Performance of a Silicon-Drift Detector in 200kV TEM Environments

Silicon-drift detectors for energy-dispersive spectroscopy have gained increasing acceptance in the field principally because of their outstanding capabilities for high count-rate performance coupled with excellent resolution [1,2]. Improvements in design in the last few years have overcome some early disadvantages of the SDD in comparison to Si(Li) detectors, which have dominated the field for nearly 4 decades. Amongst these are detection efficiency in the low-energy regime, and a dropoff in detection efficiency at higher energies above 10keV. The former disadvantage has been largely overcome by generational design improvements to minimize the effective dead layer at the entrance window, so that present detectors provide better performance in the low-energy regime than Si(Li) detectors. In the latter case, higher energy peak detection performance has been improved by increasing the thickness of the detector. This is important primarily for the use of the SDD in a TEM environment, where very high count rates are not encountered due to the thin sample geometry. Also of importance for incorporation of an SDD into a TEM column is the lack of need for liquid nitrogen, since the SDD is chilled by a thermoelectric cooler. This is an advantage for SEM and microprobe operation also, but high-resolution TEMs (particularly aberration-corrected instruments) are more sensitive to vibration than SEMs or microprobes, so the much reduced form factor of an air-cooled SDD relative to a Si(Li) detector with a large LN2 dewar is desirable for use on the TEM. We have recently tested two Bruker C

200kV TEM↗

Production of the charmonium states {chi}{sub c1} and {chi}{sub c2} in proton nucleus interactions at {radical}(s)=41.6 GeV

A measurement of the ratio R{sub {chi}{sub c}}=({chi}{sub c}{yields}J/{psi}+{gamma})/J/{psi} in pC, pTi, and pW interactions at 920 GeV/c ({radical}(s)=41.6 GeV) in the Feynman-x range -0.35<x{sub F}{sup J/{psi}}<0.15 is presented. Both {mu}{sup +}{mu}{sup -} and e{sup +}e{sup -} J/{psi} decay channels are observed with an overall statistics of about 15 000 {chi}{sub c} events, which is by far the largest available sample in pA collisions. The result is R{sub {chi}{sub c}}=0.188{+-}0.013{sub st}(+0.024/-0.022){sub sys} averaged over the different materials, when no J/{psi} and {chi}{sub c} polarizations are considered. The {chi}{sub c1} to {chi}{sub c2} production ratio R{sub 12}=R{sub {chi}{sub c}}{sub 1}/R{sub {chi}{sub c}}{sub 2} is measured to be 1.02{+-}0.40, leading to a cross section ratio ({sigma}({chi}{sub c1})/{sigma}({chi}{sub c2}))=0.57{+-}0.23. The dependence of R{sub {chi}{sub c}} on the Feynman-x of the J/{psi}, x{sub F}{sup J/{psi}}, and its transverse momentum, p{sub T}{sup J/{psi}}, is studied, as well as its dependence on the atomic number, A, of the target. For the first time, an extensive study of possible biases on R{sub {chi}{sub c}} and R{sub 12} due to the dependence of acceptance on the polarization states of J/{psi} and {chi}{sub c} is performed. By varying the polarization parameter, {lambda}{sub obs}, of all produced J/{psi}'s by two sigma around the value measured by HERA-B, and considering the maximum variation due to the possible {chi}{sub c1} and {chi}{sub c2} polarizations, it is shown that R{sub {chi}{sub c}} could change by a factor between 1.02 and 1.21 and R{sub 12} by a factor between 0.89 and 1.16.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of CP Asymmetries and Branching Fractions of Two-Body Charmless Decays of $B^0$ and $B^0_s$ Mesons

The thesis is organized as follows: Chapter 1 describes the theoretical framework of non-leptonic B$$0\atop{s}$$ → H +h' - decays, with a simple overview of the CP violation mechanism within the Standard Model and of the most used phenomenological approaches in the evaluation of strong interaction contributions. The chapter contains also a review of the theoretical expectations and the current experimental measurements along with a discussion about the importance of studying such decays. Chapter 2 contains a general description of the Tevatron collider and of the CDF II detector. Chapter 3 is devoted to the description of the data sample used for the measurement and the method used in extracting the signal from the background. Particular attention is dedicated to the on-line trigger selection, which is crucial to collect a sample enriched in B$$0\atop{s}$$ → h +h' - decays. Chapter 4 shows how the information from kinematics and particle identification was used to achieve a statistical discrimination amongst modes to extract individual measurements. The available resolutions in mass or in particle identification are separately insufficient for an event-by-event separation of B$$0\atop{s}$$ → h +h' - modes. The choice of observables and the technique used to combine them is an important and innovative aspect of the analysis described in this thesis. Chapter 5 is devoted to the accurate determination of the invariant mass lineshape. This is a crucial ingredient for resolving overlapping mass peaks. This chapter details all resolution effects with particular attention at the tails due to the emission of low-energy photons from charged kaons and pions in the final state (FSR). For the first time the effect of FSR has been accurately accounted for in a CDF analysis. Chapter 6 describes how kinematic and PID information, discussed in chap. 4 and chap. 5 were combined in a maximum Likelihood fit to statistically determine the composition of the B$$0\atop{s}$$ → h +h' - sample. This kinematics-PID combined fit has been developed and performed for the first time at CDF in the analysis presented in this thesis and this methodology was later inherited by several other analyses. Chapter 7 is devoted to the study of the isolation variable, which is a crucial handle to enhance the signal-to-background ratio in the off-line selection. It exploits the property that the b-hadrons tend to carry a larger fraction of the transverse momentum of the particles produced in the fragmentation, with respect to lighter hadrons. Since the simulators do not accurately reproduce the fragmentation processes, this chapter is devoted to the study of the control data sample of B$$0\atop{s}$$ → J/ΨX decays to probe the characteristics of this variable. Chapter 8 describes an innovative procedure used to optimize the selection to minimize the statistical uncertainty on the quantities one wishes to measure. The procedure is based on the fit of composition described in chap. 6. Chapter 9 reports the results of the fit of composition described in chap. 6 and the cross-checks performed to verify the goodness of the fit of composition. In order to translate the parameters returned from the fit into physics measurements the relative efficiency corrections between the various decay modes need to be applied. Chapter 10 is devoted to the description of these corrections. Chapter 11 describes the measurement of the detector-induced charge asymmetry between positively and negatively charged kaons and pions, due to their different probability of strong interaction in the tracker material using the real data. This allows to extract the acceptance correction factor for the CP asymmetries measurement without any external inputs from the simulation, and to perform a powerful check of whole analysis. Chapter 12 describes the main sources of systematic uncertainties and the method used to evaluate the significance of the results on rare modes. The final results of the measurements and their interpretation are discussed in chap. 13.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the cosmic distance duality relation using time delay lenses

The construction of the cosmic distance-duality relation (CDDR) has been widely studied. However, its consistency with various new observables remains a topic of interest. We present a new way to constrain the CDDR η( z ) using different dynamic and geometric properties of strong gravitational lenses (SGL) along with SNe Ia observations. We use a sample of 102 SGL with the measurement of corresponding velocity dispersion σ{sub 0} and Einstein radius θ {sub E} . In addition, we also use a dataset of 12 two image lensing systems containing the measure of time delay Δ t between source images. Jointly these two datasets give us the angular diameter distance D {sub A} {sub ol} of the lens. Further, for luminosity distance, we use the 740 observations from JLA compilation of SNe Ia. To study the combined behavior of these datasets we use a model independent method, Gaussian Process (GP). We also check the efficiency of GP by applying it on simulated datasets, which are generated in a phenomenological way by using realistic cosmological error bars. Finally, we conclude that the combined bounds from the SGL and SNe Ia observation do not favor any deviation of CDDR and are in concordance with the standard value (η=1) within 2σ confidence region, which further strengthens the theoretical acceptance of CDDR.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-157: Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation

Purpose: To develop an imaging technique that enables us to acquire T2- weighted 4D Magnetic Resonance Imaging (4DMRI) with sufficient spatial coverage, temporal resolution and spatial resolution for clinical evaluation. Methods: T2-weighed 4DMRI images were acquired from a healthy volunteer using a respiratory amplitude triggered T2-weighted Turbo Spin Echo sequence. 10 respiratory states were used to equally sample the respiratory range based on amplitude (0%, 20%i, 40%i, 60%i, 80%i, 100%, 80%e, 60%e, 40%e and 20%e). To avoid frequent scanning halts, a methodology was devised that split 10 respiratory states into two packages in an interleaved manner and packages were acquired separately. Sixty 3mm sagittal slices at 1.5mm in-plane spatial resolution were acquired to offer good spatial coverage and reasonable spatial resolution. The in-plane field of view was 375mm × 260mm with nominal scan time of 3 minutes 42 seconds. Acquired 2D images at the same respiratory state were combined to form the 3D image set corresponding to that respiratory state and reconstructed in the coronal view to evaluate whether all slices were at the same respiratory state. 3D image sets of 10 respiratory states represented a complete 4D MRI image set. Results: T2-weighted 4DMRI image were acquired in 10 minutes which was within clinical acceptable range. Qualitatively, the acquired MRI images had good image quality for delineation purposes. There were no abrupt position changes in reconstructed coronal images which confirmed that all sagittal slices were in the same respiratory state. Conclusion: We demonstrated it was feasible to acquire T2-weighted 4DMRI image set within a practical amount of time (10 minutes) that had good temporal resolution (10 respiratory states), spatial resolution (1.5mm × 1.5mm × 3.0mm) and spatial coverage (60 slices) for future clinical evaluation.

60 APPLIED LIFE SCIENCES↗

Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications.

60 APPLIED LIFE SCIENCES↗

Method for Implementing Subsurface Solid Derived Concentration Guideline Levels (DCGL) - 12331

The U.S. Nuclear Regulatory Commission (NRC) and other federal agencies currently approve the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) as guidance for licensees who are conducting final radiological status surveys in support of decommissioning. MARSSIM provides a method to demonstrate compliance with the applicable regulation by comparing residual radioactivity in surface soils with derived concentration guideline levels (DCGLs), but specifically discounts its applicability to subsurface soils. Many sites and facilities undergoing decommissioning contain subsurface soils that are potentially impacted by radiological constituents. In the absence of specific guidance designed to address the derivation of subsurface soil DCGLs and compliance demonstration, decommissioning facilities have attempted to apply DCGLs and final status survey techniques designed specifically for surface soils to subsurface soils. The decision to apply surface soil limits and surface soil compliance metrics to subsurface soils typically results in significant over-excavation with associated cost escalation. MACTEC, Inc. has developed the overarching concepts and principles found in recent NRC decommissioning guidance in NUREG 1757 to establish a functional method to derive dose-based subsurface soil DCGLs. The subsurface soil method developed by MACTEC also establishes a rigorous set of criterion-based data evaluation metrics (with analogs to the MARSSIM methodology) that can be used to demonstrate compliance with the developed subsurface soil DCGLs. The method establishes a continuum of volume factors that relate the size and depth of a volume of subsurface soil having elevated concentrations of residual radioactivity with its ability to produce dose. The method integrates the subsurface soil sampling regime with the derivation of the subsurface soil DCGL such that a self-regulating optimization is naturally sought by both the responsible party and regulator. This paper describes the concepts and basis used by MACTEC to develop the dose-based subsurface soil DCGL method. The paper will show how MACTEC's method can be used to demonstrate that higher concentrations of residual radioactivity in subsurface soils (as compared with surface soils) can meet the NRC's dose-based regulations. MACTEC's method has been used successfully to obtain the NRC's radiological release at a site with known radiological impacts to subsurface soils exceeding the surface soil DCGL, saving both time and cost. Having considered the current NRC guidance for consideration of residual radioactivity in subsurface soils during decommissioning, MACTEC has developed a technically based approach to the derivation of and demonstration of compliance with subsurface soil DCGLs for radionuclides. In fact, the process uses the already accepted concepts and metrics approved for surface soils as the foundation for deriving scaling factors used to calculate subsurface soil DCGLs that are at least equally protective of the decommissioning annual dose standard. Each of the elements identified for consideration in the current NRC guidance is addressed in this proposed method. Additionally, there is considerable conservatism built into the assumptions and techniques used to arrive at subsurface soil scaling factors and DCGLs. The degree of conservatism embodied in the approach used is such that risk managers and decision makers approving and using subsurface soil DCGLs derived in accordance with this method can be confident that the future exposures will be well below permissible and safe levels. The technical basis for the method can be applied to a broad variety of sites with residual radioactivity in subsurface soils. Given the costly nature of soil surveys, excavation, and disposal of soils as low-level radioactive waste, MACTEC's method for deriving and demonstrating compliance with subsurface soil DCGLs offers the possibility of significant cost savings over the traditional approach of applying surface soil DCGLs to subsurface soils. Furthermore, while yet untested, MACTEC believes that the concepts and methods embodied in this approach could readily be applied to other types of contamination found in subsurface soils. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transport of triplet excitons along continuous 100 nm polyfluorene chains

Triplet excitons created in poly-2,7-(9,9-dihexyl)fluorene (pF) chains with end trap groups in solution are efficiently transported to and captured by the end groups. The triplets explore the entire lengths of the chains, even for ~100 nm long chains enabling determination of the completeness of end capping. The results show that the chains continuous: they may contain transient barriers or traps, such as those from fluctuations of dihedral angles, but are free of major defects that stop motion of the triplets. Quantitative determinations are aided by the addition of a strong electron donor, TMPD, which removes absorption bands of the end-trapped triplets. For chains having at least one end trap, triplet capture is quantitative on the 1 µs timescale imposed by the use of the donor. Fractions of chains having no end traps were 0.15 for pF samples with anthraquinone (AQ) end traps and 0.063 with naphthylimide (NI) end traps. These determinations agreed with measurements by NMR for short (<40 polymer repeat units (PRU)) chains, where NMR determinations are accurate. The results find no evidence for traps or barriers to transport of triplets, and places limits on the possible presence of defects as impenetrable barriers to less than one per 300 PRU. The present results present a paradigm different from the current consensus, derived from observations of singlet excitons, that conjugated chains are divided into “segments,” perhaps by some kind of defects. For the present pF chains, the segmentation either does not apply to triplet excitons or is transient so that the defects are healed or surmounted in times much shorter than 1 µs. Triplets on chains without end trap groups transfer to chains with end traps on a slower time scale. Rate constants for these bimolecular triplet transfer reactions were found to increase with the length of the accepting chain, as did rate constants for triplet transfer to the chains from small molecules like biphenyl. As a result, a second set of polyfluorenes with 2-butyloctyl side chains was found to have a much lower completeness of end capping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-12: A New Stereological Method for Tumor Volume Evaluation for Esophageal Cancer

Purpose: Stereological method used to obtain three dimensional quantitative information from two dimensional images is a widely used tool in the study of cells and pathology. But the feasibility of the method for quantitative evaluation of volumes with 3D image data sets for radiotherapy clinical application has not been explored. On the other hand, a quick, easy-to-use and reliable method is highly desired in image-guided-radiotherapy(IGRT) for tumor volume measurement for the assessment of response to treatment. To meet this need, a stereological method for evaluating tumor volumes for esophageal cancer is presented in this abstract. Methods: The stereology method was optimized by selecting the appropriate grid point distances and sample types. 7 patients with esophageal cancer were selected retrospectively for this study, each having pre and post treatment computed tomography (CT) scans. Stereological measurements were performed for evaluating the gross tumor volume (GTV) changes after radiotherapy and the results was compared with the ones by planimetric measurements. Two independent observers evaluated the reproducibility for volume measurement using the new stereological technique. Results: The intraobserver variation in the GTV volume estimation was 3.42±1.68cm3 (the Wilcoxon matched-pairs test Resultwas Z=−1.726,P=0.084>0.05); the interobserver variation in the GTV volume estimation was 22.40±7.23 cm3 (Z=−3.296,P=0.083>0.05), which showed the consistency in GTV volume calculation with the new method for the same and different users. The agreement level between the results from the two techniques was also evaluated. Difference between the measured GTVs was 20.10±5.35 cm3 (Z=−3.101,P=0.089>0.05). Variation of the measurement results using the two techniques was low and clinically acceptable. Conclusion: The good agreement between stereological and planimetric techniques proves the reliability of the stereological tumor volume estimations. The optimized stereological technique described in this abstract may provide a quick, unbiased and reproducible tool for tumor volume estimation for treatment response assessment. Supported by NSFC (#81041107, #81171342 and #31000784)

60 APPLIED LIFE SCIENCES↗

Electronic Structure of the Mn[subscript 4]Ca Cluster in the Oxygen-Evolving Complex of Photosystem II Studied by Resonant Inelastic X-Ray Scattering

Oxygen-evolving complex (Mn{sub 4}Ca cluster) of Photosystem II cycles through five intermediate states (S{sub i}-states, i = 0-4) before a molecule of dioxygen is released. During the S-state transitions, electrons are extracted from the OEC, either from Mn or alternatively from a Mn ligand. The oxidation state of Mn is widely accepted as Mn{sub 4}(III{sub 2},IV{sub 2}) and Mn{sub 4}(III,IV{sub 3}) for S{sub 1} and S{sub 2} states, while it is still controversial for the S{sub 0} and S{sub 3} states. We used resonant inelastic X-ray scattering (RIXS) to study the electronic structure of Mn{sub 4}Ca complex in the OEC. The RIXS data yield two-dimensional plots that provide a significant advantage by obtaining both K-edge pre-edge and L-edge-like spectra simultaneously. The second energy dimension separates the pre-edge (1s to 3d) transitions from the main K-edge (1s to 4p), and thus more precise analysis is possible. The 1s2p RIXS final state electron configuration along the energy transfer axis is identical to conventional L-edge absorption spectroscopy and the RIXS spectra are therefore sensitive to the metal spin state. We have collected data from PS II samples in the each of the S-states and compared them with data from various inorganic Mn complexes. The spectral changes in the Mn 1s2p{sub 3/2} RIXS spectra between the S-states are small compared to those of the oxides of Mn and coordination complexes. The results indicate strong covalency for the electronic configuration in the OEC, and we conclude that the electron is transferred from a strongly delocalized orbital, compared to those in Mn oxides or coordination complexes. The magnitude for the S{sub 0} to S{sub 1}, and S{sub 1} to S{sub 2} transitions is twice as large as that during the S{sub 2} to S{sub 3} transition, indicating that the electron for this transition is extracted from a highly delocalized orbital with little change in charge density at the Mn atoms. The RIXS spectra of S{sub 0} and S{sub 3} states also showed characteristic features which were not clear from the K-edge spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-line phase shift tomosynthesis

Purpose: The purpose of this work is to (1) demonstrate laboratory measurements of phase shift images derived from in-line phase-contrast radiographs using the attenuation-partition based algorithm (APBA) of Yan et al.[Opt. Express 18(15), 16074–16089 (2010)], (2) verify that the APBA reconstructed images obey the linearity principle, and (3) reconstruct tomosynthesis phase shift images from a collection of angularly sampled planar phase shift images.Methods: An unmodified, commercially available cabinet x-ray system (Faxitron LX-60) was used in this experiment. This system contains a tungsten anode x-ray tube with a nominal focal spot size of 10 μm. The digital detector uses CsI/CMOS with a pixel size of 50 × 50 μm. The phantoms used consisted of one acrylic plate, two polystyrene plates, and a habanero pepper. Tomosynthesis images were reconstructed from 51 images acquired over a ±25° arc. All phase shift images were reconstructed using the APBA.Results: Image contrast derived from the planar phase shift image of an acrylic plate of uniform thickness exceeded the contrast of the traditional attenuation image by an approximate factor of two. Comparison of the planar phase shift images from a single, uniform thickness polystyrene plate with two polystyrene plates demonstrated an approximate linearity of the estimated phase shift with plate thickness (−1600 rad vs −2970 rad). Tomographic phase shift images of the habanero pepper exhibited acceptable spatial resolution and contrast comparable to the corresponding attenuation image.Conclusions: This work demonstrated the feasibility of laboratory-based phase shift tomosynthesis and suggests that phase shift imaging could potentially provide a new imaging biomarker. Further investigation will be needed to determine if phase shift contrast will be able to provide new tissue contrast information or improved clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From lapis lazuli to ultramarine blue: investigating Cennino Cennini’s recipe using sulfur K-edge XANES

As one of the most desired and expensive artists’ materials throughout history, there has long been interest in studying natural lapis lazuli. The traditional method of extracting the blue component, lazurite, from lapis lazuli, as outlined in Cennini’s Il Libro dell’Arte , involves a lengthy purification process: (1) finely grind the rock; (2) mix with pine rosin, gum mastic, and beeswax; (3) massage in water to collect the lazurite. Repeating the process produces several grades of the pigment, typically referred to as ultramarine blue. Here, we investigate the sulfur environment within the aluminosilicate framework of lazurite during its extraction from lapis lazuli. The sulfur XANES fingerprint from samples taken at the different stages in Cennini’s extraction method were examined. All spectra contain a strong absorption peak at 2483 eV, attributable to sulfate present in the lazurite structure. However, intensity variations appear in the broad envelope of peaks between 2470 and 2475 eV and the pre-peak at 2469.1 eV, indicating a variation in the content of trisulfur (S 3 –˙ ) radicals. By studying the effect of each step of Cennini’s process, this study elucidates the changes occurring during the extraction and the variability within different grades of the precious coloring material. The increasing application of XANES to the study of artist’s materials and works of art motivated extending the research to assess the possibility of X-ray induced damage. Direct comparison of micro-focused and unfocused beam experiments suggests an increase of the S 3 –˙ radicals with prolonged exposure. Furthermore, analysis indicates that induced damage follows first-order kinetics, providing a first assessment on the acceptable amount of radiation exposure to define the optimal acquisition parameters to allow safe analyses of lapis lazuli and ultramarine pigments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The phase space of z∼1.2 SpARCS clusters: Using Herschel to probe dust temperature as a function of environment and accretion history

We present a five-band Herschel study (100–500 μm) of three galaxy clusters at z∼1.2 from the Spitzer Adaptation of the Red-Sequence Cluster Survey. With a sample of 120 spectroscopically confirmed cluster members, we investigate the role of environment on galaxy properties utilizing the projected cluster phase space (line-of-sight velocity versus clustercentric radius), which probes the time-averaged galaxy density to which a galaxy has been exposed. We divide cluster galaxies into phase-space bins of (r/r{sub 200})×(Δv/σ{sub v}), tracing a sequence of accretion histories in phase space. Stacking optically star-forming cluster members on the Herschel maps, we measure average infrared star formation rates, and, for the first time in high-redshift galaxy clusters, dust temperatures for dynamically distinct galaxy populations—namely, recent infalls and those that were accreted onto the cluster at an earlier epoch. Proceeding from the infalling to virialized (central) regions of phase space, we find a steady decrease in the specific star formation rate and increase in the stellar age of star-forming cluster galaxies. We perform a probability analysis to investigate all acceptable infrared spectral energy distributions within the full parameter space and measure a ∼4σ drop in the average dust temperature of cluster galaxies in an intermediate phase-space bin, compared to an otherwise flat trend with phase space. We suggest one plausible quenching mechanism which may be consistent with these trends, invoking ram-pressure stripping of the warmer dust for galaxies within this intermediate accretion phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Qualification of a Radioactive High Aluminum Glass for Processing in the Defense Waste Processing Facility at the Savannah River Site

At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a borosilicate glass for approximately eleven years. Currently the DWPF is immobilizing HLW sludge in Sludge Batch 4 (SB4). Each sludge batch is nominally two million liters of HLW and produces nominally five hundred stainless steel canisters 0.6 meters in diameter and 3 meters tall filled with the borosilicate glass. In SB4 and earlier sludge batches, the Al concentration has always been rather low, (less than 9.5 weight percent based on total dried solids). It is expected that in the future the Al concentrations will increase due to the changing composition of the HLW. Higher Al concentrations could introduce problems because of its known effect on the viscosity of glass melts and increase the possibility of the precipitation of nepheline in the final glass and decrease its durability. In 2006 Savannah River National Laboratory (SRNL) used DWPF processes to immobilize a radioactive HLW slurry containing 14 weight percent Al to ensure that this waste is viable for future DWPF processing. This paper presents results of the characterization of the high Al glass prepared in that demonstration. At SRNL, a sample of the processed high Al HLW slurry was mixed with an appropriate glass frit as performed in the DWPF to make a waste glass containing nominally 30% waste oxides. The glass was prepared by melting the frit and waste remotely at 1150 deg. C. The glass was then characterized by - determining the chemical composition of the glass including the concentrations of several actinide and U-235 fission products, - calculating the oxide waste loading of the glass based on the chemical composition and comparing it to that of the target - determining if the glass composition met the DWPF processing constraints such as glass melt viscosity and liquidus temperature along with a waste form affecting constraint that prevents the precipitation of nepheline (NaAlSiO{sub 4}) crystals in the glass melt - measuring the durability of the glass using the ASTM Standard Product Consistency Test (PCT) leach test to determine if the durability of the glass based on B, Li, and Na releases met the requirements for acceptance in a US geologic repository - measuring the leachability of several radionuclides using the ASTM Standard PCT leach test and comparing them to the B, Li, and Na releases - examining the glass by scanning electron microscopy and energy dispersive X-ray spectrometry to determine if any crystals had formed in the glass melt. Results indicate that the high Al glass met all the requirements for processing and product quality in the DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Sustainability in Treatment of Contaminated Metals for Clearance and Recycling - 20290

Cyclife Sweden AB has, for more than 30 years, provided metal treatment services to the domestic and international nuclear industry with the aim of creating value through metal clearance and recycling. These operations are to a large extent based on the concept that the materials, after pre-treatment, including decontamination, will be melted for clearance. During the melting process, some nuclides separate from the metal while the remaining radioactivity becomes fully homogenized in the metal bath and the resulting ingots, along with the samples taken before casting At a time when activities to fight Climate Challenge are in focus, any savings in energy consumption, in addition to the positive environmental effect of recycling metals back to industry, is more than welcome. If the clearance of certain metallic items can be achieved safely, without using melting, it is the environmentally preferred option provided it carries a reasonable cost. It is even better if an object can go through a decontamination and clearance process prior to re-use inside or outside the nuclear sector. Cyclife Sweden is currently investing in a direct clearance process, to be operated in parallel with the melting process. This new process is expected to be fully operational in the late summer of 2020 and includes pre-treatment, decontamination and heavily shielded clearance measurement installations. The treatment will also allow clearance measurements of larger objects without the need for segmentation, along with allowing objects composed of different materials, like electric motors can be accepted for treatment. This paper gives an overview of the circular economy aspects in a nuclear back-end context, the Cyclife approach to further implement a circular economy approach in the processes, Material Acceptance Criteria for treatment, the facility set-up for the new process and how the melting route and the direct route can be combined in an efficient industrial scale process. To put the new capabilities into perspective, the two different treatment and clearance approaches, i.e. direct clearance and melting, are to be compared. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronic Structure of the Mn(4)Ca Cluster in the Oxygen-Evolving Complex of Photosystem Ii Studied By Resonant Inelastic X-Ray Scattering

Oxygen-evolving complex (Mn{sub 4}Ca cluster) of Photosystem II cycles through five intermediate states (S{sub i}-states, i=0--4) before a molecule of dioxygen is released. During the S-state transitions, electrons are extracted from the OEC, either from Mn or alternatively from a Mn ligand. The oxidation state of Mn is widely accepted as Mn{sub 4}(III{sub 2},IV{sub 2}) and Mn{sub 4}(III,IV{sub 3}) for S{sub 1} and S{sub 2} states, while it is still controversial for the S{sub 0} and S{sub 3} states. We used resonant inelastic X-ray scattering (RIXS) to study the electronic structure of Mn{sub 4}Ca complex in the OEC. The RIXS data yield two-dimensional plots that provide a significant advantage by obtaining both K-edge pre-edge and L-edge-like spectra simultaneously. The second energy dimension separates the pre-edge (1s to 3d) transitions from the main K-edge (1s to 4p), and thus more precise analysis is possible. The 1s2p RIXS final state electron configuration along the energy transfer axis is identical to conventional L-edge absorption spectroscopy and the RIXS spectra are therefore sensitive to the metal spin state. We have collected data from PS II samples in the each of the S-states and compared them with data from various inorganic Mn complexes. The spectral changes in the Mn 1s2p{sub 3/2} RIXS spectra between the S-states are small compared to those of the oxides of Mn and coordination complexes. The results indicate strong covalency for the electronic configuration in the OEC, and we conclude that the electron is transferred from a strongly delocalized orbital, compared to those in Mn oxides or coordination complexes. The magnitude for the S{sub 0} to S{sub 1}, and S{sub 1} to S{sub 2} transitions is twice as large as that during the S{sub 2} to S{sub 3} transition, indicating that the electron for this transition is extracted from a highly delocalized orbital with little change in charge density at the Mn atoms. The RIXS spectra of S{sub 0} and S{sub 3} states also showed characteristic features which were not clear from the K-edge spectroscopy.

36 MATERIALS SCIENCE↗

QUALIFICATION OF A RADIOACTIVE HIGH ALUMINUM GLASS FOR PROCESSINGIN THE DEFENSE WASTE PROCESSING FACILITY AT THE SAVANNAH RIVER SITE

At the Savannah River Site (SRS) the Defense Waste Processing Facility (DWPF) has been immobilizing SRS's radioactive high level waste (HLW) sludge into a borosilicate glass for approximately eleven years. Currently the DWPF is immobilizing HLW sludge in Sludge Batch 4 (SB4). Each sludge batch is nominally two million liters of HLW and produces nominally five hundred stainless steel canisters 0.6 meters in diameter and 3 meters tall filled with the borosilicate glass. In SB4 and earlier sludge batches, the Al concentration has always been rather low, (less than 9.5 weight percent based on total dried solids). It is expected that in the future the Al concentrations will increase due to the changing composition of the HLW. Higher Al concentrations could introduce problems because of its known effect on the viscosity of glass melts and increase the possibility of the precipitation of nepheline in the final glass and decrease its durability. In 2006 Savannah River National Laboratory (SRNL) used DWPF processes to immobilize a radioactive HLW slurry containing 14 weight percent Al to ensure that this waste is viable for future DWPF processing. This paper presents results of the characterization of the high Al glass prepared in that demonstration. At SRNL, a sample of the processed high Al HLW slurry was mixed with an appropriate glass frit as performed in the DWPF to make a waste glass containing nominally 30% waste oxides. The glass was prepared by melting the frit and waste remotely at 1150 C. The glass was then characterized by: (1) determining the chemical composition of the glass including the concentrations of several actinide and U-235 fission products; (2) calculating the oxide waste loading of the glass based on the chemical composition and comparing it to that of the target; (3) determining if the glass composition met the DWPF processing constraints such as glass melt viscosity and liquidus temperature along with a waste form affecting constraint that prevents the precipitation of nepheline (NaAlSiO{sub 4}) crystals in the glass melt; (4) measuring the durability of the glass using the ASTM Standard Product Consistency Test (PCT) leach test to determine if the durability of the glass based on B, Li, and Na releases met the requirements for acceptance in a US geologic repository; (5) measuring the leachability of several radionuclides using the ASTM Standard PCT leach test and comparing them to the B, Li, and Na releases; and (6) examining the glass by scanning electron microscopy and energy dispersive X-ray spectrometry to determine if any crystals had formed in the glass melt. Results indicate that the high Al glass met all the requirements for processing and product quality in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗