Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “analytical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Blockchain-based decentralized computing

An exemplary blockchain-based decentralized computing system and method are disclosed for industrial analytics applications. The exemplary system and method leverage blockchain technology to deliver and execute privacy-preserving decentralized predictive analytics, machine learning, and optimization operations for various industrial applications using a set of self-contained analytics block smart contracts that can be readily utilized and in analytics applications to deploy across multiple sites.

Ramanan, Paritosh P.↗

Time correlations from steady-state expectation values

Recovering properties of correlation functions is typically challenging. On one hand, experimentally, it requires measurements with a temporal resolution finer than the system's dynamics. On the other hand, analytical or numerical analysis requires solving the system evolution. Here, we use recent results of quantum metrology with continuous measurements to derive general lower bounds on the relaxation and second-order correlation times that are both easy to calculate and measure. These bounds are based solely on steady-state expectation values and their derivatives with respect to a control parameter, and can be readily extended to the autocorrelation of arbitrary observables. We validate our method on two examples of critical quantum systems: a critical driven-dissipative resonator, where the bound matches analytical results for the dynamics, and the infinite-range Ising model, where only the steady state is solvable and thus the bound provides information beyond the reach of existing analytical approaches. Our results can be applied to experimentally characterize ultrafast systems, and to theoretically analyze many-body models with dynamics that are analytically or numerically hard.

Górecki, Wojciech [INFN, Pavia]↗

Time correlations from steady-state expectation values

Recovering properties of correlation functions is typically challenging. On one hand, experimentally, it requires measurements with a temporal resolution finer than the system's dynamics. On the other hand, analytical or numerical analysis requires solving the system evolution. Here, we use recent results of quantum metrology with continuous measurements to derive general lower bounds on the relaxation and second-order correlation times that are both easy to calculate and measure. These bounds are based solely on steady-state expectation values and their derivatives with respect to a control parameter, and can be readily extended to the autocorrelation of arbitrary observables. We validate our method on two examples of critical quantum systems: a critical driven-dissipative resonator, where the bound matches analytical results for the dynamics, and the infinite-range Ising model, where only the steady state is solvable and thus the bound provides information beyond the reach of existing analytical approaches. Our results can be applied to experimentally characterize ultrafast systems, and to theoretically analyze many-body models with dynamics that are analytically or numerically hard.

Górecki, Wojciech [INFN, Pavia]↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Influence of Carbon-Nitride Dot-Emitting Species and Evolution on Fluorescence-Based Sensing and Differentiation

Carbon dots have attracted widespread interest for sensing applications based on their low cost, ease of synthesis, and robust optical properties. We investigate structure–function evolution on multiemitter fluorescence patterns for model carbon-nitride dots (CNDs) and their implications on trace-level sensing. Hydrothermally synthesized CNDs with different reaction times were used to determine how specific functionalities and their corresponding fluorescence signatures respond upon the addition of trace-level analytes. Archetype explosives molecules were chosen as a testbed due to similarities in substituent groups or inductive properties (i.e., electron withdrawing), and solution-based assays were performed using ratiometric fluorescence excitation–emission mapping (EEM). Analyte-specific quenching and enhancement responses were observed in EEM landscapes that varied with the CND reaction time. We then used self-organizing map models to examine EEM feature clustering with specific analytes. Finally, the results reveal that interactions between carbon-nitride frameworks and molecular-like species dictate response characteristics that may be harnessed to tailor sensor development for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spray Mechanism of Contained-Electrospray Ionization

Analytical characteristics of contained electrospray ionization (ESI) are summarized in terms of its potential to modify the analyte solution during the stages of droplet formation to provide opportunities to generate native versus denatured biomolecular gas-phase ions, without the need for bulk-phase analyte modifications. The real-time modification of the charged microdroplets occurs in a cavity that is included in the outlet of the contained-ESI ion source. Close examination of the inside of the cavity using a high-speed camera revealed the formation of discrete droplets as well as thin liquid films in the droplets wake. When operated at 20 psi N2 pressure, the droplets were observed to move at an average speed of 8 mm/s providing ~1 s mixing time in a 10 mm cavity length. Evidence is provided for the presence of highly reactive charged droplets based on myoglobin charge state distribution, apo-myoglobin contents, and ion mobility drift time profiles under different spray conditions. Mechanistic insights for the capture of vapor-phase reagents and droplet dynamics as influenced by different operational modes are also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparing π‐complexation capabilities of ionic liquids containing silver(I) and copper(I) ions by headspace single drop microextraction in combination with high‐performance liquid chromatography

Selective π‐complexation capabilities of silver(I) and copper(I) ions can be effectively facilitated in ionic liquids. To understand the effects of environmental factors that influence the π‐complexation of these metal ions with analytes, techniques that employ small volumes of ionic liquid that can be readily analyzed are desired. In this study, headspace single drop microextraction coupled with HPLC is used to investigate a diverse set of environmental factors on the metal ion‐mediated complexation with aromatic compounds in ionic liquid media. Silver(I) and copper(I) bis[(trifluoromethyl)sulfonyl]imide salts were both studied by dissolving them in the 1‐decyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ionic liquid and employing the mixture as extraction media for aromatic compounds. Water and acetonitrile within the sample solution were observed to interfere with the complexation of silver(I) ions and aromatic compounds, while ethylene glycol and triethylene glycol did not. The temperature and extraction times were optimized to fully facilitate the π‐complexation capabilities of metal ions in ionic liquid media. Partition coefficients between the sample headspace and metal ion were determined using a three‐phase equilibria model. Although no discernable difference in analyte partitioning between the headspace and ionic liquid solvent was observed, analyte partition coefficients to silver(I) ion tended to be greater compared to copper(I) ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

A machine learning approach to fracture mechanics problems

Analytical and empirical solutions to engineering problems are usually preferred because of their convenience in applications. However, they are not always accessible in complex problems. A new class of solutions, based on machine learning (ML) models such as regression trees and neural networks (NNs), are proposed and their feasibility and value are demonstrated through the analysis of fracture toughness measurements. It is found that both solutions based on regression trees and NNs can provide accurate results for the specific problem, but NN-based solutions outperform regression-tree-based solutions in terms of their simplicity. Here this example demonstrates that ML solutions are a major improvement over analytical and empirical solutions in terms of both reliable functionality and rapid deployment. When analytical solutions are not available, the use of ML solutions can overcome the limitations of empirical solutions and substantially change the way that engineering problems are solved.

36 MATERIALS SCIENCE↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A review of rare earth elements and yttrium in coal ash: Content, modes of occurrences, combustion behavior, and extraction methods

Rare earth elements and yttrium (REY) have attracted considerable attention over the last decade because of their vital roles in clean energy, consumer product, national defense and security applications, among other uses. Due to the retention of REY during coal burning, coal combustion ash is considered as potential alternative sources for REY. Understanding the content, speciation, retention and/or transformation behavior of REY during coal combustion not only expands our knowledge of the combustion behavior of the trace elements in coal, but also provides basis for modeling REY partitioning during coal combustion and for developing economically viable REY recovery technologies. This review makes a critical summary of recent progress in the study of REY in coal ash. The contents and the extraction potentials of REY in coal ash derived from 15 major coal-producing countries worldwide were summarized and evaluated. Various analytical methods for determining REY bulk contents and speciation, together with the solid sample pretreatment, analytical accuracy and precision, advantages and disadvantages were summarized and compared. Modern analytical approaches combined indirect methods (e.g., sequential extraction) shed light on the physical distribution, mineralogy, and the chemical state of REY in coal ash. Three types of REY occurrences in coal ash, including Si-Al glassy association, discrete minerals or compounds, and organic association (bound with unburned carbon) were defined in the review. The glassy association can be further divided into REY minerals closely bound to glass phases and dispersed throughout the glassy structure. REY partitioning in various emission streams, the size distribution, and their enrichment behavior in coal ash were discussed. Additionally, thermal behavior and transformation of various REY forms in coal during combustion process, including organic-associated REY, REY phosphates, REY carbonates, clay-bound REY and among others were summarized. Two possible retention mechanisms of REY by aluminosilicate glass at boiler temperature were proposed: the incorporation of the individual REY phases into the glass as inclusions and the diffusion of REY phases throughout Si-Al glass structures in the melting process. Feed coal mineral types, mineral-mineral associations, boiler conditions, and other factors control the retention process. After coal combustion, the speciation of REY in fly ash may be modified by the reactions of REY phases with flue gas components. Further, an overview of REY transformation mechanisms during coal combustion was deeply discussed. Finally, current extraction techniques for REY recovery from coal combustion ash were introduced. Future outlooks and research problems were also identified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrodeposited nickel coatings for exceptional corrosion mitigation in industrial grade molten chloride salts for concentrating solar power

Molten chloride salt eutectics are attractive candidates for use as thermal energy storage media and heat transfer fluids in generation-three concentrating solar thermal power (Gen3 CSP) plants. However, corrosion of alloys in molten chloride salts, especially at high temperatures, is an extremely challenging problem that studies focus on lower temperatures, shorter durations, or analytical grade, and high-purity, salts. To date, there has been no study on corrosion or corrosion mitigation in an industrial-grade salt at a high temperature such as 750 °C. To alleviate this knowledge gap, the study presents new multiscale fractal-textured Ni coatings on various alloy surfaces for effective corrosion mitigation at 750 °C in molten chloride salts. Using the electrodeposition method, durable double-layer textured coatings were formed on stainless steel alloys (SS316, SS310, and SS347) and In800H. The corrosion performance of the coatings is investigated in both analytical-grade purity and, for the first time, practically relevant industrial-grade chloride salts. Ni-coated ferrous alloys showed an exceptionally reduced corrosion rate in the range of 350–480 μm/y in analytical-grade salts, and between 450 and 490 μm/y in purified industrial-grade salts at 750 °C. Ni coatings on ferrous alloys reduced corrosion rates by as much as 70% compared to uncoated surfaces and were comparable to the expensive Ha230 alloy with a high Ni content. As a result, by the use of innovative fractal corrosion mitigation coatings, for the first time, low-cost structural alloys are rendered viable for use with industrial-grade chloride salts, which is profoundly beneficial in practical systems.

14 SOLAR ENERGY↗

Combining Mass Spectrometry of Picoliter Samples with a Multicompartment Electrodynamic Trap for Probing the Chemistry of Droplet Arrays

Single droplet levitation provides contactless access to the microphysical and chemical properties of micrometer-sized samples. Most applications of droplet levitation to chemical and biological systems use nondestructive optical techniques to probe droplet properties. To provide improved chemical specificity, we coupled a multicompartment quadrupole electrodynamic trap (QET) with single droplet mass spectrometry. Our QET continuously traps a monodisperse droplet population (tens to hundreds of droplets) and allows for the simultaneous sizing of a single droplet using its Mie scattering pattern. Single droplets are subsequently ejected into the ionization region of an ambient pressure inlet mass spectrometer. We optimized two complementary soft ionization techniques for picoliter aqueous droplets: (1) paper spray (PS) ionization and (2) thermal desorption glow discharge (TDGD) ionization. Both techniques detect oxygenated organic acids in single droplets, with signal-to-noise ratios >100 and detection limits on the order of 10 pg. Sensitivity and reproducibility across single droplets are driven by the droplet deposition location and spray stability in PS-MS and the ionization region humidity and analyte evaporation rate in TDGD-MS. Importantly, the analyte evaporation rate can control the TDGD-MS quantitative capability because high evaporation rates result in significant ion suppression. Additionally, this effect is mitigated by optimizing the vaporization temperature, droplet size range, and analyte volatility. We demonstrate quantitative and reproducible measurements with a droplet internal standard (<10% RSD) and compare the sensitivity of PS-MS and TDGD-MS. Finally, we demonstrate the application of QET-MS to the study of heterogeneous chemical kinetics with the reaction of gas phase O 3 and aqueous maleic acid droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Method Optimization for Sampling and Analysis Instrumentation

This work presents a generalized approach for analytical method optimization that branches the gap between techniques historically employed and accurate modern optimization techniques suitable for various applications. The novelty of the described strategy is the utilization of multivariate, multiobjective optimization with Karush-Kuhn-Tucker conditions to bound the optimization space to solutions within the physical limitations of instrumentation. Briefly, the basic steps outlined in this paper are to (1) determine the objective(s) that should be maximized or minimized based on the goals of the analytical application, (2) conduct a screening experiment, (3) perform ANOVA to determine the parameters which have a statistically significant effect on the objective, (4) conduct an experiment (e.g., Box-Behnken design) to collect data for fitting the objective equation, and (5) determine the physical constraints of the parameters and solve the Lagrangian to determine the optimal method parameters. A broad approach to optimization target selection allows for robust method tuning to develop improved data sets amenable for chemometrics and machine learning algorithm development. Gas chromatography-mass spectrometry was selected as a use case due to its broad use across scientific fields and time-consuming method development involving numerous parameters. In conclusion, this strategy can reduce the cost of research, improve data quality, and enable the rapid development of new analytical technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Fast-Pass, Desorption Electrospray Ionization Mass Spectrometry Strategy for Untargeted Metabolic Phenotyping

Desorption electrospray ionization mass spectrometry imaging (DESI-MSI) provides direct analytical readouts of small molecules that can be used to characterize the metabolic phenotypes of genetically engineered bacteria. In an effort to accelerate the time frame associated with the screening of mutant libraries, we have developed a high-throughput DESI-MSI analytical workflow implementing a single raster line-scan strategy that facilitates the collection of location-resolved molecular information from engineered strains on a subminute time scale. Evaluation of this “Fast-Pass” DESI-MSI phenotyping workflow on analytical standards demonstrated the capability of acquiring full metabolic profiling information with a throughput of ~40 s per sample. This Fast-Pass strategy was implemented in the analysis of genetically edited Escherichia coli strains that have been engineered to produce various free-fatty acids (FFAs) for applications relevant to biofuels. Due to the untargeted nature of DESI-MSI, the investigation of these strains yielded molecular information for both global metabolites and targeted detection of accumulated bioproducts, allowing simultaneous readouts of strain-specific chemical profiles and comparative measurements of FFA production levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotherm Model for Moisture-Controlled CO 2 Sorption

Moisture-controlled sorption of CO 2 , the basis for moisture-swing CO 2 capture from air, is a novel phenomenon observed in strong-base anion exchange materials. Prior research has shown that Langmuir isotherms provide an approximate fit to moisture-controlled CO 2 sorption isotherm data. However, this fit still lacks a governing equation derived from an analytic model. As such, in this paper we derive an analytic form for an isotherm equation from a bottom-up approach, starting with a fundamental theory for an alkali liquid. In the range of interest relevant to CO 2 capture from air, an isotherm equation for an alkali liquid reduces to a simple analytic form with a single parameter, $K_{\text{eq}}$. In the limit $K_{\text{eq}} \gg 1$, a 2nd order approximation simplifies to a Langmuir isotherm that, however, deviates from experimental data. The isotherm theory for an alkali liquid has been generalized to a strong-base anion exchange material. In a strong-base anion exchange material, water concentration inside a sorbent, [H 2 O], is not large enough to be regarded as constant, which allows us to extend $K_{\text{eq}}$ to $K_{\text{eq(AEM)eff}} = K_{\text{eq(AEM)}} \times$ [H 2 O]$^{–n}$ according to the law of mass action. The final isotherm formula has been validated by experimental data from the literature. For a moisture-controlled CO 2 sorbent, $K_{\text{eq(AEM)eff}}$ varies significantly with moisture content of the sorbent. Depending on moisture level, the observed $K_{\text{eq(AEM)eff}}$ in a specific sorbent ranges from a few times to a few thousand times the value of $K_{\text{eq}}$ of a 2 mol L –1 alkali liquid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗