Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Storage System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Development of a Test-Bed for Testing and Refining EarthEn’s Supercritical CO 2 Based Energy Storage System

EarthEn’s energy storage concept leverages supercritical carbon dioxide (sCO 2 ) as a working fluid and relies on compact, high-performance components operating at elevated pressures and temperatures. To accelerate component development and reduce technical risk prior to larger-scale demonstrations, Oak Ridge National Laboratory (ORNL) developed a 100 kW-scale sCO 2 test-bed under a Cooperative Research and Development Agreement with EarthEn (CRADA NO. NFE-24-10050). The objective of the work was to design and construct a flexible experimental facility capable of reproducing key thermodynamic state points and heat-transfer conditions relevant to EarthEn’s thermal energy storage (TES) cycle, with particular emphasis on enabling development and evaluation of next-generation heat exchangers and TES concepts. The test-bed consists of a closed-loop sCO 2 circulation system housed within an open-topped enclosure. In its as-installed configuration, dense-phase sCO 2 is recirculated through a printed circuit recuperator, an electrically heated section, a throttling device used to simulate turbine expansion, and a water-cooled printed circuit heat exchanger that rejects heat to the building chilled-water system before returning to the pump. The pump is driven by a variable frequency drive, enabling controlled adjustment of flow and operating point. A comprehensive instrumentation suite was integrated to support both safe operation and high-quality data collection. Installed sensors include Coriolis flow meters for sCO 2 flow rate and density, resistance temperature detectors and thermocouples distributed throughout the loop (including the heated section and key heat exchanger ports), and pressure transducers for absolute and differential pressure measurements. The facility was designed to support high-pressure (19 MPa nominal) and high-temperature (575°C nominal) operation with credited overpressure protection provided by a rupture disk. Nominal operating conditions were selected to support 100 kW-class testing while maintaining flexibility for non-heated and heated shakedown, control development, and future integration of advanced TES test sections. In parallel with facility development, a system-level thermal-hydraulic model was created using Modelica-based tools to support component sizing, anticipate performance over targeted test conditions, and establish a framework for future model calibration against experimental data. At the conclusion of the project performance period, the facility was in final assembly, and the pressure boundary was nearly completed. However, several practical challenges associated with high-pressure/high-temperature systems and specialized component procurement impacted schedule and prevented initial pump-driven operation and full commissioning within the available resources. This report documents the as-built design, operating capabilities, and instrumentation, and it summarizes key lessons learned related to heater fabrication and testing, first-of-a-kind assembly factors, specialty flange supply constraints, and fill pump corrective actions. Finally, it outlines a phased plan for future commissioning and experimental campaigns, including control and instrumentation shakedown, heater characterization, model calibration, and testing at state points representative of EarthEn’s TES cycle.

25 ENERGY STORAGE↗

Arbitrage and Capacity Firming in Coordination with Day-Ahead Bidding of a Hybrid PV Plant

A hybrid PV plant (HPP) combines a photovoltaic (PV) plant with a battery energy storage system (BESS), which is considered a promising step towards the future of renewable power plants by the U.S. Department of Energy. When the renewable penetration reaches a significant level, a hybrid PV plant can bid in as a controllable thermal plant in the future electricity market. In this study, a bidding and BESS scheduling model is proposed for the HPP. The robust optimization (RO) technique has been utilized to identify the worst-case scenario of uncertainties during the bidding process. To address the overly conservative issue of the single-stage RO, we have decoupled the BESS schedule for arbitrage and PV capacity firming by a two-stage RO formulation. By comparing the output of single-stage RO and two-stage RO, the two-stage RO bids and schedules in a more aggressive manner, which increases the income of HPP. Also, the penalty of under-generation is considered in our model so that the day-ahead bidding decision and arbitrage schedules can be adjusted based on the potential UNDER-GENERATION penalty. Because the proposed model is non-convex and contains multi-stages, the Column-and-Constraint Generation (C&CG) algorithm is applied to the model as the solution. The proposed model has shown better economic performance compared to a state-of-art single-stage bidding method in case studies.

BESS scheduling↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Controls for Electrified Aircraft Propulsion

Advanced electrified aircraft propulsion (EAP) concepts with integrated power, propulsion, and thermal systems require the development of equally sophisticated controllers to fly safe and efficient missions. Hybrid electric aircraft utilize electric machines mechanically coupled to the engine shafts to extract and insert power for a variety of purposes. Additionally, electric machines may drive propulsive fans pulling from a combination of on-board energy storage devices and engine extracted power. NASA’s investment in hybrid electric aircraft hardware-in-the-loop testing enables controls research on representative engine models using a novel emulation and scaling methodology. High-voltage, high-power electrical powertrain presents several technical risks at altitude. High-power requires high efficiency to minimize losses. Superconducting electric machines and power distribution research at NASA has identified key challenges with potential controls solutions. These risks necessitate the development of controllers robust to model uncertainty, disturbances, and fault conditions. System health management and fault detection schemes play an important role in a multi-layer controls approach that utilizes a supervisor which oversees inner loops for the highly coupled power, propulsion, and thermal systems. Such a supervisory controller enables coordinates energy transfer between engines, energy storage devices, electric machines, propulsors, and heat exchangers. Existing methods have shown an improvement in engine operability using the hybrid electric powertrain.

Halle E Buescher↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

Renewable electricity capacity planning with uncertainty at multiple scales

Abstract We formulate and compare optimization models of investment in renewable generation using a suite of social planning models that compute optimal generation capacity investments for a hydro-dominated electricity system where inflow uncertainty results in a risk of energy shortage. The models optimize the expected cost of capacity expansion and operation allowing for investments in hydro, geothermal, solar, wind, and thermal plant, as well as battery storage for smoothing load profiles. A novel feature is the integration of uncertain seasonal hydroelectric energy supply and short-term variability in renewable supply in a two-stage stochastic programming framework. The models are applied to data from the New Zealand electricity system and used to estimate the costs of moving to a 100% renewable electricity system by 2035. We also explore the outcomes obtained when applying different forms of CO 2 constraint that limit respectively non-renewable capacity, non-renewable generation, and CO 2 emissions on average, almost surely, or in a chance-constrained setting, and show how our models can be used to investigate the merits of a proposed pumped-hydro scheme in New Zealand’s South Island.

Ferris, Michael C.↗

Design of a pressurized lunar rover

A pressurized lunar rover is necessary for future long-term habitation of the moon. The rover must be able to safely perform many tasks, ranging from transportation and reconnaissance to exploration and rescue missions. Numerous designs were considered in an effort to maintain a low overall mass and good mobility characteristics. The configuration adopted consists of two cylindrical pressure hulls passively connected by a pressurized flexible passageway. The vehicle has an overall length of 11 meters and a total mass of seven metric tons. The rover is driven by eight independently powered two meter diameter wheels. The dual-cylinder concept allows a combination of articulated frame and double Ackermann steering for executing turns. In an emergency, the individual drive motors allow the option of skid steering as well. Two wheels are connected to either side of each cylinder through a pinned bar which allows constant ground contact. Together, these systems allow the rover to easily meet its mobility requirements. A dynamic isotope power system (DIPS), in conjunction with a closed Brayton cycle, supplied the rover with a continuous supply of 8.5 kW. The occupants are all protected from the DIPS system's radiation by a shield of tantalum. The large amount of heat produced by the DIPS and other rover systems is rejected by thermal radiators. The thermal radiators and solar collectors are located on the top of the rear cylinder. The solar collectors are used to recharge batteries for peak power periods. The rover's shell is made of graphite-epoxy coated with multi-layer insulation (MLI). The graphite-epoxy provides strength while the thermally resistant MLI gives protection from the lunar environment. An elastomer separates the two materials to compensate for the thermal mismatch. The communications system allows for communication with the lunar base with an option for direct communication with earth via a lunar satellite link. The various links are combined into one signal broadcast in the S-band at 2.3 GHz. The rover is fitted with a parabolic reflector disk for S-band transmission, and an omnidirectional antenna for local extravehicular activity (EVA) communication. The rover's guidance, navigation, and control subsystem consists of an inertial guidance system, an orbiting lunar satellite, and an obstacle avoidance system. In addition, the rover is equipped with a number of external fixtures including two telerobotic arms, lights, cameras, EVA storage, manlocks, a docking fixture, solar panels, thermal radiators, and a scientific airlock. In conclusion, this rover meets all of the design requirements and clearly surpasses them in the areas of mobility and maneuverability.

Bhardwaj, Manoj↗

Enhancing building resilience in cold climates: Integrating heat pump technologies with renewable energy

As electrification advances and Cold Climate Heat Pump technology progresses, ensuring grid stability becomes increasingly critical for effective heating in cold climates. However, natural disasters, especially during winter, pose significant threats to grid stability, impacting the reliability of air-source heat pumps. Despite these challenges, the integration of renewable energy sources and storage solutions in heating systems has not been extensively studied within the context of resilience. Here, this paper delves into the literature on renewable-powered heat pumps to assess their potential in enhancing building resilience in U.S. cold climate zones, which are particularly susceptible to extreme weather and grid disruptions. By leveraging renewable sources—solar, geothermal, and water—in conjunction with heat pump technology and supported by thermal or battery storage, this approach aims to provide a dependable solution for maintaining indoor heating during grid failures. Our analysis begins with a review of various renewable energy sources suitable for heat pumps, followed by an exploration of their application in cold climate regions across the U.S., and discussions on potential integration strategies with heat pump systems. This study highlights the advantages and suitability of solar irradiance and geothermal resources, emphasizing the importance of tailored, site-specific assessments to maximize energy efficiency and resilience. Additionally, it outlines the economic and environmental considerations necessary for implementing such systems and identifies potential challenges and areas for future research to facilitate the broader integration of renewable energy in heating solutions for enhanced resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Oxygen Liquefaction with Transient Flow Rates for ISRU Systems

Human occupation of lunar and Martian surfaces requires in-situ resource utilization (ISRU) to create a sustainable environment with the limited resources available in space. Fuel and oxidizer generation is essential for developing a refueling capability for spacecraft, significantly reducing the propellant mass required for landing. Liquefaction systems are a key step in producing and storing cryogenic liquids such as oxygen, hydrogen, and methane. All those fluids are critical to propulsion, life support, and other spacecraft systems. NASA has previously confirmed the presence of water on the Moon and an electrolysis process can be used to separate the oxygen from the hydrogen molecules. Oxygen has also been found within lunar regolith and can be separated through ISRU processes. The extracted oxygen gas can then be liquefied inside a storage tank with tube-on-tank heat exchangers for future use as an oxidizer for propellants. While steady state liquefaction performance is easy to model, power limitations and cyclical environments caused by the change in Sun exposure between day and night periods potentially call for transient operations. The following analysis was performed using the Thermal Desktop software to investigate how various transient gaseous oxygen (GOX) flow rates impact the production and storage of liquid oxygen (LOX) in a 1-g liquefaction system. Variations of sinusoidal and exponential step functions were selected to model potential GOX flow rates that could be experienced by ISRU systems on lunar or Martian surfaces. This early computational analysis provides some insight on how transient operations impact oxygen liquefaction systems and helps illustrate operational questions to explore experimentally throughout the design process.

Cryogenic Fluid Management↗

Nonelastomeric Rod Seals for Advanced Hydraulic Systems

Advanced high temperature hydraulic system rod sealing requirements can be met by using seals made of nonelastomeric (plastic) materials in applications where elastomers do not have adequate life. Exploratory seal designs were optimized for advanced applications using machinable polyimide materials. These seals demonstrated equivalent flight hour lives of 12,500 at 350 F and 9,875 at 400 F in advanced hydraulic system simulation. Successful operation was also attained under simulated space shuttle applications; 96 reentry thermal cycles and 1,438 hours of vacuum storage. Tests of less expensive molded plastic seals indicated a need for improved materials to provide equivalent performance to the machined seals.

Hady, W. F.↗

Measurement Of Thermal Conductivity Of Molten LiF

Report discusses experimental study of thermal conductivity of molten lithium fluoride. Study motivated by consideration of material for use as energy-storage medium in solar power systems.

Jaworske, Donald A.↗

Hybrid Thermal Control Testing of a Cryogenic Propellant Tank

This report presents the experimental results of a hybrid thermal control system, one that integrates a passive system (multi-layer insulation) with an active system (a mechanical cyrocooler) applied to cryogenic propellant storage. These experiments were performed on a 1.39 m diameter spherical propellant tank filled with LH2 while installed in an evacuated chamber. The tank heat transfer to the cryocooler was accomplished with a condenser installed in the ullage of the tank and mated to the second stage of the cooler, and by conduction, through copper leaves mated to the first stage of the cooler. The first hybrid system test was performed with both the condenser and the leaves, a configuration that had excess capacity to remove the heat entering the tank; the second test was performed with only the condenser, with a capacity closely matched to the tank heating rate. In both of these tests, the goal of zero boil-off was achieved.

Plachta, David W.↗

Cryo Propulsive Stage: HEFT Phase 2 Point of Departure

The CPS is an in-space high thrust propulsive stage based largely on state of the practice design for launch vehicle upper stages. However, unlike conventional propulsive stages, it also contains power generation and thermal control systems to limit the loss of liquid hydrogen and oxygen due to boil-off during extended in-space storage. The CPS provides high thrust GV for rapid transfer of in-space elements to their destinations or staging points (i.e., E-M L1). The CPS is designed around a block upgrade strategy to provide maximum mission/architecture flexibility: a) Block 1 CPS: Short duration flight times (hours), passive cryofluid management. b) Block 2 CPS: Long duration flight times (days/weeks/months), active and passive cryofluid management.

Martinez, Roland M.↗

Cryogenic Propulsion Stage

The CPS is an in-space cryogenic propulsive stage based largely on state of the practice design for launch vehicle upper stages. However, unlike conventional propulsive stages, it also contains power generation and thermal control systems to limit the loss of liquid hydrogen and oxygen due to boil-off during extended in-space storage. The CPS provides the necessary (Delta)V for rapid transfer of in-space elements to their destinations or staging points (i.e., E-M L1). The CPS is designed around a block upgrade strategy to provide maximum mission/architecture flexibility. Block 1 CPS: Short duration flight times (hours), passive cryo fluid management. Block 2 CPS: Long duration flight times (days/weeks/months), active and passive cryo fluid management.

Jones, David↗

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

Experimental Characterization of High-Surface Area Thermal Energy Storage

There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.

25 ENERGY STORAGE↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A radiological assessment of nuclear power and propulsion operations near Space Station Freedom

Scenarios were identified which involve the use of nuclear power systems in the vicinity of Space Station Freedom (SSF) and their radiological impact on the SSF crew was quantified. Several of the developed scenarios relate to the use of SSF as an evolutionary transportation node for lunar and Mars missions. In particular, radiation doses delivered to SSF crew were calculated for both the launch and subsequent return of a Nuclear Electric Propulsion (NEP) cargo vehicle and a Nuclear Thermal Rocket (NTR) personnel vehicle to low earth orbit. The use of nuclear power on co-orbiting platforms and the storage and handling issues associated with radioisotope power systems were also explored as they relate to SSF. A central philosophy in these analyses was the utilization of a radiation dose budget, defined as the difference between recommended dose limits from all radiation sources and estimated doses received by crew members from natural space radiations. Consequently, for each scenario examined, the dose budget concept was used to identify and quantify constraints on operational parameters such as launch separation distances, returned vehicle parking distances, and reactor shutdown times prior to vehicle approach. The results indicate that realistic scenarios do not exist which would preclude the use of nuclear power sources in the vicinity of SSF. The radiation dose to the SSF crew can be maintained at safe levels solely by implementing proper and reasonable operating procedures.

Bolch, Wesley E.↗