Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies

A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental procedures, processes of analysis, and uncertainty determination are outlined, and typical pressure profiles are compared with a new gas dynamics solver and empirical correlations developed across multiple shock tube facilities. Preliminary reactive mixture analyses are included with further investigation of the mixtures outlined.

47 OTHER INSTRUMENTATION↗

Multiaxial Plastic Deformation of Zircaloy-4 Nuclear Fuel Cladding Tubes

Here, this work is motivated by the desire to devise an internal pressure test that can mimic a displacement-controlled loading scenario and demonstrate how to apply the multiaxial stress and strain data from the test to develop an elastic/plastic constitutive model for a thin-walled tubular component. This is achieved by conducting simultaneous measurements of tangential and axial strain during the pressure test and integrating these strain measures into a feedback loop with the pressure controller. It is shown how data from such a test can be used to develop a large mechanical property data set relevant to biaxial loading conditions. The data obtained have high confidence evidenced by their low variability and alignment with other literature studies. Additionally, data from these internal pressure tests combined with full-tube axial tensile tests allow for the derivation of the Hill anisotropic yield function. The developed Hill yield function is validated by comparing the plastic strain ratios from the full-tube tension tests and by comparing the predicted yield stress in the tangential direction with measured values from ring tension tests in a previous study.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, and the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NONLINEAR MULTISCALE SIMULATION OF TURBULENT FLUX TUBES

A new method for the full nonlinear computation of sets of turbulent field lines has recently been introduced that allows inclusion of the equivalent of more than four decades of turbulent scales with a fully three-dimensional distribution of wavevectors. The integration scheme is here detailed, which, through transformation of the set of differential equations into mappings, compounds the efficiency and accuracy of the method. The potential of the method is then demonstrated with multiscale simulations of magnetic flux tubes ranging over nearly four decades of length scales both along and across the background field. Magnetic flux tubes of various sizes are computed for a turbulence spectrum typical of the quiet slow solar wind near 1 AU. Implications of the simulation results for the transport of energetic particles, and in particular, for the interpretation of impulsive solar-energetic-particle and upstream ion-event observations are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

An analytical approach to scattering between two thin magnetic flux tubes in a stratified atmosphere

We expand on recent studies to analytically model the behavior of two thin flux tubes interacting through the near- and acoustic far-field. The multiple scattering that occurs between the pair alters the absorption and phase of the outgoing wave when compared to non-interacting tubes. We have included both the sausage and kink scatter produced by the pair. It is shown that the sausage mode's contribution to the scattered wave field is significant, and plays an equally important role in the multiple scattering regime. A disparity between recent numerical results and analytical studies, in particular the lack of symmetry between the two kink modes, is addressed. This symmetry break is found to be caused by an incorrect solution for the near-field modes.

79 ASTRONOMY AND ASTROPHYSICS↗

GENERATION OF MAGNETOHYDRODYNAMIC WAVES IN LOW SOLAR ATMOSPHERIC FLUX TUBES BY PHOTOSPHERIC MOTIONS

Recent ground- and space-based observations reveal the presence of small-scale motions between convection cells in the solar photosphere. In these regions, small-scale magnetic flux tubes are generated via the interaction of granulation motion and the background magnetic field. This paper studies the effects of these motions on magnetohydrodynamic (MHD) wave excitation from broadband photospheric drivers. Numerical experiments of linear MHD wave propagation in a magnetic flux tube embedded in a realistic gravitationally stratified solar atmosphere between the photosphere and the low choromosphere (above β = 1) are performed. Horizontal and vertical velocity field drivers mimic granular buffeting and solar global oscillations. A uniform torsional driver as well as Archimedean and logarithmic spiral drivers mimic observed torsional motions in the solar photosphere. The results are analyzed using a novel method for extracting the parallel, perpendicular, and azimuthal components of the perturbations, which caters to both the linear and non-linear cases. Employing this method yields the identification of the wave modes excited in the numerical simulations and enables a comparison of excited modes via velocity perturbations and wave energy flux. The wave energy flux distribution is calculated to enable the quantification of the relative strengths of excited modes. The torsional drivers primarily excite Alfvén modes (≈60% of the total flux) with small contributions from the slow kink mode, and, for the logarithmic spiral driver, small amounts of slow sausage mode. The horizontal and vertical drivers primarily excite slow kink or fast sausage modes, respectively, with small variations dependent upon flux surface radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Event-by-Event Study of Space-Time Dynamics in Flux-Tube Fragmentation

In the semi-classical description of the flux-tube fragmentation process for hadron production and hadronization in high-energy $e^+e^-$ annihilations and $pp$ collisions, the rapidity-space-time ordering and the local conservation laws of charge, flavor, and momentum provide a set of powerful tools that may allow the reconstruction of the space-time dynamics of quarks and mesons in exclusive measurements of produced hadrons, on an event-by-event basis. We propose procedures to reconstruct the space-time dynamics from event-by-event exclusive hadron data to exhibit explicitly the ordered chain of hadrons produced in a flux tube fragmentation. As a supplementary tool, we infer the average space-time coordinates of the $q$-$\bar q$ pair production vertices from the $\pi^-$ rapidity distribution data obtained by the NA61/SHINE Collaboration in $pp$ collisions at $\sqrt{s}$ = 6.3 to 17.3 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A model for the Global Quantum Efficiency for a TPB-based wavelength-shifting system used with photomultiplier tubes in liquid argon in MicroBooNE

We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons ($N_{\rm PE}$) given the known systematic errors on the simulation parameters. We compare results from four measurements of the $N_{\rm PE}$ determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of $0.0055\pm0.0009$ for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray shadow imprint of hydrodynamic instabilities on the surface of inertial confinement fusion capsules by the fuel fill tube

Measurements of hydrodynamic instability growth for a high-density carbon ablator for indirectly driven inertial confinement fusion implosions on the National Ignition Facility are reported. We observe significant unexpected features on the capsule surface created by shadows of the capsule fill tube, as illuminated by laser-irradiated x-ray spots on the hohlraum wall. These shadows increase the spatial size and shape of the fill tube perturbation in a way that can significantly degrade performance in layered implosions compared to previous expectations. The measurements were performed at a convergence ratio of ~2 using in-flight x-ray radiography. The initial seed due to shadow imprint is estimated to be equivalent to ~50–100 nm of solid ablator material. As a result, this discovery has prompted the need for a mitigation strategy for future inertial confinement fusion designs as proposed here.

42 ENGINEERING↗

Elastic strain tensor of zirconium hydrides in Zr2.5%Nb pressure tubes by synchrotron X-ray diffraction

Zirconium alloys are used in fuel cladding and structural components of nuclear power plants. Hydrogen enters the Zr matrix during plant operation and precipitates as hydride particles that degrade the mechanical properties of the alloy, limiting service life. Knowledge of the stress state within hydride precipitates is important to understand stress-induced degradation mechanisms such as delayed hydride cracking, but no direct quantification has yet been reported in the literature. Here, measurements are reported of the average elastic strain tensor within δ zirconium hydride precipitates in Zr2.5%Nb pressure tube material from CANDU power plants. Complete intensity and strain pole figures for the hydride were obtained by synchrotron X-ray diffraction experiments on specimens with hydrogen contents ranging from ~100 wt p.p.m. hydrogen to nearly 100% δ-hydride. Zirconium hydride precipitates by a process involving a martensitic transformation, with two hydride variants possible from a single α-Zr grain. A synthetic model of the hydride crystallographic texture allowed the interpretation of the measured strain pole figures and quantification of the elastic strain tensor for both texture components. It was found that the two variants appear in nearly equal proportion but with different stress states, differing in the sign of the shear strain components (~±3000 µ$\epsilon$). This difference is possibly associated with the shear movement of Zr atoms during the phase transformation. This suggests that hydride clusters are composed of stacks of smaller hydrides in alternating hydride variants. Stresses were estimated from a set of rather uncertain hydride elastic constants. Overall, both variants showed compressive strains along the tube axial direction (~5000 µ$\epsilon$). For low hydrogen concentrations, the hydrides' stress tensor is dominated by compressive stresses of ~300 MPa along the axial direction, probably caused by the elongated morphology of hydride clusters along this direction, and variant-dependent shear stresses of ~±100 MPa, probably from the shear movement of the Zr atoms involved in the phase transformation.

36 MATERIALS SCIENCE↗

Scalable measurements of tow architecture variability in braided ceramic composite tubes

Abstract The performance of braided ceramic matrix composites has been shown to depend on the spatial arrangement of tows; therefore, a new class of tools is required to measure irregularities in the composite architecture for components with intricate geometries. We report a scalable and robust reconstruction technique built upon stereoscopic digital image correlation that is able to efficiently measure the position of tows in arbitrarily shaped composites. This method was applied to triaxially braided ceramic matrix composite tubes intended for use as nuclear fuel cladding, which revealed both long‐range “systematic” tow packing defects associated with the manufacturing process and short‐range “intrinsic” defects due to the braid architecture. These findings suggested that the character of tow spacing variation in braided composite tubes was substantially more complex than in planar woven composites. These measurements are expected to lead to improved processing of braided composites and to facilitate the design of statistically representative virtual specimens for finite element modeling.

Heim, Frederick M.↗

Probing the Effects of NO x and SO x Impurities on Oxy-Fuel Combustion in Supercritical CO 2 : Shock Tube Experiments and Chemical Kinetic Modeling

The direct-fired supercritical carbon dioxide cycles are one of the most promising power generation methods in terms of their efficiency and environmental friendliness. Two important challenges in implementing these cycles are the high pressure (300 bar) and high CO 2 dilution (>80%) in the combustor. The design and development of supercritical oxy-combustors for natural gas require accurate reaction kinetic models to predict the combustion outcomes. The presence of a small amount of impurities in natural gas and other feed streams to oxy-combustors makes these predictions even more complex. During oxy-combustion, trace amounts of nitrogen present in the oxidizer is converted to NO x and gets into the combustion chamber along with the recirculated CO 2 . Similarly, natural gas can contain a trace amount of ammonia and sulfurous impurities that get converted to NO x and SO x and get back into the combustion chamber with recirculated CO 2 . In this work, a reaction model is developed for predicting the effect of impurities such as NO x and SO x on supercritical methane combustion. The base mechanism used in this work is GRI Mech 3.0. H 2 S combustion chemistry is obtained from Bongartz et al. while NOx chemistry is from Konnov. The reaction model is then optimized for a pressure range of 30–300 bar using high-pressure shock tube data from the literature. It is then validated with data obtained from the literature for methane combustion, H 2 S oxidation, and NO x effects on ignition delay. The effect of impurities on CH 4 combustion up to 16 atm is validated using NO x -doped methane studies obtained from the literature. In order to validate the model for high-pressure conditions, experiments are conducted at the UCF shock tube facility using natural gas identical mixtures with N 2 O as an impurity at ~100 bar. Current results show that there is a significant change in ignition delay with the presence of impurities. A comparison is made with experimental data using the developed model and predictions are found to be in good agreement. The model developed was used to study the effect of impurities on CO formation from sCO 2 combustors. It was found that NO x helps in reducing CO formation while the presence of H 2 S results in the formation of more CO. The reaction mechanism developed herein can also be used as a base mechanism to develop reduced mechanisms for use in CFD simulations.

Energy & Fuels↗

Numerical Study of Solar Receiver Tube With Modified Surface Roughness for Enhanced and Selective Absorptivity in Concentrated Solar Power Tower

Abstract Concentrated solar power (CSP) is a reliable renewable energy source that is progressively lowering its cost of energy. However, the heat loss due to reflected and emitted radiation hinders the maximum achievable thermal efficiency for solar receiver tubes on the solar tower. Current solar selective coatings cannot withstand the high temperatures that come with state-of-the-art CSP towers often needing to be recoated soon after initial operation. We intend to use Inconel 718 with different additive manufacturing (AM) practices to construct surfaces that allow for more light-trapping to occur. By adjusting printing parameters, we can tailor a surface to allow for more absorption while diminishing emitted radiation heat loss. By using COMSOL Multiphysics, we can generate these theoretical surfaces to emulate a printed surface, and using the coupled Multiphysics we can simulate how the surface dictates radiation properties. Our results show that by having a rougher surface we can enhance the absorptivity of Inconel 718 (IN718) by 38.8%. We expect this work to transform how solar absorber tubes are manufactured without using selective coatings and supplement the US Department of Energy (DOE) 2030 SunShot Initiative.

14 SOLAR ENERGY↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-89: Assessment of CT Radiation Dose and Image Quality for An Automated Tube Potential Selection Algorithm Using Pediatric Anthropomorphic and ACR Phantoms

Purpose: To assess the impact of General Electrics automated tube potential algorithm, kV assist (kVa) on radiation dose and image quality, with an emphasis on optimizing protocols based on noise texture. Methods: Radiation dose was assessed by inserting optically stimulated luminescence dosimeters (OSLs) throughout the body of a pediatric anthropomorphic phantom (CIRS). The baseline protocol was: 120 kVp, 80 mA, 0.7s rotation time. Image quality was assessed by calculating the contrast to noise ratio (CNR) and noise power spectrum (NPS) from the ACR CT accreditation phantom. CNRs were calculated according to the steps described in ACR CT phantom testing document. NPS was determined by taking the 3D FFT of the uniformity section of the ACR phantom. NPS and CNR were evaluated with and without kVa and for all available adaptive iterative statistical reconstruction (ASiR) settings, ranging from 0 to 100%. Each NPS was also evaluated for its peak frequency difference (PFD) with respect to the baseline protocol. Results: For the baseline protocol, CNR was found to decrease from 0.460 ± 0.182 to 0.420 ± 0.057 when kVa was activated. When compared against the baseline protocol, the PFD at ASiR of 40% yielded a decrease in noise magnitude as realized by the increase in CNR = 0.620 ± 0.040. The liver dose decreased by 30% with kVa activation. Conclusion: Application of kVa reduces the liver dose up to 30%. However, reduction in image quality for abdominal scans occurs when using the automated tube voltage selection feature at the baseline protocol. As demonstrated by the CNR and NPS analysis, the texture and magnitude of the noise in reconstructed images at ASiR 40% was found to be the same as our baseline images. We have demonstrated that 30% dose reduction is possible when using 40% ASiR with kVa in pediatric patients.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-04: A Novel Phantom to Evaluate Longitudinal and Angular Automatic Tube Current Modulation (ATCM) in CT

Purpose: To manufacture a phantom specifically designed for the purpose of evaluating the performance of the longitudinal and angular automatic tube current modulation (ATCM) on modern CT scanners. Methods: In order to evaluate angular ATCM, the phantom has an elliptical cross section (aspect ratio 3:2). To evaluate longitudinal ATCM, the phantom consists of 3 sections, with different major axes (25 cm, 30 cm and 35 cm). Each section is 15 cm long in the longitudinal direction. Between each section is a smooth transition. The phantom was milled from a solid block of PMMA. ATCM performance is evaluated by 1) analyzing the applied tube current for each slice of the phantom and 2) analyzing the distribution of image noise (σ) along the scan direction at different positions in the phantom. A demonstration of the ATCM performance evaluation is given by investigating the effects of miscentering during a CT scan. Results: The developed phantom has proven useful for evaluating both the longitudinal and angular ATCM on modern CT scanners (spiral collimations ≥ 4 cm). Further benefits are the smooth transitions between the sections that prevent abnormal responses in the ATCM and the invariant sections that provide a means for investigating the stability of image noise. The homogeneity of the phantom makes image noise at different positions along the scan direction easy to quantify, which is crucial to understand how well the applied ATCM can produce a desired image quality. Conclusion: It is important to understand how the ATCM functions on CT scanners as it can directly affect dose and image quality. The phantom that has been developed is a most valuable tool to understand how different variables during a scan can affect the outcome of the longitudinal and angular ATCM.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗