Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Nuclear Criticality Safety Integral Experiment Covariance Determination

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. Commonly, the uncertainty quantification ignores correlations between experiments that share components. Experiments such as the TEX (Thermal/Epithermal eXperiments) campaigns consist of many shared parts between experiments, such as fuel, which creates a strong correlation in their errors. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes a software package that uses an intuitive method of determining the covariance for each of the experimental components, providing a correlation matrix for each family of parts across the multiple cases examined within a benchmark. The code uses the TEX-HEU campaign as a proof of concept, and we show that the correlations can be calculated with information commonly found in ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. The estimated covariances are used in χ 2 trending studies to evaluate their impact on nuclear data validation. The covariance determination code can be easily integrated into current benchmark evaluations as well as reevaluating legacy benchmark uncertainties. Uncertainty correlation calculations should become the baseline for criticality safety integral experiment benchmarks and can now be easily calculated with the described software package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Criticality Safety Integral Experiment Covariance Determination

Integral benchmarks for criticality safety and nuclear data validation require expensive uncertainty quantification studies. Commonly, the uncertainty quantification ignores correlations between experiments that share components. Experiments such as the TEX (Thermal/Epithermal eXperiments) campaigns consist of many shared parts, such as fuel, which create a strong correlation in their uncertainties. While these correlations are known to exist, they are often not estimated due to the complexity of such calculations. This paper describes a software package that uses an intuitive method of determining the covariance for each of the experimental components, providing a correlation matrix for each family of parts across the multiple cases examined within a benchmark. The code uses the TEX-HEU campaign as a proof of concept, and we show that the correlations can be calculated with information commonly found in ICSBEP (International Criticality Safety Benchmark Evaluation Project) benchmarks. The estimated covariances are used in χ 2 trending studies to evaluate their impact on nuclear data validation. Without covariances, χ 2 per degree of freedom was calculated as 2.203 and with covariances it was 1.179. The difference shows that omitting covariance information may cause overly pessimistic bias quantifications. The covariance determination code can be easily integrated into current benchmark evaluations as well as reevaluating legacy benchmark uncertainties. Uncertainty correlation calculations should become the baseline for criticality safety integral experiment benchmarks and can now be easily calculated with the described software package.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AFR-100 safety analyses

The Advanced Fast Reactor-100 (AFR-100) is Argonne National Laboratory's 250 MWth metal-fueled modular sodium-cooled pool-type fast reactor concept. [1] A series of accident sequences that focused on the AFR-100's ability to provide protection against reactor damage during low probability accident sequences resulting from multiple equipment failures were examined. Protected and Unprotected Loss of Flow (PLOF and ULOF) and Unprotected Transient Over-Power (UTOP) accidents were simulated using the SAS4A/SASSYS-1 safety analysis code. The large heat capacity of the sodium in the pool-type reactor allows the AFR-100 to absorb large amounts of energy during a PLOF with relatively small temperature increases throughout the system. During a ULOF with a 25-second flow halving time, coolant and cladding temperatures peak around 720 deg. C within the first minute before reactivity feedback effects decrease power to match the flow. Core radial expansion and fuel Doppler provide the necessary feedback during the UTOP to bring the system back to critical before system temperatures exceed allowable limits. Simulation results indicate that adequate ULOF safety margins exist for the AFR-100 design with flow halving times of twenty-five seconds. Significant safety margins are maintained for PLOF accidents as well as UTOP accidents if a rod stop is used. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Major results from safety-related integral effect tests with VISTA-ITL for the SMART design

A series of integral effect tests (IETs) was performed by the Korea Atomic Energy Research Inst. (KAERI) using the VISTA integral test loop (VISTA-ITL) as a small-scale IET program. Among them this paper presents major results acquired from the safety-related IETs with the VISTA-ITL facility for the SMART design. Three small-break loss-of-coolant accident (SBLOCA) tests of safety injection system (SIS) line break, shutdown cooling system (SCS) line break and pressurizer safety valve (PSV) line break were successfully performed and the transient characteristics of a complete loss of flowrate (CLOF) was simulated properly with the VISTA-ITL facility. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced electrical penetration components meet the high safety standards required for China's HTR-PM Shidaowan and generation mPower small modular reactors - 300

Enhanced glass-to-metal feedthroughs will be used to carry key instrumentation and control (I and C) signals in China's high-temperature, gas-cooled pebble-bed modular reactor (HTR-PM) at Shidaowan, and in Small Modular Reactor (SMR) prototyping. Chinergy Co., Ltd and Jiamusi Electric Machine Co., Ltd will use the feedthroughs, also called electrical penetration assemblies (EPAs), at the Shidaowan twin-reactor high temperature reactor (HTR). These feedthroughs are manufactured using specialized processes that make them far more robust than counterparts made with organic or ceramic materials. Improved EPAs manufactured by SCHOTT are the only feedthrough solution that can be used in the primary loop of an HTR because organic seals cannot withstand the high temperatures and pressures of this environment. Glass-to-metal seals (GTMS) are made using inorganic, non-aging materials which enable a virtually unlimited lifespan in high-temperature, high-radiation and high-pressure applications. This I and C technology package is being enhanced by the development and testing of new mineral-insulated (MI) cable connectors and EPAs made of crystallized glass-ceramic combined with superalloys. The EPAs have a maintenance-free lifespan of over 60 years, preventing any outage time related to these components and subsequently reducing costs associated with shutdowns. They are far more robust than organic seals and provide increased safety at a lower lifetime cost. Resistance against high pressure and high temperature are especially ideal qualities that make EPAs a valuable choice for environments with high standards for fire protection, such as nuclear plants, subsea oil drilling, or any other underwater application. Due to their significant offering of safety-relevant qualities, the EPAs have also been chosen by BWXT for implementation in its mPower SMR. Small modular reactor requirements are complex and very challenging but are met by the new EPA components, which will help form a strong I and C safety chain. Unlike ordinary compression glass-to-metal seals, GTMS with crystallized glass-ceramic have the ability to withstand temperatures of over 350 deg. C / 662 deg. F and operating pressures of 3500 bar. Furthermore, their lifetime is qualified for up to 60 years, including pressure and radiation requirements in accordance with the latest IEC/IEEE standards. Higher-specification EPAs and MI cable connectors have been designed into severe accident I and C instruments, including advanced hydrogen and oxygen sensors that exceed the challenging requirements of both HTR and SMR applications. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantitative Analysis Guidance in Safety Software Validation

Quantitative analysis in software development has been a challenging topic over the years in safety software. While qualitative processes for vigorous safety software verification and validation (V and V) have been provided through standard such as IEEE 1012, quantitative analysis for V and V tasks such as correctness, completeness or accuracy evaluation have not been formally defined. In practice, there are quantitative analyses in terms of using software metrics. Many of these software metrics are useful in analyzing the test results. Some of them are used for providing guidance in code evaluation activities e.g. numbers of line of codes not exceeding certain limits, recursive calls are not allowed, etc. However, few can be used for providing quantitative analysis guidance for the V and V tasks such as completeness evaluation. AREVA Federal Services (AFS) has provided services for many nuclear projects in US. Through compliance with IEEE 1012, AFS V and V processes have provided vigorous qualitative processes ensuring quality level of the software products used in the project meeting the required nuclear software level. In addition, quantitative analysis is developed to provide structured validation framework ensuring 'zero defect' in the software products. This paper describes some aspects of the quantitative approaches using a sample safety application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International organization for standardization on the topic of nuclear criticality safety (ISO TC85/SC5/WG8) - 14244

This paper is a four-year update (i.e. 2011 - 2015) about the progress and activities of the International Organization for Standardization (ISO), Technical Committee 85 (TC85) on Nuclear energy, Subcommittee 5 (SC5) on Nuclear fuel cycle, Working Group 8 (WG8) on Nuclear criticality safety. The update provides a brief summary of historic standards developed by ISO TC85/SC5/WG8 and descriptions about evolving standards for nuclear criticality safety. The update describes the potential value and relevance of indigenous standards and technological developments by OECD regarding nuclear criticality safety standards. Elements of the published WG8 ISO standards that have been incorporated into International Atomic Energy Agency non-consensus guides and standards are provided. A review of international participation and needed participation is also addressed along with the benefits to ISO participating member countries. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality safety enhancements for SCALE 6.2 and beyond - 14648

SCALE is a widely used suite of tools for nuclear systems modeling and simulation that provides comprehensive, verified and validated, user-friendly capabilities for criticality safety, reactor physics, radiation shielding, and sensitivity and uncertainty analysis. Since 1980, regulators, industry, and research institutions around the world have relied on SCALE for nuclear safety analysis and design. SCALE 6.2 provides several new capabilities and significant improvements in many existing features for criticality safety analysis. Enhancements are realized for nuclear data; multigroup resonance self-shielding; continuous-energy Monte Carlo analysis for sensitivity/uncertainty analysis, radiation shielding, and depletion; and graphical user interfaces. An overview of these capabilities is provided in this paper, and additional details are provided in several companion papers. (authors)

42 ENGINEERING↗

Molten Salt Reactor Safety Assessment - Three Approaches to A Common Objective

Safety adequacy assessment is central to nuclear power plant (NPP) licensing. Either NPP accident mitigation or prevention can result in adequate safety. Accident prevention, along with the the prevention of accident escalation, can be evaluated using either deterministic or probabilistic methods. Acceptable means to develop principal design criteria (PDCs) via probabilistic methods are provided in NRC Regulatory Guide 1.233 while advanced reactor design criteria are provided in NRC Regulatory Guide 1.232 (RG 1.232). Accident mitigation-based regulatory guidance for non-power reactors is provided in NUREG 1537. While RG 1.232 included class specific guidance for both sodium-cooled fast reactors and modular high-temperature gas-cooled reactors, it did not provide molten salt reactor (MSR) class specific guidance. Class specific design criteria more closely align with reactors in their class so will require less effort to employ to develop design specific PDCs. The American Nuclear Society has recently released a liquid-fueled MSR design safety standard (ANSI/ANS-20.2-2023) that provides class specific design criteria.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Is Nonflammability of Electrolyte Overrated in the Overall Safety Performance of Lithium Ion Batteries? A Sobering Revelation from a Completely Nonflammable Electrolyte

It has been widely assumed that the flammability of the liquid electrolyte is one of the most influential factors that determine the safety of lithium-ion batteries (LIBs). Following this consideration, a completely nonflammable electrolyte is designed and adopted for graphite||LiFePO 4 (Gr||LFP) batteries. Contrary to the conventional understanding, the completely nonflammable electrolyte with phosphorus-containing solvents exhibits inferior safety performance in commercial Gr||LFP batteries, in comparison to the flammable conventional LiPF 6 -organocarbonate electrolyte. Mechanistic studies identify the exothermic reactions between the electrolyte (especially the salt LiFSI) and the charged electrodes as the “culprit” behind this counterintuitive phenomenon. The discovery emphasizes the importance of reducing the electrolyte reactivity when designing safe electrolytes, as well as the necessity of evaluating safety performance of electrolytes on a battery level.

25 ENERGY STORAGE↗

Comprehensive Battery Safety Risk Evaluation: Aged Cells versus Fresh Cells Upon Mechanical Abusive Loadings

Abstract Despite their wide applications, lithium‐ion batteries (LIBs) have been struggling with their safety risks arising from different lifetime stages. Here, the NCMA pouch cell is taken as an example, and the safety of both fresh and aged cells from three milestone stages, that is, internal short circuit (ISC) triggering risk, ISC mode, and the subsequent thermal runaway (TR) consequence is investigated. By combining mechanical abusive testing and physics‐based models on commercialized cells with various states‐of‐health (SOH) and states‐of‐charge, it is discovered that the ISC triggering delays with the decay of SOH and soft ISC mode will be triggered more frequently, which is mainly due to the mechanical behaviors of the current collectors. The temperature rises and peak temperature during the subsequent TR also become milder for aged cells due to the reduced capacity and deterministic soft ISC process. Results here provide a mechanistic explanation of the safety risk comparison between the fresh and aged cells, offering cornerstone guidance to the evaluation and design of next‐generation safer LIBs.

25 ENERGY STORAGE↗

New Safety Feedback Control Design to Guarantee Adequate Frequency Performance in Microgrids

Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.

barrier function↗

Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evident filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Checklist to Improve Patient Safety in Interventional Radiology

To develop a specific RADiological Patient Safety System (RADPASS) checklist for interventional radiology and to assess the effect of this checklist on health care processes of radiological interventions. On the basis of available literature and expert opinion, a prototype checklist was developed. The checklist was adapted on the basis of observation of daily practice in a tertiary referral centre and evaluation by users. To assess the effect of RADPASS, in a series of radiological interventions, all deviations from optimal care were registered before and after implementation of the checklist. In addition, the checklist and its use were evaluated by interviewing all users. The RADPASS checklist has two parts: A (Planning and Preparation) and B (Procedure). The latter part comprises checks just before starting a procedure (B1) and checks concerning the postprocedural care immediately after completion of the procedure (B2). Two cohorts of, respectively, 94 and 101 radiological interventions were observed; the mean percentage of deviations of the optimal process per intervention decreased from 24 % before implementation to 5 % after implementation (p < 0.001). Postponements and cancellations of interventions decreased from 10 % before implementation to 0 % after implementation. Most users agreed that the checklist was user-friendly and increased patient safety awareness and efficiency. The first validated patient safety checklist for interventional radiology was developed. The use of the RADPASS checklist reduced deviations from the optimal process by three quarters and was associated with less procedure postponements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the Data of Monitoring the Safety of Hydraulic Structures in the Cryolithozone

Data of long-term monitoring of the accident rate and safety of hydraulic structures in the cryolithozone from 1776 to 2015 are analyzed. A refined classification of failures and safety criteria of dams on frozen ground is given and recommendations are proposed for improving the existing building codes with respect to designing earth dams in the cryolithozone with provision of their safety during operation.

42 ENGINEERING↗

Leveraging artificial intelligence and advanced food processing techniques for enhanced food safety, quality, and security: a comprehensive review

Artificial intelligence is emerging as a transformative force in addressing the multifaceted challenges of food safety, food quality, and food security. This review synthesizes advancements in AI-driven technologies, such as machine learning, deep learning, natural language processing, and computer vision, and their applications across the food supply chain, based on a comprehensive analysis of literature published from 1990 to 2024. AI enhances food safety through real-time contamination detection, predictive risk modeling, and compliance monitoring, reducing public health risks. It improves food quality by automating defect detection, optimizing shelf-life predictions, and ensuring consistency in taste, texture, and appearance. Furthermore, AI addresses food security by enabling resource-efficient agriculture, yield forecasting, and supply chain optimization to ensure the availability and accessibility of nutritious food resources. This review also highlights the integration of AI with advanced food processing techniques such as high-pressure processing, ultraviolet treatment, pulsed electric fields, cold plasma, and irradiation, which ensure microbial safety, extend shelf life, and enhance product quality. Additionally, the integration of AI with emerging technologies such as the Internet of Things, blockchain, and AI-powered sensors enables proactive risk management, predictive analytics, and automated quality control. By examining these innovations' potential to enhance transparency, efficiency, and decision-making within food systems, this review identifies current research gaps and proposes strategies to address barriers such as data limitations, model generalizability, and ethical concerns. These insights underscore the critical role of AI in advancing safer, higher-quality, and more secure food systems, guiding future research and fostering sustainable food systems that benefit public health and consumer trust.

AI↗

The role of driver head pose dynamics and instantaneous driving in safety critical events: Application of computer vision in naturalistic driving

This paper investigates the role of driver behavior especially head pose dynamics in safety–critical events (SCEs). Using a large dataset collected in a naturalistic driving study, this paper analyzes the head pose dynamics and driving behavior in moments leading up to crashes or near-crashes. The study uses advanced computer vision and mixed logit modeling techniques to identify patterns and relationships between drivers’ head pose dynamics and crash involvement. The results suggest that driver-head pose dynamics, especially poses that indicate distraction and movement volatility, are important factors that can contribute to undesirable safety outcomes. Marginal effects show that angular deviation for head pose dynamics indicated by yaw, pitch and roll increase the likelihood of crash intensity by 4.56%, 4.92% and 8.26% respectively. Furthermore, traffic flow and lane changing also contribute to increase in likelihood of crash intensity. These findings provide new insights into pre-crash factors, especially human factors and safety–critical events. The study highlights the importance of considering human factors in designing driver assistance systems and developing safer vehicles. This research contributes by examining naturalistic driving data at the microscopic level with early detection of behaviors that lead to SCEs and provides a basis for future research on automation.

33 ADVANCED PROPULSION SYSTEMS↗