Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-493: Analysis of the Impact of Range and Setup Uncertainties On the Dose to Brain Stem and Whole Brain in the Passively Scattered Proton Therapy Plans

Purpose: To quantify the impact of range and setup uncertainties on various dosimetric indices that are used to assess normal tissue toxicities of patients receiving passive scattering proton beam therapy (PSPBT). Methods: Robust analysis of sample treatment plans of six brain cancer patients treated with PSPBT at our facility for whom the maximum brain stem dose exceeded 5800 CcGE were performed. The DVH of each plan was calculated in an Eclipse treatment planning system (TPS) version 11 applying ±3.5% range uncertainty and ±3 mm shift of the isocenter in x, y and z directions to account for setup uncertainties. Worst-case dose indices for brain stem and whole brain were compared to their values in the nominal plan to determine the average change in their values. For the brain stem, maximum dose to 1 cc of volume, dose to 10%, 50%, 90% of volume (D10, D50, D90) and volume receiving 6000, 5400, 5000, 4500, 4000 CcGE (V60, V54, V50, V45, V40) were evaluated. For the whole brain, maximum dose to 1 cc of volume, and volume receiving 5400, 5000, 4500, 4000, 3000 CcGE (V54, V50, V45, V40 and V30) were assessed. Results: The average change in the values of these indices in the worst scenario cases from the nominal plan were as follows. Brain stem; Maximum dose to 1 cc of volume: 1.1%, D10: 1.4%, D50: 8.0%, D90:73.3%, V60:116.9%, V54:27.7%, V50: 21.2%, V45:16.2%, V40:13.6%,Whole brain; Maximum dose to 1 cc of volume: 0.3%, V54:11.4%, V50: 13.0%, V45:13.6%, V40:14.1%, V30:13.5%. Conclusion: Large to modest changes in the dosiemtric indices for brain stem and whole brain compared to nominal plan due to range and set up uncertainties were observed. Such potential changes should be taken into account while using any dosimetric parameters for outcome evaluation of patients receiving proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-505: CT-Based Independent Dose Verification for RapidArc Plan as a Secondary Check

Purpose: To design and develop a CT-based independent dose verification for the RapidArc plan and also to show the effectiveness of inhomogeneous correction in the secondary check for the plan. Methods: To compute the radiological path from the body surface to the reference point and equivalent field sizes from the multiple MLC aperture shapes in the RapidArc MLC sequences independently, DICOM files of CT image, structure and RapidArc plan were imported to our in-house software. The radiological path was computed using a three-dimensional CT arrays for each segment. The multiple MLC aperture shapes were used to compute tissue maximum ratio and phantom scatter factor using the Clarkson-method. In this study, two RapidArc plans for oropharynx cancer were used to compare the doses in CT-based calculation and water-equivalent phantom calculation using the contoured body structure to the dose in a treatment planning system (TPS). Results: The comparison in the one plan shows good agreement in both of the calculation (within 1%). However, in the other case, the CT-based calculation shows better agreement compared to the water-equivalent phantom calculation (CT-based: -2.8% vs. Water-based: -3.8%). Because there were multiple structures along the multiple beam paths and the radiological path length in the CT-based calculation and the path in the water-homogenous phantom calculation were comparatively different. Conclusion: RapidArc treatments are performed in any sites (from head, chest, abdomen to pelvis), which includes inhomogeneous media. Therefore, a more reliable CT-based calculation may be used as a secondary check for the independent verification.

60 APPLIED LIFE SCIENCES↗

SU-E-T-617: A Feasibility Study of Navigation Based Multi Criteria Optimization for Advanced Cervical Cancer IMRT Planning

Purpose: This study aims to validate multi-criteria optimization (MCO) against standard intensity modulated radiation therapy (IMRT) optimization for advanced cervical cancer in RayStation (v2.4, RaySearch Laboratories, Sweden). Methods: 10 advanced cervical cancer patients IMRT plans were randomly selected, these plans were designed with step and shoot optimization, new plans were then designed with MCO based on these plans,while keeping optimization conditions unchanged,comparison was made between both kinds of plans including the dose volume histogram parameters of PTV and OAR,and were analysed by pairing-t test. Results: We normalize the plan so that 95% volume of PTV achieved the prescribed dose(50Gy). The volume of radiation 10, 20, 30, and 40 Gy of the rectum were reduced by 14.7%,26.8%,21.1%,10.5% respectively(P≥0.05). The mean dose of rectum were reduced by 7.2Gy(P≤0.05). There were no significant differences for the dosimetric parameters for the bladder. Conclusion: In comparision with standard IMRT optimization, MCO reduces the dose of organs at risk with the same PTV coverage,but the result needs further clinical evalution.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-05: Dose Domain Optimization of MLC Leaf Patterns for Highly Complicated 4Ï€ IMRT Plans

Purpose: Highly conformal non-coplanar 4π radiotherapy plans typically require more than 20 intensity-modulated fields to deliver. A novel method to calculate multileaf collimator (MLC) leaf patterns is introduced to maximize delivery efficiency, accuracy and plan quality. Methods: 4 GBM patients, with a prescription dose of 59.4 Gy or 60 Gy, were evaluated using the 4π algorithm using 20 beams. The MLC calculation utilized a least square minimization of the dose distribution, with an anisotropic total variation regularization term to encourage piecewise continuity in the fluence maps. Transforming the fluence to the dose domain required multiplying the fluence with a sparse matrix. Exploiting this property made it feasible to solve the problem using CVX, a MATLAB-based convex modeling framework. The fluence was stratified into even step sizes, and the MLC segments, limited to 300, were calculated. The patients studied were replanned using Eclipse with the same beam angles. Results: Compared to the original 4π plan, the stratified 4π plan increased the maximum/mean dose for, in Gy, by 1.0/0.0 (brainstem), 0.5/0.2 (chiasm), 0.0/0.0 (spinal cord), 1.9/0.3 (L eye), 0.7/0.2 (R eye), 0.4/0.4 (L lens), 0.3/0.3 (R lens), 1.0/0.8 (L Optical Nerve), 0.5/0.3 (R Optical Nerve), 0.3/0.2 (L Cochlea), 0.1/0.1 (R Cochlea), 4.6/0.2 (brain), 2.4/0.1 (brain-PTV), 5.1/0.9 (PTV). Compared to Eclipse, which generated an average of 607 segments, the stratified plan reduced (−) or increased (+) the maximum/mean dose, in Gy, by −10.2/−4.1 (brainstem), −10.5/−8.9 (chiasm), +0.0/−0.1 (spinal cord), −4.9/−3.4 (L eye), −4.1/−2.5 (R eye), −2.8/−2.7 (L lens), −2.1/−1.9 (R lens), −7.6/−6.5 (L Optical Nerve), −8.9/−6.1 (R Optical Nerve), −1.3/−1.9 (L Cochlea), −1.8/−1.8 (R Cochlea), +1.7/−2.1 (brain), +3.2/−2.6 (brain-PTV), +1.8/+0.3 Gy (PTV. The stratified plan was also more homogeneous in the PTV. Conclusion: This novel solver can transform complicated fluence maps into significantly fewer deliverable MLC segments than the commercial system while achieving superior dosimetry. Funding support partially contributed by Varian.

60 APPLIED LIFE SCIENCES↗

SU-D-207-07: Implementation of Full/half Bowtie Filter Model in a Commercial Treatment Planning System for Kilovoltage X-Ray Imaging Dose Estimation

Purpose: To implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) x-ray imaging dose of Varian On-Board Imager (OBI) cone beam CT (CBCT) system. Methods: Full/half bowtie filters of Varian OBI were created as compensator models in Pinnacle TPS (version 9.6) using Matlab software (version 2011a). The profiles of both bowtie filters were acquired from the manufacturer, imported into the Matlab system and hard coded in binary file format. A Pinnacle script was written to import each bowtie filter data into a Pinnacle treatment plan as a compensator. A kV x-ray beam model without including the compensator model was commissioned per each bowtie filter setting based on percent depth dose and lateral profile data acquired from Monte Carlo simulations. To validate the bowtie filter models, a rectangular water phantom was generated in the planning system and an anterior/posterior beam with each bowtie filter was created. Using the Pinnacle script, each bowtie filter compensator was added to the treatment plan. Lateral profile at the depth of 3cm and percent depth dose were measured using an ion chamber and compared with the data extracted from the treatment plans. Results: The kV x-ray beams for both full and half bowtie filter have been modeled in a commercial TPS. The difference of lateral and depth dose profiles between dose calculations and ion chamber measurements were within 6%. Conclusion: Both full/half bowtie filter models provide reasonable results in kV x-ray dose calculations in the water phantom. This study demonstrates the possibility of using a model-based treatment planning system to calculate the kV imaging dose for both full and half bowtie filter modes. Further study is to be performed to evaluate the models in clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-79: A Study of the Effect of Clinical Tumor Volume Displacement On the Dosage of Post Modified Radical Mastectomy Intensity-Modulated Radiation Therapy Plans for Left-Sided Breast Cancer

Purpose: To explore the effect of clinical tumor volume (CTV) displacement on the dosage of intensity-modulated radiation therapy (IMRT) plans for left-sided breast cancer after modified radical mastectomy. Methods: We created 2 sets of IMRT plans based on PTV0.5 and PTV0.7 (with CTV displacement of 0.5cm and 0.7cm respectively) for each of the ten consecutive left-sided breast cancer patients after modified radical mastectomy, and compared the difference in PTV coverage and organ at risk (OAR) sparing between the two groups. And then, we compared the difference in PTV coverage in IMRT plans based on PTV0.5 between the group with properly estimated CTV displacement (presuming the actual CTV displacement was 0.5cm) and the one with underestimated CTV displacement (presuming the actual CTV displacement was 0.7cm). The difference in results between the corresponding two groups was compared using paired-sample t-test. P values less than 0.05 were considered statistically significant. Results: IMRT plans derived from PTV0.5 had more homogenous PTV coverage, and less heart, left lung, right breast, right lung, left humeral head and B-P radiation exposure, as well as less total Mu as compared with the ones stemmed from PTV0.7 (all p<0.05). IMRT plans with appropriate estimation of CTV displacement had better PTV coverage compared with the ones with underestimated CTV displacement (all p<0.01). Conclusion: The IMRT plans with smaller CTV displacement in post modified radical mastectomy radiotherapy for left-sided breast cancer has dosimetrical advantages over the ones with larger CTV displacement. Underestimation of CTV displacement can lead to significant reduction of PTV coverage. Individually quantifying and minimizing CTV displacement can significantly improve PTV coverage and OAR (including heart and left lung) sparing. This work was supported by the Medical Scientific Research Foundation of Guangdong Procvince (A2014455 to Changchun Ma)

60 APPLIED LIFE SCIENCES↗

SU-E-T-96: An Analysis of VMAT SBRT Lung Treatment Plans

Purpose: To present an analysis of 218 lung sbrt treatment plans delivered using Varian Eclipse RapidArc software and delivered with Varian linear accelerators. Methods: A retrospective analysis of treatment plans generated using the Varian Eclipse PRO RapidArc VMAT optimization and AAA photon beam calculation algorithms was done for 218 plans delivered using Varian Trilogy and TrueBeam linear accelerators. Some of the patients were enrolled in the RTOG 0813 and RTOG 0915 lung protocols. All of the patients’ plans were optimized using the guidelines outlined by these protocols. The plans presented were normalized so that 95% of the PTV volume received 100% of the prescribed dose. Results: The dose co formality constraints from the RTOG protocols and the number of plans within those constraints were:Tumor dose between 60% of maximum dose and 90% of maximum: 218/218 = 100%.Volume of 105% tumor dose outside put less than 15% of the PTV volume: 218/218 = 100%.Maximum dose 2 cm away from PTV within protocol table guidelines: No minor deviation: 188/218 = 86.2%. No major deviation: 216/218 = 99.1%.Ratio of 50% dose volume to PTV volume less than R50 in protocol table: No minor deviation 148/218 = 67.9%. No major deviation: 213/218 = 97.7%.Percent of lung receiving 20 Gy less than 10% (no minor violation): 218/218 = 100%.99% of PTV receiving at least 90% of the tumor dose: 214/218 = 98.2%. Conclusion: Varian RapidArc VMAT can successfully deliver lung SBRT treatments as outlined in the RTOG 0813 and 0915 protocols. The largest deviations were seen in the R50 constraints for the larger PTV volumes.

60 APPLIED LIFE SCIENCES↗

SU-E-T-109: An Investigation of Including Variable Relative Biological Effectiveness in Intensity Modulated Proton Therapy Planning Optimization for Head and Neck Cancer Patients

Purpose: The current practice of considering the relative biological effectiveness (RBE) of protons in intensity modulated proton therapy (IMPT) planning is to use a generic RBE value of 1.1. However, RBE is indeed a variable depending on the dose per fraction, the linear energy transfer, tissue parameters, etc. In this study, we investigate the impact of using variable RBE based optimization (vRBE-OPT) on IMPT dose distributions compared by conventional fixed RBE based optimization (fRBE-OPT). Methods: Proton plans of three head and neck cancer patients were included for our study. In order to calculate variable RBE, tissue specific parameters were obtained from the literature and dose averaged LET values were calculated by Monte Carlo simulations. Biological effects were calculated using the linear quadratic model and they were utilized in the variable RBE based optimization. We used a Polak-Ribiere conjugate gradient algorithm to solve the model. In fixed RBE based optimization, we used conventional physical dose optimization to optimize doses weighted by 1.1. IMPT plans for each patient were optimized by both methods (vRBE-OPT and fRBE-OPT). Both variable and fixed RBE weighted dose distributions were calculated for both methods and compared by dosimetric measures. Results: The variable RBE weighted dose distributions were more homogenous within the targets, compared with the fixed RBE weighted dose distributions for the plans created by vRBE-OPT. We observed that there were noticeable deviations between variable and fixed RBE weighted dose distributions if the plan were optimized by fRBE-OPT. For organs at risk sparing, dose distributions from both methods were comparable. Conclusion: Biological dose based optimization rather than conventional physical dose based optimization in IMPT planning may bring benefit in improved tumor control when evaluating biologically equivalent dose, without sacrificing OAR sparing, for head and neck cancer patients. The research is supported in part by National Institutes of Health Grant No. 2U19CA021239-35.

60 APPLIED LIFE SCIENCES↗

SU-E-T-199: Comparison Between Acuros XB and AAA in Homogeneous Phantoms for Volumetric Modulated Arc Therapy Plans

Purpose: To investigate the differences among Acuros XB (AXB) with dose-to-water report mode (AXBw), AXB with dose-to-medium report mode (AXBm) and Anisotropic Analytical Algorithm (AAA), in homogeneous phantoms and for volumetric modulated arc therapy (VMAT) plans. Methods: Nineteen clinically applied VMAT plans were transplanted to a Delta4 phantom and an I’mRT phantom to generate phantom plans, respectively. Each plan was calculated using AXBw, AXBm and AAA, respectively, utilizing the distributed calculation framework (DCF), and the calculation times were recorded. Each plan was delivered by the TrueBeam linear accelerator and measured using the Delta4 phantom and ionization chamber, respectively. The 3D gamma pass rates and point dose deviations were compared among AXBw, AXBm and AAA. Results: In terms of the gamma pass rates with both the criteria of 3 mm/3% (3 mm distance-to-agreement, 3% dose difference) and 2 mm/2%, AXBm demonstrated the significantly worst results, and no significant difference was found between AXBw and AAA. In terms of the point dose, AXBw was slightly closer to the measured dose compared with AAA, and AXBm demonstrated the maximum dose deviation from the measured dose. Moreover, AXB calculation consumed comparable time when the DCF was not busy, and consumed significantly less time when the DCF was busy. Conclusion: In the homogeneous phantoms and for the VMAT plans, AXBw has the best dose accuracy, and AAA is comparable to or slightly worse than AXBw, wheras AXBm has the worst dose accuracy. Furthermore, AXB has higher calculation efficiency than AAA.

60 APPLIED LIFE SCIENCES↗

SU-E-T-284: Dose Plan Optimization When Using Hydrogel Prostate-Rectum Spacer: A Single Institution Experience

Purpose: To describe rectal dose reduction achieved and techniques used to take advantage of the increased peri-rectal spacing provided by injected polyethylene-glycol. Methods: Thirty prostate cancer patents were 2:1 randomized during a clinical trial to evaluate the effectiveness of injected poly-ethylene glycol hydrogel (SpaceOAR System) in creating space between the prostate and the anterior rectal wall. All patients received a baseline CT/MR scan and baseline IMRT treatment plan. Patients were randomized to receive hydrogel injection (n=20) or Control (n=10), followed by another CT/MR scan and treatment plan (single arc VMAT, 6 MV photons, 79.2 Gy, 44 fractions). Additional optimization structures were employed to constrain the dose to the rectum; specifically an avoidance structure to limit V75 <15%, and a control structure to limit the maximum relative dose <105% in the interface region of the anterior rectal wall and the prostate planning target volume. Dose volumetric data was analyzed for rectal volumes receiving 60 through 80 Gy. Results: Rectal dose reduction was observed in all patients who received the hydrogel. Volumetric analysis indicates a median rectal volume and (reduction from baseline plan) following spacer application of 4.9% (8.9%) at V60Gy, 3.8% (8.1%) at V65Gy, 2.5% (7.2%) at V70Gy, 1.6% (5.8%) at V75Gy, and 0.5% (2.5%) at V80Gy. Conclusion: Relative to planning without spacers, rectal dose constraints of 5%, 4%, 3%, 2%, 1% for V60, V65, V70, V75, and V80, should be obtainable when peri-rectal spacers are used. The combined effect of increased peri-rectal space provided by the hydrogel, with strict optimization objectives, resulted in reduced dose to the rectum. To maximize benefit, strict optimization objectives and reduced rectal dose constraints should be employed when creating plans for patients with perirectal spacers. Clinical Trial for SpaceOAR product conducted by Augmenix,Inc. The research site was paid to be a participating site.

60 APPLIED LIFE SCIENCES↗

SU-E-T-311: Dosimetric Comparison of Volumetric Modulated Arc Therapy Plans for Preoperative Radiotherapy Rectal Cancer Using Flattening Filter-Free and Flattening Filter Modes

Purpose: To compare the dosimetric difference of volumetric modulated arc therapy(VMAT) for preoperative radiotherapy rectal cancer using 6MV X-ray flattening filter free(FFF) and flattening filter(FF) modes. Methods: FF-VMAT and FFF-VMAT plans were designed to 15 rectal cancer patients with preoperative radiotherapy by planning treatment system(Eclipse 10.0),respectively. Dose prescription was 50 Gy in 25 fractions. All plans were normalized to 50 Gy to 95% of PTV. The Dose Volume Histogram (DVH), target and risk organ doses, conformity indexes (CI), homogeneity indexes (HI), low dose volume of normal tissue(BP), monitor units(MU) and treatment time (TT) were compared between the two kinds of plans. Results: FF-VMAT provided the lower Dmean, V105, HI, and higher CI as compared with FFF-VMAT. The small intestine of D5, Bladder of D5, Dmean, V40, V50, L-femoral head of V40, R-femoral head of Dmean were lower in FF-VMAT than in FFF-VMAT. FF-VMAT had higher BP of V5, but no significantly different of V10, V15, V20, V30 as compared with FFF-VMAT. FF-VMAT reduceed the monitor units(MU) by 21%(P<0.05), as well as the treatment time(TT) was no significantly different(P>0.05), as compared with FFF-VMAT. Conclusion: The plan qualities of FF and FFF VMAT plans were comparable and both clinically acceptable. FF-VMAT as compared with FFF-VMAT, showing better target coverage, some of OARs sparing, the MUs of FFF-VMAT were higher than FF-VMAT, yet were delivered within the same time. This work was supported by the Medical Scientific Research Foundation of Guangdong Procvince (A2014455 to Changchun Ma)

60 APPLIED LIFE SCIENCES↗

SU-E-T-504: Intensity-Modulated Radiosurgery Treatments Derived by Optimizing Delivery of Sphere Packing Treatment Plans

Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-process dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-772: Uncertainties in Treatment Planning for IROC-Houston Proton Phantom QA Program Due to Variable CT Technique and Proton Energy

Purpose: To understand the uncertainties in proton therapy treatment planning for the IROC- Houston proton phantom QA program due to variations in CT technique and proton energy. Methods: A CT phantom used by IROC-H during therapy site visits was scanned using three CT techniques (80, 120, 140kV) with a CT scanner used for proton therapy simulations and irradiated with a passively scattered beam at three energies (140, 200, 250 MeV) to measure, respectively, HU and Relative Linear Stopping Power (RLSP) in order to create HU to RLSP calibration curves for comparison with reference curves used by current proton treatment planning systems. The phantom has proton equivalent materials with a wide variety of HU and RLSPs to allow for the creation of a calibration curve for common tissue equivalent materials. Treatment plans were created for a lung phantom using the various CT technique/ beam energy calibration curves to determine the differences in the dose distributions by performing a gamma analysis. Results: Comparison of the calibration curves created using the phantom materials showed a maximum difference of 12% for a given material between the custom curve and the reference curve currently used by the treatment planning system. The highest differences were a Result of using an 80 kV CT technique and a 250 MeV high proton energy. A comparison of the completed treatment plans will be presented. Conclusion: These results indicate the possibility of differences in proton HU to RLSP calibration curves caused by varying CT technique and proton energy that could manifest as differences in planned and delivered dose distributions, particularly at high proton energies and low kV CT techniques. These differences could Result in discrepancies not accounted for by IROC-Houston and could possibly affect proton institutions’ pass rate when irradiating the proton phantoms.

60 APPLIED LIFE SCIENCES↗

MO-D-BRB-00: Pediatric Radiation Therapy Planning, Treatment, and Late Effects

Most Medical Physicists working in radiotherapy departments see few pediatric patients. This is because, fortunately, children get cancer at a rate nearly 100 times lower than adults. Children have not smoked, abused alcohol, or been exposed to environmental carcinogens for decades, and of course, have not fallen victim to the aging process. Children get very different cancers than adults. Breast or prostate cancers, typical in adults, are rarely seen in children but instead a variety of tumors occur in children that are rarely seen in adults; examples are germinomas, ependymomas and primitive neuroectodermal tumors, which require treatment of the child’s brain or neuroblastoma, requiring treatment in the abdomen. The treatment of children with cancer using radiation therapy is one of the most challenging planning and delivery problems facing the physicist. This is because bones, brain, breast tissue, and other organs are more sensitive to radiation in children than in adults. Because most therapy departments treat mostly adults, when the rare 8 year-old patient comes to the department for treatment, the physicist may not understand the clinical issues of his disease which drive the planning and delivery decisions. Additionally, children are more prone than adults to developing secondary cancers after radiation. For bilateral retinoblastoma for example, an irradiated child has a 40% chance of developing a second cancer by age 50. The dosimetric tradeoffs made during the planning process are complex and require careful consideration for children treated with radiotherapy. In the first presentation, an overview of childhood cancers and their corresponding treatment techniques will be given. These can be some of the most complex treatments that are delivered in the radiation therapy department. These cancers include leukemia treated with total body irradiation, medulloblastoma, treated with craniospinal irradiation plus a conformal boost to the posterior fossa, neuroblastoma, requiring focal abdominal irradiation to avoid kidney, liver, and vertebral body damage, retinoblastoma, requiring treatment to an eye while minimizing dose to surrounding tissues, and a variety of other tumors which occur anywhere in the body. Case studies will be presented showing the treatment technique and resulting dosimetry, highlighting the objectives for tumor coverage and organ-at-risk sparing. Practical issues that have to be faced when treating children will also be discussed such as daily sedation and immobilization. Late effects based on the current understanding of dose-volume response in normal tissues will be discussed. In the second presentation, specific focus will be on pediatric proton therapy. We will review literature publications on dosimetric comparison of proton versus photon plans, common pediatric tumors treated with protons, and available clinical outcomes. We will describe simulation technique, treatment planning, image guidance for setup verification, and proton beam delivery unique to pediatric and adolescent patients. Finally, we will discuss desired improvements, outlook, and opportunities for medical physicists in pediatric proton therapy. Learning Objectives: Improve understanding about childhood cancer and treatment with radiation Understand treatment planning and delivery issues and associated late effects specific to children Become aware of specific treatment methods for the most challenging pediatric cancers Know the current status, techniques, and desired improvements for pediatric proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampled systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs improvement to achieve clinically equivalent plans.

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

SU-F-T-567: Sensitivity and Reproducibility of the Portal Imaging Panel for Routine FFF QC and Patient Plan Dose Measurements

Purpose: The purpose of this work was to see if the EPID is a viable alternative to other QA devices for routine FFF QA and plan dose measurements. Methods: Sensitivity measurements were made to assess response to small changes in field size and beam steering. QA plans were created where field size was varied from baseline values (5–5.5cm, 20–20.5cm). Beam steering was adjusted by altering values in service mode (Symmetry 0–3%). Plans were measured using the Varian portal imager (aS1200 DMI panel), QA3 (Sun Nuclear), and Starcheck Maxi (PTW). FFF beam parameters as stated in Fogliata et al were calculated. Constancy measurements were taken using all 3 QC devices to measure a MLC defined 20×20cm field. Two clinical SABR patient plans were measured on a Varian Edge linac, using the Portal Dosimetry module in ARIA, and results compared with analysis made using Delta4 (ScandiDos). Results: The EPID and the Starcheck performed better at detecting clinically relevant changes in field size with the QA3 performing better when detecting similar changes in beam symmetry. Consistency measurements with the EPID and Starcheck were equivalent, with comparable standard deviations. Clinical plan measurements on the EPID compared well with Delta4 results at 3%/1mm. Conclusion: Our results show that for FFF QA measurements such as field size and symmetry, using the EPID is a viable alternative to other QA devices. The EPID could potentially be used for QC measurements with a focus on geometric accuracy, such as MLC positional QA, due to its high resolution compared to other QA devices (EPID 0.34mm, Starcheck 3mm, QA3 5mm). Good agreement between Delta4 and portal dosimetry also indicated the EPID may be a suitable alternative for measurement of clinical plans.

60 APPLIED LIFE SCIENCES↗