Design of dehumidification test of HTR-PM - 18461
Moisture in the primary loop is harmful for the normal operation of the Modular High Temperature Gas-cooled Reactor (MHTGR). A dehumidification test to remove the moisture in the primary loop of the High Temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) reactor was proposed. This test consisted of two stages, stage A and stage B. The test process of stage A was divided into six steps including vacuuming, inflating, heating, dehumidifying, cooling and venting, while the test process of stage B only included the first five steps of stage A. Nitrogen and helium were respectively used as the dehumidification gas to carry away the moisture in the graphite in stage A and stage B, which were circulated and heated by the helium blower. What s more, preliminary calculations to heating and dehumidifying were implemented. Variations of water content of the graphite in the dehumidification process were obtained, and the times spent for different dehumidification targets were also worked out. It needs 19.5 days to remove 80% of the moisture in the graphite in stage A when the dehumidification temperature is 150 deg. C, and 14.3 days are needed to make water content in the graphite decrease from 20% to 5% in stage B. The results show that the test method proposed is feasible and effective, and offer references to the design, test and operation of the HTR-PM. (authors)