Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Strategic Petroleum Reserve Cavern Leaching Monitoring CY21

Th e U.S. Strategic Petroleum Reserve (SPR) is a crude oil storage system administered by the U.S. Department of Energy. The reserve consists of 60 active storage caverns located in underground salt domes spread across four sites in Louisiana and Texas, near the Gulf of Mexico. Beginning in 2016, the SPR started executing C ongressionally mandated oil sales. The configuration of the reserve, with a total capacity of greater than 700 million barrels ( MMB ) , re quires that unsaturated water (referred to herein as ?raw? water) is injected into the storage caverns to displace oil for sales , exchanges, and drawdowns . As such, oil sales will produce cavern growth to the extent that raw water contacts the salt cavern walls and dissolves (leaches) the surrounding salt before reaching brine saturation. SPR injected a total of over 45 MMB of raw water into twenty - six caverns as part of oil sales in CY21 . Leaching effects were monitored in these caverns to understand how the sales operations may impact the long - term integrity of the caverns. While frequent sonars are the most direct means to monitor changes in cavern shape, they can be resource intensive for the number of caverns involved in sales and exchanges. An interm ediate option is to model the leaching effects and see if any concerning features develop. The leaching effects were modeled here using the Sandia Solution Mining Code , SANSMIC . The modeling results indicate that leaching - induced features do not raise co ncern for the majority of the caverns, 15 of 26. Eleven caverns, BH - 107, BH - 110, BH - 112, BH - 113, BM - 109, WH - 11, WH - 112, WH - 114, BC - 17, BC - 18, and BC - 19 have features that may grow with additional leaching and should be monitored as leaching continues in th ose caverns. Additionally, BH - 114, BM - 4, and BM - 106 were identified in previous leaching reports for recommendation of monitoring. Nine caverns had pre - and post - leach sonars that were compared with SANSMIC results. Overall, SANSMIC was able to capture the leaching well. A deviation in the SANSMIC and sonar cavern shapes was observed near the cavern floor in caverns with significant floor rise, a process not captured by SANSMIC. These results validate that SANSMIC continues to serve as a useful tool for mon itoring changes in cavern shape due to leaching effects related to sales and exchanges.

02 PETROLEUM↗

2022 Long-Term Hydrologic Monitoring Program Report for the Rio Blanco, Colorado Site

This report presents the monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) during the 2022 sampling event at the Rio Blanco, Colorado, Site, where an underground nuclear test was conducted in 1973. The test resulted in residual radionuclide contamination at the detonation depth. The 2022 sampling event included the collection of samples from onsite groundwater wells to monitor for any potential contamination that might be attributed to the Rio Blanco nuclear tests. This report summarizes the laboratory results obtained from the sampling along with the historical results since monitoring began in the 1970s. This annual report and previous reports are available on the LM public website at https://www.energy.gov/lm/rio-blanco-colorado-site. Data collected during this and previous monitoring events are available on the Geospatial Environmental Mapping System (GEMS) website at https://gems.lm.doe.gov/#site=RBL.

54 ENVIRONMENTAL SCIENCES↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

2016 Postclosure Groundwater Monitoring and Inspection Report, Central Nevada Test Area, Nevada, Subsurface Corrective Action Unit 443

This report presents the groundwater monitoring data collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) from the Central Nevada Test Area (CNTA), Nevada, Site, Subsurface Corrective Action Unit (CAU) 443 in Nye County, Nevada (Figure 1). The site was the location of an underground nuclear test in 1968, which resulted in residual contamination at and near the detonation depth of approximately 3200 feet (ft) below ground surface (bgs) that requires long-term monitoring. Responsibility for the environmental restoration and long-term monitoring was transferred from the DOE, National Nuclear Security Administration, Nevada Field Office to LM on October 1, 2006. The environmental restoration and site closure process were completed in 2015 in accordance with the Federal Facility Agreement and Consent Order (State of Nevada et al. 1996) (as amended) (FFACO) and all applicable Nevada Division of Environmental Protection (NDEP) policies and regulations. The Closure Report, Central Nevada Test Area, Subsurface Corrective Action, Unit 443 (LMS/CNT/S12760) (DOE 2016a) (Closure Report) describes LM’s plan for the long-term postclosure monitoring of radioisotope concentrations and water elevations, inspecting the site and maintaining the institutional controls (ICs), evaluating and reporting data, and documenting the site’s records and data management processes (DOE 2016a).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2019 Groundwater Monitoring Report Project Shoal Area: Subsurface Corrective Action Unit 447

The Project Shoal Area is a site in Nevada where an underground nuclear test was conducted in 1963. It later came to be known as the Shoal, Nevada, Site. Surface contamination at the site has been remediated, but investigation of groundwater contamination resulting from the test is still in the corrective action process. Annual sampling and water-level monitoring are conducted as part of the subsurface corrective action strategy, which has focused on revising the site conceptual model and evaluating the adequacy of the monitoring well network. It has also included enhancements to the monitoring well network to address uncertainties in the groundwater flow direction and the cause of rising water levels in site wells west of the shear zone since the first hydrologic characterization (HC) wells were installed in 1996. Revisions to the site conceptual model and enhancements to the monitoring strategy were provided to Nevada Division of Environmental Protection (NDEP) in the Addendum to: Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) for the Subsurface Corrective Action Unit 447 Shoal, Nevada, Site. NDEP approved the addendum to the CADD/CAP, which included an expanded contaminant boundary and compliance boundary for the site.

54 ENVIRONMENTAL SCIENCES↗

Vehicle Exhaust Monitoring Applications using loT platform

Vehicle emission is a major source of air pollution. A significant number of deaths is associated with air pollution. The existing vehicle emission monitoring system is unable to mitigate the pollution properly. Real-time pollution measurement is necessary to address the problem more precisely. The purpose of this project is to develop novel Vehicle Emission Monitoring Applications (VEMA) using the real-time measurement of pollutants from a vehicle tailpipe where exhaust gases enter the environment. As a part of the project, 2 technologies have been used for exhaust gas monitoring. First, an off-the-shelf exhaust gas monitoring prototype has been acquired. Second, a brand new platform was developed using off-the-shelf components. The project focused on predictive application for smart mobility and for large large fleet companies and enterprises. A data collection methodology was developed and tested by collecting close to 20 hours of data within Washington State under varying speeds, altitudes, road conditions etc. An approach for data curation was also used and finally, a simple Machine Learning was used for recognizing patterns between inputs such as vehicle speed and altitude and output such as NOx emission from vehicle exhaust pipe.

47 OTHER INSTRUMENTATION↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Online Monitoring Applications Enabled by Phasor Measurement Units: Technical Assistance to the Power Sectors of Southeast Asia

In this report, an overview of several online applications enabled by PMU measurements is provided. Besides a brief technical background for each application, the report also discusses control room displays and alarming methodologies used by North American organizations, and applicable standards set by the North American Electric Reliability Corporation (NERC). The five applications discussed herein are inertia monitoring, linear state estimation, voltage stability monitoring, small-signal stability monitoring, and forced oscillation monitoring.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A. Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

An Applied Strategy for Using Empirical and Hybrid Models in Online Monitoring

The monitoring of plant equipment for failure prediction is one of the key contributors to operation and maintenance (O&M) costs for a nuclear power plant (NPP) because O&M monitoring depends on labor-intensive activities that are required to meet high equipment reliability standards. These activities rely primarily on humans for information gathering, condition diagnosis, and predictive analysis. Online monitoring aims to automate these activities by relying on sensors to replace human information gathering and machine learning to replace human analysis and decision making. To facilitate automated monitoring, a systematic strategy for anomaly detection is needed to optimally use the available sensor data, empirical models, and physics-supported models. This strategy is essential to provide credible reasoning on why and when an empirical (i.e., purely data-driven) versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. The extant methods usually adopt an ad hoc trial-and-error approach that, in addition to being time-consuming and costly, is also highly subjective; it is impacted by the background and the skill set of the personnel making the decisions. Thus, such an approach cannot guarantee an optimum outcome. This represents the motivation of the current research effort, which is focused on devising a scientifically supported strategy for the optimum selection of anomaly detection methods. This report presents a detailed assessment of the main anomaly detection techniques within the empirical or hybrid method streams. Empirical methods include pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The listed techniques within these two streams represent the vast majority of techniques performed for anomaly detection. Using the techniques as outcomes, a strategy was developed to enable a systematic decision-making process to lead to one of these techniques. The strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability and suitability for training and testing, cause-effect, entropy inference, and model fitting. Each of these decision points in the strategy is explained in detail in this report with examples, along with the scientific basis behind the decisions and outcomes in common and simplified terminology. The strategy is developed for use by any NPP staff with basic engineering or science knowledge. A user-friendly graphical state flow diagram was also developed as a visual presentation of the strategy. The strategy was tested and demonstrated through two pilot projects for the application of anomaly detection at an NPP. Each pilot had two use cases: an initial case in which certain decisions were made that resulted in one or more empirical techniques and a revised use case where one or more key decisions were modified resulting in using a set of hybrid methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Neutron Fluence Monitors for The USU ATR NSUF Project

The USU (Utah State University) Advanced Test Reactor Nation Science User Facility (ATR NSUF) experiments to test the performance of hafnium-aluminum composites were conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) during cycles 149A through 151A from April 14, 2011, to February 13, 2012. Four sets of two neutron fluence monitor capsules wee irradiated in four different combinations of reactor cycles. The assemblies were irradiated in B2 position of the ATR. Neutron fluence monitors were located at 8 positions in the assemblies. These monitors were previously fabricated at Pacific Northwest National Laboratory (PNNL). After irradiation, the monitors were sent to PNNL for analysis. The measured activation rates were used to adjust the neutron spectra at each location in the assemblies to determine the best fit to the neutron fluence spectra. Radiation damage (dpa) calculations were performed at all locations using the adjusted neutron spectra. The report was revised after receipt of corrected irradiation history for Cycle 149A. A plot of the fast neutron flux as a function of height in the B2 position was also added to the report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydra: Computer Vision for Data Quality Monitoring

Hydra: Computer Vision for Data Quality Monitoring Mar 13, 2024, 4:15 PM 30m Charles B. Wang Center, Stony Brook University Poster Track 1: Computing Technology for Physics Research Poster session with coffee break Speaker Ayan Roy Description Hydra is an extensible framework for training, managing, and deploying machine learning models for near real-time data quality monitoring. It is designed to take some of the burden off of shift crews by providing ‘round-the-clock’ monitoring of plots representing the data being collected. The Hydra system is backed by a database which is leveraged for near push button training and is primarily controlled and viewed through a set of web interfaces. This web interface contains a simple-to-use web based GUI for labeling of the datasets used in training; making it possible to label thousands of images quickly and efficiently. To aid in the analysis of Hydra inferences gradCAM, a method of interpretability, is performed and overlaid on the target image, highlighting regions of interest, making diagnosis of problems much faster. Development began in 2019 for the GlueX Experiment in Hall-D, the Hydra system has grown to encompass all of the experimental halls at Jefferson Laboratory. This talk will focus on the features of Hydra as well as provide details of the challenges present with deploying to disparate experimental halls. With a roadmap of development established, Hydra aims to continue to grow in richness of feature set and expand to encompass other monitoring tasks in differing communities.

Roy, Ayan↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗