Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The use of bioelectric currents to study gravity perception in roots

Inhibitor-based studies of gravity perception in plants have yielded ambiguous results because gravitropism consists of many steps in series. Inhibiting any step eliminates gravicurvature; it cannot be shown whether gravity perception and transduction are affected by the inhibitory treatment. The use of the vibrating probe has allowed detection of a response that is measurable independent of stimulus transmission and growth, two post-transduction steps of gravitropism. This application of the vibrating probe requires particular attention to artifacts. Calmodulin action and auxin transport are both believed to be components of gravitropism and specific roles have been proposed for them in graviperception. The perception-dependent current measured with the vibrating probe is eliminated by inhibitors of calmodulin, but not by auxin inhibitors. Thus, the vibrating probe has made it possible to offer more direct evidence for a role of calmodulin in transduction, and to reject one for auxin transport in perception and transduction.

Non-NASA Center↗

Photothermally excited force modulation microscopy for broadband nanomechanical property measurements

We demonstrate photothermally excited force modulation microscopy (PTE FMM) for mechanical property characterization across a broad frequency range with an atomic force microscope (AFM). Photothermal excitation allows for an AFM cantilever driving force that varies smoothly as a function of drive frequency, thus avoiding the problem of spurious resonant vibrations that hinder piezoelectric excitation schemes. A complication of PTE FMM is that the sub-resonance cantilever vibration shape is fundamentally different compared to piezoelectric excitation. By directly measuring the vibrational shape of the cantilever, we show that PTE FMM is an accurate nanomechanical characterization method. PTE FMM is a pathway towards the characterization of frequency sensitive specimens such as polymers and biomaterials with frequency range limited only by the resonance frequency of the cantilever and the low frequency limit of the AFM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive Inverse Control for Rotorcraft Vibration Reduction

This thesis extends the Least Mean Square (LMS) algorithm to solve the mult!ple-input, multiple-output problem of alleviating N/Rev (revolutions per minute by number of blades) helicopter fuselage vibration by means of adaptive inverse control. A frequency domain locally linear model is used to represent the transfer matrix relating the higher harmonic pitch control inputs to the harmonic vibration outputs to be controlled. By using the inverse matrix as the controller gain matrix, an adaptive inverse regulator is formed to alleviate the N/Rev vibration. The stability and rate of convergence properties of the extended LMS algorithm are discussed. It is shown that the stability ranges for the elements of the stability gain matrix are directly related to the eigenvalues of the vibration signal information matrix for the learning phase, but not for the control phase. The overall conclusion is that the LMS adaptive inverse control method can form a robust vibration control system, but will require some tuning of the input sensor gains, the stability gain matrix, and the amount of control relaxation to be used. The learning curve of the controller during the learning phase is shown to be quantitatively close to that predicted by averaging the learning curves of the normal modes. For higher order transfer matrices, a rough estimate of the inverse is needed to start the algorithm efficiently. The simulation results indicate that the factor which most influences LMS adaptive inverse control is the product of the control relaxation and the the stability gain matrix. A small stability gain matrix makes the controller less sensitive to relaxation selection, and permits faster and more stable vibration reduction, than by choosing the stability gain matrix large and the control relaxation term small. It is shown that the best selections of the stability gain matrix elements and the amount of control relaxation is basically a compromise between slow, stable convergence and fast convergence with increased possibility of unstable identification. In the simulation studies, the LMS adaptive inverse control algorithm is shown to be capable of adapting the inverse (controller) matrix to track changes in the flight conditions. The algorithm converges quickly for moderate disturbances, while taking longer for larger disturbances. Perfect knowledge of the inverse matrix is not required for good control of the N/Rev vibration. However it is shown that measurement noise will prevent the LMS adaptive inverse control technique from controlling the vibration, unless the signal averaging method presented is incorporated into the algorithm.

Jacklin, Stephen A.↗

Methane spectral line widths and shifts, and dependences on physical parameters

A detailed report of the recent high-resolution spectroscopic research on widths and shifts measured for a strong infrared-active fundamental of methane is presented. They were measured in collision with several rare gases and diatomic molecules, in the vibrational-rotational fundamental near 3000/cm. These measurements were made at an ambient temperature of 294 K over a range of pressures from 100 to 700 torr. The measurements are discussed in a preliminary but detailed and quantitative manner with reference to masses, polarizabilities, and quadrupole moments. Some functional dependences on these physical parameters are considered. The present data are useful for studies of corresponding planetary spectra.

Fox, K.↗

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

Vibration mitigation in J-TEXT far-infrared diagnostic systems

Optical structure stability is an important issue for far-infrared (FIR) phase measurements. To ensure good signal quality, influence of vibration should be minimized. Mechanical amelioration and optical optimization can be taken in turn to decrease vibration's influence and ensure acceptable measurement. J-TEXT (Joint Texal Experiment Tokamak, formerly TEXT-U) has two FIR diagnostic systems: a HCN interferometer system for electron density measurement and a three-wave polarimeter-interferometer system (POLARIS) for electron density and Faraday effect measurements. All use phase detection techniques. HCN interferometer system has almost eliminated the influence of vibration after mechanical amelioration and optical optimization. POLARIS also obtained first experimental results after mechanical stability improvements and is expected to further reduce vibration's influence on Faraday angle to 0.1 Degree-Sign after optical optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements in Dual-Pump Broadband CARS for Supersonic Combustion Measurements

Space- and time-resolved measurements of temperature and species mole fractions of nitrogen, oxygen, and hydrogen were obtained with a dual-pump coherent anti-Stokes Raman spectroscopy (CARS) system in hydrogen-fueled supersonic combustion free jet flows. These measurements were taken to provide time-resolved fluid properties of turbulent supersonic combustion for use in the creation and verification of computational fluid dynamic (CFD) models. CFD models of turbulent supersonic combustion flow currently facilitate the design of air-breathing supersonic combustion ramjet (scramjet) engines. Measurements were made in supersonic axi-symmetric free jets of two scales. First, the measurement system was tested in a laboratory environment using a laboratory-scale burner (approx.10 mm at nozzle exit). The flow structures of the laboratory-burner were too small to be resolved with the CARS measurements volume, but the composition and temperature of the jet allowed the performance of the system to be evaluated. Subsequently, the system was tested in a burner that was approximately 6 times larger, whose length scales are better resolved by the CARS measurement volume. During both these measurements, weaknesses of the CARS system, such as sensitivity to vibrations and beam steering and inability to measure temperature or species concentrations in hydrogen fuel injection regions were indentified. Solutions were then implemented in improved CARS systems. One of these improved systems is a dual-pump broadband CARS technique called, Width Increased Dual-pump Enhanced CARS (WIDECARS). The two lowest rotational energy levels of hydrogen detectable by WIDECARS are H2 S(3) and H2 S(4). The detection of these lines gives the system the capability to measure temperature and species concentrations in regions of the flow containing pure hydrogen fuel at room temperature. WIDECARS is also designed for measurements of all the major species (except water) in supersonic combustion flows fueled with hydrogen and hydrogen/ethylene mixtures (N2, O2, H2, C2H4, CO, and CO2). This instrument can characterize supersonic combustion fueled with surrogate fuel mixtures of hydrogen and ethylene. This information can lead to a better understanding of the chemistry and performance of supersonic combustion fueled with cracked jet propulsion (JP)-type fuel.

Tedder, Sarah Augusta Umberger↗

Standoff Trace Chemical Sensing via Manipulation of Excited Electronic State Lifetimes

We present a technique for standoff trace chemical sensing that is based on the dependence of excited electronic state lifetimes on the amount of internal vibrational energy. Time resolved photoionization measurements show that the lifetime of the S1 state in N,N-dimethylisopropylamine (DMIPA) decreases exponentially with the amount of energy deposited into vibrational degrees of freedom. This property is employed to acquire spectral signatures of the molecule. Two nanosecond laser pulses are used, one (266 nm) to ionize the molecule through the S1 state and another, with tunable wavelength, to alter the lifetime of the S1 state by depositing energy into vibrations. Reduction of the S1 state lifetime results in a dip in ionization efficiency that is observed by remotely probing the laser-induced plasma with microwave radiation.

Rudakov, Fedor M↗

Effect of Longitudinal Oscillations on Downward Flame Spread over Thin Solid Fuels

Downward flame spread rates over vertically vibrated thin fuel samples are measured in air at one atmospheric pressure under normal gravity. Unlike flame spread against forced‐convective flows, the present results show that with increasing vibration acceleration the flame spread rate increases before being blown off at high acceleration levels causing flame extinction. A simple scaling analysis seems to explain this phenomenon, which may have important implications to flammability studies including in microgravity environments.

Flammability↗

Vibrational excitation of H2 by proton impact.

Measurement results are presented for the forward-scattered component of the absolute cross sections pertaining to proton- and deuteron-impact excitation of the first four vibrational levels of the electronic ground state of H2. The significance and implications of these results are discussed.

Herrero, F. A.↗

Electron impact cross sections for v = 0-1 vibrational excitation in CO at electron energies of 3 to 100 eV

The paper discusses the measurements of normalized, absolute differential cross-sections for electron-impact vibrational transition in CO. Integral and momentum-transfer cross-sections were obtained from these differential results; incident electron energies were in the 3 to 100 eV range, and the scattering angles were 10 to 135 deg. A comparison of these results with measurements made with pure vibrationally elastic cross-sections in N2, and with the data based on a two-potential theory for electron scattering from diatomic molecules showed that the present CO cross-sections are similar to those in N2. This indicates that the long-range effect of the small CO dipole moment is negligible in promoting vibrational excitation; moreover, a significant peak in the integral and momentum-transfer cross-sections is observed at 20 eV. Finally, the low-energy integral cross-sections are compared with a recent set of swarm data for vibrational excitation.

Chutjian, A.↗

Structural origins of the electronic properties of materials via time-resolved infrared spectroscopy

Time-resolved mid-infrared (TRIR) spectroscopy offers new opportunities to investigate how the molecular and structural properties of optoelectronic materials influence their electronic and transport states. This capability emerges from the ability to measure low energy electronic transitions in the mid-infrared that are related to delocalized states in materials and to simultaneously detect the vibrational properties of the materials that influence those states. Furthermore, the ability to simultaneously measure electronic and vibrational transitions in materials offers unprecedented opportunities to correlate structural dynamics of materials with their electronic and transport properties. Here, these capabilities are introduced by first describing the basic principles of TRIR spectroscopy used to examine electronic processes in materials. Then, several applications of TRIR spectroscopy are described in which measurements of the vibrational spectra of electronic excited states are probed as a means to correlate the structural properties of materials with the delocalization of their electronic states. In one example, exciton localization mechanisms in organic semiconductors are probed through vibrational spectra of the molecules in their excited states and correlated with their crystalline packing arrangements. Another example highlights the use of TRIR spectroscopy to examine singlet fission reaction dynamics through a combination of low energy electronic transitions and the vibrational spectra that are unique to the electronic states involved in the reaction. Finally, the use of TRIR spectroscopy to investigate charge carrier localization mechanisms in lead-halide perovskites is described, followed by an outlook of future applications of the technique in optoelectronic materials research.

36 MATERIALS SCIENCE↗

Acoustic measurement study 40 by 80 foot subsonic wind tunnel

An acoustical study conducted during the period from September 1, 1973 to April 30, 1974 measured sound pressure levels and vibration amplitudes inside and outside of the subsonic tunnel and on the tunnel structure. A discussion of the technical aspects of the study, the field measurement and data reduction procedures, and results are presentd, and conclusions resulting from the study which bear upon near field and far field tunnel noise, upon the tunnel as an acoustical enclosure, and upon the sources of noise within the tunnel drive system are given.

Source record↗

Measured Spacecraft Dynamic Effects on Atmospheric Science Instruments

On September 1991, NASA launched the Upper Atmosphere Research Satellite. In addition to its atmospheric science mission, spacecraft dynamic effects on science measurements were analyzed. The investigation included two in-flight experiments to determine how each on-board instrument, subsystem and environmental disturbance contributed to the spacecraft dynamic response and how these disturbances affected science measurements. Three case studies are presented which show the impact of spacecraft dynamic response on science measurements. In the first case, correlation of independent atmospheric meridional wind measurements taken by two instruments with the spacecraft dynamic response demonstrated that excessive vibration (exceeding instrument pointing requirements) resulted in wind measurement disagreement. In the second case, solar array disturbances produced a spacecraft response signature on radiometer measurements. The signature explicitly demonstrated that if an instrument has sufficient spatial and temporal resolution, spacecraft dynamic response could impact measurements. In the final case, correlation of an instrument's fine sun sensor data and CO2 measurements demonstrated the effect of temporal and spatial sampling resolution and active pointing control on science measurements. The sun sensor had a frequency modulated characteristic due to spacecraft vibration and the periodic scanning of another instrument which was not present on the CO2 measurements.

Woodard, Stanley E.↗

Intrinsic localized modes observed in the high-temperature vibrational spectrum of Nal.

Inelastic neutron measurements of the high-temperature lattice excitations in NaI show that in thermal equilibrium at 555 K an intrinsic mode, localized in three dimensions, occurs at a single frequency near the center of the spectral phonon gap, polarized along [111]. At higher temperatures the intrinsic localized mode gains intensity. Higher energy inelastic neutron and x-ray scattering measurements on a room-temperature NaI crystal indicate that the creation energy of the ground state of the intrinsic localized mode is 299 meV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of absorption by H2 in molecular clouds: A direct measurement of the H2:CO ratio

Vibrational absorption by H2 and CO has been searched for toward infrared sources embedded in molecular clouds. H2 was detected toward NGC 2024 IRS 2 and possibly toward NGC 2264 (GL 989). CO was detected toward both sources. The results are consistent with the H2 ortho:para ratio being equilibrated at the cloud temperature. Toward NGC 2024, H2:CO = (3700(sub -2600)(sup +3100)) (2 sigma limits), and toward NGC 2264, H2:CO less than 6000. Approximately one-third of all carbon is in gas-phase CO.

Lacy, J. H.↗