 37.5% is designed and used in conjunction with the Compressed Sensing method to reconstruct complex test images from highly incomplete data. Capabilities and performance metrics of the recovery technique are explored.

Rais-Zadeh, Mina↗

Space Technology Mission Directorate - Game Changing Development Program - Vertical Solar Array Technology Project

The Vertical Solar Array Technology (VSAT) project is focused on the development of solar array technologies necessary for sustained presence on the lunar surface circa 2028. Existing solar array structures and deployment system technologies are designed for either zero-g or horizontal surface deployment. VSAT will explore vertical array deployment on extension masts of up to 10m in length in order to capture near continuous sun light at the lunar south pole.

GCD↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Development of the Microcalorimeter Array for the Line Emission Mapper (LEM) X-Ray Probe

The Line Emission Mapper (LEM) is a proposed NASA probe-class mission designed to study the formation of structure in the Universe. LEM will have a 14k pixel array of transition-edge sensor (TES) microcalorimeters that provide a spectral resolution of < 2.5 eV and a bandpass of 0.2-2 keV. In this paper, we report on the status and plan for continued development of the LMS microcalorimeter. This includes details of the TES and x-ray absorber design, and the measured performance in prototype arrays. We present a detailed budget for the energy resolution and show how the properties of the LEM pixels are well optimized for the baseline time-division-multiplexing (TDM) that will be used read out the array. Finally, we describe the design and performance of the first full scale LMS arrays which include the necessary mechanical and electrical interfaces needed for LEM and are a precursor to an engineering model detector.

Stephen J Smith↗

Efficient Mirrorlet Array Based Integral Field Spectrometer for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based Integral Field Spectrometer (IFS) has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, concurrently adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces Needed detector pixel numbers, but also reduce the high communication rate demanding for much a large multiple instrument mission. The basic idea of the efficient lenslet/mirrorlet array IFS is to design a lenslet/mirrorlet array in such a way that the images from multiple mirrorlets are grouped and aligned as a spectrum from a single slit. Therefore, the number of detector rows used to prevent wavelength crosstalk is no longer needed. This paper is also going to address how to lay the traces on the detector and what is the difference from the traditional lenslet IFS. Our goal is to show that such an IFS is capable to lay all spectral traces onto a 2k x 2k detector array using HWO NIR requirement that has a higher spectral resolving power R = 70 and a large Field of View (FOV) of 96 λ/D.

Exoplanet↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

Configurable luminaire with light sources variably oriented with respect to an array of concave mirrors

An array of LEDs is supported by a support mechanism that both supports conductors leading to the LEDs and sinks heat from the LEDs. The support mechanism may be a transparent heat-conducting sheet or an array of cantilevered arms at different angles that support the LEDs and sink heat. This reduces the blockage of light. The LEDs are positioned generally in the focal plane of an array of concave mirrors that collimate the light. The LEDs and array of mirrors are translatable with respect to one another to steer the aggregate light beam to customize the emission. The LEDs may be variably oriented with respect to the associated mirror apertures so as to create different light beams emitted from different ones of the mirrors.

42 ENGINEERING↗

Planar electrode arrays and fabrication methods thereof

The present invention relates to a method of fabricating an electrode array, in which an underlying handle wafer is removed to provide a planar device having the electrode array. Also provided are wafers including a plurality of planar devices having an electrode array, as well as sensors including such an electrode array.

Schindelholz, Eric John↗

Method of depositing nanoparticles on an array of nanowires

This disclosure provides systems, methods, and apparatus related to nanostructures. In one aspect, an array of nanowires is provided. The array of nanowires comprises a plurality of nanowires. End of nanowires of the plurality of nanowires are attached to a substrate. A liquid including a plurality of nanoparticles is deposited on the array of nanowires. The liquid is evaporated from the array of nanowires. Nanoparticles of the plurality of nanoparticles are deposited on the nanowires as a meniscus of the liquid recedes along lengths of the plurality of nanowires.

Yang, Peidong↗

Wavelength selective filtering with non-radial array of microstructure elements

A non-radial array of microstructure elements provides enhanced wavelength selective filtering. The elements are arranged along a line that does not intersect the center of the core. In this configuration, the first coupling element in an array that is nearest to the core is a non-integer array unit spacing from the main waveguide where the array unit spacing is defined as the flat to flat distance of a hexagonal cell.

Kiani, Leily S.↗

Analysis of a Continuous Halbach Array Permanent Magnet Motor for Electric Vehicles

Permanent magnets spirals with continuously varying magnetization directions to replace Halbach arrays have recently been developed. Ideal sinusoidal fields with the desired polarity are created in the machine airgap. In this paper we propose to compare a motor initially designed with a conventional discrete Halbach array with the innovative continuous Halbach array magnets. The continuous Halbach array comprises bonded magnets manufactured from anisotropic powder aligned and compacted without a bonding agent. The paper focuses on the impact of using these magnets on the performance of a motor designed for electric vehicle applications using 2D and 3D FEA simulations. The baseline motor is a 50-kW outrunner motor designed for light duty electric vehicles

Rallabandi, Vandana↗