Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STIMULUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Plastid position in Arabidopsis columella cells is similar in microgravity and on a random-positioning machine

In order to study gravity effects on plant structure and function, it may become necessary to remove the g-stimulus. On Earth, various instruments such as clinostats have been used by biologists in an attempt to neutralize the effects of gravity. In this study, the position of amyloplasts was assayed in columella cells in the roots of Arabidopsis thaliana (L.) Heynh. seedlings grown in the following conditions: on Earth, on a two-dimensional clinostat at 1 rpm, on a three-dimensional clinostat (also called a random-positioning machine, or an RPM), and in space (true microgravity). In addition, the effects of these gravity treatments on columella cell area and plastid area also were measured. In terms of the parameters measured, only amyloplast position was affected by the gravity treatments. Plastid position was not significantly different between spaceflight and RPM conditions but was significantly different between spaceflight and the classical two-dimensional clinostat treatments. Flanking columella cells showed a greater susceptibility to changes in gravity compared to the central columella cells. In addition, columella cells of seedlings that were grown on the RPM did not exhibit deleterious effects in terms of their ultrastructure as has been reported previously for seedlings grown on a two-dimensional clinostat. This study supports the hypothesis that the RPM provides a useful simulation of weightlessness.

Non-NASA Center↗

Three-dimensional organization of vestibular related eye movements to rotational motion in pigeons

During rotational motions, compensatory eye movement adjustments must continually occur in order to maintain objects of visual interest as stable images on the retina. In the present study, the three-dimensional organization of the vestibulo-ocular reflex in pigeons was quantitatively examined. Rotations about different head axes produced horizontal, vertical, and torsional eye movements, whose component magnitude was dependent upon the cosine of the stimulus axis relative to the animal's visual axis. Thus, the three-dimensional organization of the VOR in pigeons appears to be compensatory for any direction of head rotation. Frequency responses of the horizontal, vertical, and torsional slow phase components exhibited high pass filter properties with dominant time constants of approximately 3 s.

NASA Discipline Neuroscience↗

A dual-task investigation of automaticity in visual word processing

An analysis of activation models of visual word processing suggests that frequency-sensitive forms of lexical processing should proceed normally while unattended. This hypothesis was tested by having participants perform a speeded pitch discrimination task followed by lexical decisions or word naming. As the stimulus onset asynchrony between the tasks was reduced, lexical-decision and naming latencies increased dramatically. Word-frequency effects were additive with the increase, indicating that frequency-sensitive processing was subject to postponement while attention was devoted to the other task. Either (a) the same neural hardware shares responsibility for lexical processing and central stages of choice reaction time task processing and cannot perform both computations simultaneously, or (b) lexical processing is blocked in order to optimize performance on the pitch discrimination task. Either way, word processing is not as automatic as activation models suggest.

Attention↗

A signal detection model predicts the effects of set size on visual search accuracy for feature, conjunction, triple conjunction, and disjunction displays

Recently, quantitative models based on signal detection theory have been successfully applied to the prediction of human accuracy in visual search for a target that differs from distractors along a single attribute (feature search). The present paper extends these models for visual search accuracy to multidimensional search displays in which the target differs from the distractors along more than one feature dimension (conjunction, disjunction, and triple conjunction displays). The model assumes that each element in the display elicits a noisy representation for each of the relevant feature dimensions. The observer combines the representations across feature dimensions to obtain a single decision variable, and the stimulus with the maximum value determines the response. The model accurately predicts human experimental data on visual search accuracy in conjunctions and disjunctions of contrast and orientation. The model accounts for performance degradation without resorting to a limited-capacity spatially localized and temporally serial mechanism by which to bind information across feature dimensions.

Non-NASA Center↗

Spatial covert attention increases contrast sensitivity across the CSF: support for signal enhancement

This study is the first to report the benefits of spatial covert attention on contrast sensitivity in a wide range of spatial frequencies when a target alone was presented in the absence of a local post-mask. We used a peripheral precue (a small circle indicating the target location) to explore the effects of covert spatial attention on contrast sensitivity as assessed by orientation discrimination (Experiments 1-4), detection (Experiments 2 and 3) and localization (Experiment 3) tasks. In all four experiments the target (a Gabor patch ranging in spatial frequency from 0.5 to 10 cpd) was presented alone in one of eight possible locations equidistant from fixation. Contrast sensitivity was consistently higher for peripherally- than for neutrally-cued trials, even though we eliminated variables (distracters, global masks, local masks, and location uncertainty) that are known to contribute to an external noise reduction explanation of attention. When observers were presented with vertical and horizontal Gabor patches an external noise reduction signal detection model accounted for the cueing benefit in a discrimination task (Experiment 1). However, such a model could not account for this benefit when location uncertainty was reduced, either by: (a) Increasing overall performance level (Experiment 2); (b) increasing stimulus contrast to enable fine discriminations of slightly tilted suprathreshold stimuli (Experiment 3); and (c) presenting a local post-mask (Experiment 4). Given that attentional benefits occurred under conditions that exclude all variables predicted by the external noise reduction model, these results support the signal enhancement model of attention.

Non-NASA Center↗

Influence of central set on anticipatory and triggered grip-force adjustments

The effects of predictability of load magnitude on anticipatory and triggered grip-force adjustments were studied as nine normal subjects used a precision grip to lift, hold, and replace an instrumented test object. Experience with a predictable stimulus has been shown to enhance magnitude scaling of triggered postural responses to different amplitudes of perturbations. However, this phenomenon, known as a central-set effect, has not been tested systematically for grip-force responses in the hand. In our study, predictability was manipulated by applying load perturbations of different magnitudes to the test object under conditions in which the upcoming load magnitude was presented repeatedly or under conditions in which the load magnitudes were presented randomly, each with two different pre-load grip conditions (unconstrained and constrained). In constrained conditions, initial grip forces were maintained near the minimum level necessary to prevent pre-loaded object slippage, while in unconstrained conditions, no initial grip force restrictions were imposed. The effect of predictable (blocked) and unpredictable (random) load presentations on scaling of anticipatory and triggered grip responses was tested by comparing the slopes of linear regressions between the imposed load and grip response magnitude. Anticipatory and triggered grip force responses were scaled to load magnitude in all conditions. However, regardless of pre-load grip force constraint, the gains (slopes) of grip responses relative to load magnitudes were greater when the magnitude of the upcoming load was predictable than when the load increase was unpredictable. In addition, a central-set effect was evidenced by the fewer number of drop trials in the predictable relative to unpredictable load conditions. Pre-load grip forces showed the greatest set effects. However, grip responses showed larger set effects, based on prediction, when pre-load grip force was constrained to lower levels. These results suggest that anticipatory processes pertaining to load magnitude permit the response gain of both voluntary and triggered rapid grip force adjustments to be set, at least partially, prior to perturbation onset. Comparison of anticipatory set effects for reactive torque and lower extremity EMG postural responses triggered by surface translation perturbations suggests a more general rule governing anticipatory processes.

Non-NASA Center↗

Medial prefrontal cortex acetylcholine injection-induced hypotension: the role of hindlimb vasodilation

The injection of acetylcholine (ACh) into the cingulate region of the medial prefrontal cortex (MPFC) causes a marked fall in arterial blood pressure which is not accompanied by changes in heart rate. The purpose of the present study was to investigate the hemodynamic basis for this stimulus-induced hypotension in Sprague-Dawley rats. The study was designed to determine whether a change in the vascular resistance of hindlimb, renal or mesenteric vascular beds contributes to the fall in arterial pressure in response to ACh injection into the cingulate cortex. Miniature pulsed-Doppler flow probes were used to measure changes in regional blood flow and vascular resistance. The results indicated that the hypotensive response was largely due to a consistent and marked vasodilation in the hindlimb vascular bed. On this basis, an additional experiment was then undertaken to determine the mechanisms that contribute to hindlimb vasodilation. The effect of interrupting the autonomic innervation of one leg on the hindlimb vasodilator response was tested. Unilateral transection of the lumbar sympathetic chain attenuated the cingulate ACh-induced vasodilation in the ipsilateral, but not in the contralateral hindlimb. These results suggest that the hypotensive response to cingulate cortex-ACh injection is caused by skeletal muscle vasodilation mediated by a sympathetic chain-related vasodilator system.

Non-NASA Center↗

Tracking with the mind's eye

The two components of voluntary tracking eye-movements in primates, pursuit and saccades, are generally viewed as relatively independent oculomotor subsystems that move the eyes in different ways using independent visual information. Although saccades have long been known to be guided by visual processes related to perception and cognition, only recently have psychophysical and physiological studies provided compelling evidence that pursuit is also guided by such higher-order visual processes, rather than by the raw retinal stimulus. Pursuit and saccades also do not appear to be entirely independent anatomical systems, but involve overlapping neural mechanisms that might be important for coordinating these two types of eye movement during the tracking of a selected visual object. Given that the recovery of objects from real-world images is inherently ambiguous, guiding both pursuit and saccades with perception could represent an explicit strategy for ensuring that these two motor actions are driven by a single visual interpretation.

NASA Discipline Neuroscience↗

The kinetics of translocation and cellular quantity of protein kinase C in human leukocytes are modified during spaceflight

Protein kinase C (PKC) is a family of serine/threonine kinases that play an important role in mediating intracellular signal transduction in eukaryotes. U937 cells were exposed to microgravity during a space shuttle flight and stimulated with a radiolabeled phorbol ester ([3H]PDBu) to both specifically label and activate translocation of PKC from the cytosol to the particulate fraction of the cell. Although significant translocation of PKC occurred at all g levels, the kinetics of translocation in flight were significantly different from those on the ground. In addition, the total quantity of [3H]PDBu binding PKC was increased in flight compared to cells at 1 g on the ground, whereas the quantity in hypergravity (1.4 g) was decreased with respect to 1 g. Similarly, in purified human peripheral blood T cells the quantity of PKCdelta varied in inverse proportion to the g level for some experimental treatments. In addition to these novel findings, the results confirm earlier studies which showed that PKC is sensitive to changes in gravitational acceleration. The mechanisms of cellular gravisensitivity are poorly understood but the demonstrated sensitivity of PKC to this stimulus provides us with a useful means of measuring the effect of altered gravity levels on early cell activation events.

short duration↗

Steady and transient fluid shear stress stimulate NO release in osteoblasts through distinct biochemical pathways

Fluid flow has been shown to be a potent stimulus in osteoblasts and osteocytes and may therefore play an important role in load-induced bone remodeling. The objective of this study was to investigate the characteristics of flow-activated pathways. Previously we reported that fluid flow stimulates rapid and continuous release of nitric oxide (NO) in primary rat calvarial osteoblasts. Here we demonstrate that flow-induced NO release is mediated by shear stress and that this response is distinctly biphasic. Transients in shear stress associated with the onset of flow stimulated a burst in NO production (8.2 nmol/mg of protein/h), while steady flow stimulated sustained NO production (2.2 nmol/mg of protein/h). Both G-protein inhibition and calcium chelation abolished the burst phase but had no effect on sustained production. Activation of G-proteins stimulated dose-dependent NO release in static cultures of both calvarial osteoblasts and UMR-106 osteoblast-like cells. Pertussis toxin had no effect on NO release. Calcium ionophore stimulated low levels of NO production within 15 minutes but had no effect on sustained production. Taken together, these data suggest that fluid shear stress stimulates NO release by two distinct pathways: a G-protein and calcium-dependent phase sensitive to flow transients, and a G-protein and calcium-independent pathway stimulated by sustained flow.

Non-NASA Center↗

Effects of body orientation and rotation axis on pitch visual-vestibular interaction

Spatial transformations of the vestibular-optokinetic system must account for changes in head position with respect to gravity in order to produce compensatory oculomotor responses. The purpose of this experiment was to study the influence of gravity on the vestibulo-ocular reflex (VOR) in darkness and on visual-vestibular interaction in the pitch plane in human subjects using two different comparisons: (1) Earth-horizontal axis (EHA) rotation about an upright versus a supine body orientation, and (2) Earth-horizontal versus Earth-vertical (EVA) rotation axes. Visual-vestibular responses (VVR) were evaluated by measuring the slow phase velocity of nystagmus induced during sinusoidal motion of the body in the pitch plane (at 0.2 Hz and 0.8 Hz) combined with a constant-velocity vertical optokinetic stimulation (at +/- 36 degrees/s). The results showed no significant effect on the gain or phase of the VOR in darkness or on the VVR responses at 0.8 Hz between EHA upright and EHA supine body orientations. However, there was a downward shift in the VOR bias in darkness in the supine orientation. There were systematic changes in VOR and VVR between EHA and EVA for 0.2 Hz, including a reduced modulation gain, increased phase lead, and decreased bias during EVA rotation. The same trend was also observed at 0.8 Hz, but at a lesser extent, presumably due to the effects of eccentric rotation in our EVA condition and/or to the different canal input across frequencies. The change in the bias at 0.2 Hz between rotation in darkness and rotation with an optokinetic stimulus was greater than the optokinetic responses without rotation. During EHA, changes in head position relative to gravity preserve graviceptor input to the VVR regardless of body orientation. However, the modifications in VVR gain and phase when the rotation axis is aligned with gravity indicate that this graviceptive information is important for providing compensatory eye movements during visual-vestibular interaction in the pitch plane.

Non-NASA Center↗

Ventilatory responses to dynamic exercise elicited by intramuscular sensors

PURPOSE: Eight subjects, aged 27.0+/-1.6 yr, performed incremental workload cycling to investigate the contribution of skeletal muscle mechano- and metaboreceptors to ventilatory control during dynamic exercise. METHODS: Each subject performed four bouts of exercise: exercise with no intervention (CON); exercise with bilateral thigh cuffs inflated to 90 mm Hg (CUFF); exercise with application of lower-body positive pressure (LBPP) to 45 torr (PP); and exercise with 90 mm Hg thigh cuff inflation and 45 torr LBPP (CUFF+PP). Ventilatory responses and pulmonary gas exchange variables were collected breath-by-breath with concomitant measurement of leg intramuscular pressure. RESULTS: Ventilation (VE) was significantly elevated from CON during PP and CUFF+PP at workloads corresponding to > or = 60% CON peak oxygen uptake (VO2peak) and during CUFF at workloads > or = 80% CON VO2peak, P < 0.05. The VO2 at which ventilatory threshold occurred was significantly reduced from CON (2.17+/-0.28 L x min(-1)) to 1.60+/-0.19 L x min(-1), 1.45+/-0.15 L x min(-1), and 1.15+/-0.11 L x min(-1) during CUFF, PP, and CUFF+PP, respectively. The slope of the linear regression describing the VE/CO2 output relationship was increased from CON by approximately 22% during CUFF, 40% during PP, and 41% during CUFF+PP. CONCLUSIONS: As intramuscular pressure was significantly elevated immediately upon application of LBPP during PP and CUFF+PP without a concomitant increase in VE, it seems unlikely that LBPP-induced increases in VE can be attributed to activation of the mechanoreflex. These findings suggest that LBPP-induced reductions in perfusion pressure and decreases in venous outflow resulting from inflation of bilateral thigh cuffs may generate a metabolite sensitive intramuscular ventilatory stimulus.

Non-NASA Center↗

Restoration of peak vascular conductance after simulated microgravity by maximal exercise

We sought to determine if (i) peak vascular conductance of the calf was reduced following prolonged exposure to simulated microgravity, and (ii) if maximal cycle ergometry performed at the end of microgravity exposure stimulated a restoration of peak calf vascular conductance. To do this, peak vascular conductance of the calf was recorded following ischaemic plantar flexion exercise to fatigue in seven men after 16 days of head-down tilt (HDT) under two conditions: (i) after one bout of maximal supine cycle ergometry completed 24 h prior to performance of ischaemic plantar flexion exercise, and (ii) in a control (no cycle ergometry) condition. Following HDT, peak vascular conductance was reduced in the control condition (0.38 +/- 0.02 to 0.24 +/- 0.02 ml 100 ml-1 min-1 mmHg-1; P = 0.04), but was restored when subjects performed cycle ergometry (0.33 +/- 0.05 to 0.28 +/- 0.04 ml 100 ml-1 min-1 mmHg-1; P = 0.46). After HDT, time to fatigue during ischaemic plantar flexion exercise was not different from pre-HDT 24 h after performance of exhaustive cycle ergometry (120 +/- 24 vs. 122 +/- 19 s), but was decreased in the control condition (116 +/- 11 vs. 95 +/- 8 s; P = 0.07). These data suggest that a single bout of maximal exercise can provide a stimulus to restore peak vascular conductance and maintain time to fatigue during performance of ischaemic plantar flexion exercise.

NASA Discipline Cardiopulmonary↗

Adaptation in a rotating artificial gravity environment

The centripetal force generated by a rotating space vehicle is a potential source of artificial gravity. Minimizing the cost of such a vehicle dictates using the smallest radius and highest rotation rate possible, but head movements made at high rotation rates generate disorienting, nauseogenic cross-coupled semicircular canal stimulation. Early studies suggested 3 or 4 rpm as the highest rate at which humans could adapt to this vestibular stimulus. These studies neglected the concomitant Coriolis force actions on the head/neck system. We assessed non-vestibular Coriolis effects by measuring arm and leg movements made in the center of a rotating room turning at 10 rpm and found that movement endpoints and trajectories are initially deviated; however, subjects readily adapt with 10-20 additional movements, even without seeing their errors. Equilibrium point theories of motor control errantly predict that Coriolis forces will not cause movement endpoint errors so that subjects will not have to adapt their reaching movements during rotation. Adaptation of movement trajectory acquired during Coriolis force perturbations of one arm transfers to the unexposed arm but there is no intermanual transfer of endpoint adaptation indicating that neuromotor representations of movement endpoint and trajectory are separable and can adapt independently, also contradictory to equilibrium point theories. Touching a surface at the end of reaching movements is required for complete endpoint adaptation in darkness but trajectory adapts completely with or without terminal contact. We have also made the first kinematic measurements of unconstrained head movements during rotation, these movements show rapid adaptation to Coriolis force perturbations. Our results point to methods for achieving full compensation for rotation up to 10 rpm. Copyright 1998 Published by Elsevier Science B.V.

Non-NASA Center↗

Mechanisms of cardiac hypertrophy in canine volume overload

This study tested whether the modest hypertrophy that develops in dogs in response to mitral regurgitation is due to a relatively small change in the rate of protein synthesis or, alternatively, is due to a decreased rate of protein degradation. After 3 mo of severe experimental mitral regurgitation, the left ventricular (LV) mass-to-body weight ratio increased by 23% compared with baseline values. This increase in LV mass occurred with a small, but not statistically significant, increase in the fractional rate of myosin heavy chain (MHC) synthesis (Ks), as measured using continuous infusion with [3H]leucine in dogs at 2 wk, 4 wk, and 3 mo after creation of severe mitral regurgitation. Translational efficiency was unaffected by mitral regurgitation as measured by the distribution of MHC mRNA in polysome gradients. Furthermore, there was no detectable increase in translational capacity as measured by either total RNA content or the rate of ribosome formation. These data indicate that translational mechanisms that accelerate the rate of cardiac protein synthesis are not responsive to the stimulus of mitral regurgitation. Most of the growth after mitral regurgitation was accounted for by a decrease in the fractional rate of protein degradation, calculated by subtracting fractional rates of protein accumulation at each time point from the corresponding Ks values. We conclude that 1) volume overload produced by severe mitral regurgitation does not trigger substantial increases in the rate of protein synthesis and 2) the modest increase in LV mass results primarily from a decrease in the rate of protein degradation.

Non-NASA Center↗

Refinement of a limit cycle oscillator model of the effects of light on the human circadian pacemaker

In 1990, Kronauer proposed a mathematical model of the effects of light on the human circadian pacemaker. Although this model predicted many general features of the response of the human circadian pacemaker to light exposure, additional data now available enable us to refine the original model. We first refined the original model by incorporating the results of a dose response curve to light into the model's predicted relationship between light intensity and the strength of the drive onto the pacemaker. Data from three bright light phase resetting experiments were then used to refine the amplitude recovery characteristics of the model. Finally, the model was tested and further refined using data from an extensive phase resetting experiment in which a 3-cycle bright light stimulus was presented against a background of dim light. In order to describe the results of the four resetting experiments, the following major refinements to the original model were necessary: (i) the relationship between light intensity (I) and drive onto the pacemaker was reduced from I1/3 to I0.23 for light levels between 150 and 10,000 lux; (ii) the van der Pol oscillator from the original model was replaced with a higher-order limit cycle oscillator so that amplitude recovery is slower near the singularity and faster near the limit cycle; (iii) a direct effect of light on circadian period (tau x) was incorporated into the model such that as I increases, tau x decreases, which is in accordance with "Aschoff's rule". This refined model generates the following testable predictions: it should be difficult to enhance normal circadian amplitude via bright light; near the critical point of a type 0 phase response curve (PRC) the slope should be steeper than it is in a type 1 PRC; and circadian period measured during forced desynchrony should be directly affected by ambient light intensity.

NASA Discipline Regulatory Physiology↗

Emulating the visual receptive-field properties of MST neurons with a template model of heading estimation

We have proposed previously a computational neural-network model by which the complex patterns of retinal image motion generated during locomotion (optic flow) can be processed by specialized detectors acting as templates for specific instances of self-motion. The detectors in this template model respond to global optic flow by sampling image motion over a large portion of the visual field through networks of local motion sensors with properties similar to those of neurons found in the middle temporal (MT) area of primate extrastriate visual cortex. These detectors, arranged within cortical-like maps, were designed to extract self-translation (heading) and self-rotation, as well as the scene layout (relative distances) ahead of a moving observer. We then postulated that heading from optic flow is directly encoded by individual neurons acting as heading detectors within the medial superior temporal (MST) area. Others have questioned whether individual MST neurons can perform this function because some of their receptive-field properties seem inconsistent with this role. To resolve this issue, we systematically compared MST responses with those of detectors from two different configurations of the model under matched stimulus conditions. We found that the characteristic physiological properties of MST neurons can be explained by the template model. We conclude that MST neurons are well suited to support self-motion estimation via a direct encoding of heading and that the template model provides an explicit set of testable hypotheses that can guide future exploration of MST and adjacent areas within the superior temporal sulcus.

NASA Discipline Neuroscience↗

Human motion perception and smooth eye movements show similar directional biases for elongated apertures

Although numerous studies have examined the relationship between smooth-pursuit eye movements and motion perception, it remains unresolved whether a common motion-processing system subserves both perception and pursuit. To address this question, we simultaneously recorded perceptual direction judgments and the concomitant smooth eye-movement response to a plaid stimulus that we have previously shown generates systematic perceptual errors. We measured the perceptual direction biases psychophysically and the smooth eye-movement direction biases using two methods (standard averaging and oculometric analysis). We found that the perceptual and oculomotor biases were nearly identical, suggesting that pursuit and perception share a critical motion processing stage, perhaps in area MT or MST of extrastriate visual cortex.

NASA Center ARC↗