Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOGRAPH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Fast camera studies at an electron cyclotron resonance table plasma generator

A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the “big” ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

The solar neighborhood. XXXV. Distances to 1404 M dwarf systems within 25 PC in the southern sky

We present trigonometric, photometric, and photographic distances to 1748 southern (δ⩽0{sup ∘}) M dwarf systems with μ⩾0{sub ⋅}{sup ′′}18 yr{sup −1}, of which 1404 are believed to lie within 25 pc of the Sun. The stars have 6.67⩽V{sub J}⩽21.38 and 3.50⩽(V{sub J}−K{sub s})⩽9.27, covering the entire M dwarf spectral sequence from M0.0 V through M9.5 V. This sample therefore provides a comprehensive snapshot of our current knowledge of the southern sky for the nearest M dwarfs that dominate the stellar population of the Galaxy. Roughly one-third of the 1748 systems, each of which has an M dwarf primary, have published high quality parallaxes, including 179 from the REsearch Consortium On Nearby Stars astrometry program. For the remaining systems, we offer photometric distance estimates that have well-calibrated errors. The bulk of these (∼700) are based on new V{sub J}R{sub KC}I{sub KC} photometry acquired at the CTIO/SMARTS 0.9 m telescope, while the remaining 500 primaries have photographic plate distance estimates calculated using SuperCOSMOS B{sub J}R{sub 59F}I{sub IVN} photometry. Confirmed and candidate subdwarfs in the sample have been identified, and a census of companions is included.

79 ASTRONOMY AND ASTROPHYSICS↗

Younger facial looks are associate with a lower likelihood of several age-related morbidities in the middle-aged to elderly

Abstract Background Looking older for one’s chronological age is associated with a higher mortality rate. Yet it remains unclear how perceived facial age relates to morbidity and the degree to which facial ageing reflects systemic ageing of the human body. Objectives To investigate the association between ΔPA and age-related morbidities of different organ systems, where ΔPA represents the difference between perceived age (PA) and chronological age. Methods We performed a cross-sectional analysis on data from the Rotterdam Study, a population-based cohort study in the Netherlands. High-resolution facial photographs of 2679 men and women aged 51.5–87.8 years of European descent were used to assess PA. PA was estimated and scored in 5-year categories using these photographs by a panel of men and women who were blinded for chronological age and medical history. A linear mixed model was used to generate the mean PAs. The difference between the mean PA and chronological age was calculated (ΔPA), where a higher (positive) ΔPA means that the person looks younger for their age and a lower (negative) ΔPA that the person looks older. ΔPA was tested as a continuous variable for association with ageing-related morbidities including cardiovascular, pulmonary, ophthalmological, neurocognitive, renal, skeletal and auditory morbidities in separate regression analyses, adjusted for age and sex (model 1) and additionally for body mass index, smoking and sun exposure (model 2). Results We observed 5-year higher ΔPA (i.e. looking younger by 5 years for one’s age) to be associated with less osteoporosis [odds ratio (OR) 0.76, 95% confidence interval (CI) 0.62–0.93], less chronic obstructive pulmonary disease (OR 0.85, 95% CI 0.77–0.95), less age-related hearing loss (model 2; B = −0.76, 95% CI −1.35 to −0.17) and fewer cataracts (OR 0.84, 95% CI 0.73–0.97), but with better global cognitive functioning (g-factor; model 2; B = 0.07, 95% CI 0.04–0.10). Conclusions PA is associated with multiple morbidities and better cognitive function, suggesting that systemic ageing and cognitive ageing are, to an extent, externally visible in the human face.

Mekić, Selma↗

Blast from the past: constraining progenitor models of SN 1972E

ABSTRACT We present a novel technique to study Type Ia supernovae (SNe Ia) by constraining surviving companions of historical extragalactic SN by combining archival photographic plates and Hubble Space Telescope(HST) imaging. We demonstrate this technique for Supernova 1972E, the nearest known SN Ia in 125 yr. Some models of SNe Ia describe a white dwarf with a non-degenerate companion that donates enough mass to trigger thermonuclear detonation. Hydrodynamic simulations and stellar evolution models show that these donor stars will survive the explosion, and show increased luminosity for at least a 1000 yr. Thus, late-time observations of the exact location of a supernova can constrain the presence of a surviving donor star and progenitor models. We find the explosion site of SN 1972E by analysing 17 digitized photographic plates taken with the European Southern Observatory 1-m Schmidt and 1 plate taken with the Cerro Tololo Inter-American Observatory 1.5-m telescope. Using the Gaia eDR3 catalogue to determine Supernova 1972E’s location yields: α = 13h39m52${_{.}^{\rm s}}$708 ± 0${_{.}^{\rm s}}$004 and δ = −31°40’9${_{.}^{\prime\prime}}$00 ± 0${_{.}^{\prime\prime}}$04 (ICRS). In 2005, HST/ACS imaged the host galaxy of SN 1972E with the F435W, F555W, and F814W filters covering the explosion site. The nearest detected source is offset by 3.0 times our positional precision, and is inconsistent with the colours expected of a surviving donor star. Thus, the limiting magnitude of the HST observation (F555W > 28 mag) rules out all He star companion models and the most luminous main-sequence companion model currently in the literature. The remaining main-sequence companion models could be tested with a 10 orbit HST exposure in the F606W filter.

Do, Aaron↗

On the nature of apparent transient sources on the National Geographic Society–Palomar Observatory Sky Survey glass copy plates

Abstract We examine critically recent claims for the presence of above-atmosphere optical transients in publicly available digitized scans of Schmidt telescope photographic plate material derived from the National Geographic Society–Palomar Observatory Sky Survey. We employ the publicly available SuperCOSMOS Sky Survey catalogues to examine statistically the morphology of the sources. We develop a simple, objective, and automated image classification scheme based on a random forest decision tree classifier. We find that the putative transients are likely to be spurious artefacts of the photographic emulsion. We suggest a possible cause of the appearance of these images as resulting from the copying procedure employed to disseminate glass copy survey atlas sets in the era before large-scale digitization programmes.

Hambly, N. C. (ORCID:0000000299019064)↗

Autoindexing the diffraction patterns from crystals with a pseudotranslation

Lattice patterns containing alternating strong and weak reflections can be identified by a targeted search for the weak signals, permitting a wider range of diffraction patterns to be indexed automatically. Rotation photographs can be readily indexed if enough candidate Bragg spots are identified to properly sample the reciprocal lattice. However, while automatic indexing algorithms are widely used for macromolecular data processing, they can produce incorrect results in special situations where a subset of Bragg spots is systematically overlooked. This is a potential outcome in cases where a noncrystallographic translational symmetry operator closely mimics an exact crystallographic translation. In these cases, a visual inspection of the diffraction image will reveal alternating strong and weak reflections. However, reliable detection of the weak-intensity reflections by software requires a systematic search for a diffraction signal targeted at specific reciprocal-space locations calculated a priori by considering all possible pseudotranslations. Care must be exercised to distinguish between true lattice diffraction and spurious signals contributed by neighboring overlapping Bragg spots, non-Bragg diffraction and noise. Such procedures have been implemented within the autoindexing program LABELIT and applied to known cases from publicly available data sets. Routine use of this type of signal search adds only a few seconds to the typical run time for autoindexing. The program can be downloaded from http://cci.lbl.gov/labelit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Automated identification of retinal vessels using a multiscale directional contrast quantification (MDCQ) strategy

Purpose: A novel algorithm is presented to automatically identify the retinal vessels depicted in color fundus photographs. Methods: The proposed algorithm quantifies the contrast of each pixel in retinal images at multiple scales and fuses the resulting consequent contrast images in a progressive manner by leveraging their spatial difference and continuity. The multiscale strategy is to deal with the variety of retinal vessels in width, intensity, resolution, and orientation; and the progressive fusion is to combine consequent images and meanwhile avoid a sudden fusion of image noise and/or artifacts in space. To quantitatively assess the performance of the algorithm, we tested it on three publicly available databases, namely, DRIVE, STARE, and HRF. The agreement between the computer results and the manual delineation in these databases were quantified by computing their overlapping in both area and length (centerline). The measures include sensitivity, specificity, and accuracy. Results: For the DRIVE database, the sensitivities in identifying vessels in area and length were around 90% and 70%, respectively, the accuracy in pixel classification was around 99%, and the precisions in terms of both area and length were around 94%. For the STARE database, the sensitivities in identifying vessels were around 90% in area and 70% in length, and the accuracy in pixel classification was around 97%. For the HRF database, the sensitivities in identifying vessels were around 92% in area and 83% in length for the healthy subgroup, around 92% in area and 75% in length for the glaucomatous subgroup, around 91% in area and 73% in length for the diabetic retinopathy subgroup. For all three subgroups, the accuracy was around 98%. Conclusions: The experimental results demonstrate that the developed algorithm is capable of identifying retinal vessels depicted in color fundus photographs in a relatively reliable manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objective assessment in digital images of skin erythema caused by radiotherapy

Purpose: Skin toxicity caused by radiotherapy has been visually classified into discrete grades. The present study proposes an objective and continuous assessment method of skin erythema in digital images taken under arbitrary lighting conditions, which is the case for most clinical environments. The purpose of this paper is to show the feasibility of the proposed method. Methods: Clinical data were gathered from six patients who received carbon beam therapy for lung cancer. Skin condition was recorded using an ordinary compact digital camera under unfixed lighting conditions; a laser Doppler flowmeter was used to measure blood flow in the skin. The photos and measurements were taken at 3 h, 30, and 90 days after irradiation. Images were decomposed into hemoglobin and melanin colors using independent component analysis. Pixel values in hemoglobin color images were compared with skin dose and skin blood flow. The uncertainty of the practical photographic method was also studied in nonclinical experiments. Results: The clinical data showed good linearity between skin dose, skin blood flow, and pixel value in the hemoglobin color images; their correlation coefficients were larger than 0.7. It was deduced from the nonclinical that the uncertainty due to the proposed method with photography was 15%; such an uncertainty was not critical for assessment of skin erythema in practical use. Conclusions: Feasibility of the proposed method for assessment of skin erythema using digital images was demonstrated. The numerical relationship obtained helped to predict skin erythema by artificial processing of skin images. Although the proposed method using photographs taken under unfixed lighting conditions increased the uncertainty of skin information in the images, it was shown to be powerful for the assessment of skin conditions because of its flexibility and adaptability.

60 APPLIED LIFE SCIENCES↗

Strange multibaryon states with Λ hyperon systems in pA collision at 10 GeV/c

Experimental data from the 2m propane bubble chamber have been analyzed for exotic baryon states search. A number of peculiarities were found in the effective mass spectra of Λπ{sup +} (Σ*{sup +} (1382), PDG), Λp, and Λpp subsystems. A few events detected on the photographs of the propane bubble chamber exposed to a 10 GeV/c proton beam were interpreted as S = −2H{sup 0} light(<M{sub (ΛΛ)}) and heavy H{sup 0,+}. A new event detected on the photographs of the propane bubble chamber was interpreted as heavy H{sup +} (2488) dibaryon by weak decay channels of K{sup −} pp or Σ{sup +} pπ{sup −}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical observation of shock waves and cavitation bubbles in high intensity laser-induced shock processes

We report an experimental study of the temporal and spatial dynamics of shock waves, cavitation bubbles, and sound waves generated in water during laser shock processing by single Nd:YAG laser pulses of nanosecond duration. A fast ICCD camera (2 ns gate time) was employed to record false schlieren photographs, schlieren photographs, and Mach-Zehnder interferograms of the zone surrounding the laser spot site on the target, an aluminum alloy sample. We recorded hemispherical shock fronts, cylindrical shock fronts, plane shock fronts, cavitation bubbles, and phase disturbance tracks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field Fourier ptychography: super-resolution phase retrieval via speckle illumination

High spatial resolution is the goal of many imaging systems. While designing a high-resolution lens with diffraction-limited performance over a large field of view remains a difficult task, creating a complex speckle pattern with wavelength-limited spatial features is easily accomplished with a simple random diffuser. With this observation and the concept of near-field ptychography, we report a new imaging modality, termed near-field Fourier ptychography, which is to be used for high-resolution imaging challenges in both microscopic and macroscopic imaging settings. 'Near-field' refers to placing the object at a short defocus distance with a large Fresnel number. We predict a speckle pattern with fine spatial features on the object instead of directly resolving the spatial features via a high-resolution lens. We then translate the object (or speckle) to different positions and acquire the corresponding images by using a low-resolution lens. A ptychographic phase retrieval process is used to recover the complex object, the unknown speckle pattern, and the coherent transfer function at the same time. In a microscopic imaging setup, we use a 0.12 numerical aperture (NA) lens to achieve an NA of 0.85 in the reconstruction process. In a macroscale photographic imaging setup, we achieve similar to 7-fold resolution gain by using a photographic lens. The collection optics do not determine the final achievable resolution; rather, the speckle pattern's feature size does. This is similar to our recent demonstration in fluorescence imaging settings (Guo et al., Biomed. Opt. Express , 9(1), 2018). The reported imaging modality can be utilized in light, coherent X-ray, and transmission electron imaging systems to increase resolution and provide quantitative absorption and object phase contrast.

42 ENGINEERING↗

Temporal Study 2021-2022: Sensor-Based Time Series of Surface Water Temperature, Specific Conductance, Total Dissolved Solids, Turbidity, pH, and Dissolved Oxygen from across Multiple Watersheds in the Yakima River Basin in Washington, USA (v2)

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides periodic (weekly or biweekly) in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata collected at six sites within multiple rivers in the Yakima River Basin in Washington, USA. In addition to the sensor data, there are plots of continuous in situ sensor data and R scripts used to generate the plots. Related sample-based water chemistry data are published separately at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912.The data package was originally published in September 2022. It was updated in June 2025 (v2; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one main data folder containing two sensor-specific subfolders, and one photographs folder. The main data folder includes file-level metadata (flmd), data dictionary (dd), installation methods, field metadata, handheld sensor data, field data collection protocols, international generic sample number (IGSN) mapping file, and a readme file. Each sensor subfolder (BarotrollAtm and MantaRiverData) contains a subfolder containing sensor timeseries data and plots. The BarotrollAtm Data subfolder contains In Situ Rugged BaroTROLL sensor pressure and air temperature data. The MantaRiverData subfolder contains Eureka Manta+ 35B multisonde temperature, specific conductance, and turbidity. The FieldPhotos folder contains environmental context photographs and videos. All files are .csv, .pdf, .R, .jpg, .jpeg, .heic, .mov, or .mp4.

54 ENVIRONMENTAL SCIENCES↗

G-LiHT Campaign Leaf Sample details & photos, March 2017: Puerto Rico

This data package includes details of leaves sampled for leaf spectra and chemistry from 5 sites in Puerto Rico, in March of 2017. Sunlit canopy and shaded leaves of 66 species were collected. Data for each sample includes species, leaf age, type of analysis (spectroscopy, gas exchange, chemistry), sample number and sample photographs. The data package includes a spreadsheet with sample information and a zip file of photographs (1.6 GB). This data was collected as part of the 2017 BNL–G-LiHT leaf spectra campaign. See related datasets for leaf spectral reflectance and transmittance, leaf mass area (LMA), and leaf chemistry. Note that leaf sample details are also included in related datasets.

54 ENVIRONMENTAL SCIENCES↗

Leaf-to-canopy spectral reflectance, February 2018, PA-SLZ: Panama

Canopy reflectance spectra of 37 trees were measured at the Smithsonian Tropical Research Institute (STRI) San Lorenzo Protected Area site (PA-SLZ), utilising the canopy access crane to access fully sunlit leaves. Data were recorded in the middle of the day, with 20–50 measurements for each tree. The canopy structure for each crown was captured using a digital camera. Leaf-level reflectance and leaf demographic composition (age class) was recorded in detail for a > 0.5 meter branch sampled from each canopy tree (corresponding to the position where canopy spectra were measured). This dataset includes processed canopy and leaf-level spectral measurements (*.xlsx), raw spectral data (Spectral Evolution PSR+, *.raw, *.sed), sample details (*.xlsx) and *.pdf summaries containing low resolution photographs of the measured canopies. Full resolution images are available in the related dataset, "Leaf-to-canopy spectral reflectance photographs, February 2018, PA-SLZ: Panama".

54 ENVIRONMENTAL SCIENCES↗

RESULTS OF THE EXAMINATION OF ELECTROCHEMICAL NOISE PROBE SPECIMENS REMOVED FROM TANK 241-AN-107 JUNE 2010

An Integrated Multi-function Corrosion Probe (IMCP) was installed in Tank 241-AN-107 on September 20, 2006. A portion of the probe was retrieved on June 8, 2010 and the sections holding the detectors were delivered to the 222-S Laboratory for analysis. The examination and disassembly of the probe sections encountered a number of challenges. However, disassembly and relevant analyses were successfully completed. The following summarizes our observations. Brittle failure of the fiberglass probe in the middle of detector 2 resulted in the recovery of only three vapor space C-rings and six supernatant bullet specimens. The design of the bullets and how they were attached to the probe made the recovery of the components more difficult. The use of glue/epoxy on the bullets and the attachment of the flat bottom of the bullets to the curved surface of the fiberglass probe body meant that weight loss on cleaning and surface area of the specimens could not be determined with acceptable accuracy. Macrophotography of all specimens reveals that corrosion was slight in the vapor space and extremely slight in the supernatant. The one pre-cracked C-ring recovered from the vapor space still had the stress bulge visible on the polished surface, indicating that crack propagation had not occurred in the tank. No photographs were taken of the C-ring before deployment. No further analysis was conducted on this specimen. A detailed discussion and photographic documentation are provided in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solids Accumulation Scouting Studies

The objective of Solids Accumulation activities was to perform scaled testing to understand the behavior of remaining solids in a Double Shell Tank (DST), specifically AW-105, at Hanford during multiple fill, mix, and transfer operations. It is important to know if fissionable materials can concentrate when waste is transferred from staging tanks prior to feeding waste treatment plants. Specifically, there is a concern that large, dense particles containing plutonium could accumulate in poorly mixed regions of a blend tank heel for tanks that employ mixing jet pumps. At the request of the DOE Hanford Tank Operations Contractor, Washington River Protection Solutions, the Engineering Development Laboratory of the Savannah River National Laboratory performed a scouting study in a 1/22-scale model of a waste staging tank to investigate this concern and to develop measurement techniques that could be applied in a more extensive study at a larger scale. Simulated waste tank solids: Gibbsite, Zirconia, Sand, and Stainless Steel, with stainless steel particles representing the heavier particles, e.g., plutonium, and supernatant were charged to the test tank and rotating liquid jets were used to mix most of the solids while the simulant was pumped out. Subsequently, the volume and shape of the mounds of residual solids and the spatial concentration profiles for the surrogate for heavier particles were measured. Several techniques were developed and equipment designed to accomplish the measurements needed and they included: 1. Magnetic particle separator to remove simulant stainless steel solids. A device was designed and built to capture these solids, which represent the heavier solids during a waste transfer from a staging tank. 2. Photographic equipment to determine the volume of the solids mounds. The mounds were photographed as they were exposed at different tank waste levels to develop a composite of topographical areas. 3. Laser rangefinders to determine the volume of the solids mounds. The mounds were scanned after tank supernatant was removed. 4. Core sampler to determine the stainless steel solids distribution within the solids mounds. This sampler was designed and built to remove small sections of the mounds to evaluate concentrations of the stainless steel solids at different special locations. 5. Computer driven positioner that placed the laser rangefinders and the core sampler in appropriate locations over solids mounds that accumulated on the bottom of a scaled staging tank where mixing is poor. These devices and techniques were effective to estimate the movement, location, and concentrations of the solids representing heavier particles and could perform well at a larger scale The experiment contained two campaigns with each comprised of ten cycles to fill and empty the scaled staging tank. The tank was filled without mixing, but emptied, while mixing, in seven batches; the first six were of equal volumes of 13.1 gallons each to represent the planned fullscale batches of 145,000 gallons, and the last, partial, batch of 6.9 gallons represented a full-scale partial batch of 76,000 gallons that will leave a 72-inch heel in the staging tank for the next cycle. The sole difference between the two campaigns was the energy to mix the scaled staging tank, i.e., the nozzle velocity and jet rotational speed of the two jet pumps. Campaign 1 used 22.9 ft/s, at 1.54 rpm based on past testing and Campaign 2 used 23.9 ft/s at 1.75 rpm, based on visual observation of minimum velocity that allowed fast settling solids, i.e., sand and stainless steel, to accumulate on the scaled tank bottom.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opening the Plutonium-Beryllium Neutron Sealed-Source RGMA1002-113

The radiograph of the PuBe neutron sealed-source was useful in determining dimensions and identifying construction details. This information gives the engineer and machinist a better idea of where to breach the outer container. It would be advantageous to use a higher energy radiography system to provide information about inner container dimensions, construction details, and nuclear material location to facilitate disassembly. Characterization of the inner and outer container materials would be useful for selecting proper cutting inserts to provide more efficient and cleaner cuts. A real-time, in-line method for qualitatively identifying metal compositions such as handheld x-ray fluorescent (XRF) may prove sufficient. The disassembly of PuBe sealed-sources generally involves numerous attempts to pry a lid or plug from the innermost container. The forces involved make it impractical to hold the source so this attempt must take place with the container held horizontally in the collet. The horizontal orientation risks the flow of PuBe materials out of the container when the plug is freed as occurred in this disassembly. To mitigate this risk, it was agreed that a small vise should be introduced into the glovebox to hold the container firmly in a vertical orientation for attempts to pry off lids or plugs. The vise should hold cylindrical containers firmly without inflicting scratches or gouges into sealed-source metal surfaces. Documentation of PuBe neutron sealed-source disassembly is effectively recorded with a series of professional photographs as presented in this report. Unfortunately, the prevalence of metal surfaces and materials combined with uneven, low light conditions reduce the contrast between disassembled parts and background. To improve the photographic record of disassembly, colored liner materials should be identified and introduced as a staged background for PuBe component pictures.

07 ISOTOPE AND RADIATION SOURCES↗