Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Rare Nonleptonic Decays of the Omega Hyperon: Measurements of the Branching Ratios for Ω ∓ --> Ξ$*0\atop{(1530)}$ (anti-Ξ$*0\atop{(1530)}$) π ∓ and Ω ∓ → Ξ ∓ π ± π ∓

A clean signal of 78 (24) events has been observed in the rare nonleptonic particle (antiparticle) decay modes Ω ∓ → Ξ ∓ π ± π ∓ using data collected with the HyperCP spectrometer during Fermilab's 1999 fixed-target run. We obtain B(Ω - → Ξ - π + π - ) = [4.32 ± 0.56(stat) ± 0.28(syst)] x 10 -4 and B(Ω + → Ξ + π - π + ) = 3.13 ± 0.71(stat) ± 0.20(syst) x 10 -4 . This is the first observation of the antiparticle mode. Our measurement for the particle mode agrees with the previous experimental result and has an order-of-magnitude better precision. We extract the contribution from the resonance decay mode Ω ∓ → Ξ$*0\atop{(1530)}$ (Ξ$*0\atop{(1530)}$)π ∓ to the final state Ξ ∓ π ± π ∓ . This the first actual measurement of the resonance-mode branching ratios, gives B(Ω - → Ξ$*0\atop{(1530)}$ π - ) = [4.55 ± 2.33(stat) ± 0.38(syst)] x 10 -5 , B(Ω + → Ξ$*0\atop{(1530)}$π + ) = [1.40 ± 2.83(stat) ± 0.12(syst)] x 10 -5 and disagrees with the current Particle Data Group review value, being ~ 14 times smaller. Since the central value of the resonance-mode branching ratio is less than two standard deviations away from zero, we also calculate branching ratio upper limits at 90% confidence level: B(Ω - → Ξ$*0\atop{(1530)}$ π - ) < 7.61 x 10 -5 and B(Ω + → Ξ$*0\atop{(1530)}$ π + ) < 5.61 x 10 -5 . This analysis provides new data on nonleptonic hyperon decays which allows studies of how weak interaction processes occur in the presence of strong interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First measurement of the B$0\atop{2}$ semileptonic branching ratio to an orbitally excited d$**\atop{s}$ state, Br(B$0\atop{2}$ → D$-\atop{s1}$(2536)μ + vX)

In a data sample of approximately 1.3 fb -1 collected with the D0 detector between 2002 and 2006, the orbitally excited charm state D$±\atop{s1}$(2536)has been observed with a measured mass of 2535.7 ± 0.6(stat) ± 0.5(syst) MeV/c 2 via the decay mode B$0\atop{s}$ → D$-\atop{s1}$(2536)μ + vX followed by D$±\atop{s1}$(2536) → D *± K$0\atop{S}$. By normalizing to the known branching ratio Br($\bar{b}$ → D* - μ + vX) and to the number of reconstructed D* mesons with an associated identified muon, a first-ever measurement is made of the product branching ratio ($\bar{b}$ →} D$-\atop{s1}$(2536)μ + vX) • Br(D$-\atop{s1}$ → D* - K$0\atop{S}$). Assuming that D$-\atop{s1}$(2536) production in semileptonic decay is entirely from B$0\atop{s}$, an extraction of the semileptonic branching ratio Br(B$0\atop{s}$ → D$-\atop{s1}$(2536)μ + vX) is made. Comparisons are made with theoretical expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report on Isotope Ratio Techniques for Light Water Reactors

The Isotope Ratio Method (IRM) is a technique for estimating the energy or plutonium production in a fission reactor by measuring isotope ratios in non-fuel reactor components. The isotope ratios in these components can then be directly related to the cumulative energy production with standard reactor modeling methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar Records: The Wolf Sunspot Index and Umbral/Penumbral Ratio

These data from observations of sunspot activity cover the period 1875 through 1981; reconstructions are possible back to 1832. Available sunspot models and the theory of mixing length indicate that the observed changes in the umbral/penumbral (U/P) ratio may be equivalent to changes in the solar constant. The U/P ratio is calculated from measurements of solar activity and has been shown to be in good agreement with the Northern Hemisphere temperature record. The data consist of year, number of sunspot groups, Wolf sunspot number, umbra area, whole area, penumbral area, and umbral/penumbral ratio. The data are in one file (3.3 kB).For access to the data files, click this link to the CDIAC data transition website: http://cdiac.ess-dive.lbl.gov/ndps/ndp014.html

54 ENVIRONMENTAL SCIENCES↗

Constraint on a cosmological variation in the proton-to-electron mass ratio from electronic co absorption

Carbon monoxide (CO) absorption in the sub-damped Lyα absorber at redshift z{sub abs}≃2.69 toward the background quasar SDSS J123714.60+064759.5 (J1237+0647) was investigated for the first time in order to search for a possible variation of the proton-to-electron mass ratio, μ, over a cosmological timescale. The observations were performed with the Very Large Telescope/Ultraviolet and Visual Echelle Spectrograph with a signal-to-noise ratio of 40 per 2.5 km s{sup −1} per pixel at ∼5000 Å. Thirteen CO vibrational bands in this absorber are detected: the A{sup 1}Π − X{sup 1}Σ{sup +} (ν{sup ′}, 0) for ν{sup ′}=0--8, B{sup 1}Σ{sup +} − X{sup 1}Σ{sup +} (0, 0), C{sup 1}Σ{sup +} − X{sup 1}Σ{sup +} (0, 0), and E{sup 1}Π − X{sup 1}Σ{sup +} (0, 0) singlet–singlet bands and the d{sup 3}Δ − X{sup 1}Σ{sup +} (5, 0) singlet–triplet band. An updated database including the most precise molecular inputs needed for a μ-variation analysis is presented for rotational levels J = 0–5, consisting of transition wavelengths, oscillator strengths, natural lifetime damping parameters, and sensitivity coefficients to a variation of the proton-to-electron mass ratio. A comprehensive fitting method was used to fit all the CO bands at once and an independent constraint of Δμ/μ=(0.7±1.6{sub stat}±0.5{sub syst})×10{sup −5} was derived from CO only. A combined analysis using both molecular hydrogen and CO in the same J1237+0647 absorber returned a final constraint on the relative variation of Δμ/μ=(−5.6±5.6{sub stat}±3.1{sub syst})×10{sup −6}, which is consistent with no variation over a look-back time of ∼11.4 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

C/O and Mg/Si ratios of stars in the solar neighborhood

The carbon-to-oxygen ratio in a protoplanetary disk can have a dramatic influence on the compositions of any terrestrial planets formed. In regions of high C/O, planets form primarily from carbonates, and in regions of low C/O, the ratio of magnesium to silicon determines the types of silicates that dominate the compositions. We present C/O and Mg/Si ratios for 852 F, G, and K dwarfs in the solar neighborhood. We find that the frequency of carbon-rich dwarfs in the solar neighborhood is <0.13% and that 156 known planet hosts in the sample follow a similar distribution as all of the stars as a whole. The cosmic distribution of Mg/Si for these same stars is broader than the C/O distribution and peaks near 1.0, with ∼60% of systems having 1 ⩽ Mg/Si < 2, leading to rocky planet compositions similar to the Earth. This leaves 40% of systems that can have planets that are silicate-rich and that may have very different compositions than our own.

79 ASTRONOMY AND ASTROPHYSICS↗

New detections of HNC in planetary nebulae: evolution of the [HCN]/[HNC] ratio

New detections of HNC have been made toward 11 planetary nebulae (PNe), including K4-47, K3-58, K3-17, M3-28, and M4-14. These sources, which represent a wide range of ages and morphologies, had previously been observed in HCN by Schmidt and Ziurys. Measurements of the J=1→0 and J=3→2 transitions of HNC near 90 and 271 GHz were conducted using the new 12 m and the Sub-Millimeter Telescope of the Arizona Radio Observatory. HCN and HNC were also identified via their J=1→0 lines toward eight positions across the Helix Nebula (NGC 7293). Column densities for HNC, determined from radiative transfer modeling, were N{sub tot}(HNC) ∼ (0.06–4.0) × 10{sup 13} cm{sup −2}, corresponding to fractional abundances with respect to H{sub 2} of f ∼ (0.02–1.4) × 10{sup −7}. The HCN and HNC column densities across the Helix were found to be N{sub tot}(HCN) ∼ (0.2–2.4) × 10{sup 12} cm{sup −2} and N{sub tot}(HNC) ∼ (0.07–1.6) × 10{sup 12} cm{sup −2}, with fractional abundances of (0.2–3.2) × 10{sup −7} and (0.09–2.2) × 10{sup −7}. The [HCN]/[HNC] ratio varied between ∼1–8 for all PNe, with [HCN]/[HNC] ∼1–4 across the Helix. These values are greatly reduced from what has been found in asymptotic giant branch stars, where the ratio is typically >100. Both the abundance of HNC and the [HCN]/[HNC] ratio do not appear to vary significantly with nebular age across a time span of ∼10,000 years, in contrast to predictions of chemical models. The increase in HNC appears to arise in the proto-planetary stage, but becomes “frozen” once the PN phase is reached.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio.

Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of {sup 14}C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of {sup 14}C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the {sup 14}C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with {sup 14}C corresponds to 30 fg equivalents. AMS provides an sensitive, accurate and precise method of measuring drug compounds in biological matrices.

07 ISOTOPE AND RADIATION SOURCES↗

Variable Lidar Ratios for Marine and Dusty Marine Using MODIS AOD Constrained Retrievals and GOCART Model Simulations and their Impact on Level 2 CALIPSO Data Products in Version 5

The Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) onboard CALIPSO provided global measurements of attenuated backscatter profiles of various tropospheric aerosol species from June 2006 through June 2023. Extinction profiles are retrieved from these backscatter measurements by assuming a value for the extinction-to-backscatter or lidar ratio (LR). Up until version V4.51 of the data products, only a constant global value for each of the species has been used, spatially and temporally. However, it has been well known from various ground-based measurements that LRs of each aerosol species can potentially vary spatially as well seasonally. For the forthcoming Version 5 of the CALIPSO products, the CALIPSO team will implement variable lidar ratios at 532 nm for the species classified as “marine” and “dusty marine”. Here we present the essential elements of this scheme, which involves estimating lidar ratios by constraining Fernald solutions for the CALIOP particulate backscatter profiles using aerosol optical depths (AOD) from collocated MODIS retrievals. To account for the lack of measurements in various regions and seasons (e.g., Arctic winters), we leverage collocated model sea-salt volume fractions (SSVF) simulated by the Goddard Chemistry Aerosol Radiation and Transport (GOCART) model and use an empirical relationship between the SSVF and LR to build hybrid climatological maps for the entire globe, i.e., using the modelled values when reliable values of the constrained LRs are not available. Initial evaluation of the resulting extinction profiles and corresponding AODs, both globally and in specific regions are presented using a limited amount of data. The primary improvement in AOD occurs in the coastal areas, like the Arabian Sea and Bay of Bengal. The estimated marine LR values in these regions are significantly higher than the constant value of 23 sr used in previous data releases, likely due to mixing with offshore pollution which results in higher AODs. Initial validation results using the CALIPSO Ocean Derived Column Optical Depth (ODCOD) retrievals and ground-based AERONET AOD measurements are presented.

CALIPSO↗

Accurate determination of Curium and Californium isotopic ratios by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) in 248Cm samples for transmutation studies

The French Atomic Energy Commission has carried out several experiments including the mini-INCA (INcineration of Actinides) project for the study of minor-actinide transmutation processes in high intensity thermal neutron fluxes, in view of proposing solutions to reduce the radiotoxicity of long-lived nuclear wastes. In this context, a Cm sample enriched in {sup 248}Cm ({approx}97 %) was irradiated in thermal neutron flux at the High Flux Reactor (HFR) of the Laue-Langevin Institute (ILL). This work describes a quadrupole ICP-MS (ICP-QMS) analytical procedure for precise and accurate isotopic composition determination of Cm before sample irradiation and of Cm and Cf after sample irradiation. The factors that affect the accuracy and reproducibility of isotopic ratio measurements by ICP-QMS, such as peak centre correction, detector dead time, mass bias, abundance sensitivity and hydrides formation, instrumental background, and memory blank were carefully evaluated and corrected. Uncertainties of the isotopic ratios, taking into account internal precision of isotope ratio measurements, peak tailing, and hydrides formations ranged from 0.3% to 1.3%. This uncertainties range is quite acceptable for the nuclear data to be used in transmutation studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

241Am (n,gamma) isomer ratio measurement

The objective of this project is to improve the accuracy of the {sup 242}Cm/{sup 241}Am radiochemistry ratio. We have performed an activation experiment to measure the {sup 241}Am(n,{gamma}) cross section leading to either the ground state of {sup 242g}Am (t{sub 1/2} = 16 hr) which decays to {sup 242}Cm (t{sub 1/2} = 163 d) or the long-lived isomer {sup 242m}Am (t{sub 1/2} = 141 yr). This experiment will develop a new set of americium cross section evaluations that can be used with a measured {sup 242}Cm/{sup 241}Am radiochemical measurement for nuclear forensic purposes. This measurement is necessary to interpret the {sup 242}Cm/{sup 241}Am ratio because a good measurement of this neutron capture isomer ratio for {sup 241}Am does not exist. The targets were prepared in 2007 from {sup 241}Am purified from LANL stocks. Gold was added to the purified {sup 241}Am as an internal neutron fluence monitor. These targets were placed into a holder, packaged, and shipped to Forschungszentrum Karlsruhe, where they were irradiated at their Van de Graff facility in February 2008. One target was irradiated with {approx}25 keV quasimonoenergetic neutrons produced by the {sup 7}Li(p,n) reaction for 3 days and a second target was also irradiated for 3 days with {approx}500 keV neutrons. Because it will be necessary to separate the {sup 242}Cm from the {sup 241}Am in order to measure the amount of {sup 242}Cm by alpha spectrometry, research into methods for americium/curium separations were conducted concurrently. We found that anion exchange chromatography in methanol/nitric acid solutions produced good separations that could be completed in one day resulting in a sample with no residue. The samples were returned from Germany in July 2009 and were counted by gamma spectrometry. Chemical separations have commenced on the blank sample. Each sample will be spiked with {sup 244}Cm, dissolved and digested in nitric acid solutions. One third of each sample will be processed at a time. First, the gold will be removed by anion exchange chromatography. Then the {sup 242}Cm will be separated from the {sup 241}Am using the methanol/nitric acid anion exchange method. When a sufficient separation has been achieved, a deposit will be prepared and the {sup 242}Cm will be counted by alpha spectrometry. The purified {sup 241}Am fraction containing the long lived {sup 242m}Am will be allowed to decay into {sup 242}Cm for a period of {approx}6 months. After this time, the americium/curium separations will be repeated and the {sup 242}Cm that has grown in will be counted by alpha spectrometry. At the conclusion of the experiment, we will have cross section measurements for {sup 241}Am (n,{gamma}) {sup 242g}Am and {sup 241}Am (n,V) {sup 242m}Am at two energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

TSPR: The Total System Performance Ratio as a Metric for HVAC System Efficiency

North American energy codes do not typically discriminate between high-performing and poorly-performing HVAC system types, thereby perpetuating the installation of systems with high energy consumption and carbon emissions. The problem is compounded in the US by federal preemption rules, prohibiting state and local energy codes from mandating more efficient equipment than is defined in federal standards. The lack of a total system efficiency metric for HVAC effectively blocks an eventual transition to a performance-based code structure. To surmount this problem, the City of Seattle and Pacific Northwest National Laboratory have developed the Total System Performance Ratio (TSPR) as a proposed amendment to the 2018 Washington State Energy Code. The TSPR is a ratio that compares the annual space heating and cooling load of a building to the annual energy consumed by the building’s entire HVAC system. In the TSPR, target ratios for several building types are calculated in relation to those of the HVAC systems judged to be the most appropriate for each building type. Installation of the lowest-performing HVAC system types will be severely constrained, while exceptional design flexibility will still be provided. With financial support from an international nonprofit, a calculation software tool has been developed as a module of the US DOE Asset Score tool, using simplified building energy modeling. Taken together with whole-system evaluation options for lighting and building envelope systems, a whole-system HVAC performance evaluation would create a path for a transition away from prescriptive-based and towards performance-based codes.

Total System Performance Ratio, Performanced Based↗

Generalized gamma-ray isotopic analysis software and re-evaluation of the two important 242Pu branching ratios

The goal of the generalized gamma-ray analysis software is to provide precise and accurate isotopic analyses of samples that do not have a standard experimental geometry. This analysis tool will analyze gamma-ray data from all types of measurement scenarios with little or no interaction from the user. This tool also provides complete transparency regarding the gamma-ray peaks and branching intensities used in the analysis with the capability for the user to modify this information. They are currently at the data collected phase of building a validated spectral library. One of the by-products in this data collection phase is enabling them to reevaluate the two important branching ratios in {sup 242}Pu. These branching ratios are required for very high burn-up plutonium fuels. The preliminary analysis shows that the energy of the states are 103.5 keV and 158.82 keV, the branching ratio are 1.36E-5 (9%) and 3.37E-6(7%), respectively. More accurate measurements and analysis are currently being carried out.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Earthquake stress via event ratio levels: Application to the 2011 and 2016 Oklahoma seismic sequences

Abstract We develop a new methodology for determining earthquake stress drop and apparent stress values via spectral ratio asymptotic levels. With sufficient bandwidth, the stress ratio for a pair of events can be directly related to these low‐ and high‐frequency levels. This avoids the need to assume a particular spectral model and derive stress drop from cubed corner frequency measures. The method can be applied to spectral ratios for any pair of closely related earthquakes and is particularly well suited for coda envelope methods that provide good azimuthally averaged, point‐source measures. We apply the new method to the 2011 Prague and 2016 Pawnee earthquake sequences in Oklahoma. The sequences show stress scaling with size and depth, with the largest events having apparent stress levels near 1 MPa and smaller and/or shallower events having systematically lower stress values.

58 GEOSCIENCES↗

Electrochemical Conversion of CO 2 to Syngas with Controllable CO/H 2 Ratios over Co and Ni Single-Atom Catalysts

The electrochemical CO 2 reduction reaction (CO 2 RR) to yield synthesis gas (syngas, CO and H 2 ) has been considered as a promising method to realize the net reduction in CO 2 emission. However, it is challenging to balance the CO 2 RR activity and the CO/H 2 ratio. To address this issue, nitrogen-doped carbon supported single-atom catalysts are designed as electrocatalysts to produce syngas from CO 2 RR. While Co and Ni single-atom catalysts are selective in producing H2 and CO, respectively, electrocatalysts containing both Co and Ni show a high syngas evolution (total current 74 mA cm -2 ) with CO/H 2 ratios (0.23-2.26) that are suitable for typical downstream thermochemical reactions. Density functional theory calculations provide insights into the key intermediates on Co and Ni single-atom configurations for the H 2 and CO evolution. The results present a useful case on how non-precious transition metal species can maintain high CO 2 RR activity with tunable CO/H 2 ratios.

25 ENERGY STORAGE↗

High-moisture pelleting of corn stover using pilot- and commercial-scale systems: Impact of moisture content, L / D ratio and hammer mill screen size on pellet quality and energy consumption

Here, high-moisture pelleting of corn stover was tested in pilot- and commercial-scale systems. For the pilot-scale study, a 6.35 mm screen size hammer mill ground corn stover was reconditioned to moisture between 14 and 29.6% (w.b.), and 5, 7 and 9 L/D ratio pellet die were used. At 29% corn stover moisture content and L/D ratios of 5 and 9, the bulk density and durability of the pellets were ≤450 kg/m 3 and <90% and >540 kg/m 3 and >90%, respectively. Increasing the feedstock moisture and L/D ratio increased the pelleting energy. Increasing the hammer mill screen size to 11.11 mm reduced the bulk density but not the durability. The response surface models adequately described the pelleting process (R 2 ≥ 0.88), and analysis of variance showed a strong interaction between the process variables and pellet properties. Commercial-scale testing of high-moisture pelleting using 6.35 mm ground corn stover bales in the moisture range 24–26% (w.b.) produced pellets with a density of >675 kg/m 3 and durability of >98%, whereas increasing the hammer mill screen size to 11.11 mm reduced the bulk density by about 100 kg/m 3 but not the durability. The energy consumption of the commercial-scale unit operations for the high-moisture pelleting process was in the range 98–124 kW h/ton, which is 64–72% less energy than conventional pelleting that requires energy about 350 kW h/ton for biomass drying from 30% (w.b.) to 10% (w.b.) moisture content before pelleting. Pellets produced using high-moisture pelleting met International Organization for Standardization and Pellets Fuel Institute international standards. Published 2023. This article is a U.S. Government work and is in the public domain in the USA.

09 BIOMASS FUELS↗

Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All-Faraday Detector Configuration on the Neoma MC-ICP-MS

Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the ratio of the production cross sections times branching fractions of $B_{c}^{\pm} \to J/\psi \pi^{\pm}$ and $B^{\pm} \to J/\psi K^{\pm}$ and $\mathcal{B}(B_{c}^{\pm} \to J/\psi \pi^{\pm}\pi^{\pm}\pi^{\mp})/\mathcal{B}(B_{c}^{\pm} \to J/\psi \pi^{\pm})$ in pp collisions at $\sqrt{s} =$ 7 TeV

The ratio of the production cross sections times branching fractions (σ(B ± c )B(B ± c →J/ψπ ± ))/(σ(B ± )B(B ± →J/ψK ± )) is studied in proton-proton collisions at a center of-mass energy of 7 TeV with the CMS detector at the LHC. The kinematic region investigated requires B c ± and B ± mesons with transverse momentum p T > 15 GeV and rapidity |y|< 1.6. The data sample corresponds to an integrated luminosity of 5.1 fb -1 . The ratio is determined to be [0.48±0.05(stat)± 0.03(syst)±0.05 (τBc)]%. The B c ± → J/ψπ ± π ± π ∓ decay is also observed in the same data sample. Using a model-independent method developed to measure the efficiency given the presence of resonant behaviour in the three-pion system, the ratio of the branching fractions B(B ± c →J/ψπ ± π ± π ∓ )/B(B ± c →J/ψπ ± ) is measured to be 2.55±0.80(stat)±0.33(syst) +0.04 -0.01 (τ Bc ), consistent with the previous LHCb result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗