Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

On the practical exploitation of scarsity.

Scarsity is the notion that the Jacobian J for a given function f: {Re}{sup n} {yields} {Re}{sup m} may have fewer than n {sup *} m degrees of freedom. A scarse J may be represented by a graph with a minimal edge count. So far, scarsity has been recognized only from a high-level application point of view, and no automatic exploitation has been attempted. We introduce an approach to recognize and use scarsity in computational graphs in a source transformation context. The goal is to approximate the minimal graph representation through a sequence of transformations including eliminations, reroutings, and normalizations, with a secondary goal of minimizing the transformation cost. The method requires no application-level insight and is implemented as a fully automatic transformation in OpenAD. This paper introduces the problem and a set of heuristics to approximate the minimal graph representation. We also present results on a set of test problems.

97 MATHEMATICS AND COMPUTING↗

Practical Loop Transformations for Tensor Contraction Expressions on Multi-Level Memory Hierarchies

Modern architectures are characterized by deeper levels of memory hierarchy, often explicitly addressable. Optimizing applications for such architectures requires careful management of the data movement across all these levels. In this paper, we focus on the problem of mapping tensor contractions to memory hierarchies with more than two levels, specifically addressing placement of memory allocation and data movement statements, choice of loop fusions, and tile size selection. Existing algorithms to find an integrated solution to this problem even for two-level memory hierarchies has been shown to be expensive. We improve upon this work by focusing on the first-order cost components, simplifying the analysis required and reducing the number of candidates to be evaluated. We have evaluated our framework on a cluster of GPUs. Using five tensor contraction expressions, we show that fusion at multiple levels improves performance, and our framework is effective in determining protable transformations.

99 GENERAL AND MISCELLANEOUS↗

Advancing Understanding and Design of Functional Materials Through Theoretical and Computational Chemical Physics. In: Practical Aspects of Computational Chemistry II

Theoretical and computational chemical physics and materials science offers great opportunity toward helping solve some of the grand challenges in science and engineering, because structure and properties of molecules, solids, and liquids are direct reflections of the underlying quantum motion of their electrons. With the advent of semilocal and especially nonlocal descriptions of exchange and correlation effects, density functional theory (DFT) can now describe bonding in molecules and solids with an accuracy which, for many classes of systems, is sufficient to compare quantitatively to experiments. It is therefore becoming possible to develop a semiquantitative description of a large number of systems and processes. In this chapter, we briefly review DFT and its various extensions to include nonlocal terms that are important for long-range dispersion interactions that dominate many self-assembly processes, molecular surface adsorption processes, solution processes, and biological and polymeric materials. Applications of DFT toward problems relevant to energy systems, including energy storage materials, functional nanoelectronics/optoelectronics, and energy conversion, are highlighted.

Chemical reactions↗

Perianal sepsis: surgical perspective and practical MRI reporting for radiologists

This article describes the development of a structured MRI reporting template and diagrammatic worksheet for perianal sepsis through collaboration between radiologists and colorectal surgeons at our institution, and the rationale behind each component of the worksheet. Benefits of this reporting worksheet include optimizing communication of key imaging findings that have a real impact on patient management, less time spent on reporting the study, and easier comparison between studies. We illustrate the utility of the report template with case studies. We summarize the current surgical approaches to perianal sepsis to help radiologists focus on reporting the findings relevant to surgical planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The application of cinematic rendering to CT evaluation of upper tract urothelial tumors: principles and practice

Upper tract urothelial carcinoma (UTUC) is a relatively uncommon but aggressive genitourinary malignancy for which multi-phase contrast-enhanced computed tomography (CT) plays an important role in evaluation and staging. 3D imaging with maximum intensity projection (MIP) and volume-rendered (VR) images has been described as a useful means of evaluating UTUC. In this study, we describe the technique of a novel 3D methodology known as cinematic rendering (CR) and provide clinical examples of UTUC visualized with CR. CR utilizes a complex universal lighting model in order to create photorealistic images with improved detail and depth in comparison to MIP or VR images. In the case of UTUC, CR can be used in different contrast phases to show abnormally thickened and enhancing urothelium or filling defects in the renal collecting system or ureters in the excretory phase. CR images can also be manipulated in order to generate translucent views of the upper urinary tract in order to add conspicuity to intraluminal findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard of Practice for the Endovascular Treatment of Thoracic Aortic Aneurysms and Type B Dissections

Thoracic endovascular aortic repair (TEVAR) represents a minimally invasive technique alternative to conventional open surgical reconstruction for the treatment of thoracic aortic pathologies. Rapid advances in endovascular technology and procedural breakthroughs have contributed to a dramatic transformation of the entire field of thoracic aortic surgery. TEVAR procedures can be challenging and, at times, extraordinarily difficult. They require seasoned endovascular experience and refined skills. Of all endovascular procedures, meticulous assessment of anatomy and preoperative procedure planning are absolutely paramount to produce optimal outcomes. These guidelines are intended for use in quality-improvement programs that assess the standard of care expected from all physicians who perform TEVAR procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard of Practice for the Interventional Management of Isolated Iliac Artery Aneurysms

Isolated iliac artery aneurysms are uncommon, comprising less than 2% of all abdominal aneurysmal disease. Although they have a fairly innocuous natural history, when they have attained a large size they carry a significant risk of rupture. Rupture is associated with significant morbidity and mortality. Therefore, an early diagnosis and treatment are crucial. Over the last decade, interventional treatment options have become established alternatives to open surgical repair. These guidelines aim to review the pathogenesis, natural history, and presentation of isolated iliac artery aneurysms including a description of imaging and interventional treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Laser Fiber Design on Outcome of Endovenous Ablation of Lower-Extremity Varicose Veins: Results from a Single Practice

The design of laser fibers used for endovenous laser ablation (EVLA) in the management of lower-extremity varicose vein disease may affect treatment success. The purpose of this investigation is to report our experience using the gold-tip NeverTouch VenaCure laser fiber (AngioDynamics, Queensbury, NY) and to compare that to our experience with standard bare-tip fibers. A retrospective chart review of 363 consecutive EVLA treatments using the gold-tip laser fiber was performed. Demographic data including patient age, sex, history of previous varicose vein stripping, vein identity, laterality, treatment length, total applied energy in joules (J), use of adjuvant sclerotherapy and ambulatory phlebectomy, treatment-related complications, and treatment failure, which was defined as recanalization of any portion of the treated vein during follow-up as assessed by duplex ultrasound examination-were entered into a spreadsheet. These data were compared with a control group of 471 EVLA treatments performed with a standard bare-tip laser fiber. Data were analyzed using independent-samples Student's t test, chi-square test, and multivariate analysis. Demographic data were similar between the two groups. Treatments with the gold-tip fiber had a failure rate of 11.1%, whereas treatment with a bare-tip fiber had a failure rate of 2.3% during a similar follow-up period. This difference was highly statistically significant (p < 0.0001). Multivariate analysis showed fiber type as the most significant factor associated with treatment failure. We conclude that laser fiber design has a significant effect on treatment success in the performance of EVLA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standards of Practice: Quality Assurance Guidelines for Percutaneous Treatments of Intervertebral Discs

Percutaneous treatments are used in the therapy of small- to medium-sized hernias of intervertebral discs to reduce the intradiscal pressure in the nucleus and theoretically create space for the herniated fragment to implode inward, thus reducing pain and improving mobility and quality of life. These techniques involve the percutaneous removal of the nucleus pulposus by using a variety of chemical, thermal, or mechanical techniques and consist of removal of all or part of nucleus pulposus to induce more rapid healing of the abnormal lumbar disc. These guidelines are written to be used in quality improvement programs for assessing fluoroscopy- and/or computed tomography-guided percutaneous intervertebral disc ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical Vascular Anatomy in the Preparation of Radioembolization

As the incidence of primary and metastatic liver cancer continues to increase, the use of minimally invasive techniques as a treatment option is becoming more common. Radioembolization, a form of intra-arterial brachytherapy, is a technique where particles of glass or resin, impregnated with the isotope {sup 90}yttrium ({sup 90}Y), are infused through a catheter directly into the hepatic arteries. This modality is based on the fact that hepatic malignancies receive their blood supply from the hepatic artery, whereas normal hepatocytes are perfused mostly from the portal circulation, which allows delivery of high doses to the tumor vasculature with relative sparing of normal liver tissue. This has been shown to be effective for both primary and metastatic tumors. A variety of complications may be related to hepatic intra-arterial treatments, especially to the gastroduodenal region. These complications are known to come from inadvertent extrahepatic infusion of {sup 90}Y particles, through arteries originating from the hepatic arterial branches such as the falciform artery, cystic artery, arteries from the pancreaticoduodenal arcade, gastroduodenal artery, or right gastric artery. Surgeons and interventional radiologists rely on accurate imaging and assessment of the hepatic arterial supply. It is important to know the common anatomic variations and technical considerations before radioembolization. We recommend an aggressive occlusion of all the above-mentioned arteries; further, clinicians should watch out for any other aberrant branches, and if in doubt, they ought to be coiled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How to Prepare a Patient for Transarterial Radioembolization? A Practical Guide

Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Approach to Endovascular and Percutaneous Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS) Dysfunction: A Pictorial Essay and Clinical Practice Algorithm

Transjugular intrahepatic portosystemic shunts (TIPS) have evolved as an effective and durable nonsurgical option in the treatment of portal hypertension (PH). It has been shown to improve survival in decompensated cirrhosis and may also serve as a bridge to liver transplantation. In spite of the technical improvements in the procedure, problems occur with the shunt which jeopardizes effective treatment of the PH. Appropriate management is vital to ensure the longevity of the conduit. Shunt revision techniques include endovascular revision techniques and new shunt creation or, in the appropriate patients, alternative/rescue therapies. The ability of interventional radiologists to restore adequate TIPS function has enormous implications for quality of life with palliation, morbidity/mortality related to variceal bleeding and survival if transplant candidates can live long enough to receive a new liver. As such, it is imperative that these treatment strategies are understood and employed when these patients are encountered. In this review, the restoration of appropriate shunt function using various techniques will be discussed as they apply to a variety of clinical scenarios, based on literature. In addition, illustrative case examples highlighting our experience at an academic tertiary medical center will be included. It is the intent to have this document serve as a concise and informative reference to be used by those who may encounter patients with suboptimal functioning TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CIRSE Standards of Practice Guidelines on Gastrostomy

PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower rates of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗