Systematic Operating Temperature Differences Between Al-BSF, PERC, and PERT-With-Optimized-Rear-Reflector Solar Mini-Modules Due to Rear Reflectance

Reflecting sub-bandgap light from photovoltaic modules has the potential to improve lifetime energy generation of fielded systems by reducing operating temperature. In this article, the temperature of fielded aluminum back-surface field (Al-BSF) and passivated emitter and rear contact (PERC) mini-modules was monitored every 5 minutes for 75 days along with corresponding meteorological data. Additionally, passivated emitter rear totally diffused (PERT) mini-modules with high-performance sub-bandgap rear reflectors were tested and compared to the state-of-the-art industrial modules. These reflectors consisted of a >300-nm-thick silicon dioxide nanoparticle film with a low refractive index. The impact of reflectance on measured operating temperature was isolated with a previously developed thermal model and quantified as the reflectance-induced median temperature difference between each tested module at representative outdoor conditions (1000 W m -2 , 25 degrees C ambient temperature, and 1.43 m s -1 wind speed). We found that, because of their reflectance differences, PERC modules ran systematically cooler than Al-BSF modules by 1.0 degrees C, whereas the PERT-with-optimized-rear-reflector systematically operated 1.4 degrees C cooler than the Al-BSF module and 0.4 degrees C than the PERC module. We also found that the rear reflector provided the greatest temperature benefit during periods of highest irradiance.

14 SOLAR ENERGY↗

Brief: Daily Performance Changes in Metal Halide Perovskite PV Modules

Metal halide perovskite photovoltaic modules deployed outdoors and held at their maximum power point show daily, reversible, relative changes of up to 30% in efficiency between morning and afternoon. Predicting energy yield and quantifying reliability will require properly handling such daily performance changes.

14 SOLAR ENERGY↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Verifying Deep Reductions in the Nuclear Arsenals: Development and Demonstration of a Motion-detection Subsystem for a “Buddy Tag” Using Non-export Controlled Accelerometers

Future nuclear arms-control agreements may place numerical limits on items that are difficult to monitor with national technical means, even when complemented with onsite inspections. Such items could include small objects and mobile assets, such as non-deployed nuclear warheads and mobile missile launchers. Typically, this verification task can be addressed with unique identifiers, but standard tagging techniques may be unacceptable in this case due to host concerns about safety and intrusiveness. First proposed in the late 1980s and partially developed by Sandia National Laboratories in the early 1990s, the “Proximity Tag” or “Buddy Tag” concept seeks to overcome these concerns by separating the tag from the treaty accountable item itself. A buddy tag has two key elements: a tamper-indicating enclosure and a motion-detection system designed to detect illicit movements in a stand-down period. As part of this project, we have built a buddy-tag prototype for demonstration and evaluation purposes. This paper reviews the design choices and functionalities of the tag’s motion-detection subsystem.We pursue a modular approach for the tag’s hardware, built around an Arduino-class microcontroller and a non-export-controlled low-noise accelerometer, and use open-source algorithms for the motion-detection software. Finally, we discuss the results of an extensive experimental campaign involving both indoor and outdoor measurements assessing the performance of the tag under real-world environmental conditions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling and Measurements for Mitigating Interface from Skyshine

Skyshine, the radiation scattered in the air above a high-activity gamma-ray source, can produce interference with radiation portal monitor (RPM) systems at distances up to even many hundred meters. Pacific Northwest National Laboratory (PNNL) has been engaged in a campaign of measurements, design work and modeling that explore methods of mitigating the effects of skyshine on outdoor measurements with sensitive instruments. An overview of our work with shielding of skyshine is being reported by us in another paper at this conference. This paper will concentrate on two topics: measurements and modeling with Monte Carlo transport calculations to characterize skyshine from an iridium-192 source, and testing of a prototype louver system, designed and fabricated at PNNL, as a shielding approach to limit the impact of skyshine interference on RPM systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

Model-Free Control of Indoor Temperatures in Residential Buildings: Convergence Analysis

Model-free control (MFC) has recently been applied in multiple fields, including indoor air temperature regulation in buildings. It is a data-enabled feedback tracking control strategy for complex systems using a simplified representation of the ultra-local approximation model through the unique information of input-output behavior. MFC is a prevailing control strategy for systems with unknown or poorly known system dynamic models. Thus, it is a relatively simple, but efficient, trajectory tracking controller. In this paper, we investigate the convergence rate of MFC when applied to controlling indoor temperatures in residential buildings subject to outdoor weather disturbances. Numerical results show that MFC is quite robust to external disturbances, and its rate of convergence is almost one, i.e., it converges Q-sublinearly (slower than linearly).

Wu, Tumin↗

Stochastic Optimal Scheduling of Residential Appliances with Renewable Energy Sources

This paper proposes a stochastic, multi-objective optimization model within a Model Predictive Control (MPC) framework, to determine the optimal operational schedules of residential appliances operating in the presence of renewable energy source (RES). The objective function minimizes the weighted sum of discomfort, energy cost, total and peak electricity consumption, and carbon footprint. A heuristic method is developed for combining different objective components. The proposed stochastic model utilizes Monte Carlo simulation (MCS) for representing uncertainties in electricity price, outdoor temperature, RES generation, water usage, and non-controllable loads. The proposed model is solved using a mixed integer linear programming (MILP) solver and numerical results show the validity of the model. Case studies show the benefit of using the proposed optimization model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Model Predictive Control for Demand Response in a Home Energy Management System

This paper presents a chance constrained, model predictive control (MPC) algorithm for demand response (DR) in a home energy management system (HEMS). The HEMS optimally schedules controllable appliances given user preferences such as thermal comfort and energy cost sensitivity, and available residentially-owned power sources such as photovoltaic (PV) generation and home battery systems. The proposed control architecture ensures both the DR event and indoor thermal comfort are satisfied with a high probability given the uncertainty in available PV generation and the outdoor temperature forecast. The uncertainties are incorporated into the MPC formulation using probabilistic constraints instead of computationally limiting sampling-based approaches. Simulation results for various user preferences and probabilistic model parameters show the effectiveness of the HEMS algorithm response to DR requests.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metastable Changes to the Temperature Coefficients of Thin-Film Photovoltaic Modules

Transient changes in the performance of thin-film modules with light exposure are a well-known and widely reported phenomenon. These changes are often the result of reversible metastabilities rather than irreversible changes. Here we consider how these metastable changes affect the temperature dependence of photovoltaic performance. We find that in CIGS modules exhibiting a metastable increase in performance with light exposure, the light exposure also induces an increase in the magnitude of the temperature coefficient. It is important to understand such changes when characterizing temperature coefficients and when analyzing the outdoor performance of newly installed modules.

14 SOLAR ENERGY↗

Activation Energy Determination for Photovoltaic Encapsulant Discoloration by Indoor Accelerated UV Testing

A novel methodology for determining the activation energy of photovoltaic encapsulant discoloration using an indoor accelerated ultraviolet (UV) stress test while simultaneously maintaining multiple module temperatures in a single weathering chamber is presented. The testing was performed on some fresh mini-modules with a glass/EVA/cell/EVA/backsheet construction. The short-circuit current degradation from individual cells was used to quantify transmittance losses due to discoloration. Activation energy determined using indoor accelerated UV test data and Modified Arrhenius model ranges from 26 to 44 kJ/mol (0.27 to 0.46 eV). Activation energy was also determined from the outdoor field degradation data by employing different physical models that consider the individual or combined effects of key environmental factors. The approach here is instrumental to evaluating the reliability studies on encapsulant degradation mechanisms using relatively less time and resources.

14 SOLAR ENERGY↗

Partial Shade Endurance Testing for Monolithic Photovoltaic Modules

In monolithically integrated photovoltaic (PV) modules, including CdTe, CIGS, and a-Si modules, some shadows can cause permanent damage under some operating conditions. This damage reduces efficiency and causes shunts that are visible to the eye and in luminescence imaging. Although these shadows are sometimes forbidden by product documentation, we have observed this type of damage in utility-scale PV systems. Existing standards ensure that qualified modules are safe to use after they are damaged by shadows. But no standard test exists to quantify the loss of efficiency that can result from this damage. In this work we describe new, accelerated tests to quantify the power loss that occurs due to shadows from human bodies and narrow objects, such as tools, placed nearby or directly touching modules. The tests are designed to be easy to conduct uniformly across products and laboratories. The tests can be performed outdoors and last only a few minutes. In our trials on commercial products, these tests resulted in 2%-27% permanent loss in power at standard test conditions (STC). The relative loss was several times larger when measured at lower irradiance. The tests we describe can be used to differentiate products, to direct the development of technological solutions to shadow sensitivity at the cell and module levels, and to establish the need for system-level and administrative solutions to the occurrence of shadows. Similar tests will be the basis of a new International Electrotechnical Commission (IEC) technical specification (TS) 63140.

14 SOLAR ENERGY↗

Enhanced Photovoltaic Soiling in an Urban Environment

Natural soiling, or the deposition of ambient particulate matter (PM) onto the surface of solar glass, causes losses in PV production around the world. Much work in the PV community has focused on soiling in dusty desert environments. However, PV systems in urban environments are exposed to different contaminants and thus soil differently. We present an analysis of PV soiling in such an urban environment considering the impacts of meteorological parameters. We present 1 year of results from a soiling station in an urban location in Colorado. Bare glass samples were exposed outdoors for 11 days alongside the station; results from microscopy and light transmittance measurements show how moisture and dew affect the morphology and optics of contamination on glass. The coupon results suggest that natural (rain) cleanings may not be sufficient to clean solar panels in urban environments. Ion chromatography of soiling on the reference cell surfaces suggest that dry brush cleanings may not sufficiently clean chemicals deposited on solar panel surfaces in urban environments.

14 SOLAR ENERGY↗

Understanding PV Polymer Backsheet Degradation through X-Ray Scattering

Understanding how photovoltaic (PV) module backsheet polymers age and degrade in response to environmental stresses is important for designing polymers that can maintain their structural integrity after decades of outdoor use. X-ray scattering is a powerful technique for exploring backsheet polymer structure at the angstrom- (wide-angle, WAXS) and nanometer- (small-angle, SAXS) length-scales. We present the use of SAXS and WAXS to study pristine and aged polymer backsheets. The structural insight from these techniques can be used to compare the degradation induced by accelerated testing with the degradation seen in field-aged PV materials.

14 SOLAR ENERGY↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

Diagnosis of PV Cell Passivation Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on the cell ("AR c corrosion") was previously observed in studies using hot-humid test conditions with external high voltage (HV) bias. Because AR c corrosion is not well understood, mini-modules (MiMos) were examined in a comparative experiment using PERC and PERT as well as legacy Al-BSF cells. For separate MiMos with the cell circuit electrical at +1500 V, -1500 V, or unbiased "V oc", test conditions in the comparative study included 60degrees C/60% RH for 96 h, as in IEC TS 62804-1; 70degrees C/70%RH for 200 h; and 85degrees C/85% RH for 200 h. Characterizations at each read point included: camera and electroluminescence (EL) imaging, colorimetry, and I-V curve tracing. Characterizations at the final read point included: SunsVoc; spatially mapping external quantum efficiency (EQE); high resolution: photoluminescence (PL), EL, and dark lock-in thermographic (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos (stepped HV aging) and full-sized modules (outdoor aging) from previous studies. AR c corrosion was specifically observed for the glass/encapsulant/cell side of +1500 V (HV+) stressed MiMos, where appearance, color, and reflectance were the characteristics most distinguished relative to simultaneously occurring degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to silicon oxide or hydrous silica, preferentially occurring at the edges and tips of the pyramidal textured cell surface.

aging↗

Artificial Replication of Field Soiling Losses on PV Modules

In this paper, we experimentally demonstrate an improved replication of field soiling losses using an indoor artificial soiling chamber and tests on anti-soiling coated PV modules and coupons. The primary focus is to use site-specific soil collected from module surface and replicate the natural soiling processes including dust concentration in the air, slow and gradual dust accumulation and sedimentation on the module surface during the dominant soiling season of the site of interest. The experiments were conducted on two sample sets having different anti-soiling properties. The first set contains commercial modules with two different surface properties retrieved after three years of exposure from a single PV plant in a mid-Atlantic location; the other set contain glass coupons with three different coating materials that were installed and exposed over 4 months, at Lemoore, California. Major field-representative factors considered here for the close replication in the chamber include: the use of dust collected from modules surfaces at the outdoor sites to give the same dust chemistry; dust particle size distribution and concentration; the charge size of dust (< 0.15 g per injection); field humidity, and module temperature. The effectiveness of antisoiling coatings (or surface properties) for both sample sets were ranked in the artificial testing and were found to be closely matching with the field rank orders of the respective sites and sample sets. This paper provides the rank ordering results to objectively demonstrate the replication of field soiling losses in the artificial soiling chamber.