Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

State of the Art in Hadron Therapy

Charged particle beams offer an improved dose conformation to the target volume as compared to photon radiotherapy, with better sparing of normal tissue structures close to the target. In addition, beams of ions heavier than helium exhibit a strong increase of the Linear Energy Transfer (LET) in the Bragg peak as compared to the entrance region. These physical and biological properties make ion beams more favorable for radiation therapy of cancer than photon beams. As a consequence, particle therapy with protons and heavy ions has gained increasing interest worldwide. This contribution summarizes the physical and biological principles of charged particle therapy with ion beams and highlights some of the developments in the field of beam delivery, the principles of treatment planning and the determination of absorbed dose in ion beams. The clinical experience gathered so far with carbon ion therapy is briefly reviewed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First Results from MIPP

Measurements of neutrino cross-section and oscillations depend heavily on neutrino flux predictions. Such predictions rely on hadron-nucleus interaction cross-section data, and yet the data are scarce. The E907 Main Injector Particle Production (MIPP) experiment at Fermilab is a full acceptance spectrometer with excellent particle identification capabilities. MIPP has collected {approx}15x10{sup 6} events of p's, {pi}'s and K's at various momenta (from 5 to 120 GeV) on several targets including beryllium and carbon. In particular, MIPP has collected hadron production data on a spare NuMI target using 120 GeV/c protons from the Main Injector. We review the experiment, performance of the spectrometer and show preliminary results of particle production ratios of {pi}{sup -}/{pi}{sup +}, K{sup +}/{pi}{sup +}, K{sup -}/{pi}{sup -}, and K{sup -}/K{sup +} in bins of longitudinal and transverse momentum for thin and thick carbon targets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical Implementation Of Megavoltage Cone Beam CT As Part Of An IGRT Program

Knowing where the tumor is at all times during treatment is the next challenge in the field of radiation therapy. This issue has become more important because with treatments such as Intensity Modulated Radiation Therapy (IMRT), healthy tissue is spared by using very tight margins around the tumor. These tight margins leave very small room for patient setup errors. The use of an imaging modality in the treatment room as a way to localize the tumor for patient set up is generally known as 'Image Guided Radiation Therapy' or IGRT. This article deals with a form of IGRT known as Megavoltage Cone Beam Computed Tomography (MCBCT) using a Siemens Oncor linear accelerator currently in use at Firelands Regional Medical Center. With MCBCT, we are capable of acquiring CT images right before the treatment of the patient and then use this information to position the patient tumor according to the treatment plan. This article presents the steps followed in order to clinically implement this system, as well as some of the quality assurance tests suggested by the manufacturer and some tests developed in house.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indications of Carbon Ion Therapy at CNAO

CNAO will be a dual center capable of providing therapeutic beams of protons and carbon ions with maximum energy of 400 MeV/u. At the beginning, it will be equipped with three treatment rooms with fixed horizontal and vertical beam lines. In a subsequent phase, two more rooms with a rotating gantry are foreseen. An active spot scanning dose delivery system will be employed. Initially, 80% of the treatments will be carried out with carbon ions. All patients will be treated within clinical trials to assess carbon ion indications with an evidence-based methodology. Seven disease-specific working groups have been developed: lung tumors, liver tumors, sarcomas, head and neck tumors, central nervous system lesions, eye tumors and pediatric tumors. The last two groups will be treated mainly with protons. In the first phase, CNAO will focus on head and neck cancers, treating inoperable, residual or recurrent malignant salivary gland tumors, mucosal melanoma, adenocarcinoma and unfavorably located SCC (nasal and paranasal sinuses). Carbon ions will be employed as a boost in the treatment of locally advanced, poor prognosis, SCC of the hypopharynx and tongue base. Bone and soft tissue sarcomas of the extremity will be treated with a limb-sparing approach, and trunk sarcomas will be treated with exclusive or post-operative irradiation. Skull base tumors (chordoma and chondrosarcoma), recurrent or malignant meningioma and glial tumors will be treated with carbon ions. After sufficient expertise has been gained in coping with organ motion, CNAO will start treating thoracic and abdominal targets. HCC will be treated in inoperable patients with one or more lesions that can be included in a single CTV. Early stage NSCLC will be treated. In the second phase, two more groups on gynecological malignancies and digestive tumors (esophageal cancer, rectal cancer, pancreatic cancer) will be created.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scanned Carbon Pencil Beams for Tumor Therapy

At GSI a fully active beam application has been developed for tumor therapy with carbon ions. In this so-called rasterscan system the tumor volume is typically split into {approx}60 slices of iso-energies taken from a list of 252 energies ranging from {approx}90-430 MeV/u(range: 1.8-30.7 cm). The energies can be combined with variable beam diameters and intensities. For each iso-energy slice beam is requested from the synchrotron and delivered as a narrow pencil beam (beam's full width at half maximum 3-10 mm). For lateral target coverage this pencil beam is deflected to several hundreds of grid positions per iso-energy slice by orthogonal dipole magnets. At each grid position an optimized number of particles is deposited intensity-controlled, i.e. ionization chambers monitor the dose deposition and trigger deflection to the next grid position once the required dose level is achieved. This method allows intensity-modulated treatment fields necessary to deposit a uniform biological effective dose. Additionally, it allows for simultaneous optimization of multiple fields that allow better sparing of organs at risk partially or fully surrounded by the tumor. Scanned beam delivery facilitates target conformal and homogeneous dose delivery for stationary targets. For tumors located in the head and neck as well as tumors in the pelvic region very promising results were achieved in the carbon therapy pilot project started at GSI in 1993. A comparable project is conducted at Paul-Scherrer-Institut (PSI) in Switzerland with a scanned proton beam. One of the current research topics is the treatment of moving targets such as lung tumors. Scanned beam delivery requires but also offers possibilities to conformably irradiate moving target sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning

Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contemporary Proton Therapy Systems Adequately Protect Patients from Exposure to Stray Radiation

Proton beam therapy has provided safe and effective treatments for a variety of adult cancers. In recent years, there has been increasing interest in utilizing proton therapy for pediatric cancers because it allows better sparing of healthy tissues. Minimizing exposures of normal tissues is especially important in children because they are highly susceptible to consequential late effects, including the development of a radiogenic second cancer, which may occur years or even decades after treatment of the first cancer. While the dosimetric advantage of therapeutic proton beams is well understood, relatively little attention has been paid to the whole-body exposure to stray neutron radiation that is inherent in proton therapy. In this report, we review the physical processes that lead to neutron exposures, discuss the potential for mitigating these exposures using advanced proton beam delivery systems, and present a comparative analysis of predicted second cancer incidence following various external beam therapies. In addition, we discuss uncertainties in the relative biological effectiveness of neutrons for carcinogenesis and the impact that these uncertainties have on second-cancer risk predictions for survivors of adult and childhood cancer who receive proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contribution To Degradation Study, Behavior Of Unsaturated Polyester Resin Under Neutron Irradiation

Applications of unsaturated polyester thermosetting resins are numerous in construction sector, in transport, electric spare parts manufactures, consumer goods, and anticorrosive materials. This survey reports the effect of thermosetting polymer degradation (unsaturated polyester): degradation by neutrons irradiation. In order to evaluate the deterioration of our material, some comparative characterizations have been done between standard samples and damaged ones. Scanning electron microscopy (SEM), ultrasonic scanning, hardness test (Shore D) are the techniques which have been used. The exposure to a neutrons flux is carried out in the column of the nuclear research reactor of Draria (Algiers-Algeria). The energetic profile of the incidental fluxes is constituted of fast neutrons (PHI{sub R} = 3.10{sup 12} n.cm{sup -2}.s{sup -1}, E = 2 Mev) of thermal neutrons (PHI{sub TH} = 10{sup 13} n.cm{sup -2}.s{sup -1}; E = 0.025 ev) and epithermal neutrons (PHI{sub epi} = 7.10{sup 11} n.cm{sup -2}.s{sup -1}; E>4,9 ev). The received dose flow is 0,4 Kgy. We notice only a few scientific investigations can be found in this field. In comparison with the standard sample (no exposed) it is shown that the damage degree is an increasing process with the exposure. Concerning the description of irradiation effects on polymers, we can advance that several reactions are in competition: reticulation, chain break, and oxidation by radical mechanism. In our case the incidental particle of high energy fast neutrons whose energy is greater or equal to 2 Mev, is braked by the target with a nuclear shock during which the incidental particle transmits a part of its energy to an atom. If the energy transfer is sufficient, the nuclear shock permits to drive out an atom of its site the latter will return positioning interstitially, the energy that we used oversteps probably the energy threshold (displacement energy). This fast neutrons collision with target cores proceeds to an indirect ionization by the preliminary creation of excited secondary species that will generate ionization. Scanning electron microscopy (SEM) performed with an acceleration tension of 0,7 kV shows clearly the caused damage. This observation seems to indicate the presence of major chain breaks for the sample bombarded during 90 minutes. Let us note that the presence of benzenic cores improves behavior toward radiations indeed the chemical function recognized as the most stable to radiations is the aromatic ring. In order to value the rigidity of our material we have determined the Young's modulus . The values are 7.17, 7.60, 8.39 and 8.96 Gpa respectively for blank samples, 30, 60 and 90 minutes exposure ones. Thus, we remark an increase of Young's modulus that can be interpreted in terms of reticulation, provided to use the level of irradiation dose.

36 MATERIALS SCIENCE↗

Introduction to Ion Beam Therapy

Presently, ion beam therapy reaches an increasing interest within the field of radiation therapy, which is caused by the promising clinical results obtained in the last decades. Ion beams enable higher dose conformation to the tumor and increased sparing of the surrounding tissue in comparison to the standard therapy using high energy photons. Heavy ions, like carbon, offer in addition increased biological effectiveness, which makes them suitable for treatment of radioresistant tumors. This contribution gives an overview over the physical and biological properties of ion beams. Common fundamental principles of ion beam therapy are summarized and differences between standard therapy with high energy photons, proton and carbon ion therapy are discussed. The technologies used for the beam production and delivery are introduced, with emphasis to the differences between passive and active beam delivery systems. The last part concentrates on the quality assurance in ion therapy. Specialties of dosimetry in medical ion beams are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning for Ion Beam Therapy

Beams of charged particles offer an improved dose conformation to the target volume as compared to photon radiotherapy, with better sparing of normal tissue structures close to the target. In addition, beams of ions heavier than helium exhibit a strong increase of the Linear Energy Transfer (LET) in the Bragg peak as compared to the entrance region, resulting in a higher biological efficiency in the target region. These physical and biological properties make ion beams more favorable for radiation therapy of cancer than photon beams. As a consequence, particle therapy with heavy ions has gained increasing interest worldwide. To fully benefit from the advantages of ion radiotherapy, appropriate treatment planning has to be done--taking into account the specific characteristics of ion beams, e.g. the inverted depth-dose profile, nuclear fragmentation, and increase radiobiological effectiveness. This paper describes in brief the approach taken at GSI Darmstadt and HIT Heidelberg for an active 3D beam scanning system.

43 PARTICLE ACCELERATORS↗

Synchrotron Radiation Therapy from a Medical Physics point of view

Synchrotron radiation (SR) therapy is a promising alternative to treat brain tumors, whose management is limited due to the high morbidity of the surrounding healthy tissues. Several approaches are being explored by using SR at the European Synchrotron Radiation Facility (ESRF), where three techniques are under development Synchrotron Stereotactic Radiation Therapy (SSRT), Microbeam Radiation Therapy (MRT) and Minibeam Radiation Therapy (MBRT).The sucess of the preclinical studies on SSRT and MRT has paved the way to clinical trials currently in preparation at the ESRF. With this aim, different dosimetric aspects from both theoretical and experimental points of view have been assessed. In particular, the definition of safe irradiation protocols, the beam energy providing the best balance between tumor treatment and healthy tissue sparing in MRT and MBRT, the special dosimetric considerations for small field dosimetry, etc will be described. In addition, for the clinical trials, the definition of appropiate dosimetry protocols for patients according to the well established European Medical Physics recommendations will be discussed. Finally, the state of the art of the MBRT technical developments at the ESRF will be presented. In 2006 A. Dilmanian and collaborators proposed the use of thicker microbeams (0.36-0.68 mm). This new type of radiotherapy is the most recently implemented technique at the ESRF and it has been called MBRT. The main advantage of MBRT with respect to MRT is that it does not require high dose rates. Therefore it can be more easily applied and extended outside synchrotron sources in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic T{sub 2}-mapping during magnetic resonance guided high intensity focused ultrasound ablation of bone marrow

Focal bone tumor treatments include amputation, limb-sparing surgical excision with bone reconstruction, and high-dose external-beam radiation therapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) is an effective non-invasive thermotherapy for palliative management of bone metastases pain. MR thermometry (MRT) measures the proton resonance frequency shift (PRFS) of water molecules and produces accurate (<1 Degree-Sign C) and dynamic (<5s) thermal maps in soft tissues. PRFS-MRT is ineffective in fatty tissues such as yellow bone marrow and, since accurate temperature measurements are required in the bone to ensure adequate thermal dose, MR-HIFU is not indicated for primary bone tumor treatments. Magnetic relaxation times are sensitive to lipid temperature and we hypothesize that bone marrow temperature can be determined accurately by measuring changes in T{sub 2}, since T{sub 2} increases linearly in fat during heating. T{sub 2}-mapping using dual echo times during a dynamic turbo spin-echo pulse sequence enabled rapid measurement of T{sub 2}. Calibration of T{sub 2}-based thermal maps involved heating the marrow in a bovine femur and simultaneously measuring T{sub 2} and temperature with a thermocouple. A positive T{sub 2} temperature dependence in bone marrow of 20 ms/ Degree-Sign C was observed. Dynamic T{sub 2}-mapping should enable accurate temperature monitoring during MR-HIFU treatment of bone marrow and shows promise for improving the safety and reducing the invasiveness of pediatric bone tumor treatments.

60 APPLIED LIFE SCIENCES↗

Comparison of the biological effectiveness of 45 MeV C-ions and {gamma}-rays in inducing early and late effects in normal human primary fibroblasts

Investigation of the mechanisms underlying the biological effects induced by densely ionizing radiation has relevant implications in both radiation protection and therapy. In particular, the possible advantages of hadrontherapy with respect to conventional radiotherapy in terms of high conformal tumor treatment and sparing of healthy tissues are well known. Further improvements are limited by lack of radiobiological knowledge, particularly about the specific cellular response to the damage induced by particles of potential interest for tumor treatment. This study compares early and late effects induced in AG01522 normal human primary fibroblasts by {gamma}-rays and C-ions having E {approx} 45 MeV/u at the cell entrance, corresponding to LET (in water) {approx} 49 keV/{mu}m. Different end points have been investigated, namely: cell killing and lethal mutation, evaluated as early and delayed reproductive cell death, respectively; chromosome damage, as measured by micronuclei induction (MN); DNA damage, in terms of DSB induction and repair, as measured by the H2AX phosphorylation/dephosphorylation kinetics. Linear dose-response relationships were found for cell killing and induction of lethal mutations, with RBEs of about 1.3 and 1.6 respectively, indicating that the presence of genomic instability is greater in the progeny of C-ions irradiated cells. H2AX phosphorylation/dephosphorylation kinetics have shown a maximum foci number at 30 min after irradiation, higher for {gamma}-rays than for C-ions. However, in the first 12 h the fraction of residual {gamma}-H2AX foci was higher for C-ions irradiated cells, indicating a lower removal rate, possibly related to multiple/more complex damage along the particle track, with respect to the sparse lesions produced by {gamma}-rays. MN induction, observed after 72 h from irradiation, was also greater for C-ions. Overall, these data indicate a more severe DNA damage induced by 45 MeV/u C-ions with respect to {gamma}-rays, likely responsible of an increased cellular misrepair, leading to the greater observed levels of chromosome damage and, eventually, of genomic instability. They give strong support to the idea that higher damage severity at molecular level, determined by the typical deposition pattern of densely ionizing radiation, is the earliest relevant factor for the more severe late effects at cellular level.

61 RADIATION PROTECTION AND DOSIMETRY↗

The analysis of ball's motion in the torus-shaped autoequalizer

The reduction of vibrations in rotary systems is necessary condition for the development of constructions with high quality requirements. Among the devices that are able to reduce rotor's vibrations are automatic balancers with balls, liquid, etc. Autoequalizers with torus-shaped body contain one ball-shaped adjustment mass that can freely roll both in the ring direction and in the cross section. This enables reducing to the minimum the force of resistance at the ball's moving, but simultaneously decreases the chance of launching the autoequalizer in the autobalancing regime. It has been stated that the ball in the working state is influenced by forces that are aimed at moving it in the body of the autoequalizer towards the side opposite to the imbalance. The design of an autoequalizer that ensures working state in which at rotation the ball stops relative to the autoequalizer's body opposite to the imbalance has been experimentally worked out. The autoequalizer is made up of the mathematical model with two differential equations. In the result of the calculations it has been proved that the ball of an equalizer with the torus-shaped body has at least two movement conditions one of which is a working state, and another one is a spare state.

36 MATERIALS SCIENCE↗

On the role of ion-based imaging methods in modern ion beam therapy

External beam radiotherapy techniques have the common aim to maximize the radiation dose to the target while sparing the surrounding healthy tissues. The inverted and finite depth-dose profile of ion beams (Bragg peak) allows for precise dose delivery and conformai dose distribution. Furthermore, increased radiobiological effectiveness of ions enhances the capability to battle radioresistant tumors. Ion beam therapy requires a precise determination of the ion range, which is particularly sensitive to range uncertainties. Therefore, novel imaging techniques are currently investigated as a tool to improve the quality of ion beam treatments. Approaches already clinically available or under development are based on the detection of secondary particles emitted as a result of nuclear reactions (e.g., positron-annihilation or prompt gammas, charged particles) or transmitted high energy primary ion beams. Transmission imaging techniques make use of the beams exiting the patient, which have higher initial energy and lower fluence than the therapeutic ones. At the Heidelberg Ion Beam Therapy Center, actively scanned energetic proton and carbon ion beams provide an ideal environment for the investigation of ion-based radiography and tomography. This contribution presents the rationale of ion beam therapy, focusing on the role of ion-based transmission imaging methods towards the reduction of range uncertainties and potential improvement of treatment planning.

60 APPLIED LIFE SCIENCES↗

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: A Monte Carlo study

Depending on the location and depth of tumor, the electron or photon beams might be used for treatment. Electron beam have some advantages over photon beam for treatment of shallow tumors to spare the normal tissues beyond of the tumor. In the other hand, the photon beam are used for deep targets treatment. Both of these beams have some limitations, for example the dependency of penumbra with depth, and the lack of lateral equilibrium for small electron beam fields. In first, we simulated the conventional head configuration of Varian 2300 for 16 MeV electron, and the results approved by benchmarking the Percent Depth Dose (PDD) and profile of the simulation and measurement. In the next step, a perforated Lead (Pb) sheet with 1mm thickness placed at the top of the applicator holder tray. This layer producing bremsstrahlung x-ray and a part of the electrons passing through the holes, in result, we have a simultaneous mixed electron and photon beam. For making the irradiation field uniform, a layer of steel placed after the Pb layer. The simulation was performed for 10×10, and 4×4 cm2 field size. This study was showed the advantages of mixing the electron and photon beam by reduction of pure electron's penumbra dependency with the depth, especially for small fields, also decreasing of dramatic changes of PDD curve with irradiation field size.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent performance and ignition tests of the pulsed SNS H{sup −} source for 1-MW neutron production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H{sup −} beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ∼0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H{sup −} beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation. At the request of the authors and the Proceedings Editor this article has been updated to include References 3–13, which were present in the author’s original submission but were lost during manuscript processing in the Proceedings Editor's office. The updated article was published on 5 May 2015.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗