Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portable Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Rainfall Estimates from the TMI and the SSM/I

The Tropical Rainfall Measuring Mission (TRMM), which is a joint Japan-U.S. Earth observing satellite, has been successfully launched from Japan on November 27, 1997. The main purpose of the TRMM is to measure quantitatively rainfall over the tropics for the research of climate and weather. One of three rainfall measuring instruments abroad the TRMM is the high resolution TRMM Microwave Imager (TMI). The TMI instrument is essentially the copy of the SSM/I with a dual-polarized pair of 10.7 GHz channels added to increase the dynamic range of rainfall estimates. In addition, the 21.3 GHz water vapor absorption channel is designed in the TMI as opposed to the 22.235 GHz in the SSM/I to avoid saturation in the tropics. This paper will present instantaneous rain rates estimated from the coincident TMI and SSM/I observations. The algorithm for estimating instantaneous rainfall rates from both sensors is the Goddard Profiling algorithm (Gprof). The Gprof algorithm is a physically based, multichannel rainfall retrieval algorithm, The algorithm is very portable and can be used for various sensors with different channels and resolutions. The comparison of rain rates estimated from TMI and SSM/I on the same rain regions will be performed. The results from the comparison and the insight of tile retrieval algorithm will be given.

Hong, Ye↗

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic signatures of past water and extinct life on the surface of planetary bodies such as Mars. It is designed to perform rapid, in situ spectroscopy consuming extremely low energy per measurement. Additional information is contained in the original extended abstract.

Jurewicz, S. R.↗

Big Software for SmallSats: Adapting CFS to CubeSat Missions

Expanding capabilities and mission objectives for SmallSats and CubeSats is driving the need for reliable, reusable, and robust flight software. While missions are becoming more complicated and the scientific goals more ambitious, the level of acceptable risk has decreased. Design challenges are further compounded by budget and schedule constraints that have not kept pace. NASA's Core Flight Software System (cFS) is an open source solution which enables teams to build flagship satellite level flight software within a CubeSat schedule and budget. NASA originally developed cFS to reduce mission and schedule risk for flagship satellite missions by increasing code reuse and reliability. The Lunar Reconnaissance Orbiter, which launched in 2009, was the first of a growing list of Class B rated missions to use cFS. Large parts of cFS are now open source, which has spurred adoption outside of NASA. This paper reports on the experiences of two teams using cFS for current CubeSat missions. The performance overheads of cFS are quantified, and the reusability of code between missions is discussed. The analysis shows that cFS is well suited to use on CubeSats and demonstrates the portability and modularity of cFS code.

Open Source↗

Ammonia-Removal Efficiency By Full-Scale Carbon-Based Trace-Contaminant Sorbent Monoliths Integrated With the Rapid-Cycle Amine (RCA) Swing Bed

Results are presented on full-scale performance testing of vacuum-regenerable, carbon based sorbent monoliths for trace-contaminant (TC) removal integrated with the Rapid-Cycle Amine (RCA) swing bed for use in the Portable Life Support System (PLSS) during Extravehicular Activities (EVAs). The current state-of-art in TC-control technology involves the use of a packed bed of acid-impregnated granular charcoal, which is difficult to regenerate. The carbon-based sorbent under development in this project can be regenerated by exposure to vacuum at room temperature. Data on cyclic sorption-desorption of ammonia, which is a major TC of concern, were collected in a simulated PLSS ventilation loop which involved the RCA placed upstream of the Trace Contaminant Control System (TCCS). Results of testing involving pressure-swing operation of the integrated TCCS/RCA system indicate ammonia-removal efficiency exceeding 80% throughout multiple sorption-desorption cycles. This paper presents an overview of the TCCS research, the favorable results obtained, and provides insight into future work needed to further the technology development.

Marek A Wójtowicz↗

Non-destructive measurement and real-time monitoring of apple hardness during ultrasonic contact drying via portable NIR spectroscopy and machine learning

Portable near-infrared spectrometer in the spectral range of 900–1700 nm was evaluated for the first time to assess and monitor apple hardness in real-time during ultrasonic drying. Calibration models were developed using PLS and ANN, and their performances were evaluated by internal leave-one-out cross-validation and an external dataset. Several pre-treatments including standard normal variate (SNV), multiplicative scatter correction (MSC), Savitzky–Golay first and second derivatives were employed to examine the effects of spectral variations in hardness prediction. Seven important wavelengths were selected using weighted regression coefficients to develop a simple MLR model to facilitate the model interpretation and circumvent noise. The models using PLS, MLR, and ANN with selected wavelengths predicted the apple hardness with R 2 p of 0.91, 0.91, 0.95, and RMSEP of 14.78, 14.85, and 12.46 N, respectively. Finally, the results indicate that portable NIR spectrometers are quite promising for real-time monitoring of apple hardness during ultrasonic drying.

47 OTHER INSTRUMENTATION↗

Use Computer-Aided Tools to Parallelize Large CFD Applications

Porting applications to high performance parallel computers is always a challenging task. It is time consuming and costly. With rapid progressing in hardware architectures and increasing complexity of real applications in recent years, the problem becomes even more sever. Today, scalability and high performance are mostly involving handwritten parallel programs using message-passing libraries (e.g. MPI). However, this process is very difficult and often error-prone. The recent reemergence of shared memory parallel (SMP) architectures, such as the cache coherent Non-Uniform Memory Access (ccNUMA) architecture used in the SGI Origin 2000, show good prospects for scaling beyond hundreds of processors. Programming on an SMP is simplified by working in a globally accessible address space. The user can supply compiler directives, such as OpenMP, to parallelize the code. As an industry standard for portable implementation of parallel programs for SMPs, OpenMP is a set of compiler directives and callable runtime library routines that extend Fortran, C and C++ to express shared memory parallelism. It promises an incremental path for parallel conversion of existing software, as well as scalability and performance for a complete rewrite or an entirely new development. Perhaps the main disadvantage of programming with directives is that inserted directives may not necessarily enhance performance. In the worst cases, it can create erroneous results. While vendors have provided tools to perform error-checking and profiling, automation in directive insertion is very limited and often failed on large programs, primarily due to the lack of a thorough enough data dependence analysis. To overcome the deficiency, we have developed a toolkit, CAPO, to automatically insert OpenMP directives in Fortran programs and apply certain degrees of optimization. CAPO is aimed at taking advantage of detailed inter-procedural dependence analysis provided by CAPTools, developed by the University of Greenwich, to reduce potential errors made by users. Earlier tests on NAS Benchmarks and ARC3D have demonstrated good success of this tool. In this study, we have applied CAPO to parallelize three large applications in the area of computational fluid dynamics (CFD): OVERFLOW, TLNS3D and INS3D. These codes are widely used for solving Navier-Stokes equations with complicated boundary conditions and turbulence model in multiple zones. Each one comprises of from 50K to 1,00k lines of FORTRAN77. As an example, CAPO took 77 hours to complete the data dependence analysis of OVERFLOW on a workstation (SGI, 175MHz, R10K processor). A fair amount of effort was spent on correcting false dependencies due to lack of necessary knowledge during the analysis. Even so, CAPO provides an easy way for user to interact with the parallelization process. The OpenMP version was generated within a day after the analysis was completed. Due to sequential algorithms involved, code sections in TLNS3D and INS3D need to be restructured by hand to produce more efficient parallel codes. An included figure shows preliminary test results of the generated OVERFLOW with several test cases in single zone. The MPI data points for the small test case were taken from a handcoded MPI version. As we can see, CAPO's version has achieved 18 fold speed up on 32 nodes of the SGI O2K. For the small test case, it outperformed the MPI version. These results are very encouraging, but further work is needed. For example, although CAPO attempts to place directives on the outer- most parallel loops in an interprocedural framework, it does not insert directives based on the best manual strategy. In particular, it lacks the support of parallelization at the multi-zone level. Future work will emphasize on the development of methodology to work in a multi-zone level and with a hybrid approach. Development of tools to perform more complicated code transformation is also needed.

Jin, H.↗

Locomotor Adaptation Improves Balance Control, Multitasking Ability and Reduces the Metabolic Cost of Postural Instability

During exploration-class missions, sensorimotor disturbances may lead to disruption in the ability to ambulate and perform functional tasks during the initial introduction to a novel gravitational environment following a landing on a planetary surface. The overall goal of our current project is to develop a sensorimotor adaptability training program to facilitate rapid adaptation to these environments. We have developed a unique training system comprised of a treadmill placed on a motion-base facing a virtual visual scene. It provides an unstable walking surface combined with incongruent visual flow designed to enhance sensorimotor adaptability. Greater metabolic cost incurred during balance instability means more physical work is required during adaptation to new environments possibly affecting crewmembers? ability to perform mission critical tasks during early surface operations on planetary expeditions. The goal of this study was to characterize adaptation to a discordant sensory challenge across a number of performance modalities including locomotor stability, multi-tasking ability and metabolic cost. METHODS: Subjects (n=15) walked (4.0 km/h) on a treadmill for an 8 -minute baseline walking period followed by 20-minutes of walking (4.0 km/h) with support surface motion (0.3 Hz, sinusoidal lateral motion, peak amplitude 25.4 cm) provided by the treadmill/motion-base system. Stride frequency and auditory reaction time were collected as measures of locomotor stability and multi-tasking ability, respectively. Metabolic data (VO2) were collected via a portable metabolic gas analysis system. RESULTS: At the onset of lateral support surface motion, subj ects walking on our treadmill showed an increase in stride frequency and auditory reaction time indicating initial balance and multi-tasking disturbances. During the 20-minute adaptation period, balance control and multi-tasking performance improved. Similarly, throughout the 20-minute adaptation period, VO2 gradually decreased following an initial increase after the onset of support surface motion. DISCUSSION: Resu lts confirmed that walking in discordant conditions not only compromises locomotor stability and the ability to multi-task, but comes at a quantifiable metabolic cost. Importantly, like locomotor stability and multi-tasking ability, metabolic expenditure while walking in discordant sensory conditions improved during adaptation. This confirms that sensorimotor adaptability training can benefit multiple performance parameters central to the successful completion of critical mission tasks.

Bloomberg, J. J.↗

Community Geothermal: Final Thermal Conductivity Test Report and Data Logs - Carbondale, CO

Provided here are a final thermal conductivity test report, a drilling log, and a heat rejection log from Carbondale, CO. Also attached is a report made before drilling, which contains predictions on the hydrogeologic conditions of the drill site. The forty-eight (48.9) hour in-situ thermal conductivity test was performed on the 28th through the 30th, of November 2023. The test was performed at the borehole drilled on November 16th through the 20th, at the 3rd Street Center at 520 S. 3rd, Street in Carbondale, Colorado. Testing was done with a certified Ewbank portable test unit.

15 GEOTHERMAL ENERGY↗

CLIPS: An expert system tool for delivery and training

The C Language Integrated Production System (CLIPS) is a forward chaining rule-based language. The requirements necessary for an expert system tool which is used for development, delivery, and training are examined. Because of its high portability, low cost, and ease of integration with external systems, CLIPS has great potential as an expert system tool for delivery and training. In addition, its representation flexibility, debugging aids, and performance, along with its other strengths, make it a viable alternative for expert system development.

Riley, Gary↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

Compact, Controlled Resistance Exercise Device

Spaceflight leads to muscle and bone atrophy. Isoinertial (free-weight) exercises provide a sufficient stimulus to elicit increases in both muscle strength and bone mineral density in Earth-based studies. While exercise equipment is in use on the International Space Station for crewmember health maintenance, current devices are too large to place in a transport vehicle or small spacecraft. Therefore, a portable computer controlled resistance exercise device is being developed that is able to simulate the inertial loading experienced when lifting a mass on Earth. This portable device weighs less than 50 lb and can simulate the resistance of lifting and lowering up to 600 lb of free-weights. The objective is to allow crewmembers to perform resistance exercise with loads capable of maintaining muscle and bone health. The device is reconfigurable and allows for the performance of typical Earth-based free-weight exercises. Forces exerted, volume of work, range of motion, time-under-tension, and speed/ acceleration of movement are recorded and can be remotely monitored to track progress and modify individual protocols based on exercise session data. A performance evaluation will be completed and data will be presented that include ground-reaction force comparisons between the device and free-weight dead-lifts over a spectrum of resistance levels. Movement biomechanics will also be presented.

Paulus, David C.↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment plus 3 dB and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Winkel, James P.↗

Combined Qualification Vibration Testing and Fixed Base Modal Testing Utilizing a Fixed Based Correction Method

Vibration testing spaceflight hardware is a vital, but time consuming and expensive endeavor. Traditionally modal tests are performed at the component, subassembly, or system level, preferably free-free with mass loaded interfaces or fixed base on a seismic mass to identify the fundamental structural dynamic (modal) characteristics. Vibration tests are then traditionally performed on single-axis slip tables at qualification levels that envelope the maximum predicted flight environment and workmanship in order to verify the spaceflight hardware can survive its flight environment. These two tests currently require two significantly different test setups, facilities, and ultimately reconfiguration of the spaceflight hardware. The vision of this research is to show how traditional fixed-base modal testing can be accomplished using vibration qualification testing facilities, which not only streamlines testing and reduces test costs, but also opens up the possibility of performing modal testing to untraditionally high excitation levels that provide for test-correlated finite element models to be more representative of the spaceflight hardware's response in a flight environment. This paper documents the first steps towards this vision, which is the comparison of modal parameters identified from a traditional fixed-based modal test performed on a modal floor and those obtained by utilizing a fixed based correction method with a large single-axis electrodynamic shaker driving a slip table supplemented with additional small portable shakers driving on the slip table and test article. To show robustness of this approach, the test article chosen is a simple linear weldment, whose mass, size, and modal parameters couple well with the dynamics of the shaker/slip table. This paper will show that all dynamics due to the shaker/slip table were successfully removed resulting in true fixed-base modal parameters, including modal damping, being successfully extracted from a traditional style base-shake vibration test setup.

Base-Shake↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Oxygen Loss in Layered Oxide Cathodes for Li-Ion Batteries: Mechanisms, Effects, and Mitigation

Layered lithium transition metal oxides derived from LiMO 2 (M = Co, Ni, Mn, etc.) have been widely adopted as the cathodes of Li-ion batteries for portable electronics, electric vehicles, and energy storage. Oxygen loss in the layered oxides is one of the major factors leading to cycling-induced structural degradation and its associated fade in electrochemical performance. Herein, we review recent progress in understanding the phenomena of oxygen loss and the resulting structural degradation in layered oxide cathodes. We first present the major driving forces leading to the oxygen loss and then describe the associated structural degradation resulting from the oxygen loss. Here, we follow this analysis with a discussion of the kinetic pathways that enable oxygen loss, and then we address the resulting electrochemical fade. Finally, we review the possible approaches toward mitigating oxygen loss and the associated electrochemical fade as well as detail novel analytical methods for probing the oxygen loss.

36 MATERIALS SCIENCE↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Advanced Extravehicular Protective System (AEPS) study

A summary is presented of Advanced Extravehicular Protective Systems (AEPS) for the future missions beyond Skylab in earth orbit, on the lunar surface, and on the Martian surface. The study concentrated on the origination of regenerable life support concepts for use in portable extravehicular protective systems, and included evaluation and comparison with expendable systems, and selection of life support subsystems. The study was conducted in two phases. In the first phase, subsystem concepts for performing life support functions in AEPS which are regenerable or partially regenerable were originated, and in addition, expendable subsystems were considered. Parametric data for each subsystem concept were evolved including subsystem weight and volume, power requirement, thermal control requirement; base regeneration equipment weight and volume, requirement. The second phase involved an evaluation of the impact of safety considerations involving redundant and/or backup systems on the selection of the regenerable life support subsystems. In addition, the impact of the space shuttle program on regenerable life support subsystem development was investigated.

Williams, J. L.↗

Wireless microphone communication system telephonics P/N 484D000-1

The wireless microphone is a lightweight, portable, wireless voice communications device for use by the crew of the space shuttle orbiter. The wireless microphone allows the crew to have normal hands-free voice communication while they are performing various mission activities. The unit is designed to transmit at 455 or 500 kilohertz and employs narrow band FM modulation. Two orthogonally placed antennas are used to insure good reception at the receiver.

Source record↗