Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic films EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the prescribed dose after two parallel opposed irradiation fields. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Diffractive-refractive optics: X-ray collimator

Diffractive-refractive optics are x-ray focusing monochromators based on the diffraction on profiled crystal surface. Diffraction on longitudinal parabolic groove machined in crystal surface forms a sagittaly focused synchrotron radiation beam. Such kind of monochromator may be realized as a crystal with parabolic hole, where the beam is diffracted on the inner wall of the hole. Two such asymmetrically cut crystals set into antiparallel position, creating a dispersive (+,-,-,+) arrangement, form a sagittaly focusing x-ray monochromator which should be practically aberration-free. The focusing properties of such kind of monochromator are discussed in detail and it is shown for the first time that it can be used not only for focusing but also for creating highly parallel monochromatic beam in the broad region of the Bragg angles. This device with parabolic hole has not been tested experimentally yet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple dielectric barrier discharge device for generating slot homogeneous plasma in atmospheric pressure air

We report a simple dielectric barrier discharge device for generating slot homogeneous plasma in atmospheric pressure air. It consists of two parallel water electrodes with a distance adjusting micrometer. With increasing the applied voltage, the discharge becomes homogeneous. The electron temperature, vibrational temperature (T{sub V}) of N{sub 2}, and rotational temperature (T{sub R}) of N{sub 2}{sup +} are estimated by optical emission spectroscopy. Both T{sub V} and T{sub R} remain unchanged along the slot in the homogeneous discharge regime. The trend of the T{sub V} with respect to the applied voltage is opposite from that of T{sub R}, while the electron temperature keeps constant with the increasing applied voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

High-Fidelity Velocity and Concentration Measurements of Turbulent Buoyant Jets

Accurate models of turbulent buoyant flows are essential for the design of the cooling circuit of nuclear reactors and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We analyze experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous particle image velocimetry and laser-induced fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The refractive index matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy-driven flows (e.g. natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in a uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as a basis for the development of a new model that captures turbulent mixing.

laser induced fluorescence↗

THE ROLE OF QUENCHING TIME IN THE EVOLUTION OF THE MASS–SIZE RELATION OF PASSIVE GALAXIES FROM THE WISP SURVEY

We analyze how passive galaxies at z ∼ 1.5 populate the mass–size plane as a function of their stellar age, to understand if the observed size growth with time can be explained with the appearance of larger quenched galaxies at lower redshift. We use a sample of 32 passive galaxies extracted from the Wide Field Camera 3 Infrared Spectroscopic Parallel (WISP) survey with spectroscopic redshift 1.3 ≲ z ≲ 2.05, specific star formation rates lower than 0.01 Gyr{sup −1}, and stellar masses above 4.5 × 10{sup 10} M {sub ⊙}. All galaxies have spectrally determined stellar ages from fitting of their rest-frame optical spectra and photometry with stellar population models. When dividing our sample into young (age ≤2.1 Gyr) and old (age >2.1 Gyr) galaxies we do not find a significant trend in the distributions of the difference between the observed radius and that predicted by the mass–size relation. This result indicates that the relation between the galaxy age and its distance from the mass–size relation, if it exists, is rather shallow, with a slope α ≳ −0.6. At face value, this finding suggests that multiple dry and/or wet minor mergers, rather than the appearance of newly quenched galaxies, are mainly responsible for the observed time evolution of the mass–size relation in passive galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Wavelength-Division Multiplexing With Integrated Optics

High-density wavelength-division-multiplexed optoelectronic integrated circuits developed for use as transceivers in fiber-optic communications between computers, according to proposal. One of proposed multiplexer/demultiplexer units provides simultaneous communication on 32 wavelength channels at overall data rate greater than 40 Gb/s, increasing channel capacity, simplifying transmitting and receiving electronics and reducing delay by eliminating serial-to-parallel and parallel-to-serial "bottlenecks."

Lang, Robert J.↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

A method for eliminating Faraday rotation in cryostat windows in longitudinal magneto-optical Kerr effect measurements

A solution to the problem of disturbing effect of the background Faraday rotation in the cryostat windows on longitudinal magneto-optical Kerr effect (LMOKE) measured under vacuum conditions and/or at low temperatures is proposed. The method for eliminating the influence of Faraday rotation in cryostat windows is based on special arrangement of additional mirrors placed on sample holder. In this arrangement, the orientation of the cryostat window is perpendicular to the light beam direction and parallel to an external magnetic field generated by the H-frame electromagnet. The operation of the LMOKE magnetometer with the special sample holder based on polarization modulation technique with a photo-elastic modulator is theoretically analyzed with the use of Jones matrices, and formulas for evaluating of the actual Kerr rotation and ellipticity of the sample are derived. The feasibility of the method and good performance of the magnetometer is experimentally demonstrated for the LMOKE effect measured in Fe/Au multilayer structures. The influence of imperfect alignment of the magnetometer setup on the Kerr angles, as derived theoretically through the analytic model and verified experimentally, is examined and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning the dielectric properties of thiourea analog crystals for efficient nonlinear optical applications

Materials with low dielectric constant have attracted a great deal of interest in the field of nonlinear applications and microelectronic industry. Metal complexes of thiourea with group II transition metals (Zn, Cd) as central atom and period III elements (S, Cl) were synthesized by chemical reaction method and single crystals were grown from aqueous solution by slow evaporation method. By parallel plate capacitor technique, the dielectric response, dissipation factor, ac conductivity and impedance of virgin and metal complexes have been studied in the frequency (100 Hz to 5 MHz) and temperature (303-423 K) ranges. Metal complexes of thiourea with cadmium substitute have a low dielectric constant less than 10. Also the presence of chlorine in the metal complex induces noncentro symmetric structure. Hence the role of group II transition metals and period III elements in tuning the dielectric properties for efficient nonlinear applications has been studied.

36 MATERIALS SCIENCE↗

Thickness dependence of piezo-bimorph adaptive mirror bending

A new generation of adaptive x-ray optics (AXO) is being installed on high-coherent-flux x-ray beamlines worldwide to correct and control the optical wavefront with sub-nm precision. These ultra-smooth mirrors achieve high reflectivities at glancing angles of incidence and can be hundreds of mm long. One type of adaptive x-ray mirror relies on piezoelectric ceramic strips which are segmented into channels and actuated to induce local, longitudinal bending, generating one-dimensional shape changes in the mirror substrate. A recently described mirror model uses a three-layer geometry with parallel actuators on the front and back surfaces of a thicker mirror substrate. By analogy to a solved problem in the thermal actuation of a tri-metal strip, we show that the achievable bending radius varies approximately as the square of the substrate thickness. We provide an analytic solution and simulate bending using a finite-element model.

47 OTHER INSTRUMENTATION↗

Self-action of Bessel wave packets in a system of coupled light guides and formation of light bullets

The self-action of two-dimensional and three-dimensional Bessel wave packets in a system of coupled light guides is considered using the discrete nonlinear Schrödinger equation. The features of the self-action of such wave fields are related to their initial strong spatial inhomogeneity. The numerical simulation shows that for the field amplitude exceeding a critical value, the development of an instability typical of a medium with the cubic nonlinearity is observed. Various regimes are studied: the self-channeling of a wave beam in one light guide at powers not strongly exceeding a critical value, the formation of the “kaleidoscopic” picture of a wave packet during the propagation of higher-power radiation along a stratified medium, the formation of light bullets during competition between self-focusing and modulation instabilities in the case of three-dimensional wave packets, etc. In the problem of laser pulse shortening, the situation is considered when the wave-field stratification in the transverse direction dominates. This process is accompanied by the self-compression of laser pulses in well enough separated light guides. The efficiency of conversion of the initial Bessel field distribution to two flying parallel light bullets is about 50%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Origins Space Telescope Integration and Testing

This paper describes the plans, flows, key facilities, test beds, pathfinders, simulators and ground support equipment that could be used to fully integrate, functionally test and qualify the Origins Space Telescope (Origins). The Origins Observatory consists of the Spacecraft Bus Module (SBM) and the Cryogenic Payload Module (CPM), which comprises the telescope and three science instruments. The telescope is a Three Mirror Anastigmat (TMA) and is composed of four mirrors: three with optical power (the elliptical primary, hyperbolic secondary, and elliptical tertiary mirrors) and a flat field-steering mirror (FSM). The three science instruments spanning the wavelength range 2.8 to 588 μm provide the powerful new spectroscopic and imaging capabilities required to achieve the scientific objectives. The Origins Survey Spectrometer (OSS) uses six gratings in parallel to take multi-beam spectra simultaneously across the 25 to 588 μm window through long slits enabling deep 3D extra-galactic surveys. The Far-IR Imager/Polarimeter (FIP) provides imaging and polarimetric measurement capabilities at 50 and 250 μm. Its fast mapping enables rapid follow-up of transient or variable sources and efficient monitoring campaigns. The Mid-Infrared Spectrometer (MISC-T) provides spectroscopy simultaneously over 2.8 to 20 μm with exquisite stability and precision (<5 ppm between 2.8 to 10 μm, <20 ppm between 11 to 20 μm). All the instruments are delivered for Integration and Test fully qualified and calibrated. The Integration and Test program implemented at each level of assembly is discussed as well as the separation of thermal vacuum testing between the hot and cold zones of the Observatory. Portions of this manuscript appear in the Origins Study Final Report.

Origins↗

Eye-Safe KGd(WO{sub 4}){sub 2} Raman Lasers: Comparative Study of Pumping of Nd:KGd(WO{sub 4}){sub 2} Lasers With {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} Working Transitions{sup **}

This is a comparative study of eye-safe extracavity KGd(WO{sub 4}){sub 2} (KGW) Raman lasers that convert multimode emission from pulsed Nd:KGW lasers operating on the {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} transitions into the third Stokes component at λ = 1500 nm and the first Stokes component at λ = 1507 or 1538 nm. For equal sizes of the Raman and laser sections of a Raman laser emitting the third Stokes component, the pulse energy is higher (~14.2 mJ) and the divergence of the Stokes beam is lower (~9.4 mrad) for a lower energy of the Nd:KGW laser (~6.7 J). For pump pulse energies of 29–34 mJ, all the Raman lasers have essentially the same optical lasing efficiency of up to 36%. In terms of the electrical energy delivered to the flashlamp, however, the overall efficiency of the Raman laser for the third Stokes component is a factor of ~1.7 higher. The duration of the Raman pulses is comparable to that of the pump pulses and is ~20 ns for the first Stokes components. The pulse in the third Stokes component is shorter by a factor of 2.5–3. Given the different pump levels and the differences in the thermallyinduced optical distortions of the Nd:KGW laser components, the energy density distribution for beams of the first Stokes components is elliptical, while that of the third Stokes components is almost circular. The possibility of simultaneous lasing at wavelengths of 1507 and 1538 nm with parallel and mutually orthogonal polarizations of the Stokes waves is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Breakdown and Discharge Characteristics of High Repetition Frequency Nanosecond Pulsed Air Dielectric Barrier Discharge

This study explores the breakdown characteristics and discharge modes in a parallel plate air dielectric barrier discharge system using repetitive nanosecond pulses, with pulse repetition frequencies (PRFs) from 0.1 to 100 kHz. It examines how pulse parameters—PRF, pulse number and gas pressure—affect the memory effect, leveraging current and voltage measurements, fast imaging and optical emission spectroscopy. The findings show that higher PRFs lead to a reduction in breakdown voltage well below the streamer breakdown threshold. We argue that this effect may be attributed to the cumulative buildup of metastable species and negative ions in the discharge gap which could sustain free electrons in‐between the voltage pulses. Despite observing increased energy deposition with higher PRFs, the impact on filament formation was minimal, highlighting a strong dependence of discharge morphology on the accumulation of plasma‐produced species. This research studies provides valuable insights for controlling discharge regimes in applications such as plasma‐assisted combustion, surface treatment and air treatment by clarifying the interactions between discharge mechanisms at different PRFs and pressures.

42 ENGINEERING↗

Influence of convection on free growth of dendrite crystals from solution

The free growth of dendrites in a uniformly supercooled solution was examined using cine photography with a Schlieren optical system. Crystals were grown in the bulk of the solution from a centrally located capillary tube, nucleated at the interface with a liquid nitrogen cooled wire. Crystals propagated along the tube, the slower growing orientations eliminated, and emerged at the tip, usually growing parallel to the tube direction. For both sodium sulfate decahydrate from its solution and ice from sodium chloride solution, growth rate and fineness of dendrites increased with supercooling. In sodium sulfate, upward convection of the less dense depleted solution occurs; downward convection was observed for the rejected, more concentrated sodium chloride solution. In both cases, there was a spatial and temporal delay in the release of the convective plume from the moving dendrite tip. The role of this convection on the growth characteristics and the production of secondary crystals is examined. A proposed low-g experiment to examine differences in growth rate, crystal texture, and secondary nucleation in a reduced convective regime where molecular diffusion is the dominant transfer process is discussed.

Hallett, J.↗

Wavelength division multiplexed fiber optic absolute position encoder

A wavelength division multiplexing (WDM) method for fiber optic sensors is proposed which uses a broadband light source and narrow bandpass thin film optical filter coatings on cylindrical graded index lenses. In the WDM system described here, all bits are multiplexed onto a single signal return fiber by assigning each bit a unique wavelength. A multielement photodetector array is used as the encoded position information is in parallel. Preliminary prototype test results are presented.

Park, Eric D.↗

Gas-rich dwarf galaxies in dense and sparse environments

Dwarf irregular galaxies (generically labelled Im for the present purposes) pose an enigma to students of galaxy evolution. In nearby groups and the Virgo cluster, Im galaxies are at least as abundant as spiral galaxies, and their low surface brightnesses and high gas-to-stars ratios suggest that (at least in the stochastic self-propagating star formation scenario) there should be significant numbers of HI clouds with masses approaching 10(exp 8) solar mass which have undergone very little or no star formation. To date, however, no clouds with so little star formation that they would not be recognized as Im galaxies on high-quality photographic plates have been identified. There have been suggestions that such dwarfs may be tidally disrupted in regions of high galactic density, but may be prevalent in low density regions. We offer data from three parallel programs relevant to this issue. (1) A large number of Im galaxies throughout the Local Supercluster have been mapped in the HI spectral line using the Arecibo Radiotelescope, and we can establish the frequency with which HI disks much more extended than their optically visible portions are found. (2) Our extensive mapping of spiral and dwarf galaxies in the Virgo cluster allows us to set stringent limits on the density of star-free Hi clouds in that cluster. (3) We have conducted a sampling of the void in the distribution of galaxies toward the super galactic pole, optimized for finding low-mass HI clouds at redshifts out to approximately 2000 km/s.

Hoffman, G. Lyle↗