Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Assessment of the Effectiveness of Three Aftermarket Gasoline Fuel Stabilizers in Preventing Gum Formation and Loss of Oxidation Stability

We note that fuel stabilizers have long been marketed to consumers to prevent oxidation and gum formation. In the past, gasoline storage for long periods of time was commonly limited to off-road equipment that was used infrequently. Cars and trucks that were driven regularly consumed the fuel in their tanks rapidly enough to avoid excessive fuel aging. However, plug-in hybrid electric vehicles (PHEVs) may be operated frequently without engine operation, raising the possibility that fuel may be stored in the tank for longer periods of time. Studies of the oxidation of gasoline have provided scientific understanding of the process, but there is little if any scientifically backed information aimed at aiding consumers in assessing the need to use an aftermarket fuel stabilizer if they anticipate lengthy periods of fuel storage in their fuel tank. This study was conceived to address this information gap by evaluating three aftermarket stabilizer products alongside baseline gasoline using sealed samples over a period of 12 months of aging. The aging was carried out under ambient temperature conditions with an additional series of samples kept in refrigerated storage. Analyses of vapor pressure, copper strip corrosion, oxidation stability, existent gums, and potential gums were carried out using standard ASTM tests to evaluate the samples as aging progressed. The results show that baseline gasoline remained compliant with relevant specifications to at least 12 months of aging without the use of aftermarket stabilizer additives. Use of two of the aftermarket additives increased the oxidation stability of the baseline gasoline, but this added stability was not necessary to comply with gasoline specifications.

42 ENGINEERING↗

Assessing the National Off-Cycle Benefits of 2-Layer HVAC Technology Using Dynamometer Testing and a National Simulation Framework

Some CO2-reducing technologies have real-world benefits not captured by regulatory testing methods. This paper documents a two-layer heating, ventilation, and air-conditioning (HVAC) system that facilitates faster engine warmup through strategic increased air recirculation. The performance of this technology was assessed on a 2020 Hyundai Sonata. Empirical performance of the technology was obtained through dynamometer tests at Argonne National Laboratory. Performance of the vehicle across multiple cycles and cell ambient temperatures with the two-layer technology active and inactive indicated fuel consumption reduction in nearly all cases. A thermally sensitive powertrain model, the National Renewable Energy Laboratory's FASTSim Hot, was calibrated and validated against vehicle testing data. The developed model included the engine, cabin, and HVAC system controls. Validation of component thermal models and engine efficiency ensured accurate thermal dynamics, fuel consumption, and two-layer benefit. The real-world benefit of the two-layer technology was calculated by simulating the validated powertrain model across a representative test matrix comparing performance with and without the two-layer system. Simulation across the test matrix revealed a real-world representative benefit of 0.0835%. Analysis of test matrix results at the regional level revealed the most benefit in cold climates and rural regions. Mean results across cycle length sensitivity simulations revealed a larger real-world benefit of 0.0872%. These benefit values can be considered a more accurate assessment of real-world technology performance. Future work is planned to explore the requisite number of drive cycles to ensure the full technology benefit is captured.

2-layer↗

Reactions of NO 3 with aromatic aldehydes: gas-phase kinetics and insights into the mechanism of the reaction

Rate coefficients for the reaction of NO3 radicals with a series of aromatic aldehydes were measured in a 7300 L simulation chamber at ambient temperature and pressure by relative and absolute methods. The rate coefficients for benzaldehyde (BA), ortho-tolualdehyde (O-TA), meta-tolualdehyde (M-TA), para-tolualdehyde (P-TA), 2,4-dimethyl benzaldehyde (2,4-DMBA), 2,5-dimethyl benzaldehyde (2,5-DMBA) and 3,5-dimethyl benzaldehyde (3,5-DMBA) were k 1 = 2.6 ± 0.3, k 2 = 8.7 ± 0.8, k 3 = 4.9 ± 0.5, k 4 = 4.9 ± 0.4, k 5 = 15.1 ± 1.3, k 6 = 12.8 ± 1.2 and k 7 = 6.2 ± 0.6, respectively, in the units of 10 -15 cm 3 molec. -1 s -1 at 298 ± 2 K. The rate coefficient k 13 for the reaction of the NO 3 radical with deuterated benzaldehyde (benzaldehyde-d1) was found to be half that of k 1 . The end product of the reaction in an excess of NO 2 was measured to be C 6 H 5 C(O)O 2 NO 2 . Furthermore, theoretical calculations of aldehydic bond energies and reaction pathways indicate that the NO 3 radical reacts primarily with aromatic aldehydes through the abstraction of an aldehydic hydrogen atom. The atmospheric implications of the measured rate coefficients are briefly discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement report: Vertically resolved atmospheric properties observed over the Southern Great Plains with the ArcticShark uncrewed aerial system

Abstract. This study presents the unique capability of the Department of Energy (DOE) ArcticShark – a mid-size fixed-wing uncrewed aerial system (UAS) – for measuring vertically resolved atmospheric properties over the Southern Great Plains (SGP) of the United States. Focusing on atmospheric states, such as ambient temperature, wind, and aerosol properties, we overview measurements from 32 research flights (∼ 97 flight hours) in 2023. The August operations, aided by a visual observer on a chase plane, allowed for extensive UAS coverage, surpassing typical UAS operation envelopes. Our data from March, June, and August 2023 reveal distinctive seasonal patterns within the atmospheric column through unique chemical composition measurements. In situ measurements combined with remote sensing retrievals and radiosonde measurements provided valuable insights into their consistency and complementarity. Furthermore, we demonstrate the capabilities of the ArcticShark through several case studies, including the analyses of correlations between UAS-derived atmospheric profiles and conventional radiosonde measurements, as well as the derivation of vertically resolved profiles of aerosol chemical, optical, and microphysical properties. These case studies highlight the versatility of the ArcticShark UAS as a powerful tool for comprehensive atmospheric research, effectively bridging data gaps and enhancing our understanding of vertical atmospheric structures in the region.

54 ENVIRONMENTAL SCIENCES↗

Particle Flow Distribution in a Fluidized-Particles Multitube Solar Receiver

A fluidized-particles two-tube solar receiver was tested at ambient temperature at PROMES Laboratory to investigate the influence of an inhomogeneous solar flux density on the particle mass flow rate between the tubes. The principle of this 3rd generation solar receiver is to fluidize the particles in a container, called dispenser, in which the tubes’ bottom are immersed. The fluidized particles are flowing upward the tubes by applying an overpressure in the dispenser. Air velocities are changed inside the tubes, thanks to air mass flow controllers, to represent temperature heterogeneity between the tubes. Air velocities from 0.05 up to 0.52 m/s were tested, both in homogeneous and heterogeneous conditions. In the heterogeneous ones, the differences in air velocity between the tubes aim to mimic a difference in temperature from 20 to 100 % with homogeneous air flow rates injected. The following conclusions were drawn. First, the particle mass flux in the tubes are the same with homogeneous air velocities, each one following a calibration map previously obtained. Second, different air velocities lead to different particle mass flux. Third, the rise of the total particle mass flux diminishes the pressure in the dispenser. Four, this diminution of pressure leads to a decrease of the particle mass flow rate of the tube with the lower air velocity. This influence can lead in some cases to the stop of the fluidized bed circulation in the affected tube.

Sahuquet, Guillaume (ORCID:0000000302752890)↗

Rational Electrolyte Formulation for Sodium Metal Batteries Operating in Extremely Cold Environments

Sodium metal batteries have shown considerable potential when operated at ambient temperatures. However, their performance in cold environments is constrained by increased electrolyte resistance with decreasing temperature and dendritic sodium plating associated with unstable solid electrolyte interphase (SEI), which are primarily influenced by the electrolyte composition. In this study, we present an electrolyte formulation that remains thermally stable down to −150 °C, which not only facilitates low internal resistance but also contributes to the formation of a protective SEI under cryogenic conditions. When cycled at −40 °C at 1 mA cm −2 , the sodium metal electrode exhibits a low overpotential of only 16 mV over 750 h; even at an ultra-low temperature of −80 °C, the electrode demonstrates remarkable long-term stability with a low overpotential of 54 mV sustained over 1500 h at 0.5 mA cm −2 . Furthermore, full cell evaluations when paring with Na 3 V 2 (PO 4 ) 3 cathode reveal a high average Coulombic efficiency exceeding 99.1% and a capacity retention over 83% after 100 cycles at both −40 °C and −80 °C.

Electrolyte↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗

Solid-state recoverable fuse functions as circuit breaker

Molded, conductive-epoxy recoverable fuse protects electronic circuits during overload conditions, and then permits them to continue to function immediately after the overload condition is removed. It has low resistance at ambient temperature, and high resistance at an elevated temperature.

Thomas, E. F., Jr.↗

Stabilizing stainless steel components for cryogenic service

Warpage and creep in stainless steel valve components are decreased by a procedure in which components are machined to a semifinish and then cold soaked in a bath of cryogenic liquid. After the treatment they are returned to ambient temperature and machine finished to the final drawing dimensions.

Holden, C. F.↗

Self-lubricating gear

Self-lubricating gear, designed for long term operation in a vacuum at high, low, and ambient temperatures, is constructed of alternating layers of metal and a dry lubricant material, such as polytetrafluoroethylene, with a suitable reinforcing material bonded into a laminated composite unit, which is machined to form a standard gear.

Demorest, K. E.↗

Device for reflowing electrodeposited solder on terminals

Terminals are reflowed in a hot strata and solidified in a cooler strata, without physical contact with each other, any fixturing, or the container. Terminals are passed through the upper portion of a reflow flask containing hot peanut oil, and then through the lower portion containing oil at ambient temperatures.

Johnson, W. C.↗