Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Space Radiation Shielding Studies for Astronaut and Electronic Component Risk Assessment

The dosimetry component of the Center for Radiation Engineering and Science for Space Exploration (CRESSE) will design, develop and characterize the response of a suite of radiation detectors and supporting instrumentation and electronics with three primary goals that will: (1) Use established space radiation detection systems to characterize the primary and secondary radiation fields existing in the experimental test-bed zones during exposures at particle accelerator facilities. (2) Characterize the responses of newly developed space radiation detection systems in the experimental test-bed zones during exposures at particle accelerator facilities, and (3) Provide CRESSE collaborators with detailed dosimetry information in experimental test-bed zones.

Fuchs, Jordan Robert↗

The influence of the field setup on the dosimetry of abutted fields in single-isocenter half-beam techniques

Purpose: To study the influence of the field setup on the dosimetry at the junction in single-isocenter half-beam techniques. Methods: The dosimetry at the junction for a two-field setup with the gantry at zero was first evaluated with radiochromic films. A three-field setup, with an anterior field and two opposed lateral fields, was also analyzed for two different relative positions of the fields involved. In all cases, the dose increase at the central axis, called the junction dose, was measured. Results: Junction doses varied greatly with the setup. For the three-field setup, the junction dose differed from that obtained with the two-field setup, and it greatly depended on the relative position of the fields. When the anterior field was closer to the gantry than the lateral fields, a field gap occurred and the junction dose was negative. When the anterior field was farther from the gantry than the lateral fields, a field overlap was obtained and the junction dose was positive. The difference in the junction dose between the three-field setups was around 18% for the three accelerators evaluated. Conclusions: Having a uniform dose distribution for two fields at gantry 0 deg. does not guarantee a uniform distribution at other gantry angles. Junction doses are largely affected by the relative position of the radiation fields, which may have an impact in clinical practice. Therefore, any method aiming to assess or to optimize the dose homogeneity at the junction should take this effect into account.

60 APPLIED LIFE SCIENCES↗

TeV neutrinos from accreting x-ray pulsars

Pulsars inside binary systems can accrete matter that arrives up to the pulsar surface provided that its period is long enough. During the accretion process, matter has to be accelerated to the rotational velocity of the pulsar magnetosphere at the distance where the balance between the pressure of matter and the magnetic field is achieved. At this distance, a very turbulent and magnetized region is formed in which hadrons can be accelerated to relativistic energies. These hadrons can interact with the very strong radiation field coming from the hot polar cap on the neutron star surface created by the in-falling matter. We calculate the neutrino event rates produced in a km{sup 2} detector that can be expected from accreting millisecond and classical x-ray pulsars at a typical distance within our own Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-382: Influence of Compton Currents On Profile Measurements in Small- Volume Ion Chambers

Purpose: Ionization chambers in electron radiation fields are known to exhibit polarity effects due to Compton currents. Previously we have presented a unique manifestation of this effect observed with a microionization chamber. We have expanded that investigation to include three micro-ionization chambers commonly used in radiation therapy. The purpose of this project is to determine what factors influence this polarity effect for micro-chambers and how it might be mitigated. Methods: Three chambers were utilized: a PTW 31016, an Exradin A-16, and an Exradin A- 26. Beam profile scans were obtained on a Varian TrueBeam linear accelerator in combination with a Wellhofer water phantom for 6, 9, and 12 MeV electrons. Profiles were obtained parallel and perpendicular to the chamber's long axis, with both positive and negative collecting bias. Profiles were obtained with various chamber components shielded by 5 mm of Pb at 6 MeV to determine their relative contributions to this polarity effect. Results: The polarity effect was observed for all three chambers, and the ratio of the polarity effect for the Exradin chambers is proportional to the ratio of chamber volumes. Shielding the stem of both Exradin chambers diminished, but did not remove the polarity effect. However, they demonstrated no out-of-field effect when the cable was shielded with Pb. The PTW chamber demonstrated a significantly reduced polarity effect without any shielding despite its comparable volume with the A-26. Conclusions: The sensitive volume of these micro-chambers is relatively insensitive to collecting polarity. However, charge deposition within the cable can dramatically alter measured ionization profiles. This is demonstrated by the removal of the out-of-field ionization when the cable is shielded for the Exradin chambers. We strongly recommend analyzing any polarity dependence for small-volume chambers used in characterization of electron fields.

07 ISOTOPE AND RADIATION SOURCES↗

THE INTERSTELLAR MAGNETIC FIELD CLOSE TO THE SUN. II

The magnetic field in the local interstellar medium (ISM) provides a key indicator of the galactic environment of the Sun and influences the shape of the heliosphere. We have studied the interstellar magnetic field (ISMF) in the solar vicinity using polarized starlight for stars within 40 pc of the Sun and 90 Degree-Sign of the heliosphere nose. In Frisch et al. (Paper I), we developed a method for determining the local ISMF direction by finding the best match to a group of interstellar polarization position angles obtained toward nearby stars, based on the assumption that the polarization is parallel to the ISMF. In this paper, we extend the analysis by utilizing weighted fits to the position angles and by including new observations acquired for this study. We find that the local ISMF is pointed toward the galactic coordinates l, b =47 Degree-Sign {+-} 20 Degree-Sign , 25 Degree-Sign {+-} 20 Degree-Sign . This direction is close to the direction of the ISMF that shapes the heliosphere, l, b =33 Degree-Sign {+-} 4 Degree-Sign , 55 Degree-Sign {+-} 4 Degree-Sign , as traced by the center of the 'Ribbon' of energetic neutral atoms discovered by the Interstellar Boundary Explorer (IBEX) mission. Both the magnetic field direction and the kinematics of the local ISM are consistent with a scenario where the local ISM is a fragment of the Loop I superbubble. A nearby ordered component of the local ISMF has been identified in the region l Almost-Equal-To 0 Degree-Sign {yields} 80 Degree-Sign and b Almost-Equal-To 0 Degree-Sign {yields} 30 Degree-Sign , where PlanetPol data show a distance-dependent increase of polarization strength. The ordered component extends to within 8 pc of the Sun and implies a weak curvature in the nearby ISMF of {approx}0.{sup 0}25 pc{sup -1}. This conclusion is conditioned on the small sample of stars available for defining this rotation. Variations from the ordered component suggest a turbulent component of {approx}23 Degree-Sign . The ordered component and standard relations between polarization, color excess, and H{sup o} column density predict a reasonable increase of N(H) with distance in the local ISM. The similarity of the ISMF directions traced by the polarizations, the IBEX Ribbon, and pulsars inside the Local Bubble in the third galactic quadrant suggest that the ISMF is relatively uniform over spatial scales of 8-200 pc and is more similar to interarm than spiral-arm magnetic fields. The ISMF direction from the polarization data is also consistent with small-scale spatial asymmetries detected in GeV-TeV cosmic rays with a galactic origin. The peculiar geometrical relation found earlier between the cosmic microwave background dipole moment, the heliosphere nose, and the ISMF direction is supported by this study. The interstellar radiation field at {approx}975 A does not appear to play a role in grain alignment for the low-density ISM studied here.

79 ASTRONOMY AND ASTROPHYSICS↗

Patterns of Failure in Pediatric Rhabdomyosarcoma After Proton Therapy

Purpose: To report on the patterns of failure in children with rhabdomyosarcoma treated with proton therapy. Patients and Methods: Between February 2007 and November 2013, 66 children with a median age of 4.1 years (range, 0.6-15.3 years) diagnosed with nonmetastatic rhabdomyosarcoma were treated with proton therapy. Clinical target volume 1 was defined as the prechemotherapy tumor plus a 1-cm anatomically constrained margin. Clinical target volume 2 was defined as the postchemotherapy tumor (or tumor bed) plus a 0.5-cm anatomically constrained margin, further expanded to encompass potential pathways of spread, including soft tissue infiltrated with tumor at diagnosis. Results: Of the 66 children, 11 developed locally progressive disease at a median of 16 months (range, 14-32 months), for an actuarial 2-year local control rate of 88%. Among the children who progressed, median age and tumor size at diagnosis were 6.7 years (range, 0.6-16 years) and 6 cm (range, 2-8 cm), respectively. Of the recurrences, 64% and 36% were embryonal and alveolar, respectively. Disease progression was observed in 7 (64%) parameningeal, 2 (18%) head and neck (other), and 2 (18%) bladder/prostate subsites. At diagnosis, 8 of 11 patients who developed a recurrence were Intergroup Rhabdomyosarcoma Study stage 3, and all 11 were group III. Of the relapses, 100% (11 of 11) were confirmed as in-field within the composite 95% isodose line. One of the 11 patients (9%) developed a new simultaneous regional nodal recurrence outside of the previously treated radiation field. Conclusion: Early data suggest that the sharp dosimetric gradient associated with proton therapy is not associated with an increased risk of marginal failure. Routine use of a 0.5- to 1-cm clinical target volume 1/2 margin with highly conformal proton therapy does not compromise local control in children diagnosed with rhabdomyosarcoma with unfavorable risk features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

THE EFFECTS OF X-RAY FEEDBACK FROM ACTIVE GALACTIC NUCLEI ON HOST GALAXY EVOLUTION

Hydrodynamic simulations of galaxies with active galactic nuclei (AGNs) have typically employed feedback that is purely local, i.e., an injection of energy to the immediate neighborhood of the black hole (BH). We perform GADGET-2 simulations of massive elliptical galaxies with an additional feedback component: an observationally calibrated X-ray radiation field which emanates from the BH and heats gas out to large radii from the galaxy center. We find that including the heating and radiation pressure associated with this X-ray flux in our simulations enhances the effects which are commonly reported from AGN feedback. This new feedback model is twice as effective as traditional feedback at suppressing star formation, produces three times less star formation in the last 6 Gyr, and modestly lowers the final BH mass (30%). It is also significantly more effective than an X-ray background in reducing the number of satellite galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Supersonic Jet Noise Reductions Predicted With Increased Jet Spreading Rate

In this paper, predictions are made of noise radiation from single, supersonic, axisymmetric jets. We examine the effects of changes in operating conditions and the effects of simulated enhanced mixing that would increase the spreading rate of jet shear layer on radiated noise levels. The radiated noise in the downstream direction is dominated by mixing noise and, at higher speeds, it is well described by the instability wave noise radiation model. Further analysis with the model shows a relationship between changes in spreading rate due to enhanced mixing and changes in the far field radiated peak noise levels. The calculations predict that enhanced jet spreading results in a reduction of the radiated peak noise level.

Dahl, Milo D.↗

Ground-based simulations of cosmic ray heavy ion interactions in spacecraft and planetary habitat shielding materials

This paper surveys some recent accelerator-based measurements of the nuclear fragmentation of high energy nuclei in shielding and tissue-equivalent materials. These data are needed to make accurate predictions of the radiation field produced at depth in spacecraft and planetary habitat shielding materials and in the human body by heavy charged particles in the galactic cosmic radiation. Projectile-target combinations include 1 GeV/nucleon 56Fe incident on aluminum and graphite and 600 MeV/nucleon 56Fe and 290 MeV/nucleon 12C on polyethylene. We present examples of the dependence of fragmentation on material type and thickness, of a comparison between data and a fragmentation model, and of multiple fragments produced along the beam axis.

NASA Discipline Radiation Health↗

Transamericium Radiation-Induced Redox Chemistry

The actinide series boasts many unique physical and chemical features worthy of study. However, the chemical influence of their inherent radiation field is often overlooked, especially as we begin to explore the late actinides (transamericium) in more detail than ever possible before. - Absorption of ionizing radiation induces the formation of a variety of transient and steady-state radicals, ions, and molecular degradation products. Many of these radiolysis products are strongly redox active and exhibit significant reactivity with a number of actinides, e.g., neptunium and americium. Here we present results from the first-ever time-resolved picosecond pulsed electron radiolysis measurements for the reaction of the late actinides (curium and californium) with reactive transients pertinent to actinide manipulations in aqueous solution, i.e., the hydrated electron (eaq–), the hydrogen atom (H•), and hydroxyl (•OH) and nitrate (•NO3) radicals.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Unravelling the radiation-induced redox chemistry of plutonium ions in aqueous solution

Plutonium plays a critical role in nuclear fuel cycle technologies, but our understanding of its fundamental radiation-induced redox chemistry is limited. Changes in oxidation states affect the speciation and transport of plutonium ions in solution. For example, solvent extraction techniques used to separate and recover plutonium from used nuclear fuel rely on the selective formation, maintenance, and complexation of specific plutonium oxidation states. However, radiolytically generated radicals, ions, and molecules can drive the oxidation state distribution of plutonium ions far from equilibrium, ultimately changing the physical and chemical properties of the bulk system. These radiation-induced processes are inevitable due to the ionizing radiation fields generated by the radioactive decay of plutonium and its daughter nuclides. Therefore, mechanistically understanding how plutonium's various oxidation states respond to ionizing radiation is essential for predicting its behavior in solution. Here, we present significant advances in our understanding of radiation-induced plutonium redox chemistry by using time-resolved (electron pulse) and dose accumulation (alpha and gamma) irradiation techniques, along with quantitative multiscale modeling methods.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparing the magnetic resonant coupling radiofrequency stimulation to the traditional approaches: Ex-vivo tissue voltage measurement and electromagnetic simulation analysis

Recently, the design concept of magnetic resonant coupling has been adapted to electromagnetic therapy applications such as non-invasive radiofrequency (RF) stimulation. This technique can significantly increase the electric field radiated from the magnetic coil at the stimulation target, and hence enhancing the current flowing through the nerve, thus enabling stimulation. In this paper, the developed magnetic resonant coupling (MRC) stimulation, magnetic stimulation (MS) and transcutaneous electrical nerve stimulation (TENS) are compared. The differences between the MRC RF stimulation and other techniques are presented in terms of the operating mechanism, ex-vivo tissue voltage measurement and electromagnetic simulation analysis. The ev-vivo tissue voltage measurement experiment is performed on the compared devices based on measuring the voltage induced by electromagnetic induction at the tissue. The focusing effect, E field and voltage induced across the tissue, and the attenuation due to the increase of separation between the coil and the target are analyzed. The electromagnetic stimulation will also be performed to obtain the electric field and magnetic field distribution around the biological medium. The electric field intensity is proportional to the induced current and the magnetic field is corresponding to the electromagnetic induction across the biological medium. The comparison between the MRC RF stimulator and the MS and TENS devices revealed that the MRC RF stimulator has several advantages over the others for the applications of inducing current in the biological medium for stimulation purposes.

60 APPLIED LIFE SCIENCES↗

An Update of the Phase III Trial Comparing Whole Pelvic to Prostate Only Radiotherapy and Neoadjuvant to Adjuvant Total Androgen Suppression: Updated Analysis of RTOG 94-13, With Emphasis on Unexpected Hormone/Radiation Interactions

Purpose: This trial was designed to test the hypothesis that total androgen suppression and whole pelvic radiotherapy (WPRT) followed by a prostate boost improves progression-free survival (PFS) by {>=}10% compared with total androgen suppression and prostate only RT (PORT). This trial was also designed to test the hypothesis that neoadjuvant hormonal therapy (NHT) followed by concurrent total androgen suppression and RT improves PFS compared with RT followed by adjuvant hormonal therapy (AHT) by {>=}10%. Methods and Materials: Patients eligible for the study included those with clinically localized adenocarcinoma of the prostate and an elevated prostate-specific antigen level of <100 ng/mL. Patients were stratified by T stage, prostate-specific antigen level, and Gleason score and were required to have an estimated risk of lymph node involvement of >15%. Results: The difference in overall survival for the four arms was statistically significant (p = 0.027). However, no statistically significant differences were found in PFS or overall survival between NHT vs. AHT and WPRT compared with PORT. A trend towards a difference was found in PFS (p = 0.065) in favor of the WPRT + NHT arm compared with the PORT + NHT and WPRT + AHT arms. Conclusions: Unexpected interactions appear to exist between the timing of hormonal therapy and radiation field size for this patient population. Four Phase III trials have demonstrated better outcomes when NHT was combined with RT compared with RT alone. The Radiation Therapy Oncology Group 9413 trial results have demonstrated that when NHT is used in conjunction with RT, WPRT yields a better PFS than does PORT. It also showed that when NHT + WPRT results in better overall survival than does WPRT + short-term AHT. Additional studies are warranted to determine whether the failure to demonstrate an advantage for NHT + WPRT compared with PORT + AHT is chance or, more likely, reflects a previously unrecognized biologic phenomenon.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo simulation of an x-ray volume imaging cone beam CT unit

In this work the authors characterized the radiation field produced by a kilovolt cone beam computed tomography (CBCT) unit integrated in the Elekta Synergy linear accelerator. The x-ray volume imaging (XVI) radiation unit was modeled in detail using the BEAMNRC Monte Carlo (MC) code system. The simulations of eight collimator cassettes and the neutral filter F0 were successfully carried out. MC calculations from the EGSNRC code DOSXYZNRC were benchmarked against measurements in water. A large set of depth dose and lateral profiles was acquired with the ionization chamber in water, with the x-ray tube in a stationary position, and with the beam energy set to 120 kV. Measurements for all the available collimator cassettes were compared with calculations, showing very good agreement (<2% in most cases). Furthermore, half value layer measurements were carried out and used to validate the MC model of the XVI unit. In this case dose calculations were performed with the EGSNRC code cavity and these showed excellent agreement. In this manuscript the authors also report on the optimization work of the relevant parameters that influenced the development of the MC model. The dosimetric part of this work was very useful in characterizing the XVI radiation output for the energy of interest. The detailed simulation part of the work is the first step toward an accurate MC based assessment of the dose delivered to patients during routine CBCT scans for image and dose guided radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate Holdup Calculations with Predictive Modeling & Data Integration

In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use Bayes’ Theorem, one must have a model y(x) that maps the state variables x (the solution in this case) to the measurements y. In this case, the unknown state variables are the configuration and composition of the heldup SNM. The measurements are the detector readings. Thus, the natural model is neutral-particle radiation transport where a wealth of computational tools exists for performing these simulations accurately and efficiently. The combination of predictive model and Bayesian inference forms the Data Integration with Modeled Predictions (DIMP) method that serves as foundation for this project. The cost functional describing the model-to-data misfit is computed via a norm created by the inverse of the covariance matrix of the model parameters and responses. Since the model y(x) for the holdup problem is nonlinear, a nonlinear optimization on Q is conducted via Newton-type iterative methods to find the optimal values of the model parameters x. This project comprised a collaboration between NC State University (NCSU), the University of South Carolina (USC), and Oak Ridge National Laboratory (ORNL). The project was originally proposed in seven main tasks with an eighth contingency task to be performed if time and funding permitted; in fact time did not permit commencement of the contingency task and it was not performed. The remaining tasks involved holdup analysis with gamma detection strategies and separately with neutrons based on coincidence counting. Early in the project, and upon consultation with experts in coincidence counting it became evident that this approach is not viable for holdup applications and this task was replaced with an alternative, but valuable investigation that was carried out by the USC partner. Nevertheless, the experimental 4 measurements at ORNL of both gamma and neutron sources for the purpose of constructing Detector Response Functions (DRFs) with the associated uncertainties were indeed completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal radiation model for solid rocket booster plumes

The Monte Carlo method is used to model the thermal radiation field of the plumes for the dual solid rocket boosters astride the Space Shuttle launch configuration. The model accounts for axial and radial variations in radiative properties of the plumes. The plumes are considered to be composed of a dispersion of aluminum oxide (Al2O3) particles immersed in the gaseous products of combustion. The principal emitting gases are taken to be CO, CO2, H2O, and HCl. The thermal model is based on local thermodynamic equilibrium. Scattering of radiant energy by Al2O3 particles may be treated as isotropic or anisotropic. Sample radiant heating rates to the base region of the Space Shuttle are shown. Space Shuttle geometries are simulated as combinations of quadric surfaces.

Watson, G. H.↗

Experimental study using Nearfield Acoustical Holography of sound transmission fuselage sidewall structures

This project involves the development of the Nearfield Acoustic Holography (NAH) technique (in particular its extension from single frequency to wideband noise measurement) and its application in a detailed study of the noise radiation characteristics of several samples of aircraft sidewall panels. With the extensive amount of information provided by the NAH technique, the properties of the sound field radiated by the panels may be correlated with their structure, mounting, and excitation (single frequency or wideband, spatially correlated or uncorrelated, structure-borne). The work accomplished at the beginning of this grant period included: (1) Calibration of the 256 microphone array and test of its accuracy. (2) extension of the facility to permit measurements on wideband noise sources. The extensions incuded the addition of high-speed data acquisition hardware and an array processor, and the development of new software. (3) Installation of motion picture graphics for correlating panel motion with structure, mounting, radiation, etc. (4) Development of new holographic data processing techniques.

Maynard, J. D.↗