Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The Design and Development of the SMEX-Lite Power System

This paper describes the design and development of a 250W orbit average electrical power system electronic Power Node and software for use in Low Earth Orbit missions. The mass of the Power Node is 3.6 Kg (8 lb.). The dimensions of the Power Node are 30cm x 26cm x 7.9cm (11 in. x 10.25 in x 3.1 in.) The design was realized using software, Field Programmable Gate Array (FPGA) digital logic and surface mount technology. The design is generic enough to reduce the non-recurring engineering for different mission configurations. The Power Node charges one to five, low cost, 22-cell 4 AH D-cell battery packs independently. The battery charging algorithms are executed in the power software to reduce the mass and size of the power electronic. The Power Node implements a peak-power tracking algorithm using an innovative hardware/software approach. The power software task is hosted on the spacecraft processor. The power software task generates a MIL-STD-1553 command packet to update the Power Node control settings. The settings for the battery voltage and current limits, as well as minimum solar array voltage used to implement peak power tracking are contained in this packet. Several advanced topologies are used in the Power Node. These include synchronous rectification in the bus regulators, average current control in the battery chargers and quasi-resonant converters for the Field Effect Transistor (FET) transistor drive electronics. Lastly, the main bus regulator uses a feed-forward topology with the PWM implemented in an FPGA.

Rakow, Glenn P.↗

Accelerating Acceptance of Fuel Cell Backup Power Systems - Final Report

Since 2001, Plug Power has installed more than 800 stationary fuel cell systems worldwide. Plug Power’s prime power systems have produced approximately 6.5 million kilowatt hours of electricity and have accumulated more than 2.5 million operating hours. Intermittent, or backup, power products have been deployed with telecommunications carriers and government and utility customers in North and South America, Europe, the United Kingdom, Japan and South Africa. Some of the largest material handling operations in North America are currently using the company’s motive power units in fuel cell-powered forklifts for their warehouses, distribution centers and manufacturing facilities. The low-temperature GenSys fuel cell system provides remote, off-grid and primary power where grid power is unreliable or nonexistent. Built reliable and designed rugged, low- temperature GenSys delivers continuous or backup power through even the most extreme conditions. Coupled with high-efficiency ratings, low-temperature GenSys reduces operating costs making it an economical solution for prime power requirements. Currently, field trials at telecommunication and industrial sites across the globe are proving the advantages of fuel cells—lower maintenance, fuel costs and emissions, as well as longer life—compared with traditional internal combustion engines.

Petrecky, James↗

Hubble Space Telescope electrical power system

The Hubble Space Telescope (HST) electrical power system (EPS) is supplying between 2000 and 2400 W of continuous power to the electrical loads. The major components of the EPS are the 5000-W back surface field reflector solar array, the six nickel-hydrogen (NiH2) 22-cell 88-Ah batteries, and the charge current controllers, which, in conjunction with the flight computer, control battery charging. The operation of the HST EPS and the results of the HST NiH2 six-battery test are discussed, and preliminary flight data are reviewed. The HST NiH2 six-battery test is a breadboard of the HST EPS on test at Marshall Space Flight Center.

Whitt, Thomas H.↗

Early Alarm: Robust Event Analysis for Power Systems using 1-D Fully Convolutional Network

This work presents a novel deep learning model for early, accurate, and robust detection, recognition, and temporal localization of multi-type events in large-scale power systems. The proposed method develops a unified 1-D fully convolutional network (FCN) model that takes time series of raw frequency signals measured from a power system as input, extracts distinguishing features, and predicts at every temporal point in the time series if an event is happening and what the type of the event is. Compared to existing methods, the proposed model eliminates the necessity for hand-crafted feature extraction or complicated data pre-processing, can flexibly handle input signals of arbitrary length, and precisely infer the event occurrence time. Most importantly, the model is intentionally trained with incomplete patterns, such that it is more robust to partial features of an event which is common in real-world online recognition, resulting in early alarm for power system failures. Extensive experimental results demonstrate that the proposed method achieves superior performance to the state-of-the-art, and also shows strong robustness to noise and system oscillations.

Li, Chengcheng↗

SP-100 power system development status

The SP-100 ground engineering system development project objectives, approach and status are described. The SP-100 GES development project is phase II of a three-phase program funded and directed by three United States Federal Agencies (NASA, DOD and DOE) to develop space reactor power systems for space applications in the 10 to 1000 KWe power range. The first phase of the program lasted three years, and this was completed at the end of FY 1985. SP-100 Phase I analytically and experimentally reviewed all near-term space reactor power system candidates and selected one system that best met the project mission requirements for future civilian and military space applications. The SP-100 Phase II started in fiscal year 1986 to develop the Phase I selected space reactor power system to be technically ready for space applications in the mid- to late 1990s.

Mondt, Jack F.↗

Analysis of a Fluidized-Bed Particle/Supercritical-CO2 Heat Exchanger in a Concentrating Solar Power System

Concentrating solar power (CSP) development has focused on increasing the energy conversion efficiency and lowering the capital cost. To improve performance, CSP research is moving to high-temperature and high-efficiency designs. One technology approach is to use inexpensive, high-temperature heat transfer fluids and storage, integrated with a high-efficiency power cycle such as the supercritical carbon dioxide (sCO 2 ) Brayton power cycle. The sCO 2 Brayton power cycle has strong potential to achieve performance targets of 50% thermal-to-electric efficiency and dry cooling at an ambient temperature of up to 40 °C and to reduce the cost of power generation. Solid particles have been proposed as a possible high-temperature heat transfer or storage medium that is inexpensive and stable at high temperatures above 1000 °C. The particle/sCO 2 heat exchanger (HX) provides a connection between the particles and sCO 2 fluid in emerging sCO 2 power cycles. This article presents heat transfer modeling to analyze the particle/sCO 2 HX design and assess design tradeoffs including the HX cost. The heat transfer process was modeled based on a particle/sCO 2 counterflow configuration, and empirical heat transfer correlations for the fluidized bed and sCO 2 were used to calculate heat transfer area and estimate the HX cost. A computational fluid dynamics simulation was applied to characterize particle distribution and fluidization. This article shows a path to achieve the cost and performance objectives for a particle/sCO 2 HX design by using fluidized-bed technology.

14 SOLAR ENERGY↗

Tuning circuitry for a wireless power system

A wireless power supply power supply including first tuning circuitry coupled directly to a transmitter, the first tuning circuitry including an LCC configuration. The wireless power supply may include second tuning circuitry coupled directly to switching circuitry (e.g., an inverter) of the power supply, where the second tuning circuitry may be operable to direct power from the switching circuitry to the first tuning circuitry for supply to the transmitter, and where the second tuning circuitry includes a reactance operable to establish inductive operation of the switching circuitry at the switching frequency of the switching circuitry.

Pries, Jason L.↗

Systems approach to walk-off problems for dish-type solar thermal power systems

'Walk-off' in a dish-type solar thermal power system is a failure situation in which the concentrator remains fixed while the spot of concentrated sunlight slowly moves across the face of the receiver. The intense local heating may damage the receiver and nearby equipment. Passive protection has advantages in minimizing damage, but in a fully passive design the receiver must be able to withstand full solar input with no forced fluid circulation during the walk-off. An active walk-off emergency subsystem may include an emergency detrack or defocus mechanism or sun-blocking device, emergency power, sensors and logic to detect the emergency and initiate protective action, and cooling or passive protection of emergency and non-emergency components. Each of these elements is discussed and evaluated in the paper.

Jaffe, L. D.↗

Bridging Power System Protection Gaps with Data-driven Approaches

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this research, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A convolutional neural network (CNN) based fault detection approach is implemented to achieve data translation invariance of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN–based method avoids the complicated manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on four kinds of protection gaps: high impedance faults, transformer/generator inter-turn faults, distribution system PV circuit faults, and the mis-operation situations of Zone 3 line protection relays operating under system stress. Finally, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lunar power system summary of studies for the lunar enterprise task force NASA-office of exploration

The capacity of global power systems must be increased by a factor of ten to provide the predicted power needs of electric power by the year 2050. The Lunar Power System (LPS) would collect solar energy at power bases located on opposing limbs of the moon as seen from Earth. LPS can provide dependable, economic, renewable, and environmentally benign solar energy to Earth. A preliminary engineering and cash flow model of the LPS was developed. Results are shown for a system scaled to a peak capacity of 355 GWe on Earth and to provide 13,600 GWe-Yrs of energy over a 70 year life cycle of construction and full operation. The growth in capacity of the reference system from start of installation on the moon in 2005 to completion of its nominal life cycle in the year 2070 is shown. World needs for power could be accommodated by expansion in capacity of the reference LPS beyond 344 GWe. This would be done by steadily incorporating newer technology during full operation and by establishing additional bases. The results presented encourage consideration of a faster paced program than is assumed herein.

Criswell, David R.↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

Power Systems Resilience

As communities take steps toward identifying and achieving their clean energy goals, the topic of resilience will likely emerge. This presentation aims to help inform and empower communities as they explore how their clean energy projects can address evolving power systems reliability and resilience due to climate change and other factors. The training provides a basic introduction to power systems and the resilience challenges this traditional infrastructure faces, as well as strategies for enhancing this important quality of electric service.

communities↗

Satellite Power System (SPS) environmental impacts, preliminary assessment

Present power plant assessment factors are used to present satellite power system (SPS) impacts. In contrast to oil, gas, nuclear and coal fueled power plants, the SPS and hydroelectric power plants produce air, water, and solid waste emissions only during the construction phase. Land use impacts result from the placement of rectennas used for microwave receiving and rectifying. Air quality impacts of the SPS resulting from the construction phase amount to 0.405 metric tons per megawatt year. Solid wastes impacts are 0.108 metric tons per year of operation. Other impacts such as those caused by heavy lift launch vehicle sites are also discussed.

Livingston, F. R.↗

Systems and methods for single-axis tracking via sky imaging and machine leanring comprising a neural network to determine an angular position of a photovoltaic power system

A system and method is disclosed for solar tracking and controlling an angular position of a photovoltaic power system. The solar tracking system includes an imaging device for capturing images of the sky; a solar position data generating module; and a control system comprising a neural network. The neural network has multiple convolutional layers to generate a first output associated with the images, and a solar position data module. A first dense layer module receives the solar position data and generates a second output. A second dense layer module receives the first output and the second output and generates a concatenated data sequence. A processor is programmed to generate a multi-planar irradiance signal (MPIS) in response to the concatenated data sequence, and determine an angular position of the PV power system and adjust the angular position in response to an angle of maximum irradiance.

Stein, Joshua↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗