Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LDMS New Features for Deployment in Advanced Environments and Feedback for Operations

We describe how LDMS is being used to collect application data concurrent with system data and how the low-latency availability of this data for analysis can be used for real-time data analysis and feedback in order to support efficient, resilient, and reliable system operations. Finally, we will describe current related research areas.

Brandt, James Michael [Sandia National Laboratorie↗

Bio-inspired multiscale design for perovskite solar cells

Metal halide perovskite semiconductors have attractive light-harvesting and charge-carrier transport properties for photovoltaics. Perovskite solar cells (PSCs) and modules have demonstrated their commercial promise with high power conversion efficiencies, but still face stability challenges. In this Review, we explore how biomaterials offer design inspiration for the development of durable and efficient PSCs at three different scales. At the molecular level, bio-inspired molecular interactions are harnessed towards crystallization control and degradation prevention, which offers an enhancement in long-term maximum-power-point tracking stability. At the microstructural level, self-healing and strength-enhancing strategies, utilizing dynamic bonds and interfacial reinforcement, can help PSCs to recover from physical damage and maintain high performance. At the device level, macroscopic functionalities, such as moth-eye-inspired structures tailored to different layers, can collectively enable antireflection, radiative cooling and self-cleaning to optimize light management, heat dissipation and encapsulation in PSCs. Bio-inspired PSC research can combine improved efficiency and lifetime, with abundant, biocompatible alternatives to conventional stabilizers. Future efforts should focus on screening bioinspired molecules to optimize film crystallization and stability, developing self-healing mechanisms triggered by operational stress, designing cost-efficient biomicrostructures, and integrating multifunctional encapsulation to enhance the efficiency and lifespan of PSCs.

Duan, Tianwei↗

Integrating Safety, Security, and Nuclear Operations for Advanced Reactors

The traditional separation between safety, security, and operations teams has created significant barriers to achieving optimal outcomes. When security considerations are introduced late in the design process, they often conflict with already-established architectural, operational, or engineering parameters. Retrofitting security measures can lead to increased costs, schedule delays, and compromises in security effectiveness. For instance, the need to retrofit physical barriers or surveillance systems often results in trade-offs that could have been avoided with earlier input from security professionals. Delayed integration can also affect regulatory processes and result in licensing delays. Security reviews conducted at later stages frequently identify gaps that necessitate significant redesign efforts, impacting not only scope, schedule, and budget, but also adding risk and lowering stakeholder confidence in the project. This paper aims to address these challenges by identifying practical opportunities for integrating security considerations seamlessly with design and operations teams throughout the entire lifecycle of nuclear facilities—from conceptual design to commissioning and beyond. The research emphasizes the value of early and continuous collaboration among stakeholders to ensure that security measures are robust, operationally effective, and cost-efficient. By examining case studies, analyzing past incidents, and leveraging best practices from other high-security industries, this study highlights actionable strategies for bridging the gap between safety, security, and operations teams.

Zineddin, Dr. Z. [ORNL] (ORCID:0009000848740725)↗

Tethered Small-Molecule Acceptors Simultaneously Enhance the Efficiency and Stability of Polymer Solar Cells

For polymer solar cells (PSCs), the mixture of polymer donors and small-molecule acceptors (SMAs) is fine-tuned to realize a favorable kinetically trapped morphology and thus a commercially viable device efficiency. However, the thermodynamic relaxation of the mixed domains within the blend raises concerns related to the long-term operational stability of the devices, especially in the record-holding Y-series SMAs. Here, a new class of dimeric Y6-based SMAs tethered with differential flexible spacers is reported to regulate their aggregation and relaxation behavior. In their polymer blends with PM6, it is found that they favor an improved structural order relative to that of Y6 counterpart. Most importantly, the tethered SMAs show large glass transition temperatures to suppress the thermodynamic relaxation in mixed domains. For the high-performing dimeric blend, an unprecedented open circuit voltage of 0.87 V is realized with a conversion efficiency of 17.85%, while those of regular Y6-base devices only reach 0.84 V and 16.93%, respectively. Most importantly, the dimer-based device possesses substantially reduced burn-in efficiency loss, retaining more than 80% of the initial efficiency after operating at the maximum power point under continuous illumination for 700 h. In conclusion, the tethering approach provides a new direction to develop PSCs with high efficiency and excellent operating stability.

14 SOLAR ENERGY↗

Contaminant Source Identification from Finite Sensor Data: Perron–Frobenius Operator and Bayesian Inference

Sensors in the built environment ensure safety and comfort by tracking contaminants in the occupied space. In the event of contaminant release, it is important to use the limited sensor data to rapidly and accurately identify the release location of the contaminant. Identification of the release location will enable subsequent remediation as well as evacuation decision-making. In previous work, we used an operator theoretic approach—based on the Perron–Frobenius (PF) operator—to estimate the contaminant concentration distribution in the domain given a finite amount of streaming sensor data. In the current work, the approach is extended to identify the most probable contaminant release location. The release location identification is framed as a Bayesian inference problem. The Bayesian inference approach requires considering multiple release location scenarios, which is done efficiently using the discrete PF operator. The discrete PF operator provides a fast, effective and accurate model for contaminant transport modeling. The utility of our PF-based Bayesian inference methodology is illustrated using single-point release scenarios in both two and three-dimensional cases. The method provides a fast, accurate, and efficient framework for real-time identification of contaminant source location.

42 ENGINEERING↗

Turboexpander for Direct Cooling in Hydrogen Vehicle Fueling Infrastructure

Hydrogen fuel cell electric vehicles (FCEVs) have been identified as one of a few options for zero carbon emissions transportation. A major advantage of FCEVs is that they can fuel quickly and follow a familiar fueling behavior to hydrocarbon-fueled vehicles. Whether light duty or heavy duty, the goal for a hydrogen dispenser is to fuel a vehicle in the same amount of time as the fossil fuel equivalent. When hydrogen is dispensed into the vehicle storage system, however, the temperature rises due to the Joule-Thomson effect and the heat of compression. Typically, vehicles store the compressed hydrogen in composite overwrapped pressure vessels that have a polymer liner with an operational temperature limit of 85°C. This temperature limit can be exceeded during fast fueling if hydrogen is not precooled. Precooling allows for a dispenser to fuel a vehicle at a faster flow rate by preventing the storage tank on the vehicle from overheating. Fueling protocols and requirements are presented in SAE J2601 Fueling Protocols for Light Duty Gaseous Hydrogen Surface Vehicles [1]. A heavy-duty equivalent is under development with similar requirements for precooling. Currently, conventional precooling for light-duty vehicle refueling uses a heat exchanger and chiller to cool the hydrogen gas to -40°C before entering the vehicle. The precooling system represents a significant part of the station capital and operating costs, so if the cost of the precooling system can be reduced by improving its efficiency, the overall station capital and operating cost can be reduced. In this project, National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) researchers teamed up to investigate the turboexpander precooling application. A turboexpander is a device that places a turbine in a flow path where a pressure differential can be attained. This expansion device will extract work and lower the temperature of the fluid as the pressure reduces. While initial calculations based on established principles showed potential for a turboexpander to generate cooled gas, much work needs to be done to prove the concept. Turboexpanders typically work best under steady state conditions, while the dispenser is a very dynamic flow system. Dynamic turboexpander systems have been proven, such as a turbocharger on a gasoline vehicle. The inlet pressure at a dispenser is also much higher than any other known turboexpander system but should behave similarly to higher density fluids at lower pressures. Having both performed initial calculations, NREL and SNL researchers teamed up to investigate the turboexpander precooling application further. A project was soon built around the idea with SNL performing system modeling using previously proven capabilities and NREL performing hardware characterization with established station capabilities. Creare LLC was contracted as the turbomachinery expert to design and build the concept device. Part way through the project, however, contracting issues with the funding partner caused the project to terminate early before building and characterizing the concept device. While the project could not continue, many key findings were already learned. This paper is a summary of those findings.

08 HYDROGEN↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

As an alternative to a steam cycle, a supercritical carbon dioxide (sCO2) power cycle can be considered. Able et. al performed an analysis of an sCO2 cycle in a 2x2-1 configuration; however, this study did not include carbon capture. Previous studies assumed an H-Frame turbine and added a solvent based 95% carbon capture system and performed a levelized cost of electricity (LCOE) optimization for the plant. Their results suggest a LCOE slightly better than when using a steam cycle. In the study, steam is still generated in the heat recovery sections for the solvent regeneration in the carbon capture stripper reboiler. H-Frame gas turbines are also assumed. This work starts with the optimal design from the mentioned work to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. H-Frame gas turbine off-design performance and exhaust conditions to the heat recovery section are obtained from commercial software, Thermoflow®. The CO2 turbomachinery, heat exchangers and other unit operations are sized and implemented in an Aspen Plus® model. Using the gas turbine exhaust conditions as input, the sCO2 cycle is optimized by adjusting stream split ratios, sCO2 circulation flowrate and compressor speed for maximum efficiency. This is done while keeping the target 95% CO2 capture.

Chinen, Anderson Soares↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A DATA EFFICIENT SPARSE MODELING FRAMEWORK FOR POWER ESTIMATION IN WATER TREATMENT SENSING OPERATIONS

With increasing freshwater scarcity, advanced process design mechanisms such as Closed-Circuit Reverse Osmosis (CCRO) and Digital/Physical Twin systems are gaining traction in water treatment and reuse operations. While digital and physical twin models enable improved system insight and control, their development is often expensive and computationally intensive, requiring large volumes of synthetic or experimental data to characterize underlying process dynamics. This work introduces a sparse surrogate modeling framework to estimate power consumption from measured flow and pressure variables, along with their nonlinear polynomial and interaction expansions. To ensure model reliability and reduce overfitting, a two-stage pipeline is proposed. First, a dynamic data filtering algorithm is employed to remove uninformative observations and transient operational states. Second, a sparse penalized regression technique is applied to select a minimal set of parsimonious features. The proposed model achieves high sparsity, retaining only 7 out of 34 candidate features (≈79.41% sparsity) while delivering a root mean square error (RMSE) of 0.072 on the test dataset.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

High-Mileage Courier Fleet Vehicle On-Road Logger Data

This dataset describes the performance and fuel efficiency of AVTA test vehicles operating in commercial courier fleets the Phoenix, AZ metro area between 2010 and 2016. Aftermarket data loggers were installed in two to four vehicles of each of 30+ distinct year/make/models (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Loggers recorded vehicle operation as they were driven up to 160,000 miles in up to three years of fleet testing. Parameters were logged at 1-second intervals, including - vehicle speed, - engine and/or electric motor speed, - fuel and/or electricity consumption, and - ambient temperature. This dataset includes both raw second-by-second data and trip-level metrics. This dataset is shared by API; a small sample of the vehicle and logger data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of in-use engine speed/torque heat maps across multiple heavy-duty commercial vehicle vocations

The U.S. Department of Energy (DOE) established the SuperTruck program with the goal of achieving brake thermal efficiency (BTE) greater than or equal to 55% as demonstrated in an operational heavy-duty (HD) diesel engine at a 65-miles-per-hour (mph) cruise point. Beyond the line-haul application, HD engines operate in a wide range of speed and torque conditions that are unlikely to yield the same efficiency under real-world operation. Thereby, the in-use engine heat maps described in this paper are a valuable tool to illustrate whether the engine-efficiency “sweet spot” matches the most frequent operating conditions. In this study, NREL developed engine heat maps to quantify the important operating points for various vocations using our Fleet DNA database of commercial fleet vehicle operations data. These heat maps clearly show that high-frequency operating points vary significantly according to vehicle vocation, while only a few of them match the sweet spot. Beyond the illustration, engine in-use heat maps can also be leveraged to build up reduced-order engine-efficiency models, needed by many rapid powertrain simulations. As case studies, nine reduced-order models – including line-haul truck, transfer truck, transit bus, transit bus with compressed natural gas (CNG) engine, drayage, refuse pickup, local delivery, utility truck, and school bus with CNG engine – using a trust-region reflective algorithm to fit the on-road data extracted based on the engine in-use heat maps.

33 ADVANCED PROPULSION SYSTEMS↗

Python-EPICS RF Conditioning Automatic Control System at the Spallation Neutron Source

The RF Test Facility (RFTF) at the Spallation Neutron Source (SNS) is used for the conditioning of RF compo-nents such as ceramic vacuum windows and power cou-plers prior to their installation in the H- ion linear accel-erator. This process exposes components to high-power RF fields and thermal cycling to improve performance and remove surface impurities. To automate and optimize this process, a Python-based EPICS control system was developed alongside targeted hardware upgrades. The system enables real-time monitoring and control of RF power levels, temperature, and vacuum pressure. A user-friendly graphical interface was implemented using CS-Studio (Phoebus), allowing operators to adjust parameters and collect data efficiently. The system integrates a High-Power Protection Module (HPM) for interlocks based on vacuum and arc detection, ensuring safe operation. These upgrades have significantly improved the efficiency, accuracy, and safety of RF conditioning at the SNS RFTF. This paper describes the updated RF conditioning sys-tem, highlighting the software and hardware develop-ments and their application in support of the Proton Pow-er Upgrade (PPU) project.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Complete Evaluation of ION Cost Reduction Opportunities for LWRS Pathways

The Light Water Reactor Sustainability (LWRS) Program, sponsored by the U.S. Department of Energy (DOE), plays a pivotal role in enhancing the sustainability, safety, and economic viability of the nation's fleet of nuclear power plants. This program collaborates extensively with industry, vendors, suppliers, regulatory agencies, and research and development organizations within the nuclear energy sector. The overarching goals of the LWRS program are twofold: to provide innovative science and technology-based solutions to the nuclear industry, surpassing current performance models, and to manage the aging of systems, structures, and components (SSCs) to extend the operational lifetimes of nuclear power plants safely, efficiently, and economically. The program focuses on five research and development pathways: Plant Modernization: This pathway seeks to enhance the economic viability of nuclear power plants in evolving energy markets through innovation, efficiency improvements, and digital transformation. The integration of digital technologies into plant operations is a central theme, aiming to create a seamless digital environment that improves plant economics and safety. Flexible Plant Operation and Generation: Research efforts in this pathway explore opportunities for light-water reactors (LWRs) to directly supply energy to industrial processes, diversifying revenue generation approaches and improving economic sustainability.

42 ENGINEERING↗

Impact of FERC Order 2222 on DER Participation Rules in US Electricity Markets

Electricity markets in the bulk grid are beginning to implement market mechanisms that support the procurement of flexible capabilities from wide range of technologies, including distributed energy resources (DERs). The flexibility of these resources will help counterbalance supply uncertainties from large-scale integration of variable renewable generation. To encourage development of distributed and aggregated market participants, FERC Order 2222 was issued in September 2020 to require each Independent System Operator (ISO) in the US to implement rules that enable broader participation from aggregations of DERs in the bulk market. The following paper first describes the generic design of ISO markets before introducing the new market participation rules that ISOs have proposed for compliance with Order 2222. The paper then describes how software performance issues may continue to affect the eligibility requirements and offer structures for DER aggregations participating in ISOs, noting that continued research on computational methods may help reduce burdens for DER integration. The prospects for transmission and distribution system coordination is second major issue discussed, which will require minor changes to existing processes in the short term. In the longer term, there is more opportunity for more wide-ranging reforms, such as the development of a Distribution System Operator (DSO) framework. Newly proposed market rules may affect how Transactive Energy Systems (TES) will help facilitate efficient formation of DER aggregations and operation of the individual DERs within an aggregation. Within the TES context, the challenge is to fully understand how resource eligibility and operational and planning coordination methods will affect the design and implementation of TES.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

A guide to performing CO 2 electrolysis in zero-gap electrolyzers

Recent advances in the technology readiness level (TRL) of low-temperature electrochemical CO 2 reduction (eCO2R) have demonstrated that the technology has potential for industrial deployment. However, industrial deployment of eCO2R still requires advances to reach cost parity with existing thermal catalytic pathways. Technoeconomic analysis of eCO2R suggests that research and development will require a decrease in both capital expenditures and operational expenditures to be cost competitive. Here, to decrease the capital expenditures of the system will require increasing the durability to >3 years, while decreasing the operational expenditures will require an increase in energy efficiency due to the cost of electricity being the driving operational cost of a unit.

Energy↗