Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A Flexure-Based Mechanism for Precision Adjustment of National Ignition Facility Target Shrouds in Three Rotational Degrees of Freedom

This study presents the design of a flexure-based mount allowing adjustment in three rotational degrees of freedom (DOFs) through high-precision set-screw actuators. The requirements of the application called for small but controlled angular adjustments for mounting a cantilevered beam. The proposed design is based on an array of parallel beams to provide sufficiently high stiffness in the translational directions while allowing angular adjustment through the actuators. A simplified physical model in combination with standard beam theory was applied to estimate the deflection profile and maximum stresses in the beams. A finite element model was built to calculate the stresses and beam profiles for scenarios in which the flexure is simultaneously actuated in more than one DOF.

3 DOF↗

Establishing precision and accuracy in PDV results

We need to know uncertainties and systematic errors because we create and compare against archival weapons data, we constrain the models, and we provide scientific results. Good estimates of precision from the data record are available and should be incorporated into existing results; reanalysis of valuable data is suggested. Estimates of systematic errors are largely absent. The original work by Jensen et al. using gun shots for window corrections, and the integrated velocity comparison with X-rays by Schultz are two examples where any systematic errors appear to be <1% level.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Atomically Precise Metal Nanoclusters for Catalytic Application

The central goal of this project is to explore the catalytic application of atomically precise gold nanoclusters. By solving the total structures of ligand-protected nanoclusters, we aim to correlate the catalytic properties of metal nanoclusters with their atomic/electronic structures. Such correlation unravel some fundamental aspects of nanocatalysis, such as the nature of particle size effect, origin of catalytic selectivity, particle-support interactions, the identification of catalytically active centers, etc. The well-defined nanocluster catalysts mediate the knowledge gap between single crystal model catalysts and real-world conventional nanocatalysts. These nanoclusters also hold great promise in catalyzing certain types of reactions with extraordinarily high selectivity. These aims are in line with the overall goals of the catalytic science and technology of DOE and advance the BES mission “to support fundamental research to understand, predict, and ultimately control matter and energy at the level of electrons, atoms, and molecules”. Our group has successfully prepared different sized, robust gold nanoclusters protected by thiolates, such as Au 25 (SR) 18 , Au 28 (SR) 20 , Au 38 (SR) 24 , Au 99 (SR) 42 , Au 144 (SR) 60 , etc. Some of these nanoclusters have been crystallographically characterized through X-ray crystallography. These ultrasmall nanoclusters (< 2 nm diameter) exhibit discrete electronic structures due to quantum size effect, as opposed to quasicontinuous band structure of conventional metal nanoparticles or bulk metals. The available atomic structures (metal core plus surface ligands) of nanoclusters serve as the basis for structure-property correlations. We have investigated the unique catalytic properties of nanoclusters (i.e. not observed in conventional nanogold catalysts) and revealed the structure-selectivity relationships. Highlights of our works include: i) Effects of ligand, cluster charge state, and size on the catalytic reactivity in CO oxidation, semihydrogenation of alkynes; ii) Size-controlled synthesis of Au-n clusters and structural elucidation; iii) Catalytic mechanisms and correlation with structures of cluster catalyst; iv) Catalytic properties of Au nanorods in chemoselective hydrogenation of nitrobenzaldehyde and visible light driven photocatalytic reactions.

02 PETROLEUM↗

Mixed precision efficiency improvements for multi-physics flow simulations

This report summarizes research activities at Cascade Technologies during February 2020 - November 2020 to support DOE SBIR phase I contract DE-SC0020548. The primary technical objectives of the work are two-fold: a) to establish a theoretical framework to understand the propagation and impact of finite-precision-related errors and b) to quantify the trade-offs between accelerator throughput and solution accuracy through a series of validation tests involving multi-physics flow phenomena.

97 MATHEMATICS AND COMPUTING↗

Improving RNA-Seq Precision with MapAl

With currently available RNA-Seq pipelines, expression estimates for most genes are very noisy. We here introduce MapAl, a tool for RNA-Seq expression profiling that builds on the established programs Bowtie and Cufflinks. In the post-processing of RNA-Seq reads, it incorporates gene models already at the stage of read alignment, increasing the number of reliably measured known transcripts consistently by 50%. Adding genes identified de novo then allows a reliable assessment of double the total number of transcripts compared to other available pipelines. This substantial improvement is of general relevance: Measurement precision determines the power of any analysis to reliably identify significant signals, such as in screens for differential expression, independent of whether the experimental design incorporates replicates or not.

59 BASIC BIOLOGICAL SCIENCES↗

Predictive Risk Mapping of Schistosomiasis in Madagascar Using Ecological Niche Modeling and Precision Mapping

Schistosomiasis is a neglected tropical disease (NTD) found throughout tropical and subtropical Africa. In Madagascar, the condition is widespread and endemic in 74% of all administrative districts in the country. Despite the significant burden of the disease, high-resolution risk maps have yet to be produced to guide national control programs. This study used an ecological niche modeling (ENM) and precision mapping approach to estimate environmental suitability and disease transmission risk. The results show that suitability for schistosomiasis is widespread and covers 264,781 km 2 (102,232 sq miles). Covariates of significance to the model were the accessibility to cities, distance to water, enhanced vegetation index (EVI), annual mean temperature, land surface temperature (LST), clay content, and annual precipitation. Disease transmission risk is greatest in the central highlands, tropical east coast, arid-southwest, and northwest. An estimated 14.9 million people could be at risk of schistosomiasis; 11.4 million reside in rural areas, while 3.5 million are in urban areas. This study provides valuable insight into the geography of schistosomiasis in Madagascar and its potential risk to human populations. Because of the focal nature of the disease, these maps can inform national surveillance programs while improving understanding of areas in need of medical interventions.

60 APPLIED LIFE SCIENCES↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

(abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3

An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.

optical fiber precision time standards frequency r↗

Micro-Precision Interferometer: Pointing Control System

This paper describes the development of the wavefront tilt (pointing) control system for the JPL Micro-Precision Interferometer (MPI). This control system employs piezo-electric actuators and a digital imaging sensor with feedback compensation to reject errors in instrument pointing. Stringent performance goals require large feedback, however, several characteristics of the plant tend to restrict the available bandwidth. A robust 7th-order wavefront tilt control system was successfully implemented on the MPI instrument, providing sufficient disturbance rejection performance to satisfy the established interference fringe visibility.

Micro-Precision Pointing↗

Structural and Optical Pathlength Control Experiments on a Precision Truss

An experimental implementation of a nanometer level optical pathlength controller for long baseline space interferometry is presented. The pathlength compensation system is tested on a large precision truss structure and thus structural dynamics play a dominant role in the control system design.

telemetry precision truss↗