Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST STATISTIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Multiwavelength monitoring of the BL Lacertae object PKS 2155-304. 4: Multiwavelength analysis

Simultaneous X-ray, ultraviolet, optical, infrared, and radio monitoring data were used to test and constrain models of continuum emission from the BL Lacertae object PKS 2155-304. Intensively sampled ultraviolet and soft X-ray light curves showed a clear temporal correlation with the X-rays leading the ultraviolet by 2-3 hr. This lag was found to be significantly different from zero after an exhaustive comparison of four different techniques for measuring temporal correlations. Variations in the ultraviolet trough optical wave bands were also strongly correlated, with no measurable lag down to limiting timescales of approximately less than 1-2 hr. This strong correlation extends to the near-infrared, but the less intensive sampling precludes measurement of any lag beyomnd an upper limit of approximately less than 1 day. These lags and limits of the order of hours are much shorter than most rapid observed single-band variations. Because of the very sparse radio sampling, it was not possible to measure quantitatively the correlation and lag with shorter wavelengths, but the data do suggest that the radio may lag the optical/ultraviolet by approximately 1 week, with longer delays and weaker variations to longer radio wavelengths. The epoch-folding Q(exp 2) statistic was used to test for periodicity, and no evidence for strict or quasi-periodicity was found in any of the light curves. Because they lead the lower frequencies, the soft X-rays (approximately less than 1 keV) cannot arise from synchrotron self-Compton scattering. These results also rule out the accretion disk model, which predicts a measurable lag between ultraviolet/optical wavelength bands and a correlation between hardness and brightness, neither of which were seen. They are consistent with the entire radio through X-ray continuum arising from direct synchrotron emission from a relativistic jet. However, the tapered jet model, in which the X-ray emission is produced closer in, has problems explaining the magnitude of the ultraviolet/X-ray lag, because the X-ray-emitting electrons have very short lifetimes (t(sub 1/2) much less than 1 s). The result that the lag is much smaller than the variability timescale suggests instead that the radiation may be produced in a flattened region such as a shock front.

Edelson, R.↗

Non-diffusive, non-local transport in fluids and plasmas

A review on non-diffusive transport in fluids and plasmas is presented. In the fluid context, non-diffusive chaotic transport by Rossby waves in zonal flows is studied following a Lagrangian approach. In the plasma physics context the problem of interest is test particle transport in pressure-gradient-driven plasma turbulence. In both systems the probability density function (PDF) of particle displacements is strongly non-Gaussian and the statistical moments exhibit super-diffusive anomalous scaling. Fractional diffusion models are proposed and tested in the quantitative description of the non-diffusive Lagrangian statistics of the fluid and plasma problems. Also, fractional diffusion operators are used to construct non-local transport models exhibiting up-hill transport, multivalued flux-gradient relations, fast pulse propagation phenomena, and tunneling of perturbations across transport barriers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overestimated prediction using polygenic prediction derived from summary statistics

When polygenic risk score (PRS) is derived from summary statistics, independence between discovery and test sets cannot be monitored. We compared two types of PRS studies derived from raw genetic data (denoted as rPRS) and the summary statistics for IGAP (sPRS). Two variables with the high heritability in UK Biobank, hypertension, and height, are used to derive an exemplary scale effect of PRS. sPRS without APOE is derived from International Genomics of Alzheimer’s Project (IGAP), which records ΔAUC and ΔR 2 of 0.051 ± 0.013 and 0.063 ± 0.015 for Alzheimer’s Disease Sequencing Project (ADSP) and 0.060 and 0.086 for Accelerating Medicine Partnership - Alzheimer’s Disease (AMP-AD). On UK Biobank, rPRS performances for hypertension assuming a similar size of discovery and test sets are 0.0036 ± 0.0027 (ΔAUC) and 0.0032 ± 0.0028 (ΔR 2 ). For height, ΔR 2 is 0.029 ± 0.0037. Considering the high heritability of hypertension and height of UK Biobank and sample size of UK Biobank, sPRS results from AD databases are inflated. Independence between discovery and test sets is a well-known basic requirement for PRS studies. However, a lot of PRS studies cannot follow such requirements because of impossible direct comparisons when using summary statistics. Thus, for sPRS, potential duplications should be carefully considered within the same ethnic group.

97 MATHEMATICS AND COMPUTING↗

Convergent Concordant Mode Approach for Molecular Vibrations: CMA-2

The concordant mode approach (CMA) is a promising new scheme for dramatically increasing the system size and level of theory achievable in quantum chemical computations of molecular vibrational frequencies. Here, we achieve advances in the CMA hierarchy by computations targeting CCSD(T)/cc-pVTZ (coupled cluster singles and doubles with perturbative triples using a correlation-consistent polarized-valence triple-ζ basis set) benchmarks within the G2 molecular test set, executing a statistical analysis for 1501 frequencies from 111 compounds and then separately solving the refractory case of pyridine. First, MP2/cc-pVTZ (second-order Møller–Plesset perturbation theory with the same basis set) proves to be an excellent and preferred choice for generating the underlying (Level B) normal modes of the CMA scheme. Utilizing this Level B within the CMA-0A method reproduces the 1501 benchmark frequencies with a mean absolute error (MAE) of only 0.11 cm –1 and an attendant standard deviation of 0.49 cm –1 . Second, a convergent CMA-2 method is constituted that allows efficient computation of higher level (Level A) frequencies to any reasonable accuracy threshold by using only Hartree–Fock (HF) and MP2 or density functional theory (DFT) data to generate ξ parameters, which select the sparse off-diagonal force field elements for explicit evaluation at Level A. When Level B = MP2/cc-pVTZ, a cutoff of ξ = 0.02 provides an average maximum absolute error per molecule of only 0.17 cm –1 by incurring merely a 33% increase in average cost over CMA-0A. This CMA-2 method also eradicates the 4 problematic CMA-0A outliers of pyridine with even less effort (ξ = 0.04, 22% increase). Finally, the newly developed CMA procedures are shown to be highly successful when applied to 1-(1H-pyrrol-3-yl)ethanol, a new test molecule with diverse types of vibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Composite Overwrapped Pressure Vessels (COPV): Flight Rationale for the Space Shuttle Program

Each Orbiter Vehicle (Space Shuttle Program) contains up to 24 Kevlar49/Epoxy Composite Overwrapped Pressure Vessels (COPV) for storage of pressurized gases. In the wake of the Columbia accident and the ensuing Return To Flight (RTF) activities, Orbiter engineers reexamined COPV flight certification. The original COPV design calculations were updated to include recently declassified Kevlar COPV test data from Lawrence Livermore National Laboratory (LLNL) and to incorporate changes in how the Space Shuttle was operated as opposed to orinigially envisioned. 2005 estimates for the probability of a catastrophic failure over the life of the program (from STS-1 through STS-107) were one-in-five. To address this unacceptable risk, the Orbiter Project Office (OPO) initiated a comprehensive investigation to understand and mitigate this risk. First, the team considered and eventually deemed unfeasible procuring and replacing all existing flight COPVs. OPO replaced the two vessels with the highest risk with existing flight spare units. Second, OPO instituted operational improvements in ground procedures to signficiantly reduce risk, without adversely affecting Shuttle capability. Third, OPO developed a comprehensive model to quantify the likelihood of occurrance. A fully-instrumented burst test (recording a lower burst pressure than expected) on a flight-certified vessel provided critical understanding of the behavior of Orbiter COPVs. A more accurate model was based on a newly-compiled comprehensive database of Kevlar data from LLNL and elsewhere. Considering hardware changes, operational improvements and reliability model refinements, the mean reliability was determined to be 0.998 for the remainder of the Shuttle Program (from 2007, for STS- 118 thru STS-135). Since limited hardware resources precluded full model validation through multiple tests, additional model confidence was sought through the first-ever Accelerated Stress Rupture Test (ASRT) of a flown flight article. A Bayesian statistical approach was developed to interpret possible test results. Since the lifetime observed in the ASRT exceeded initial estimates by one to two orders of magnitude, the Space Shuttle Program deemed there was significant conservatism in the model and accepted continued operation with existing flight hardware. Given the variability in tank-to-tank original prooftest response, a non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure COPV residual stress state. Preliminary results showed that patterns of low fiber elastic strains over the outside vessel surface, together with measured permanent volume growth during proof, could be directly correlated to increased fiber stress ratios on the inside fibers adjacent to the liner, and thus reduced reliability.

Kezirian, Michael T.↗

Feasibility of Correlation-Aware Inference and Universal Precision Scaling in Bonse–Hart Ultra-Small-Angle Neutron Scattering

Bonse–Hart ultra-small-angle neutron scattering (USANS) provides access to micrometre-scale structure, but useful measurements often require long counting times. In this work, we test whether the expected smoothness of the scattering profile can be exploited to improve data quality at lower counting statistics. We apply a Gaussian-process-based method to Bonse–Hart USANS data and evaluate its performance on pseudo-measurements generated from high-statistics experiments under Poisson statistics. This provides a stringent test of how well the underlying I(Q) profile can be reconstructed when the available counts are substantially reduced. We further show that, in the counting-limited regime, the reconstruction error follows a universal scaling behaviour that differs from the usual independent-counting expectation. At higher counts, the improvement crosses over to a resolution-limited regime set by analyser-angle discretization and rocking-curve width. These results clarify when correlation-aware inference is useful in USANS and provide a practical basis for improving measurement efficiency and beam-time usage.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Does Size Really Matter? Analysis of the Effect of Large Fibroids and Uterine Volumes on Complication Rates of Uterine Artery Embolisation

The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diameter of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Analysis of Model Data for Operational Space Launch Weather Support at Kennedy Space Center and Cape Canaveral Air Force Station

The 12-km resolution North American Mesoscale (NAM) model (MesoNAM) is used by the 45th Weather Squadron (45 WS) Launch Weather Officers at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to support space launch weather operations. The 45 WS tasked the Applied Meteorology Unit to conduct an objective statistics-based analysis of MesoNAM output compared to wind tower mesonet observations and then develop a an operational tool to display the results. The National Centers for Environmental Prediction began running the current version of the MesoNAM in mid-August 2006. The period of record for the dataset was 1 September 2006 - 31 January 2010. The AMU evaluated MesoNAM hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The MesoNAM forecast winds, temperature and dew point were compared to the observed values of these parameters from the sensors in the KSC/CCAFS wind tower network. The data sets were stratified by model initialization time, month and onshore/offshore flow for each wind tower. Statistics computed included bias (mean difference), standard deviation of the bias, root mean square error (RMSE) and a hypothesis test for bias = O. Twelve wind towers located in close proximity to key launch complexes were used for the statistical analysis with the sensors on the towers positioned at varying heights to include 6 ft, 30 ft, 54 ft, 60 ft, 90 ft, 162 ft, 204 ft and 230 ft depending on the launch vehicle and associated weather launch commit criteria being evaluated. These twelve wind towers support activities for the Space Shuttle (launch and landing), Delta IV, Atlas V and Falcon 9 launch vehicles. For all twelve towers, the results indicate a diurnal signal in the bias of temperature (T) and weaker but discernable diurnal signal in the bias of dewpoint temperature (T(sub d)) in the MesoNAM forecasts. Also, the standard deviation of the bias and RMSE of T, T(sub d), wind speed and wind direction indicated the model error increased with the forecast period all four parameters. The hypothesis testing uses statistics to determine the probability that a given hypothesis is true. The goal of using the hypothesis test was to determine if the model bias of any of the parameters assessed throughout the model forecast period was statistically zero. For th is dataset, if this test produced a value >= -1 .96 or <= 1.96 for a data point, then the bias at that point was effectively zero and the model forecast for that point was considered to have no error. A graphical user interface (GUI) was developed so the 45 WS would have an operational tool at their disposal that would be easy to navigate among the multiple stratifications of information to include tower locations, month, model initialization times, sensor heights and onshore/offshore flow. The AMU developed the GUI using HyperText Markup Language (HTML) so the tool could be used in most popular web browsers with computers running different operating systems such as Microsoft Windows and Linux.

Bauman, William H., III↗

Nonparametric algorithms for the search of signals

Two algorithms for the search of signals in noise are constructed. Two independent measurable properties of a discreet time-dependent stochastic process F are described. The functions A sub K and B sub K fully satisfy conditions for the application of a test based on Spearman's rank correlation coefficient. A statistic to which the one-sided signal test can be applied is constructed under sufficiently natural assumptions about the noise process. The constructed statistics are simplified. Processing results from calculations of statistics constructed for concrete processes are presented.

Myshenkova, T. S.↗

Automated Data Collection for Determining Statistical Distributions of Module Power Undergoing Potential-Induced Degradation: Preprint

We propose a method for increasing the frequency of data collection and reducing the time and cost of accelerated lifetime testing of photovoltaic modules undergoing potential-induced degradation (PID). This consists of in-situ measurements of dark current-voltage curves of the modules at elevated stress temperature, their use to determine the maximum power at 25 degrees C standard test conditions (STC), and distribution statistics for determining degradation rates as a function of stress level. The semi-continuous data obtained by this method clearly show degradation curves of the maximum power, including an incubation phase, rates and extent of degradation, precise time to failure, and partial recovery. Stress tests were performed on crystalline silicon modules at 85% relative humidity and 60 degrees C, 72 degrees C, and 85 degrees C. Activation energy for the mean time to failure (1% relative) of 0.85 eV was determined and a mean time to failure of 8,000 h at 25 degrees C and 85% relative humidity is predicted. No clear trend in maximum degradation as a function of stress temperature was observed.

14 SOLAR ENERGY↗

Variability of Gross Tumor Volume Delineation in Head-and-Neck Cancer Using PET/CT Fusion, Part II: The Impact of a Contouring Protocol

The purpose of this study was to assess the efficacy of a gross tumor volume (GTV) contouring protocol on interobserver variability between 4 physicians in positron emission therapy/computed tomography (PET/CT) treatment planning of head-and-neck cancer. A GTV contouring protocol for PET/CT treatment planning was developed utilizing 4 stages: Preliminary contouring on CT alone, determination of appropriate PET windowing, accurate image registration, and modification of CT contouring with correctly formatted PET/CT display and rules for modality disagreement. Two neuroradiologists and 2 radiation oncologists (designated as A, B, C, and D, respectively) were given a tutorial of PET/CT coregistered imaging individualized to their skill level, which included a step-by-step explanation of the protocol with clinical examples. Opportunities for questions and hands-on practice were given. The physicians were asked to re-contour 16 head-and-neck patients from Part I on PET/CT fusion imaging. Differences in volume magnitude were analyzed for statistical significance by analysis of variance (ANOVA) and paired t-tests ({alpha} < 0.05). Volume overlap was analyzed for statistical significance using Wilcoxon signed-rank tests ({alpha} < 0.05). Volume overlap increased significantly from Part I to Part II (p < 0.05). One previously significant difference between physicians disappeared with the protocol in place. The mean fusion volume of Physician C, however, remained significantly larger than that of Physician D (p < 0.01). This result is unchanged from Part I. The multidisciplinary contouring protocol significantly improved the coincidence of GTVs contoured by multiple physicians. The magnitudes of the volumes showed marginal improvement in consistency. Developing an institutional contouring protocol for PET/CT treatment planning is highly recommended to reduce interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target Detection via Cognitive Radars Using Change-Point Detection, Learning, and Adaptation

Many radar detection algorithms that assume a stationary environment (clutter) have been proposed and analyzed over the years. However, in practice, changes in the nonstationary environment can perturb the parameters of the clutter distribution, or even alter the clutter distribution family, which can greatly deteriorate the target detection capability. To avoid such potential performance degradation, cognitive radar systems are envisioned which are required to rapidly realize the nonstationarity, accurately learn the new characteristics of the environments, and adaptively update the detector. In this paper, aiming to develop a fully cognitive radar for target detection in nonstationary environments, we propose a unifying framework that integrates (i) change-point detection of clutter distributions by using a data-driven cumulative sum (CUSUM) algorithm and its extended version, (ii) learning/identification of clutter distribution by applying sparse theory and kernel density estimation methods, and (iii) adaptive target detection by automatically modifying the likelihood-ratio test and corresponding detection threshold. Further, with extensive numerical examples, we demonstrate the achieved improvements in detection performance due to the proposed framework in comparison to a nonadaptive case, an adaptive matched filter (AMF) method, and the clairvoyant case. Herein, we also use Wilcoxon rank-sum tests to evaluate the statistical significance of the performance improvements

42 ENGINEERING↗

Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?

Purpose: To determine if texture analysis can differentiate placenta accreta spectrum (PAS) from normal placenta on MRI. Methods: We performed retrospective image analysis of 80 patients, comprised of 46 patients with PAS and 34 patients without PAS. Histopathology was used as the reference standard. Sagittal single shot fast spin echo T2-weighted MRI sequences acquired from a single institution were analyzed. Placental heterogeneity was quantified using in-house software on a Matlab platform, including the standard deviation of pixel intensity, coefficient of variation, gray-level co-occurrence matrices (GLCM), histogram-oriented gradients (HOG), and fractal analysis with box sizes from 2 to 512. Two-tailed unpaired Student’s t test was used with statistical significance of p < 0.05. Results: PAS was associated with higher values for standard deviation of pixel intensity and fractal analysis at every box size. Fractal analysis at box sizes 256 (p = 0.011) and 32 (p = 0.021), and standard deviation of pixel intensity (p = 0.023) were the most statistically significant. Fractal values at box size 256 for PAS was 0.13 versus 0.090 for patients without PAS, while standard deviation of pixel intensity was 3.7 for PAS versus 2.5 for patients without PAS. No statistically significant association between PAS and GLCM, coefficient of variation, and HOG was found. Conclusion: Statistically significant differences were found between normal and abnormal groups using standard deviation of pixel intensity and fractal analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both groups). The incidence of pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7 patients: 13.7 %), from which one patient developed a persistent air leakage necessitating pleurodesis.ConclusionPneumothorax complicating CT-guided core biopsy of pulmonary lesions, showed the insignificant difference between coaxial and non-coaxial techniques. However, both techniques have the same significant risk factors including small and basal lesions, increased lesion’s depth from pleural surface, and increased length of aerated lung parenchyma crossed by biopsy needle and passing through pulmonary fissures in the needle tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of NMME temperature and precipitation bias and forecast skill for South Asia

Systematic error and forecast skill for temperature and precipitation in two regions of Southern Asia are investigated using hindcasts initialized May 1 from the North American Multi-Model Ensemble. We focus on two contiguous but geographically and dynamically diverse regions: the Extended Indian Monsoon Rainfall (70–100E, 10–30 N) and the nearby mountainous area of Pakistan and Afghanistan (60–75E, 23–39 N). Forecast skill is assessed using the Sign test framework, a rigorous statistical method that can be applied to non-Gaussian variables such as precipitation and to different ensemble sizes without introducing bias. We find that models show significant systematic error in both precipitation and temperature for both regions. The multi-model ensemble mean (MMEM) consistently yields the lowest systematic error and the highest forecast skill for both regions and variables. However, we also find that the MMEM consistently provides a statistically significant increase in skill over climatology only in the first month of the forecast. While the MMEM tends to provide higher overall skill than climatology later in the forecast, the differences are not significant at the 95% level. We also find that MMEMs constructed with a relatively small number of ensemble members per model can equal or outperform MMEMs constructed with more members in skill. This suggests some ensemble members either provide no contribution to overall skill or even detract from it.

54 ENVIRONMENTAL SCIENCES↗