Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PNNL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Understanding and Constraining the Midlatitude Cloud Optical Depth Feedback in Climate Models (Final Report)

The objectives of this investigation are to provide a deeper understanding of the brightening of middle and high latitude clouds that occurs in many climate models as the climate warms, and to better understand why models give varying estimates of the strength of this negative feedback. The investigation may also provide new information on why models are deficient in their simulation of the present day clouds in these regions. The analysis will reveal which models simulate current clouds most realistically in the regions of interest, and relate this to the strength of the cloud feedbacks in the models. This will improve the uncertainty quantification of climate simulations and will provide theoretical understanding potentially leading to increased reliability of climate change projections. This will enhance the predictive understanding of the Earth system by analyzing the natural and anthropogenic components of global climate change in models. The primary methods involve the study of the clouds in the suite of CMIP5 model climate simulations and comparison of clouds in climate simulations with data from satellite measurement systems, with a particular emphasis on mixed-phase cloud physics, for which ice and water are present simultaneously. State-of-the-art climate model feedback analysis will be combined with new and more comprehensive observations of clouds available from modern measurement systems. Novel use of model simulations in combination with observations enables a deeper understanding of the role of clouds in climate change. Metrics that facilitate model-to-model and model-to-observation comparisons related to mixed-phase cloud physics will be developed and used to highlight challenges and opportunities for improving the state-of-the-science models. This investigation is a collaboration between the University of Washington, where the data work is concentrated and LLNL where the model data and the tools and expertise to do cloud feedback analysis are located. The grant supported the work of 3 different graduate students at different times (McCoy, Wall and Berry) Post-doctoral researcher Blaž Gasparini was also partially supported on this grant and led our collaboration with PNNL scientists. PNNL scientists also collaborated in the work of graduate student Wall (Po-Lun Ma). The main results of our research efforts are reported in 6 papers and 1 book chapter that were supported by this grant.

54 ENVIRONMENTAL SCIENCES↗

Illinois Distributed Generation Rebate Calculation Considerations

What is the value of distributed generation to the distribution system and how do we assign that value to a rebate? This white paper provides a preliminary look at the potential distributed generation valuation and compensation options for Illinois, taking into consideration data needs and availability, as well as stakeholder input. Pacific Northwest National Laboratory (PNNL) is supporting the Illinois Commerce Commission (ICC) with initial stakeholder engagement to advance the conversation around distributed generation valuation in Illinois. PNNL’s educational support will help set the stage for a productive formal process as the ICC will be called upon, in relatively short order, to start formal distributed generation valuation proceedings in response to Illinois Public Act 99-0906, also known as the Future Energy Jobs Act (FEJA), and codified in Illinois Public Utilities Act Section 16-107.6.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Processing and Characterization of Pilgered 14YWT Tubing

The Nuclear Technology Research & Development program of the Office of Nuclear Energy has implemented a program to develop an advanced reactor cladding fabrication capability by using the extrusion and pilgering processes. Oxide-dispersion strengthened (ODS) steels are a promising class of advanced materials, but processes need to be developed to produce tubing for these advanced alloys. The Pacific Northwest National Laboratory (PNNL) has converted its rolling mill into a lab-scale pilger mill, which required designing pilger tooling and rolls that contained multiple pilgering grooves and designing a servo-driven feed mechanism. Upon assembling and checking out the system, pilgering runs on stainless steel, MA956, and 14YWT iron (Fe)-based alloys were completed. Once the feed rates and rotation rates were established, the reduction schedules were determined. This report will focus on the processing and characterization of pilgered 14YWT thin-wall tubing that was processed from an extruded thick-wall tube using the PNNL laboratory pilger rolling mill. Characterization included optical metallography of the pilgered tube and microhardness of the processed material. The 14YWT characterization is being done in cooperation with researchers at Los Alamos National Laboratory (LANL), with LANL performing mechanical property testing of pilgered 14YWT and 14YWT tubes produced by hydrostatic extrusion at Case Western Reserve University (CWRU).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Army Re-tuning™ Implementation Guides

The Army is a large, geographically dispersed organization with 156 installations and over 980 million square feet of building space to operate and maintain. The building stock spans a wide range of vintages and missions, with many serving cross-cutting functions and purposes. To meet Federal mandates and reduction goals organizationally, in recent years the Army has aggressively pursued policy and energy efficiency projects and programs resulting in a 9.6% reduction in energy use intensity (EUI) from fiscal year (FY) 2015 to FY2017. Despite these successes, the Army remains the largest consumer of electricity in the Federal government and spent approximately $1.1 billion in energy-related costs in FY2017 The Pacific Northwest National Laboratory (PNNL), in support of the Assistant Secretary of the Army (Installations, Energy and Environment) (ASA (IE&E)), was tasked with a multi-year study and pilot demonstration to develop a business case for the potential energy and cost reduction benefits from re-tuning™ efforts for the Army. Re tuning is a systematic process aimed at minimizing building energy consumption by identifying and correcting operational problems that plague buildings. The methodology was developed by PNNL research staff in an effort to improve building operational efficiency at no- or low-cost, primarily through building automation system (BAS) controls. The methodology is based on two basic principles: If the equipment is not needed, turn it off; and if the equipment is not needed at full power, turn it down. Implementation of identified low-cost/no-cost operational improvements through the re-tuning process results in increased building energy efficiency, reduced operating costs, and improvement to occupant comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Iodide on Radiolytic Hydrogen Peroxide Generation

This report fulfills the milestone (M4SF-17PN010501041 Report on Radiolysis Modeling for the Defense Repository) to discuss continued integration of the PNNL Radiolysis Model and the ANL Mixed Potential Model. This work concerns the development of an integrated Radiolysis Model (RM) for evaluating defense waste materials (oxide and metal) degradation and radionuclide mobilization. Within an anoxic repository environment, primary oxidizing species (e.g., hydrogen peroxide (H 2 O 2 ), OH• radicals, as well as chlorate and other oxidizing species depending on the disposal environment) will be generated at the surface of the nuclear waste forms as a function of their specific activity. RM development has included expansion of chemical environments considered to encompass species for various disposal environments. PNNL has been coordinating this effort with ANL on the integration of the radiolysis work with the fuel degradation model. In this study, we demonstrate and approximate possible effects of iodide on H 2 O 2 generation. As has been shown these are conditions for which H 2 O 2 generation is reduced. We find that the presence of the iodide ion reduces the steady-state H 2 O 2 concentration, but not to the same degree as bromide at micro-molar concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Tunable Lighting in Classrooms: Trial LED lighting systems in three classrooms in the Folsom Cordova Unified School District (Supplemental Report)

This report summarizes the results from a trial installation of light-emitting diode (LED) lighting systems installed in three classrooms at Gold Ridge Elementary (GRE) School in the Folsom Cordova Unified School District (FCUSD) in Folsom, CA. FCUSD asked the Sacramento Utility District (SMUD) to help them explore potential benefits of tunable-white lighting systems for children with Autism Spectrum Disorder (ASD). SMUD responded by implementing a research project and invited Pacific Northwest National Laboratory (PNNL) to document the performance of the LED lighting systems as part of a GATEWAY evaluation. SMUD and FCUSD staff coordinated and completed the design and installation of the LED systems, and coordinated the collection of data from teachers, students, and parents, while PNNL evaluated the energy and photometric performance of the systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Composite Analysis for Low Level Waste Disposal in the Central Plateau of the Hanford Site (FY2019 Annual Status Report)

In accordance with DOE M 435.1-1 requirements and as implemented by DOE/RL-2000-29, the U.S. Department of Energy (DOE), Richland Operations Office has prepared this annual summary for fiscal year (FY) 2019. Originally reported in PNNL-11800 and PNNL-11800, Addendum 1, the Hanford Site Composite Analysis was approved through issuance of a 2002 memorandum. As required by DOE/RL-2000-29, an annual evaluation of new information and data developed by a number of onsite programs was completed. The reporting period for this annual evaluation is FY 2019 (October 1, 2018, through September 30, 2019). The information provided in this evaluation includes activities performed in FY 2019 that are considered pertinent to the Hanford Site Composite Analysis - information that could change source terms considered, and monitoring, research, and development results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2020 Review Panel Workshop on Energy Intensity Indicators: Summary Findings and Meeting Notes

On January 28-29, 2020, the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), in coordination with Pacific Northwest National Laboratory (PNNL), sponsored an expert workshop focused on energy intensity indicators. The intent of the workshop was to support a comprehensive review of the EERE Energy Intensity Indicators (EII), a national system of indicators used to track changes in the energy intensity of economic sectors. One goal of the workshop was to gather input from a panel of experts who have experience and knowledge related to the EII methodological approach and key data sources used to calculate indicators for each of the end-use sectors of the economy—transportation, residential, commercial, industrial, and electricity. The current EERE EII methodology is documented in a 2017 PNNL report, A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends, which is available online. The workshop also included a presentation by Dr. Beng Ang, who discussed the Log Mean Divisia index (LMDI) approach to decomposition analysis, which was followed by a discussion concerning the methodological approaches that could be applied to future EII efforts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

General Analysis of Data Collected from DOE Lidar Buoy Deployments Off Virginia and New Jersey

Pacific Northwest National Laboratory (PNNL) operates two AXYS WindSentinel lidar buoys for the U.S. Department of Energy’s Wind Energy Technologies. The purpose of these buoys is to collect hub-height winds and supporting meteorological and oceanographic information to facilitate the development of offshore wind energy in the U.S. In general, each buoy is deployed for a year or more at a given location in order to capture at least a full annual cycle of weather conditions. The initial deployment for one buoy was off the coast of Virginia beginning in 2015, and the other buoy was first deployed off the coast of New Jersey beginning in 2016. Over the last two years, PNNL has had an opportunity to analyze the data collected during these first two deployments. This report describes a substantial analysis of data collected by the two lidar buoys operated off the coasts of Virginia and New Jersey. The centerpiece instrument for each buoy as deployed off Virginia and New Jersey is a lidar system, which is designed to measure the horizontal wind vector from approximately 40 m to 200 m above the sea surface with vertical resolution of 40 m. Since the initial deployments, the original lidars have been replaced with more powerful Leosphere 866 v2 systems. The analyses in this report will apply to the original Vindicator systems. In addition to the wind profiles from the lidars, the buoys collect near-surface measurements of wind speed and direction, air temperature, relative humidity, barometric pressure, and solar irradiance. Oceanographic variables measured include the two-dimensional wave spectrum, water temperature and conductivity, and ocean current vectors to a depth of 90 m. An assessment of overall data recovery and a basic analysis of the data collected was provided in a previous report This report substantially extends that analysis. The various sections describe the development and application of an inertial measurement unit (IMU) data recovery scheme for the New Jersey deployment; a climatological analysis of winds at hub height and at the surface together with thermodynamic variables measured at the surface for the full deployment periods; an analysis of oceanographic observations describe sea state; the development of a refinement for NOAA’s WaveWatch III model to allow its application to near-shore areas; a basic climatology of ocean currents observed from the buoys; an analysis of observed winds in the framework of Monin-Obukhov Similarity Theory; and the development and evaluation of techniques to extract turbulence intensity and turbulence kinetic energy from the lidars. The analyses contained in this report provide a great deal of new information about offshore conditions on the U.S. East Coast. In addition, the experience gained will inform both configurations and analysis of data from future deployments of these lidar buoy systems.

17 WIND ENERGY↗

Energy Saving Quantification on Ductless Heat Pump (DHP) in Existing Homes

In residential retrofit applications, ductless mini-split heat pumps (DHP) are often reported to have high-energy savings potential, depending on the system they are supplementing or replacing. However, recently, there have been a number of utility studies and analyses indicating these energy savings are not being achieved when the existing system is left in place for backup heating or air conditioning. The Pacific Northwest National Laboratory conducted a three-phase project to help determine which control strategies would have the most energy savings impact in various climate zones around the United States. The first phase developed the standalone simulation model for the PNNL Lab Homes and investigated the energy-saving potential from different control strategies and HVAC system configurations. The second phase focused on conducting experiments in the PNNL Lab Homes, which tested the most promising solutions that were modeled in the first phase. The third phase used the field data to calibrate the simulation model and then extrapolated the results to different climate locations and different building sizes. This report focuses on the third phase of the study, including five major parts: model calibration, parametric model setup, results, a sensitivity analysis of air leakage rate, and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mercury Speciation and Quantification of Hanford 241-AP-107 Tank Waste Feed and Treated Samples

This report describes the second phase of a multi year project to adapt and develop an analytical technique for the low-level determination of total mercury (HgT), elemental mercury (Hg0), and monomethyl mercury (MeHg, hereafter referred to as methyl mercury) in Hanford tank waste. The focus of Phase II was to quantify the mercury (Hg) species total, elemental, and methyl mercury from a raw sample and treated (i.e., filtered and cesium-decontaminated) waste samples originating from Hanford waste tank 241-AP 107. The focus of Phase I work was to determine if mercury species can be preconcentrated from aqueous Hanford tank waste solution onto a solid adsorbent while simultaneously eliminating or very significantly reducing the parent radionuclide activity. This was demonstrated by developing protocols for the preparation, separation, and collection of total mercury and methyl mercury onto solid adsorbents, then measuring the adsorbents for radiological content at Pacific Northwest National Laboratory’s (PNNL’s) Radiochemical Processing Laboratory (RPL) on the Hanford Site. During Phase II, the Hanford tank waste material was preserved, separated (through distillation or digestion), then collected as either solid adsorbents or into liquid distillate form at the RPL and transferred to the PNNL Marine Sciences Laboratory (MSL) in Sequim, Washington, for analysis and quantification. Quantification of total, elemental, and methyl mercury was conducted under radiological control at the MSL using the ultra trace analytical capabilities available there.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser Ablation, Absorbance Ratio Spectrometry (LAARS) Assay Performance Study (FY2018 Annual Report)

The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. Pacific Northwest National Laboratory (PNNL) is developing one such tool, called the Laser Ablation, Absorbance Ratio Spectrometry (LAARS) technology, which is designed to provide high-fidelity 235 U/ 238 U isotope ratio measurements to support either on-site enrichment plant or off-site laboratory destructive assay (DA). Analyzing uranium hexafluoride (UF 6 ) DA samples on-site by LAARS could provide early indication of discrepancies with operator declarations during physical inventory verifications, so that such discrepancies could be addressed immediately, rather than after off-site analysis is completed. The IAEA is also seeking on-site DA options, because sample shipping time can be long and evolving restrictions on radioactive/corrosive material shipments may increasingly limit the IAEA’s ability to easily transport UF 6 samples. Routine on-site LAARS analysis could provide timely assay results and reduce the DA sample shipment inventory to just those needed for more definitive determination. A laboratory-based LAARS instrument could also provide rapid, cost-effective prescreening of selected DA samples shipped to the IAEA’s Nuclear Materials Laboratory in Seibersdorf, Austria. PNNL has also developed a complementary UF 6 sampling technology and method, called the Single-Use Destructive Assay (SUDA) sampler to easily collect DA samples that are ideal for on-site analysis by LAARS. Combining the LAARS and SUDA sampler technologies could provide a powerful new on-site DA option for the IAEA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brief Update on Advancements by Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction

In 2011, Pacific Northwest National Laboratory (PNNL), working as a partner in the National Advanced Biofuels Consortium, issued a report assessing the viable industrial feed system and pump options for a 2000 dry metric tons per day production-scale hydrothermal liquefaction (HTL) plant (Berglin et al. 2012). This report was issued as PNNL-21981, Review and Assessment of Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction, and will be referred to as “Pump Survey” for reference. It had the following scope: • Identify relevant applications and industries operating at comparable scales • Interact with commercial vendors and pursue integration between vendors • Take advantage of commercial off-the-shelf (COTS) technology • Supply and support vendor needs for biomass feedstock rheology characterization • Provide vendors with process requirements to support selection of conceptual design for feedstock handing and pump system • Obtain cost data to the extent possible from equipment vendors to support the technical economic analysis (TEA) • Identify issues associated scale-up. The current document represents an update to the prior report in order to: 1. Identify advancements in vendor-reported technologies 2. List reports of new experience or trials with biomass pumping applications 3. Determine if technology/application gaps identified in the prior report have been filled 4. Capture ideas on future research.

09 BIOMASS FUELS↗

Collaborative Research and Development Program on Explosive Detection Technology

In September 2013, at the 6th Permanent Coordinating Group Meeting between the U.S Department of Energy (DOE) and the French Institut de Radioprotection et de Sureté Nucléaire (IRSN), France expressed an interest in bilateral cooperation with the United States because its newly revised regulations that require enhanced explosives detection capabilities at nuclear and radiological facilities. In the ensuing years, PNNL (DOE/NNSA) and IRSN sought to identify an area of collaboration within explosives detection that would leverage the specific technical strengths of each organization. Based upon awareness of each other’s technical acumen gleaned from the scientific literature on explosives detection, it was clear that specific organizations within each nation could provide the needed expertise to enable enhancement of explosives detection through a collaborative development effort. The French lnstitut Saint-Louis was determined to be an optimal partner for IRSN to develop a collaboration with DOE/NNSA using PNNL’s detection team in this effort. Thus, the dialog was started between the technical experts at each organization to define where complementary expertise in explosives detection could be best leveraged. The technical plans and objectives of this project were sound with promising results. In the end, the joint action sheet was not implemented. The challenge with executing the project was in the complexity of getting a signed agreement between DOE, IRSN and ISL. Most of the obstacles surrounded the ability to protect intellectual property and obtain an agreement which included all of the parties. At a high level, this report documents the interactions and attempt to develop a cooperative framework for explosives detection development from FY 2014 through FY 2020.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Characterization Report for the MP-1 Experiment Fabrication Campaign

This report covers the results of MP 1 fuel characterization analysis to provide a detailed understanding of the as-fabricated fuel that would be irradiated in the MP 1 (Mini-Plate 1) experiment. The work was performed at Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL). Characterization of the as-fabricated fuel was performed in accordance with Characterization Plan for the Fabrication of U 10Mo for the MP 1 Experiment, hereinafter the MP 1 Characterization Plan (MAQP 2016). Under the MP 1 Characterization Plan, fuel foils at different points in the foil fabrication process (e.g., hot rolled annealed, cold rolled annealed) were studied to understand the effect of various thermomechanical processes on the fuel microstructure. Samples were sent to each of the three organizations so that testing and analysis could be performed independently using similar equipment and a standardized set of measurement and analysis procedures. The MP 1 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare independently obtained results, and achieve a three-way validation. PNNL characterized 28 uranium–10 wt% molybdenum (U 10Mo) samples. Six pieces/specimens from each sample/foil were sectioned, in accordance with the MP 1 Characterization Plan. Similarly, INL and LANL also examined 24 and 17 U 10Mo specimens, respectively. These total 69 samples consist of six types of MP 1 characterization foils fabricated by Babcock and Wilcox Technologies (BWXT) from ingots produced by the Y-12 National Security Complex: • 0.047 in.-thick hot-rolled and annealed samples with and without Zr layers • 0.02 in.-thick cold-rolled and annealed samples with and without Zr layers • 0.01 in.-thick cold-rolled and annealed samples with and without Zr layers. Microstructure, chemical composition, carbide morphology, U 10Mo foil thickness, Zr thickness, mechanical properties (microhardness), and density were evaluated in both longitudinal and transverse directions for foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy and Energy Cost Savings Analysis of the IECC for Commercial Buildings

The purpose of this analysis is to assess the relative energy and energy cost performance of commercial buildings designed to meet the requirements found in the commercial energy-efficiency provisions of the International Energy Conservation Code (IECC). Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. As many states have historically adopted the IECC for both residential and commercial buildings, PNNL has evaluated the impacts of the commercial provisions of the 2006, 2009, and 2012 editions of the IECC. PNNL also compared energy performance with corresponding editions of ANSI/ASHRAE/IES Standard 90.1 to help states and local jurisdictions make informed decisions regarding model code adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗