Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Comparative Assessment of Tactics to Improve Primary Frequency Response Without Curtailing Solar Output in High Photovoltaic Interconnection Grids

Power grid primary frequency response will be significantly impaired by Photovoltaic (PV) penetration increase because of the decrease in inertia and governor response. PV inertia and governor emulation requires reserving PV output and leads to solar energy waste. This paper exploits current grid resources and explores energy storage for primary frequency response under high PV penetration at the interconnection level. Based on the actual models of the U.S. Eastern Interconnection grid and the Texas grid, effects of multiple factors associated with primary frequency response, including the governor ratio, governor deadband, droop rate, fast load response. are assessed under high PV penetration scenarios. In addition, performance of batteries and supercapacitors using different control strategies is studied in the two interconnections. The paper quantifies the potential of various resources to improve interconnection-level primary frequency response under high PV penetration without curtailing solar output.

14 SOLAR ENERGY↗

Solar Bankability Data to Advance Transactions and Access (SB-DATA) Final Technical Report

The DOE project “Solar Bankability Data to Advance Transactions and Access”, known in the solar industry and referred to in this report as “Orange Button”, had project objectives of convening key stakeholder participants in the solar project lifecycle to develop a data taxonomy that meets to the solar industry’s needs for standardized data types for use in solar projects. Additional Orange Button deliverables included the development of an online data exchange to act as a clearinghouse of data that conformed to the data standard and additional solar industry data, and a Solar Data Translation Platform that could transform legacy solar project data to conform to the Orange Button data standard. All of these objectives were achieved. The Smart Electric Power Alliance (SEPA) provided program management, industry participant recruiting and convening, worked with the solar industry to define the scope of the Orange Button data taxonomy, and documented and delivered the taxonomy data requirements to funded project partners to develop both the taxonomy and the data conversion tools. Further efforts included performing extensive industry outreach and awareness to encourage adoption of the Orange Button taxonomy by the solar industry by enumerating the cost saving benefits of using the taxonomy and the public benefit of the increased use of solar energy due to increased bankability and viability of solar development projects. Solar PV panel and component prices have fallen in the last decade, while soft costs have remained stubbornly high and can account for as much as 64% of the total cost of a new solar system. Part of the U.S. Department of Energy SunShot Initiative, Orange Button enabled the creation and adoption of industry-led open data standards for rapid and seamless information exchange across the solar value chain, from origination to decommissioning. Standardizing data will reduce soft costs by making it easier to share solar data and speeding up processes. The taxonomy is a product of solar industry participants convening to identify the pain points caused by incompatible data, and to agree on and standardize data types to be used by the actors in the solar project lifecycle. This report focuses on the SEPA led first phase of Orange Button project that included industry outreach and recruiting participants for five industry working groups, widespread industry outreach to increase awareness and encourage eventual adoption of the taxonomy, and the definition of the scope, use cases, and supporting data types of the Orange Button taxonomy. The solar industry has been receptive of the completed Orange Button taxonomy. In SEPA’s work, 401 solar industry participants facilitated by SEPA defined the scope, use cases, and requirements for the taxonomy leading to over 150 taxonomy early adopters incorporating the taxonomy into their software products serving the solar industry, and several large investors and banks have started projects to enable them to utilize the taxonomy to gain back-office efficiencies. Moving forward, as the solar industry more widely embraces the Orange Button taxonomy and begins realizing the tangible benefits of adoption at scale, we expect further pressure on solar soft costs and increases in the bankability of solar projects.

14 SOLAR ENERGY↗

In-situ X-Ray Analysis of Rapid Thermal Processing for Thin-Film Solar Cells: Closing the Gap between Production and Laboratory Efficiency

For materials synthesis, it is well known that the material final state may not reach equilibrium and depends on the synthetic process. In particular, processes that quickly remove the available energy from the material may leave it in a metastable state and the metastability may actually impart desirable functional properties. By its very nature, Rapid thermal processing (RTP) is ideally suited to produce such metastable materials. However, metastability and the dynamics of reaching a metastable state are poorly understood, since this is best accomplished through in situ monitoring. In this regard, RTP is particularly challenging as the processing time are very short (seconds to minutes). As a result, there is only poor understanding, and hence use, of RTP in industry. This is potentially a cost-increasing limitation, because RTP can decrease cost by decreasing processing time, and as such, increase throughput and decrease the total thermal budget of processing - a significant cost. RTP is already being used for key processing steps in PV technologies. With silicon wafer PV, it is used for establishing electrical contact between the Ag metal grid and the silicon (known as firing). In this process, a silicon wafer with deposited metal/frit in a grid pattern is heated rapidly to temperatures between 750 and 800 ºC. The processing time when the temperature is held above 600ºC is short (<5 seconds). This process has historically been optimized empirically and it is unclear how the thermal processing affects formation of the final contact between the metal and the silicon. In the case of thin-film PV, RTP has been demonstrated in the process of making absorber layers, i.e. CIGS and CZTS. Use of RTP can reduce the processing time from 10s of minutes to seconds, reducing the thermal budget and increasing the throughput significantly. The conversion from precursor material to final PV material is not well understood, and most of the process optimization is done empirically. Again, the proposed in situ monitoring will provide insight into the conversion process. We have developed a unique instrument for in situ monitoring of the reaction process during RTP. The most fundamental property to monitor is the atomic arrangement (for solids, crystalline structure) and thus we have focused on this property. The chamber was designed to collect X-ray diffraction (XRD) for crystal phase determination, although it has lent insight in the formation of liquids. We designed and constructed both inert (air) and reactive (S/Se) versions of this chamber. We have applied the RTP-XRD methodology to: silicon solar cell electrical contact formation; the reaction sequence for forming CIGS PV thin films from copper selenide and indium gallium selenide precursors; the phase sequence for forming HC(NH2)2PbI3 (FAPbI3) and CH3NH3PbI3 (MAPbI3) hybrid-perovskite PV thin films. The RTP instrument enables real-time collection of X-ray diffraction data with intervals as short as 100 ms, and while heating at ramp rates as high 100 ºCs-1 up to 1200 ºC. The system is portable and can be installed on a synchrotron beamline. The RTP reactor consists of a metallic body (front cap assembly, central block and end cap assembly) that houses a quartz reaction chamber. The sample is secured inside the reaction chamber on a sample holder connected to the front-cap assembly. Modifications of the chamber were made for safely handling sulfur and selenium vapor environments. A Se/S source holder was added to generate a Se/S over pressure in the chamber on heating and the entrance window is made wider in order to accommodate the detachable additional holder. Se/S are toxic in nature and therefore a proper Se/S trapping is used before releasing the gases to exhaust. Screen-printing provides an economically attractive means for making Ag electrical contacts to Si solar cells, but the use of Ag substantiates a significant manufacturing cost, and the glass frit used in the paste to enable contact formation contains Pb. To achieve optimal electrical performance and to develop pastes with alternative, abundant, and non-toxic materials requires understanding the contact formation process during firing. We use the RTP-XRD chamber during firing of Ag-Si contacts to reveal the reaction sequence for contact formation. The findings show that between 500 ºC and 650 ºC PbO in the frit etches the SiNx antireflective-coating on the solar cell, exposing the Si surface. Then, above 650 ºC, Ag+ dissolves into the molten glass frit – key for enabling deposition of metallic Ag on the emitter surface and precipitation of Ag nanocrystals within the glass. This clarifies contact formation mechanisms and can be used to suggest approaches for development of inexpensive, nontoxic solar cell contacting pastes. We used the RTP/XRD chamber to study the formation of CuInGaS/Se (CIGS) PV films by in-situ selenization of pre-deposited metal stacks and annealing of pre-deposited Cu-In-Ga-Se precursors. During the metal stack selenization, we observed that Se first reacts with the metals and forms selenides. We observed formation of intermetallics such as Cu2In and binary selenides during heating. On further annealing in a Se atmosphere, CuInSe2 and CuGaSe2 forms which on heating up to 550 °C reacts further to form the CIGS phase. On prolonged exposure to 550 °C for more than 5 mins or higher temperature, we see separation into Ga-rich and Ga-depleted CIGS phases. On introducing a holding step at 400 °C for 10 min during the annealing ramp, the CIGS phase (forms between 500-550 °C), appears to be less prone to decomposition into high-Ga and low-Ga phases during holding at peak temperature. Lead halide perovskites have emerged as successful optoelectronic materials with high photovoltaic power conversion efficiencies and low material cost. However, substantial challenges remain in the scalability, stability and fundamental understanding of the materials. We demonstrated the application of radiative thermal annealing, an easily scalable processing method, for synthesizing formamidinium lead iodide (FAPbI3) perovskite solar absorbers. Devices fabricated from films formed via radiative thermal annealing have equivalent efficiencies to those annealed using a conventional hotplate. By coupling results from in situ x-ray diffraction using a radiative thermal annealing system with device performances, we mapped the processing phase space of FAPbI3 and corresponding device efficiencies. Our map of processing-structure-performance space suggests the commonly used FAPbI3 annealing time, 10 min at 170 °C, can be significantly reduced to 40 s at 170 °C without affecting the photovoltaic performance. Applying the Johnson-Mehl-Avrami model to the decomposition into PbI2, the activation energy was determined. We also presented a well-controlled, manufacturing relevant annealing method, radiative thermal annealing, for the methylammonium lead triiodide films formed by solvent engineering process, with dimethylformamide (DMF) and dimethyl sulfoxide as solvent and diethyl ether as the antisolvent. Radiative thermal annealing can produce high quality perovskite films, evidenced by high efficiency solar cell devices, in a shorter time than the widely-used hotplate annealing. Using in-situ x-ray diffraction during the radiative annealing, we show that the role of the antisolvent is not to form an intermediate compound (a methylammonium iodide, lead iodide, and dimethyl sulfoxide compound) by washing of the main solvent (DMF) but to achieve a pin-hole free, uniform film of methylammonium lead iodide. We find that having the intermediate compound does not guarantee a high quality (pin-hole free) perovskite film. Our study was extended to reveal the effect of annealing environment, annealing temperature profile, and deposition substrate.

36 MATERIALS SCIENCE↗

Uncertainty Analysis of Spectral Irradiance Reference Standards Used for NREL Calibrations

Spectral irradiance produced by lamp standards such as the National Institute of Standards and Technology (NIST) FEL-type tungsten halogen lamps are used to calibrate spectroradiometers at the National Renewable Energy Laboratory. Spectroradiometers are often used to characterize spectral irradiance of solar simulators, which in turn are used to characterize photovoltaic device performance, e.g., power output and spectral response. Therefore, quantifying the calibration uncertainty of spectroradiometers is critical to understanding photovoltaic system performance. In this study, we attempted to reproduce the NIST-reported input variables, including the calibration uncertainty in spectral irradiance for a standard NIST lamp, and quantify uncertainty for measurement setup at the Optical Metrology Laboratory at the National Renewable Energy Laboratory.

14 SOLAR ENERGY↗

Performance assessment of the PNM Prosperity electricity storage project

The purpose of this study is to characterize the technical performance of the PNM Prosperity electricity storage project, and to identify lessons learned that can be used to improve similar projects in the future. The PNM Prosperity electricity storage project consists of a 500 kW/350 kWh advanced lead-acid battery with integrated supercapacitor (for energy smoothing) and a 250 kW/1 MWh advanced lead-acid battery (for energy shifting), and is co-located with a 500 kW solar photovoltaic (PV) resource. The project received American Reinvestment and Recovery Act (ARRA) funding. The smoothing system is e ective in smoothing intermittent PV output. The shifting system exhibits good round-trip efficiencies, though the AC-to-AC annual average efficiency is lower than one might hope. Given the current utilization of the smoothing system, there is an opportunity to incorporate additional control algorithms in order to increase the value of the energy storage system.

25 ENERGY STORAGE↗

Grid tied PV system energy smoothing.

Grid-tied PV energy smoothing was implemented by using a valve regulated lead-acid (VRLA) battery as a temporary energy storage device to both charge and discharge as required to smooth the inverter energy output from the PV array. Inverter output was controlled by the average solar irradiance over the previous 1h time interval. On a clear day the solar irradiance power curve is offset by about 1h, while on a variable cloudy day the inverter output power curve will be smoothed based on the average solar irradiance. Test results demonstrate that this smoothing algorithm works very well. Battery state of charge was more difficult to manage because of the variable system inefficiencies. Testing continued for 30-days and established consistent operational performance for extended periods of time under a wide variety of resource conditions. Both battery technologies from Exide (Absolyte) and East Penn (Advanced Valve Regulated Lead-Acid) proved to cycle well at a partial state of charge over the time interval tested.

14 SOLAR ENERGY↗

Grid-tied PV battery systems.

Grid tied PV energy smoothing was implemented by using a valve regulated lead-acid (VRLA) battery as a temporary energy storage device to both charge and discharge as required to smooth the inverter energy output from the PV array. Inverter output was controlled by the average solar irradiance over the previous 1h time interval. On a clear day the solar irradiance power curve is offset by about 1h, while on a variable cloudy day the inverter output power curve will be smoothed based on the average solar irradiance. Test results demonstrate that this smoothing algorithm works very well. Battery state of charge was more difficult to manage because of the variable system inefficiencies. Testing continued for 30-days and established consistent operational performance for extended periods of time under a wide variety of resource conditions. Both battery technologies from Exide (Absolyte) and East Penn (ALABC Advanced) proved to cycle well at a Partial state of charge over the time interval tested.

25 ENERGY STORAGE↗

Carousel Trackers with 1-Sun or 3-Sun Modules for Commercial Building Rooftops

The goal is lower cost solar electricity. Herein, two evolutional steps are described toward achieving this goal. The first step is to follow the sun with a solar tracker. Herein, a carousel tracker is described for mounting on commercial building flat rooftops in order to produce more kWh per kW relative to fixed PV modules. The second evolutionary improvement is to produce lower cost 3-sun CPV modules where two thirds of the expensive single crystal silicon material is replaced by less expensive mirror material. This paper describes the performance and durability of two prototype installations demonstrating these evolutionary innovations. In the first case, the installation and operation of 2 carousels equipped with traditional flat plate modules is described. In the second case, the operation of a carousel equipped with new 3-sun CPV modules is described. Both systems have been operating as expected for several months through the winter of 2007.

14 SOLAR ENERGY↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Partial Shade Endurance Testing for Monolithic Photovoltaic Modules

In monolithically integrated photovoltaic (PV) modules, including CdTe, CIGS, and a-Si modules, some shadows can cause permanent damage under some operating conditions. This damage reduces efficiency and causes shunts that are visible to the eye and in luminescence imaging. Although these shadows are sometimes forbidden by product documentation, we have observed this type of damage in utility-scale PV systems. Existing standards ensure that qualified modules are safe to use after they are damaged by shadows. But no standard test exists to quantify the loss of efficiency that can result from this damage. In this work we describe new, accelerated tests to quantify the power loss that occurs due to shadows from human bodies and narrow objects, such as tools, placed nearby or directly touching modules. The tests are designed to be easy to conduct uniformly across products and laboratories. The tests can be performed outdoors and last only a few minutes. In our trials on commercial products, these tests resulted in 2%-27% permanent loss in power at standard test conditions (STC). The relative loss was several times larger when measured at lower irradiance. The tests we describe can be used to differentiate products, to direct the development of technological solutions to shadow sensitivity at the cell and module levels, and to establish the need for system-level and administrative solutions to the occurrence of shadows. Similar tests will be the basis of a new International Electrotechnical Commission (IEC) technical specification (TS) 63140.

14 SOLAR ENERGY↗

Improving Distribution System Operations Using Fleet Control of Electrolyzers

The proliferation of electrolyzers presents an opportunity for grid operators. Fast response times and the use of hydrogen as storage can be leveraged in a symbiotic way to support increasing penetration levels of photovoltaics (PV) in the distribution grid. This work presents the grid integration of an electrolyzer fleet and its control applications to minimize the impact of increasing solar PV penetration in the distribution network. The study involves a feeder model of a real utility circuit from a utility partner with an operational model of a fleet of electrolyzers. The operational improvements are quantified with performance metrics. The metrics show that the fleet control application of the electrolyzers can aid in reducing overvoltages, voltage fluctuations, and control device operations induced by intermittent solar generation. The locational dependence of electrolyzers are also discussed in terms of performance metrics.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Shape error analysis for reflective nano focusing optics

Focusing performance of reflective x-ray optics is determined by surface figure accuracy. Any surface imperfection present on such optics introduces a phase error in the outgoing wave fields. Therefore converging beam at the focal spot will differ from the desired performance. Effect of these errors on focusing performance can be calculated by wave optical approach considering a coherent wave field illumination of optical elements. We have developed a wave optics simulator using Fresnel-Kirchhoff diffraction integral to calculate the mirror pupil function. Both analytically calculated and measured surface topography data can be taken as an aberration source to outgoing wave fields. Simulations are performed to study the effect of surface height fluctuations on focusing performances over wide frequency range in high, mid and low frequency band. The results using real shape profile measured with long trace profilometer (LTP) suggest that the shape error of {lambda}/4 PV (peak to valley) is tolerable to achieve diffraction limited performance. It is desirable to remove shape error of very low frequency as 0.1 mm{sup -1} which otherwise will generate beam waist or satellite peaks. All other frequencies above this limit will not affect the focused beam profile but only caused a loss in intensity.

43 PARTICLE ACCELERATORS↗

Resilience and economics of microgrids with PV, battery storage, and networked diesel generators

Current designs and assessments of microgrids have ignored component reliability, leading to significant errors in predicting a microgrid’s performance while islanded. Existing life cycle cost studies on hybrid microgrids—which combine photovoltaics (PV), battery storage and networked emergency diesel generators—also have not identified all the potential economic opportunities. Reducing the number of emergency diesel generators through reliance on PV and battery, retail bill savings, and demand response and wholesale market revenue streams are all important. This paper provides a new statistical methodology that calculates the impact of distributed energy reliability and variability on a microgrid’s performance and a novel use of the optimization platform REopt to explore multiple cost savings and revenue streams. We examine the impacts for microgrids in California, Maryland, and New Mexico and show that a hybrid microgrid is a more resilient and cost-effective solution than a diesel-only system. Under realistic conditions, a hybrid microgrid can provide higher system reliability when islanded and have a lower life cycle cost under multiple market conditions than a traditional diesel generator-based system. The improved performance of the hybrid system is resilient to conditions experienced over the last 20 years in solar irradiance and sees little degradation in performance immediately after a hurricane. The cost savings to provide this more resilient backup power system as compared to a diesel-only microgrid are significant. The net present cost for a hybrid microgrid is 19% lower in New Mexico and 35% lower in Maryland than a diesel-only microgrid. In California, the net present cost of the hybrid microgrid is negative because, unlike a diesel-only microgrid, a hybrid microgrid has lower life cycle costs than the power costs without a microgrid.

25 ENERGY STORAGE↗

Communication enabled – fast acting imbalance reserve (CE-FAIR)

This letter presents a new frequency control strategy that takes advantage of communications and fast responding resources like PV generation, energy storage, wind generation, and demand response, termed collectively as converter interfaced generators (CIGs). The proposed approach uses an active monitoring of power imbalances to rapidly redispatch CIGs. This approach differs from previously proposed frequency control schemes in that it employs feed-forward control based on a measured power imbalance rather that relying on a frequency measurement. As a result, time-domain simulations of the full Western Electricity Coordinating Council (WECC) system are conducted to demonstrate the effectiveness of the proposed method, showing improved performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗

Pascua Yaqui Tribe Energy Audit (Final Report)

The Pascua Yaqui Tribe has the goal of reducing energy use and costs in its government facilities and housing. In a proactive effort to meet the Tribe's needs an energy audit was performed to accomplish the following goals: Develop an energy efficiency implementation strategy. Prepare an energy audit to identify cost-effective energy efficiency opportunities. Plan and conduct a level II energy audit in tribal government buildings and tribal housing. The audit encompassed four tribal government buildings and a group of residential structures. The purpose of this project was to assess the various facilities energy use in order to inform a means to lower annual consumption. An evaluation of each facility's historical energy and major energy-consuming equipment was performed, and energy conservation measures (ECM's) were identified. An average of 4 ECM's where recommended for each facility. If each facility's recommended ECM's are implemented, the average calculated yearly benefits to the government and residential buildings would result in a 48.3% reduction in electrical energy/costs savings and a 14.4% reduction in natural gas energy/costs savings. Recommended projects for implementation include: Interior Lighting Upgrade, Exterior Lighting Upgrade, Solar Pool Covers, Retro-Commissioning, Low Volt Fixtures, Plug Load Management System, Occupancy Sensor Control, and Solar PV for government/casino buildings and appliance, window, HVAC, Weather Stripping, and water heaters replacement in residences.

03 NATURAL GAS↗

The Impact of Utility Tariff Evolution on Behind-the-Meter PV Adoption

This analysis uses a new method to link the NREL Regional Energy Deployment System (ReEDS) capacity expansion model with the NREL distributed generation market demand model (dGen) to explore the impact that the evolution of retail electricity tariffs can have on the adoption of distributed photovoltaics (DPV). The evolution most notably takes the form of decreased mid-day electricity costs, as low-cost PV reduces the marginal cost of electricity during those hours and the changes are subsequently communicated to electricity consumers through tariffs. We find that even under the low PV prices of the new SunShot targets the financial performance of DPV under evolved tariffs still motivates behind-the-meter adoption, despite significant reduction in the costs of electricity during afternoon periods driven by deployment of cheap utility-scale PV. The amount of DPV in 2050 in these low-cost futures ranged from 206 GW to 263 GW, a 13-fold and 16-fold increase over 2016 adoption levels respectively. From a utility planner's perspective, the representation of tariff evolution has noteworthy impacts on forecasted DPV adoption in scenarios with widespread time-of-use tariffs. Scenarios that projected adoption under a portfolio of time-of-use tariffs, but did not represent the evolution of those tariffs, predicted up to 36 percent more DPV in 2050, compared to scenarios that did not represent that evolution. Lastly, we find that a reduction in DPV deployment resulting from evolved tariffs had a negligible impact on the total generation from PV - both utility-scale and distributed - in the scenarios we examined. Any reduction in DPV generation was replaced with utility-scale PV generation, to arrive at the quantity that makes up the least-cost portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recent Photovoltaic Performance Data in the USA (Presentation)

This paper presents performance data from nearly 50,000 Photovoltaic systems totaling 1.7 Gigawatts installed capacity in the USA from 2009 to 2012. 90% of the systems performed to within 10% or better of expected performance. Only 2-4% of the data indicate issues significantly affecting the system performance. Special causes of underperformance and their impacts are delineated by reliability category. Delays and interconnections dominate project-related issues particularly in the first year, but total less than 0.5% of all systems. Hardware-related issues are dominated by inverter problems totaling less than 0.4% and underperforming modules to less than 0.1%.

14 SOLAR ENERGY↗