Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCREENS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Recommended Screening Practices for Launch Collision Aviodance

The objective of this document is to assess the value of launch collision avoidance (COLA) practices and provide recommendations regarding its implementation for NASA robotic missions. The scope of this effort is limited to launch COLA screens against catalog objects that are either spacecraft or debris. No modifications to manned safety COLA practices are considered in this effort. An assessment of the value of launch COLA can be broken down into two fundamental questions: 1) Does collision during launch represent a significant risk to either the payload being launched or the space environment? 2) Can launch collision mitigation be performed in a manner that provides meaningful risk reduction at an acceptable level of operational impact? While it has been possible to piece together partial answers to these questions for some time, the first attempt to comprehensively address them is documented in reference (a), Launch COLA Operations: an Examination of Data Products, Procedures, and Thresholds, Revision A. This report is the product of an extensive study that addressed fundamental technical questions surrounding launch collision avoidance analysis and practice. The results provided in reference (a) will be cited throughout this document as these two questions are addressed. The premise of this assessment is that in order to conclude that launch COLA is a value-added activity, the answer to both of these questions must be affirmative. A "no" answer to either of these questions points toward the conclusion that launch COLA provides little or no risk mitigation benefit. The remainder of this assessment will focus on addressing these two questions.

recommended screening practicies luanch collision ↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

Screening of High Temperature Organic Materials for Future Stirling Convertors

Along with major advancement of Stirling-based convertors, high temperature organics are needed to develop future higher temperature convertors for much improved efficiencies as well as to improve the margin of reliability for the current SOA (State-of-the-Art) convertors. The higher temperature capabilities would improve robustness of the convertors and also allow them to be used in additional missions, particularly ones that require a Venus flyby for a gravity assist. Various organic materials have been employed as essential components in the convertor for their unique properties and functions such as bonding, potting, sealing, thread locking, insulation, and lubrication. The Stirling convertor radioisotope generators have been developed for potential future space applications including Lunar/Mars surface power or a variety of spacecraft and vehicles, especially with a long mission cycle, sometimes up to 17 years, such as deep space exploration. Thus, performance, durability, and reliability of the organics should be critically evaluated in terms of every possible material structure-process-service environment relations based on the potential mission specifications. The initial efforts in screening the high temperature candidates focused on the most susceptible organics, such as adhesive, potting compound, O-ring, shrink tubing, and thread locker materials in conjunction with commercially available materials. More systematic and practical test methodologies that were developed and optimized based on the extensive organic evaluations and validations performed for various Stirling convertor types were employed to determine thermal stability, outgassing, and material compatibility of the selected organic candidates against their functional requirements. Processing and fabrication conditions and procedures were also optimized. This report presents results of the three-step candidate evaluation processes, their application limitations, and the final selection recommendations.

Screening↗

Sandwich ELISA Microarrays: Generating Reliable and Reproducible Assays for High-Throughput Screens

The sandwich ELISA microarray is a powerful screening tool in biomarker discovery and validation due to its ability to simultaneously probe for multiple proteins in a miniaturized assay. The technical challenges of generating and processing the arrays are numerous. However, careful attention to possible pitfalls in the development of your antibody microarray assay can overcome these challenges. In this chapter, we describe in detail the steps that are involved in generating a reliable and reproducible sandwich ELISA microarray assay.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Edge‐Driven Fringe‐Field Effects, Reduced Screening, and Bandgap Widening in Graphene Nanoribbons Enable Single‑Molecule Sensitivity

Graphene nanoribbons (GNRs) offer promising platforms for single‐molecule sensing due to their quasi‐1D channels and discrete electronic states, providing superior sensitivity toward molecular perturbations. While prior studies emphasize smoother edges as essential for optimal performance, the potential benefits of controlled edge roughness remain largely unexplored. Additionally, most investigations focus on GNR arrays, leaving critical edge‐ and width‐dependent factors, including fringe fields, bandgap widening, interactions between adsorbing molecules and GNR atoms, density of states (DOS) suppression, and electrostatic screening lengths, and their collective impact on sensitivity, poorly understood. Here, in this work, we fabricated field‐effect transistors using individual GNRs (widths: 200–20 nm) and characterized their response to molecular adsorption with perfluorooctanoic acid as the model analyte. Narrower ribbons displayed significantly enhanced sensitivity, yielding a coverage‐normalized response of 116 ± 10 mV per molecule in 20 nm‐wide GNRs (from calibrated ensemble Dirac‐point shifts). Experimental and theoretical analyses reveal that this heightened sensitivity arises from stronger fringe fields, width‐dependent quantum confinement effects, reduced DOS, and increased edge roughness that facilitates molecular anchoring, enhanced orbital overlap, and improved charge transfer efficiency. Our findings challenge the conventional assumption that smoother edges inherently enhance sensor performance, demonstrating that controlled edge disorder substantially boosts molecular sensitivity in GNR sensors.

36 MATERIALS SCIENCE↗

Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode

A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen-printed carbon electrode was developed. HRP activities were monitored by square-wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o-aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential-pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 - 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10-15 mol in 25 µL) were obtained with a good precision (RSD = 8%; n = 6). This rapid and sensitive HRP assay with microliters-assay volume could be readily integrated to portable devices and point-of-care (POC) diagnosis applications.

59 BASIC BIOLOGICAL SCIENCES↗

High‐throughput screening of aqueous biphasic systems with ionic liquids as additives for extraction and purification of enveloped virus‐like particles

Due to their unique properties, virus‐like particles (VLPs) have been portrayed as a promising high‐value biopharmaceutical in VLP‐based vaccination and cancer therapy. Nevertheless, due to limited physical and economical capabilities of the current downstream processing of VLPs, their production is still difficult and seen as a major problem that needs to be tackled. In this work, high‐throughput screening on a liquid handling station (LHS) has been implemented for efficient selection of adequate polymer‐salt aqueous biphasic systems (ABS) for extraction and purification of enveloped Hepatitis C virus pseudoparticles (HCVpp). The effect of polyethylene glycol (PEG) molecular weight and salt type (citrate, sulfate, and phosphate) was first evaluated. Furthermore, to optimize extraction parameters, the effect of pH and tie‐line lengths (TLL) was also addressed. For the most promising ABS and extraction conditions, the addition of ten ionic liquids (ILs) as adjuvants was investigated. Insights on the chemical features of ILs that impact HCV‐VLPs partitioning are highlighted. Finally, the potential of studied ABS containing ILs as adjuvants in the extraction and purification of VLPs from cell culture supernatants was addressed. The 100% extraction efficiency of VLPs in the PEG‐rich phase was achieved, and VLP purity was increased compared to the system without IL. In conclusion, these promising results show that ILs can be very effective in modulating the phase properties of polymer‐salt ABS, achieving high HCV‐VLP purification.

Marchel, Mateusz↗

SSC: A Tool for Constructing Libraries for Systematic Screening of Conformers

Even a relatively small molecule with 10–20 atoms might have a few local minima, which correspond to different conformers. The number of local minima quickly increases with molecular size and the most common algorithms, driven by calculated forces, frequently identify a minimum, which is closest to the initial structure, rather than the most stable conformer. Here we discuss how to perform a systematic search of the conformational space for a chain-like molecule. Our approach is fully automated and a user has control which chemical bonds will be probed and with which increments. Moreover, whole fragments of the molecule, which are adjacent to each selected rotational bond, are rotated in a properly selected cylindrical coordinate system and unchemical hybridizations and some ‘‘clashes’’ between neighboring groups, which are common when standard Z-matrices are used, are avoided. A library of potentially relevant conformers is created with a tool, which we call SSC, denoting Systematic Screening of Conformers. Each member of the library is prescreened at a predefined level of theory and the most promising conformers are identified. Finally, they are further evaluated at a higher level of theory to identify the most stable structures and their physicochemical properties. As an example, we demonstrate the results of this approach for 2'-deoxycytidine.

43 PARTICLE ACCELERATORS↗