Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Single-Axis Accelerometer

A single-axis accelerometer includes a housing defining a sleeve. An object/mass is disposed in the sleeve for sliding movement therein in a direction aligned with the sleeve's longitudinal axis. A first piezoelectric strip, attached to a first side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The first piezoelectric strip includes a first strip of a piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A second piezoelectric strip, attached to a second side of the object and to the housing, is longitudinally aligned with the sleeve's longitudinal axis. The second piezoelectric strip includes a second strip of the piezoelectric material with carbon nanotubes substantially aligned along a length thereof. A voltage sensor is electrically coupled to at least one of the first and second piezoelectric strips.

Tucker, Dennis Stephen↗

Caustic-Side Solvent Extraction Full-Scale Test

A Full-Scale Test (FST) program was performed by Parsons and its team members General Atomics and Energy Solutions to assess the performance of full-scale centrifugal contactors specified for the Department of Energy Salt Waste Processing Facility (SWPF). The SWPF, to be located at the Savannah River Site (SRS) in Aiken, South Carolina, will remove highly radioactive waste constituents, principally actinides, strontium (Sr), and cesium (Cs) radionuclides, from salt waste solutions currently stored in SRS high-level waste tanks. Caustic-side Solvent Extraction (CSSX) removes Cs from waste feed that has been treated upstream to remove actinides and Sr. CSSX uses a custom solvent to extract Cs from the salt solution in a series of single stage centrifugal contactors. The test system comprised (a) eleven 25.4 cm (10'') full-scale contactors (versus 36 in SWPF) for the extraction, scrub, strip, and wash stages; (b) two solvent recovery coalescers; and (c) the associated hardware and control system, packaged in four skid mounted modules. This paper describes the results of tests performed to define both hydraulic performance parameters (maximum hydraulic capacity and phase carryover) and solvent extraction performance parameters (Cs mass transfer efficiencies) using simulated SWPF waste and actual CSSX solvent. The test results confirmed key design features of the CSSX process and, as a consequence, the use of CSSX in the SWPF. In conclusion: Total throughput was initially limited to 85% of maximum flow during FST. Minor system modifications performed prior to mass transfer testing series resulted in the realization of 100% throughput. The 100% flow equates to slightly more than 35.6 x 10{sup 6} L/yr (9.4 Mgal/yr) of waste processed in SWPF which is anticipated to be the peak plant throughput. To achieve the best hydraulic performance in extraction, it is recommended that the extraction contactors be operated at the highest reasonable speed possible (>2100 rpm). Vibration, hardware limitations, bearing life, and other factors should be considered prior to final selection of extraction contactor speeds in SWPF. In strip (also scrub and wash) aqueous carryover decreased and organic carryover increased as the rotor speeds increased. It is recommended that the strip, scrub, and wash contactors be operated at intermediate speeds (between 1500 and 2100 rpm) to achieve a performance compromise between aqueous and organic carryover. Curved-vane bottom plates showed a significant hydraulic performance (aqueous and organic carryover) advantage over straight-vane bottom plates in extraction. There was no significant mass transfer performance advantage for either plate type in extraction. Thus, curved-vane bottom plates in extraction may be the better option for use in SWPF. There was no significant hydraulic performance difference between the plate types in strip. Straight-vanes provided significantly better mass transfer performance in strip compared to curved-vanes. Based solely on mass transfer performance, straight-vane bottom plates in the strip, scrub, and wash contactors are recommended for use in SWPF. Utilizing straight-vanes in the stripping section, the overall SWPF CSSX performance is expected to meet or exceed the target DF of 40,000 with minimum extraction D{sub Cs} of 10. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical and Mechanical Analysis of HDIS Residues using Auger Electron Spectroscopy and Nanoindentation

Photoresist stripping after ion implantation at high dosages (>1E15 atoms/cm2) is the most challenging dry strip process for advanced logic devices. Such high-dose implant stripping (HDIS) frequently leaves residues on the wafers after dry strip, unless fluorine chemistries are employed in the stripping plasma. Silicon loss requirements at sub-45nm nodes generally preclude such aggressive stripping chemistries. Instead, a wet clean is used to remove residues. However, the nature of the residues is not well understood, and are believed to usually contain some of the cross-linked, carbonized organic polymer formed in the implant [1]. In this paper we present chemical and mechanical data on HDIS residues produced from oxidizing and reducing chemistry strip processes

36 MATERIALS SCIENCE↗

A look into the voltage plateau signal for detection and quantification of lithium plating in lithium-ion cells

Voltage plateau during relaxation or discharge after charging is a distinct signal associated with stripping of deposited Li metal and hence a feasible tool for online detection of Li plating in Li-ion batteries. In this report we present a physics-based model with incorporation of Li plating and stripping to gain a fundamental understanding of the voltage plateau behavior. Specifically, we focus on the internal cell characteristics when voltage plateau occurs and on key factors affecting the shape and duration of voltage plateau. Furthermore, the validity of using the duration of voltage plateau for estimating Li plating amount is assessed. It is found that the duration of voltage plateau depends on the rate of Li stripping, while the stripping rate is restricted by the capability of Li+ intercalation into graphite. Parameters like intercalation kinetics, solid-state diffusivity of graphite and cell temperature can substantially influence the voltage curves even with the same amount of Li plating. Further, we report an interesting phenomenon that during Li stripping one part of anode near the separator has net oxidation current (local stripping rate > intercalation rate), providing Li+ ions and electrons to the other part of anode near the foil which has net reduction current.

25 ENERGY STORAGE↗

Residue detection for real-time removal of paint from metallic surfaces

Paint stripping from large steel ships and other metallic surfaces is a major issue in the maintenance and refurbishing of structures, and environmental concerns are greatly limiting the possible options. As a result, waterjet with water recycling has become the leading form of paint stripping and robotic manipulators with scanning bridges were constructed by various manufacturers to address this need. The application of such scanning bridges is slow and their access is constrained by the complex shape of the ship hull and various features on the surface. To overcome these limitations, a robotic system that is called Ultrastrip (UltraStrip Systems, Inc., Stuart, FL) is developed. This system uses magnetic wheels to attach the stripper to the structure and travel on it while performing paint stripping. To assure efficient paint stripping feedback data is required to control the travel speed by monitoring the paint thickness before and during the stripping process. Efforts at JPL are currently underway to develop the required feedback capability to assure effective paint stripping. Various possible sensors were considered and issues that can affect the sensitivity, reliability and applicability of the sensors are being investigated with emphasis on measuring the initial conditions of the paint. Issues that affect the sensory data in dynamic conditions are addressed while providing real-time real feedback for the control of the paint stripper speed of travel.

NDT↗

Study on separation of minor actinides from HLLW with new extractant of TODGA-DHOA/Kerosene

The extraction behavior of U, Np, Pu, Am, rare earth elements and Sr from nitric acid solutions by TODGA/dodecan, DHOA/dodecane and TODGA-DHOA/dodecane were investigated, respectively. Based on experimental results, a separation process was proposed for minor actinide isolation from high level liquid waste (HLLW): the TODGA-DHOA/kerosene system. The multi-stage counter-current cascade experiments were carried out for the purpose by 0.1 mol/l TODGA-1.0 mol/l DHOA/kerosene with miniature mixer- settler contactor rigs (8 stages for extraction, 6 stages for scrubbing, 8 stages for first stripping, 8 stages for second stripping). The results show that the recovery efficiencies of the actinides and lanthanides are more than 99.9%, whereas less than 1% Sr was extracted by 0.1 mol/l TODGA - 1.0 mol/l DHOA/kerosene. The stripping efficiencies of U, Np and Pu are more than 95% in the first stripping step by 0.5 mol/l HNO{sub 3} + 0.5 mol/l AHA(aceto-hydroxamic acid), all of the remained actinides and lanthanides can be stripped by 0.01 mol/l HNO{sub 3} in the second stripping step. 99% Sr was extracted by 0.1 mol/l TODGA/kerosene, so Sr can be recovered efficiently directly from the raffinate by 0.1 mol/l TODGA/kerosene. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization, Mechanism and Control Measures of V Segregation in Continuous Casting Billet of C-Mn Steel

To eliminate V segregation, which significantly deteriorates the homogeneity of continuous casting steel billets, V segregation in the C-Mn steel billet was observed by microscope, SEM and EDS. The formation mechanism and control measures for V segregation were proposed. Results show that many slim V segregation strips are distributed on an inverted conical surface and that most segregation strips start from the vertex of the inverted conical surface. A series of inverted conical surfaces containing V segregation strips periodically appears along the longitudinal direction of the billet. The microstructures in the V segregation strip are fine granular structures, while the microstructures outside the V segregation strip are coarse Widmanstätten. The V segregation strip also contains many inclusions and porosities. The formation mechanism for V segregation, which is illuminated by a physical simulation of Al-5wt pctCu alloy, is attributed to the fissure in the equiaxed dendritic network torn by solidification contraction. By controlling the percentage and distribution of equiaxed grains, the V segregation in the billet of C-Mn steel is completely eliminated.

36 MATERIALS SCIENCE↗

Extraction of lithium from battery recycling wastewater using synergistic D2EHPA and TBP

The recycling of spent lithium-ion batteries (LIBs) poses significant challenges, including the generation of large volumes of chemically complex wastewater. The composition of this wastewater is influenced by both the intrinsic chemistry of the batteries and the specific recycling processes employed. Notably, this wastewater contains economically valuable components, such as lithium, which can be recovered. Here, in this study, a solvent extraction (SX) process was investigated as a method to recover lithium from battery recycling wastewater, especially from anode-washing stage. Initially, various commercial extractants were evaluated, including di(2-ethylhexyl)phosphoric acid (D2EHPA), mono-2-ethylhexyl (2-ethylhexyl)phosphonate (PC88A), bis(2,4,4-trimethylpentyl)phosphinic acid (Cyanex 272), 2-hydroxy-5-nonylacetophenone oxime (LIX 84-I), tri-butyl phosphate (TBP), and their combinations. Among these, D2EHPA + TBP demonstrated a synergism to advance and maximize the lithium extraction. Subsequently, the effects of key parameters, including D2EHPA concentration, TBP concentration, contact time, initial pH, and aqueous-to-organic (A/O) phase ratio, were systematically investigated and optimized. A two-stage SX approach was employed to enhance lithium recovery. Under the optimized conditions of 30.0 vol% D2EHPA, 10.0 vol% TBP, 10 min of contact time, and a 1:1 A/O phase ratio, a lithium extraction efficiency of more than 88% in a two-stage solvent extraction was achieved. Lithium was subsequently stripped from the loaded organic solution using sulfuric acid (H 2 SO 4 ). Using 2.0 M H 2 SO 4 , lithium stripping was achieved after two counter-current stripping stages at an organic-to-aqueous (O/A) phase ratio of 6:1. This stripping process enriched the lithium concentration by a factor of four compared to the original lithium concentration in the anode-washing wastewater. The recyclability of the synergistic D2EHPA + TBP system was also evaluated over four extraction-stripping cycles. The results demonstrated that the system maintained high extraction and stripping efficiencies.

D2EHPA↗

HRTEM and neutron diffraction study of Li{sub x}Mo{sub 5}O{sub 17}: From the ribbon (x=5) structure to the rock salt (x=12) structure

Structure determination of the fully intercalated phase Li{sub 12}Mo{sub 5}O{sub 17} and of the deintercalated oxide Li{sub 5}Mo{sub 5}O{sub 17} has been carried out by electron microscopy and neutron powder diffraction. The reversible topotactic transformation between the ordered rock salt structure of the former and the ribbon structure of the latter (closely related to that of Li{sub 4}Mo{sub 5}O{sub 17}) is explained on the following basis: both structures can be described as strips built up as an assembly of infinite ribbons of MoO{sub 6} octahedra that are five octahedra thick, and that differ by slight displacements of the octahedral ribbons. We show that the electrochemical behavior of the Li{sub x}Mo{sub 5}O{sub 17} system is based on two sorts of Li{sup +} sites; those that are located within the strips between the ribbons, and those that are located at the border of the strips. The high rate of Li intercalation in this oxide and its reversibility are discussed in terms of its peculiar structure. -- Graphical abstract: Structure determination of the fully intercalated phase Li{sub 12}Mo{sub 5}O{sub 17} and of the deintercalated oxide Li{sub 5}Mo{sub 5}O{sub 17} has been carried out by electron microscopy and neutron powder diffraction. The reversible topotactic transformation between the ordered rock salt structure of the former and the ribbon structure of the latter is explained on the following basis: both structures can be described as strips built up as an assembly of infinite ribbons of MoO{sub 6} octahedra that are five octahedra thick, and that differ by slight displacements of the octahedral ribbons. We show that the electrochemical behavior of the Li{sub x}Mo{sub 5}O{sub 17} system is based on two sorts of Li{sup +} sites; those that are located within the strips between the ribbons, and those that are located at the border of the strips. The high rate of Li intercalation in this oxide and its reversibility are discussed in terms of its peculiar structure. Research highlights: {yields} Electron microscopy and neutron powder diffraction structure determination {yields} We have explained the reversible topotactic transformation between an ordered rock salt structure and a ribbon structure {yields} We show that the electrochemical behavior of the Li{sub x}Mo{sub 5}O{sub 17} system is based on two sorts of Li{sup +} sites {yields} The high rate of Li intercalation in this oxide and its reversibility are discussed in terms of its peculiar structure.

36 MATERIALS SCIENCE↗

Production and cross-sectional characterization of aligned co-electrospun hollow microfibrous bulk assemblies

The development of co-electrospun (co-ES) hollow microfibrous assemblies of an appreciable thickness is critical for many practical applications, including filtration membranes and tissue-mimicking scaffolds. In this study, thick uniaxially aligned hollow microfibrous assemblies forming fiber bundles and strips were prepared by co-ES of polycaprolactone (PCL) and polyethylene oxide (PEO) as shell and core materials, respectively. Hollow microfiber bundles were deposited on a fixed rotating disc, which resulted in non-controllable cross-sectional shapes on a macroscopic scale. In comparison, fiber strips were produced with tuneable thickness and width by additionally employing an x–y translation stage in co-ES. Scanning electron microscopy (SEM) images of cross-sections of fiber assemblies were analyzed to investigate the effects of production time (from 0.5 h to 12 h), core flow rate (from 0.8 mL/h to 2.0 mL/h) and/or translation speed (from 0.2 mm/s to 5 mm/s) on the pores and porosity. We observed significant changes in pore size and shape with core flow rate but the influence of production time varied; five strips produced under the same conditions had reasonably good size and porosity reproducibility; pore sizes didn't vary significantly from strip bottom to surface, although the porosity gradually decreased and then returned to the initial level. - Highlights: • Hollow microfibrous assemblies based on co-electrospinning are demonstrated. • The thickness and width of co-electrospun strips were controllable. • Cross-sections of fibres had non-normally distributed pore sizes and shapes. • Cross-sections were significantly influenced by production time and flow rate. • Co-electrospun strips had reasonably good reproducible cross-sections.

36 MATERIALS SCIENCE↗

Masked-backlighter technique used to simultaneously image x-ray absorption and x-ray emission from an inertial confinement fusion plasma

A method to simultaneously image both the absorption and the self-emission of an imploding inertial confinement fusion plasma has been demonstrated on the OMEGA Laser System. The technique involves the use of a high-Z backlighter, half of which is covered with a low-Z material, and a high-speed x-ray framing camera aligned to capture images backlit by this masked backlighter. Two strips of the four-strip framing camera record images backlit by the high-Z portion of the backlighter, while the other two strips record images aligned with the low-Z portion of the backlighter. The emission from the low-Z material is effectively eliminated by a high-Z filter positioned in front of the framing camera, limiting the detected backlighter emission to that of the principal emission line of the high-Z material. As a result, half of the images are of self-emission from the plasma and the other half are of self-emission plus the backlighter. The advantage of this technique is that the self-emission simultaneous with backlighter absorption is independently measured from a nearby direction. The absorption occurs only in the high-Z backlit frames and is either spatially separated from the emission or the self-emission is suppressed by filtering, or by using a backlighter much brighter than the self-emission, or by subtraction. The masked-backlighter technique has been used on the OMEGA Laser System to simultaneously measure the emission profiles and the absorption profiles of polar-driven implosions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design for large-area fast photo-detectors with transmission-line readout and waveform sampling.

We present a preliminary design and the results of simulation for a photo-detector module to be used in applications requiring the coverage of areas of many square meters with time resolutions less than 10 picoseconds and position resolutions of less than a millimeter for charged particles. The source of light is Cherenkov light in a radiator/window; the amplification is provided by panels of micro-pores functionalized to act as microchannel plates (MCPs). The good time and position resolution stems from the use of an array of parallel 50 Omega transmission lines (strips) as the collecting anodes. The anode strips feed multi-GS/sec sampling chips which digitize the pulse waveform at each end of the strip, allowing a measurement of the time from the average of the two ends, and a 2-dimensional position measurement from the difference of times on a strip, and, in the orthogonal direction, the strip number, or a centroid of the charges deposited on adjacent strips. The module design is constructed so that large areas can be 'tiled' by an array of modules.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermomechanical Design Optimization of Roll-to-Roll Manufactured Hybrid Metal Polymer Heat Exchanger

Metal based heat exchangers for ultra-low temperature (<100C) waste heat recovery (WHR) face high maintenance and material costs that surpass profits from recovery[1]. Low-cost polymer pipes suffer from poor thermal conductivity (~0.2 W/mK), and thus a low overall heat transfer coefficient. Thermal conductivity of polymers can be enhanced through systematic molecular alignment by stretching[2], chemical vapor deposition of extended polymers [3], surface grating [4], etc. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [3], and thermomechanical considerations [5]. In this work, we propose novel hybrid metal-polymer strips that are strategically designed to enhance thermal conductivity by cladding copper around polymer strips. The polymer strips with copper-clad edges are wound helically to form the pipes for a heat exchanger. Through finite element simulations, we optimize the design for enhanced thermal performance of the polymer-metal strips. We predict up to 20 % enhancement in overall heat transfer from a base polymer with a thermal conductivity of 0.2 W/mK. We show that the thermomechanical strains induced in the pipes can be reduced to < 0.2 % by strategically stacking and welding multiple polymer-metal strips. We verified the improved thermal performance of the roll-to-roll manufactured strips through a thermal conductivity measurement setup. The optimized design of hybrid metal-polymer pipes provides a scalable and cost-effective means for harvesting waste heat from ultra-low temperature sources. Thekdi, Arvind, and Sachin U. Nimbalkar. Oak Ridge National Lab, 2015 Shen, Sheng, et al. Nature nanotechnology 5.4 (2010): 251. Xu, Yanfei, et al. Science advances 4.3 (2018): 3031. Smith, M. K., Singh, V., Kalaitzidou, K., & Cola, B. A. (2015). ACS nano, 9(2), 1080-1088. Aymonier, C., Bortzmeyer, D., Thomann, R., & Mülhaupt, R. (2003). Chemistry of Materials, 15(25), 4874-4878.

C Rajagopal, Manjunath↗

Thermomechanical design optimization for low metal footprint in hybrid metal-polymer heat exchanger

Material and maintenance costs of metal-based heat exchangers surpass profits in waste heat recovery (WHR) from ultra-low temperature (<100C) sources [1]. A low-cost alternative like polymer pipes suffer from poor thermal conductivity (~0.2 W/mK), and a low overall heat transfer coefficient. Polymers’ thermal conductivity have previously been enhanced through systematic molecular alignment by stretching [2], chemical vapor deposition of extended polymers [3], surface grating [4], etc. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [3], and thermomechanical considerations [5]. In this work, we propose novel hybrid metal-polymer heat exchangers that are made from polymer-copper strips. Through finite element method (FEM) simulations, we first optimize the placement of copper around polymer strips to enhance the transverse thermal conductivity of the strips. The copper cladded polymer strips are wound helically in a roll-to-roll system to form the pipes for a heat exchanger. We then optimize the design of helically wound pipes to reduce thermomechanical strains to < 0.2 % at 100C and 40 psi working conditions. At 25 % volume fraction of copper in the pipe, we predict up to 20 % enhancement in overall heat transfer from a base polymer with a thermal conductivity of 0.2 W/mK. We also compare and contrast the thermomechanical performance of the optimized metal-polymer strips to random metal matrix composites. Finally, we experimentally verify the thermal conductivity of the optimized strips through bulk thermal conductivity and thermal interface resistance measurement setup. By systematically improving the design through FEM and experimental measurements, we provide an optimized design of hybrid metal-polymer pipes that provides a low metal footprint and cost-effective means for harvesting waste heat from ultra-low temperature sources. Thekdi, Arvind, and Sachin U. Nimbalkar. Oak Ridge National Lab, 2015 Shen, Sheng, et al. Nature nanotechnology 5.4 (2010): 251. Xu, Yanfei, et al. Science advances 4.3 (2018): 3031. Smith, M. K., Singh, V., Kalaitzidou, K., & Cola, B. A. (2015). ACS nano, 9(2), 1080-1088. Aymonier, C., Bortzmeyer, D., Thomann, R., & M&uuml;lhaupt, R. (2003). Chemistry of Materials, 15(25), 4874-4878.

C Rajagopal, Manjunath↗

Inviscid, nonadiabatic flow fields over blunt, sonic corner bodies for outer planet entry conditions by a method of integral relations

An investigation has been made into the ability of a method of integral relations to calculate inviscid zero degree angle of attack, radiative heating distributions over blunt, sonic corner bodies for some representative outer planet entry conditions is investigated. Comparisons have been made with a more detailed numerical method, a time asymptotic technique, using the same equilibrium chemistry and radiation transport subroutines. An effort to produce a second order approximation (two-strip) method of integral relations code to aid in this investigation is also described and a modified two-strip routine is presented. Results indicate that the one-strip method of integral relations cannot be used to obtain accurate estimates of the radiative heating distribution because of its inability to resolve thermal gradients near the wall. The two-strip method can sometimes be used to improve these estimates; however, the two-strip method has only a small range of conditions over which it will yield significant improvement over the one-strip method.

Gnoffo, P. A.↗

The Control Network of Mars: October 1984

Strips of Viking mapping pictures are being added to the planetwide control networks of Mars. These high resolution strips run from the Viking 1 lander site east to Airy-O, north along the 0 deg meridian to 60 deg latitude, southwest through the Viking 1 lander site to the equator, and along the equator encircling the planet. Everywhere along these strips, old points are incorporated in the measurements, thus assuring that the strips and planetwide net make a single large data set. The control points are much denser in the areas covered by the strips than in those regions not covered by strips and their coordinates of the control points is estimated to be less than 3 km and the error in longitude of a few points near Airy-O is less than 40 m. The horizontal coordinates of the control points on Mars have been updated with a single-block planetwide analytical triangulation. The standard error of measurement was 18.06 micron m. The longitude of the Viking 1 lander site was 47 deg.962 and the latitude 22 deg. 480. The latitude of Airy-O was -5 deg. 152.

Davies, M. E.↗

Numerical-perturbation technique for stability of flat-plate boundary layers with suction

A numerical-perturbation scheme is proposed for determining the stability of flows over plates with suction through a finite number of porous suction strips. The basic flow is calculated as the sum of the Blasius flow and closed-form linearized triple-deck solutions of the flow due to the strips. A perturbation technique is used to determine the increment a(ij) in the complex wavenumber at a given location x(j) due to the presence of a strip centered at x(i). The end result is a set of influence coefficients that can be used to determine the growth rates and amplification factors for any suction levels without repeating the calculations. The numerical-perturbation results are verified by comparison with interacting boundary layers for the case of six strips and the experimental data of Reynolds and Saric for single- and multiple-strip configurations. The influence coefficient form of the solution suggests a scheme for optimizing the strip configuration. The results show that one should concentrate the suction near branch I of the neutral stability curve, a conclusion verified by the experiments.

Reed, H. L.↗

Heat transfer in rotating serpentine passages with trips skewed to the flow

Experiments were conducted to determine the effects of buoyancy and Coriolis forces on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a large scale, multi-pass, heat transfer model with both radially inward and outward flow. Trip strips, skewed at 45 deg to the flow direction, were machined on the leading and trailing surfaces of the radial coolant passages. An analysis of the governing flow equations showed that four parameters influence the heat transfer in rotating passages: coolant-to-wall temperature, rotation number, Reynolds number, and radius-to-passage hydraulic diameter ratio. The first three of these four parameters were varied over ranges which are typical of advanced gas turbine engine operating conditions. Results were correlated and compared to previous results from similar stationary and rotating models with smooth walls and with trip strips normal to the flow direction. The heat transfer coefficients on surfaces, where the heat transfer decreased with rotation and buoyancy, decreased to as low as 40 percent of the value without rotation. However, the maximum values of the heat transfer coefficients with high rotation were only slightly above the highest levels previously obtained with the smooth wall models. It was concluded that (1) both Coriolis and buoyancy effects must be considered in turbine blade cooling designs with trip strips, (2) the effects of rotation are markedly different depending upon the flow direction, and (3) the heat transfer with skewed trip strips is less sensitive to buoyancy than the heat transfer in models with either smooth or normal trips. Therefore, skewed trip strips rather than normal trip strips are recommended and geometry-specific tests are required for accurate design information.

Johnson, B. V.↗