Broadband ultrafast-laser-absorption imaging in the ultraviolet for spatiotemporally resolved measurements of temperature and CN
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Wicking structures have been widely used within passive heat transfer devices with high heat fluxes, such as heat pipes, to enhance their thermal performance. While wicking structures promote capillary pumping of the working fluid as well as thin film evaporation, they can result in capillary evaporation and further enhances the evaporation heat transfer. In this study, a 0.5 mm thick layer of 105 microns sintered copper particles was added to the inner wall of a copper tube, aiming to enhance the heat transfer characteristics by taking advantage of capillary evaporation. Acetone was chosen as the working fluid, and the performance of an evaporation tube was tested for power inputs of 10, 30, 50, and 70 W. For each power input, trials were run at inclination angles varying from -90° and 90° to investigate the capillary effects. The temperature measurements showed that the temperature distribution along the evaporation tube is always downward sloping, meaning the temperature at the fluid inlet is larger than the outlet. Interestingly, the surface temperature at some locations is less than the outlet temperature, indicating the effect of capillary evaporation. In addition, a theoretical investigation was performed to investigate the effects of the particle size on the thermal performance of the evaporation tube and found that particle sizes affect capillary evaporation.
Abstract not provided.
Performance of five silicon-based reference cells is examined on a single-axis tracking surface. The reference cells' output are modeled using one-minute sampled spectral irradiance and reference cell temperature measurements. The model also incorporates spectral responsivity data for the reference cell. The transmission of light through the glazing multiplies the sum over all appropriate wavelengths of temperature adjusted reference cell responsivity times the measured spectral irradiance. Modeled reference cell output is compared with measured reference cell output under clear sky and totally cloudy sky conditions. For each reference cell the ratio of modeled to measured output varies by less than 2% over the year.
Several experimental disciplines require simultaneous neutron flux and temperature monitoring. This paper provides the groundwork on a diamond sensor concept that could be used in harsh environments where the limits of current technologies are exceeded. Here, we present initial results on the functionality of a multimodal diamond sensor, which can simultaneously sense the presence of alpha particles at a few counts per second at temperatures up to 494 K. Such a sensor may also have applications where both charged particles or neutron detection and temperature measurement are simultaneously desired.
This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.
The application of CO 2 chirped-probe-pulse (CPP) fs coherent anti-Stokes Raman scattering (CARS) for flame thermometry is discussed. A phenomenological model for CO 2 /O 2 CPP fs CARS was developed, and the simulations showed the potential for CO 2 temperature measurements free of interferences from O 2 and with no contribution from the nonresonant background by using a long-time delay for the chirped probe pulse. The accuracy and precision for CO 2 CPP fs CARS thermometry is compared with N 2 CPP fs CARS thermometry for temperatures between 295 K and 1420 K. The measurement accuracy for the CO 2 measurements is comparable with that for the N 2 measurements, while the precision for the CO 2 temperature measurements is significantly better at lower temperatures. In conclusion, we also demonstrate that accurate flame thermometry using a single set of laser parameters can be achieved using the delayed CPP approach.
Concentrating Solar Power (CSP) generation is an attractive option for low-emission power generation; however, the high costs of thermal storage associated with concentrating solar create a large barrier for their use and adaptation into modern life. Lowering their operation costs, while maintaining high thermal storage and transfer performance is essential. Solid particle-based heat exchange systems can reduce CSP cost but are often less efficient. Efforts to increase their performance have led to use of binary size particle mixes. Presented is an optical-based thermal analysis technique used to measure near-wall thermal conductivity of particle beds essential in determining their heat exchanger efficiency. Modulated Photothermal Radiometry is used to make dynamic temperature measurements, allowing for the extraction of the most relevant thermal properties like thermal conductivity, specific heat, and effusivity. The system uses a modulated laser source causing a damped periodic heat flux, resulting in a frequency and thermal property dependent surface temperature, of which is measured using radiometry. Lock-In techniques are used to extrapolate the amplitude of the signal. Plotting the amplitude against the root angular frequency allows for effusivity measurement by ratio to a known sample. Using specific heat measurements from literature and density measurements, the thermal conductivity of the particle mixes can be calculated. The simplicity of MPTR to probe through the depth of the bed is ideal for use in CSP for dynamic thermal performance monitoring.
A spectrally resolved Rayleigh/Mie scattering diagnostic was developed to measure temperature and wing-spanwise velocity in the vicinity of an ASTOVL aircraft model in the Lewis 9 x 15 Low Speed Wind Tunnel. The spectrum of argon-ion laser light scattered by the air molecules and particles in the flow was resolved with a Fabry-Perot interferometer. Temperature was extracted from the spectral width of the Rayleigh scattering component, and spanwise gas velocity from the gross spectral shift. Nozzle temperature approached 800 K, and the velocity component approached 30 m/s. The measurement uncertainty was about 5 percent for the gas temperature, and about 10 m/s for the velocity. The large difference in the spectral width of the Mie scattering from particles and the Rayleigh scattering from gas molecules allowed the gas temperature to be measured in flow containing both naturally occurring dust and LDV seed (both were present).
Flame temperatures in nonsooting and sooting environments were successfully measured by radiometry for pre-mixed propane-oxygen laminar flames stabilized on a water-cooled, porous sintered-bronze burner. The measured temperatures in the nonsooting flames were compared with fine-wire thermocouple measurements. The results show excellent agreement below 1700 K, and when the thermocouple measurements were corrected for radiation effects, the agreement was good for even higher temperatures. The benefits of radiometry are: (1) the flow is not disturbed by an intruding probe, (2) calibration is easily done using a blackbody source, and (3) measurements can be made even with soot present. The theory involved in the radiometry measurements and the energy balance calculations used to correct the thermocouple temperature measurements are discussed.
We demonstrate the use of hybrid rotational femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman spectroscopy (HR-CARS) as a technique for temperature measurements in nitrogen gas at high pressures and temperatures. A broadband pulse shaper-adjusted 42 fs pulse interacts with a narrow-bandwidth, frequency-upconverted 5.5 ps pulse in a cell containing N 2 at pressures of 1–70 atm and temperatures of 300–1000 K. A computational code is used to model spectra and fit experimental results to obtain best-fit temperatures. We demonstrate good qualitative fits as well as good accuracy and precision between thermocouple measured and best-fit temperatures over the explored pressure and temperature regimes. The overall average percentage temperature difference between thermocouple measurements and best-fit temperatures is − <#comment/> 0 . 3 % <#comment/> with a standard deviation of 7.1%, showing the suitability of HR-CARS for characterizing high-pressure and -temperature environments.
We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.