Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modernization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A summary comparison of design evaluation techniques - 270

Many nuclear power plants in the United States have recently been granted a 20 year extension to their operation license and are considering modernization. The Idaho National Laboratory is committed to successful modernizations and has been identifying and developing candidate technologies for power plants using methods that match the requirements of an integrated system validation. To do so this paper discusses current and potential workload, situation awareness and other performance methods used in evaluating control room design against the criteria defined by the Nuclear Regulatory Commission. The analysis provided is narrowed to the scope of methods surrounding the Light Water Reactor Sustainability research at the Idaho National Laboratory and therefore evaluates only a handful of the numerous methods used in control room modernizing efforts. As such, it was determined the most popular methods for measuring situation awareness, workload, and performance are measurements that rarely measure their intended construct directly and must be inferred. Physiological measures of workload have matured and become more accessible, sensitive, unobtrusive, valid, and objective but are reliant on variable technology. Situation Awareness measures possess little construct validity but eye-tracking technology is a measure progressing in sensitivity, objectivity, and continues to improve in unobtrusiveness. All things considered, this paper has identified a significant need for a more extensive review of the various performance measures used in modernizing control rooms and integrated system validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a High Fidelity System Analysis Code for Generation IV Reactors

Traditional nuclear reactor system analysis codes such as RELAP and TRAC employ an operator split methodology. In this approach, each of the physics (fluid flow, heat conduction and neutron diffusion) is solved separately and the coupling terms are done explicitly. This approach limits accuracy (first order in time at best) and makes the codes slow in running since the explicit coupling imposes stability restrictions on the time step size. These codes have been extensively tested and validated for the existing LWRs. However, for GEN IV nuclear reactor designs which tend to have long lasting transients resulting from passive safety systems, the performance is questionable and modern high fidelity simulation tools will be required. The requirement for accurate predictability is the motivation for a large scale overhaul of all of the models and assumptions in transient nuclear reactor safety simulation software. At INL we have launched an effort with the long term goal of developing a high fidelity system analysis code that employs modern physical models, numerical methods, and computer science for transient safety analysis of GEN IV nuclear reactors. Modern parallel solution algorithms will be employed through utilizing the nonlinear solution software package PETSc developed by Argonne National Laboratory. The physical models to be developed will have physically realistic length scales and time scales. The solution algorithm will be based on the physics-based preconditioned Jacobian-free Newton-Krylov solution methods. In this approach all of the physical models are solved implicitly and simultaneously in a single nonlinear system. This includes the coolant flow, nonlinear heat conduction, neutron kinetics, and thermal radiation, etc. Including modern physical models and accurate space and time discretizations will allow the simulation capability to be second order accurate in space and in time. This paper presents the current status of the development efforts as well as some results from analyzing a simplified primary system model of GNEP’s advanced burner test reactor (ABTR) designed by Argonne. Various transient analyses are performed with this simplified ABTR model to study two fundamental issues related to system analysis codes – accuracy of numeric algorithm and efficiency. The accuracy study is carried by comparing the second order method with the first order method. The results show that numerical errors in the first order method are large and it is very difficult to distinguish numerical errors from physical modeling errors. On the other hand, second order method yields small numerical errors and it is very easy to spot physical modeling errors. The efficiency study is carried out by comparing the time steps for the fully implicit solution algorithm versus CFL stability limit methods. The dynamic time steps used in a fully implicit method will adjust the time step to resolve the time scale during the various stages of a long lasting transient. This will make a computer code based on fully implicit methods run more efficiently versus a CFL stability limit method code like RELAP, in which a particle of fluid cannot cross a control volume in a single time step.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital Full-Scope Simulation of a Conventional Nuclear Power Plant Control Room, Phase 2: Installation of a Reconfigurable Simulator to Support Nuclear Plant Sustainability

The U.S. Department of Energy’s Light Water Reactor Sustainability program has developed a control room simulator in support of control room modernization at nuclear power plants in the U.S. This report highlights the recent completion of this reconfigurable, full-scale, full-scope control room simulator buildout at the Idaho National Laboratory. The simulator is fully reconfigurable, meaning it supports multiple plant models developed by different simulator vendors. The simulator is full-scale, using glasstop virtual panels to display the analog control boards found at current plants. The present installation features 15 glasstop panels, uniquely achieving a complete control room representation. The simulator is also full-scope, meaning it uses the same plant models used for training simulators at actual plants. Unlike in the plant training simulators, the deployment on glasstop panels allows a high degree of customization of the panels, allowing the simulator to be used for research on the design of new digital control systems for control room modernization. This report includes separate sections discussing the glasstop panels, their layout to mimic control rooms at actual plants, technical details on creating a multi-plant and multi-vendor reconfigurable simulator, and current efforts to support control room modernization at U.S. utilities. The glasstop simulator provides an ideal testbed for prototyping and validating new control room concepts. Equally importantly, it is helping create a standardized and vetted human factors engineering process that can be used across the nuclear industry to ensure control room upgrades maintain and even improve current reliability and safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lessons Learned from Performing a Human Factors Engineering Validation of an Upgraded Digital Control System in a Nuclear Power Plant Control Room

The United States' fleet of nuclear power plants (NPPs) have exceeded their original 40-year licenses and many are seeking license renewals to continue operations into the future. To support continued operation the Department of Energy's (DOE) Light Water Reactor Sustainability Program (LWRS) provides support for utilities to maintain and upgrade their power production capabilities. Control room modernization is one focus area, which aims to modernization the analog control rooms with digital controls and human-system interfaces (HSIs). The Turbine Control System (TCS) is a non-safety related system undergoing modernization efforts at multiple plants and utilities. Considerable human factors research efforts, comprised of expert reviews and operator in the loop studies were performed to develop human factors compliant and usable TCS. This report documents the final phase of the human factors engineering program used to design and validate the new digital TCS. According to the NUREG-0711 review guide, one of the last steps of human factors engineering program prior to implementation is human factors validation. This report details the method, results and conclusions from the human factors validation study of a collaborating utilities TCS slated to be implemented in one of their plants. One control room team consisting of two control room supervisors and two reactor operators participated in the validation. All team members had participated in the BNP TCS training program foregoing the TCS validation. Performance measures included task performance, situation awareness and workload, expert observation of any negative influences of human-system interface features on control room team performance, and interviews with the participating operators. Performance criteria were based on the performance scores and the topics identified by interviews and expert observations. The results showed that the crew using the new TCS clearly could achieve their overall objectives in the test scenarios with sufficient situation awareness. The new TCS compared to the old system provided clear improvements of the control room work regarding shell and chest warming and regarding valve and other system testing. However, a number of Human Engineering Discrepancies (HEDs) were identified. HEDs were prioritized (level 1, 2 or 3) according to potential safety, plant availability, operability or personnel performance consequences. Since no priority 1 HEDs were identified there is no HFE reason not to continue implementation of the TCS. The TCS upgrade is acceptable if the Priority 2 HEDs are resolved and dispositioned in a satisfactory way. Priority 3 HEDs should be noted and considered for future modifications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis and Planning Framework for Nuclear Plant Transformation

Commercial nuclear power in the United States has been an unqualified success by any measure, providing low cost, carbon-free, and safe baseload electricity for decades. The industry today is at the peak of its historical performance in terms of generation output, reliable operations, and demonstrated nuclear safety. However, it is no longer among the lowest-cost electric generation sources with the emergence of subsidized renewables and shale gas generation. The business model that has served the operating nuclear fleet so well over its life is now a drag on cost performance due to its reliance on a large highly skilled labor force. In contrast, digital technology and innovation are enabling dramatic efficiencies in energy production, resulting in fierce competition for a commodity such as electricity. The nuclear power industry has responded to this challenge with many initiatives to improve efficiency and modernize plant equipment, especially where reliability and obsolescence issues are pressing. However, it would be a missed opportunity to merely modernize the plant components and the work processes of an outdated business model that was formulated to manage the technology of the 1960s. Rather, the greater opportunity is to transform that business model to one that fully exploits the capabilities of modern digital technology, resulting in substantially lower production costs and sustainable market viability. One successful example of such transformation is the concept of Integrated Operations, which was introduced into the North Sea oil and gas industry a couple of decades ago when the profitability of operating these fields was severely threatened by low world petroleum prices and the high overhead of operating the offshore oil and gas platforms. This effort resulted in significant changes to how these oil fields were operated and allowed the industry to continue profitable operation of these platforms. This example has some remarkable parallels to the U.S. commercial nuclear industry as described in the next section. This report provides an analysis and planning framework for such a nuclear plant operating model transformation based on the transferable learnings from the North Sea transformation. This framework is termed Integrated Operations for Nuclear or ION. This report describes the key principles and methods of Integrated Operations and how they are being applied in a collaboration between the DOE Light Water Reactor Sustainability Program and Xcel Energy in an initiative to transform its operating model for performance improvement and long-term sustainability. It describes a method to bring the operating costs of a nuclear fleet in line with market-based pricing, transforming work functions to reduce cost with technology innovations. This initiative will continue over the next several years in the detailed development of transformative concepts for nuclear plants, which will be published as follow-up to this initial report on Integrated Operations for Nuclear.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Grid‐responsive smart manufacturing: A perspective for an interconnected energy future in the industrial sector

Abstract With the growing amount of renewable energy sources, the grid has become responsible for accounting for intermittency and the flexibility needed to utilize dynamic sources. Expensive peaking plants and energy storage systems have been proposed as ways to mitigate those problems. There is a large group of energy consumers that can respond to grid conditions. Historically, these consumers have been residential and commercial users, but with modern innovations and practices, industrial consumers have the potential to become a major player in this space. Grid‐responsive smart manufacturing can be used to utilize modern tools in manufacturing innovation as enablers for grid response. These modern tools already exist but are not widely used for industrial grid‐side energy management. This article defines grid‐responsive smart manufacturing, identifies five major barriers to its widespread implementation, and portrays the path to getting industrial users to be key players in grid stability and flexibility.

Billings, Blake W.↗

Chapter Nine - Automated Optimal Control in Energy Systems: The Reinforcement Learning Approach

With the development of smart grid technologies an increasing number of new devices and participants have joined modern energy systems and are inevitably making them more complicated and interdependent than ever. Optimally controlling such a complex energy system and maintaining its operation in a high-efficient, secure, and resilient manner are challenging tasks to the system operators. Fortunately, the revolution in deep learning and artificial intelligence (AI), both from hardware and algorithms perspectives, has provided new ideas and solutions to many previously intractable problems. As a result, this advance in computer science also sparked great research interests in utilizing AI in solving engineering problems related to the modern energy systems. Among many AI techniques, deep reinforcement learning (DRL) has demonstrated great potential for solving sequential optimization problems, which are very common in the engineering domains. Its ability to handle nonlinearity and stochasticity in controlled systems has out-competed many traditional optimal control algorithms. Therefore in this chapter, we focus on the state-of-the-art of DRL concepts and related algorithms, compare their pros and cons with traditional optimal control approaches and discuss the typical workflow for leveraging RL in solving complex problems in modern energy systems.

artificial intelligence↗

Nuclear characterization of a general-purpose instrumentation and materials testing location in TREAT

The Transient Reactor Test facility (TREAT) was constructed in the late 1950s, provided thousands of transient irradiations before being placed in standby in 1994, and resumed operations in 2017 in order to reclaim its crucial role in nuclear-heated safety research. The latter half of TREAT’s historic operation was best known for integral-scale testing of fuel specimens under postulated reactor plant accident conditions, while TREAT’s earlier history included extensive simpler phenomena identification tests that elucidated fundamental behaviors and paved the way for these integral-scale tests. Advances in modern computational capabilities and a resurgence of interest in novel reactor technology have created an opportunity for emphasizing modernized science-based and separate effects test capabilities once again at TREAT. An innovative approach to this type of testing has been developed to leverage minor radioactivity built-in during brief TREAT irradiations in low activation hardware to facilitate handling for materials and instrumentation testing. This capability, termed the Minimal Activation Retrievable Capsule Holder (MARCH) irradiation vehicle system, will be used for inaugural fueled experiments in TREAT’s modern era as well as novel approaches to study materials undergoing neutron irradiation and instrumentation development and qualifications. This paper describes a comprehensive nuclear characterization, obtained via computational modeling, of the test position in the MARCH system. Though directly applicable to the MARCH system, the results also provide general quantification of the nuclear performance of the reactor and potential test materials, crucial for evaluating potential experiment design and response in TREAT. The neutron and photon flux environment was calculated via MCNP with ENDF/B-VII.1 nuclear data. Wire heating rate and DPA calculations were also performed and evaluated using historic TREAT test data. Furthermore, these calculations were performed to provide steady-state baseline reference values typical in both half- and full-slotted TREAT core configurations, enabling design scoping analysis prior to development of more specific design testing needs and transient testing experimentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A computer vision algorithm for interpreting lacustrine carbonate textures at Searles Valley, USA

Investigations of the paleohydrologies of pluvial lake systems have often employed lake carbonate deposits called “tufa” that grow subaqueously and can be preserved long after the drying of the lake. For this reason, tufa have been used as a proxy for minimum lake level. However, they exhibit a variety of textures that hold the potential to reveal richer paleoclimatological information. With the goal of determining if tufa texture can be used as a proxy for lake environment, this study investigates the textures of tufa at Mono Lake, California in comparison to the fossil tufa in Searles Valley, California. While observations in the last century suggest that the tufa in the Mono basin grew in waters similar to the modern, the tufa at Searles formed during the last glacial period, when the Great Basin contained a system of pluvial lakes on the scale of the modern Great Lakes. The tufa at both basins have been observed to have a range of classifiable textures, and new methods of inspecting visual data could be informative about what factors control these textures. To this end, a t-Distributed Stochastic Neighbor Embedding (t-SNE) algorithm is used to project images of the tufa at Searles and Mono into a coordinate space, allowing for simple, quantitative comparisons of the visual similarity of textures. In this work, the textures of tufa at Searles are compared to each other, as well as to the tufa at Mono. This study performs a robust assessment of the feasibility of Mono Lake as a modern analogue for Searles Valley. It finds that there is a justifiable basis for the comparison of certain fossil facies at Searles to the tufa at Mono, significant progress towards the goal of using texture as a metric for the environment in which tufa formed.

58 GEOSCIENCES↗

The circulation of the Dead Sea brine in the regional aquifer

It is known that Ca-chloride brines have circulated between the lakes and the adjacent aquifers throughout the history of the Dead Sea lacustrine-hydrology system. Here, the Ein-Qedem (EQ) hydrothermal saline springs system discharging at the western shores of the modern Dead Sea is the modern manifestation of this essential and continuous process. The EQ springs comprise the most significant source of Ca-chloride brine that currently discharges into the lake. The chemical composition of EQ brine has remained virtually uniform during the past ca. 40 yr, indicating that the brine represents a large groundwater reservoir. The EQ brine evolved from ancient Ca-chloride brine that occupied the tectonic depression of the Dead Sea Basin during the Quaternary. During this period, the composition of lake's brine was affected by mixing with freshwater and formation of primary minerals. Based on chronological and geochemical data, we argue that the EQ brine comprises the epilimnetic solution of last glacial Lake Lisan that penetrated and circulated through the adjacent Judea Group aquifer. 14 C and 81 Kr dating indicates recharge ages spanning the time interval of similar to 40-20 ka, coinciding with the period when the lake reached its highest stand (of similar to 200 +/- 30 m below msl, at similar to 31-17.4 ka) and maintained a stable layered (stratified) configuration for a period of several ten thousand years. The presented evidence suggests that the circulation of the Ca-chloride brine involves penetration into the aquifer during high stands (EQ brine recharge) and its discharge back into the lake during the modern low stands (similar to 400 to 430 m below msl). Accordingly, the mechanism of brine circulation between the lake and the marginal aquifers is related to the long-term hydro-climate history of the Dead Sea basin and its vicinity.

58 GEOSCIENCES↗

Errors in Radiotherapy: Motivation for Development of New Radiotherapy Quality Assurance Paradigms

Modern radiotherapy practice has rapidly evolved during the past decade, making use of many highly complex and/or automated processes for planning and delivery, including new techniques, like intensity-modulated radiotherapy driven by inverse planning optimization methods, or near real-time image-guided adaptive therapy based on fluoroscopic or tomographic imaging on the treatment machine. In spite of the modern technology, or potentially because of it in some instances, errors and other problems continue to have a significant impact on the field. This report reviews example errors and problems, discusses some of the quality assurance issues that these types of problems raise, and motivates the development of more modern and sophisticated approaches to assure quality for our clinical radiotherapy treatment methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decision Regret in Men Undergoing Dose-Escalated Radiation Therapy for Prostate Cancer

Purpose: Decision regret (DR) is a negative emotion associated with medical treatment decisions, and it is an important patient-centered outcome after therapy for localized prostate cancer. DR has been found to occur in up to 53% of patients treated for localized prostate cancer, and it may vary depending on treatment modality. DR after modern dose-escalated radiation therapy (DE-RT) has not been investigated previously, to our knowledge. Our primary aim was to evaluate DR in a cohort of patients treated with DE-RT. Methods and Materials: We surveyed 257 consecutive patients with localized prostate cancer who had previously received DE-RT, by means of a validated questionnaire. Results: There were 220 responses (85.6% response rate). Image-guided intensity modulated radiation therapy was given in 85.0% of patients and 3-dimensional conformal radiation therapy in 15.0%. Doses received included 73.8 Gy (34.5% patients), 74 Gy (53.6%), and 76 Gy (10.9%). Neoadjuvant androgen deprivation (AD) was given in 51.8% of patients and both neoadjuvant and adjuvant AD in 34.5%. The median follow-up time was 23 months (range, 12-67 months). In all, 3.8% of patients expressed DR for their choice of treatment. When asked whether they would choose DE-RT or AD again, only 0.5% probably or definitely would not choose DE-RT again, compared with 8.4% for AD (P<.01). Conclusion: Few patients treated with modern DE-RT express DR, with regret appearing to be lower than in previously published reports of patients treated with radical prostatectomy or older radiation therapy techniques. Patients experienced more regret with the AD component of treatment than with the radiation therapy component, with implications for informed consent. Further research should investigate regret associated with individual components of modern therapy, including AD, radiation therapy and surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Decade of Comparative Dose Planning Studies for Early-Stage Hodgkin Lymphoma: What Can We Learn?

During the past 4 decades, the treatment of Hodgkin lymphoma has changed dramatically, and combined modality treatment is now considered the standard of care for patients with early-stage disease. However, the risk of late effects has led to concerns regarding the use of radiation therapy, especially in young patients with a long life expectancy. In this study, we review the current evidence for modern radiation therapy planning and delivery techniques in the treatment of early-stage Hodgkin lymphoma with a focus on a reduced delivered dose, a reduced irradiated volume, and a more conformal dose distribution. Although studies are difficult to compare because of differences in field technique, prescribed dose, target volumes, patient population, and reported dosimetric and plan evaluation parameters, modern radiation therapy significantly reduces exposure to normal tissues and thereby the estimated risk of late effects. However, there is no such thing as a single best modern delivery technique when multiple organs at risk are considered simultaneously because of the heterogeneity in patient anatomy and disease location, and the choice of radiation therapy technique should be made individually for each patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massively parallel transport sweeps on meshes with cyclic dependencies

When solving the first-order form of the linear Boltzmann equation, a common misconception is that the matrix-free computational method of “sweeping the mesh”, used in conjunction with the Discrete Ordinates method, is too complex or does not scale well enough to be implemented in modern high performance computing codes. This has led to considerable efforts in the development of matrix-based methods that are computationally expensive and is partly driven by the requirements placed on modern spatial discretizations. In particular, modern transport codes are required to support higher order elements, a concept that invariably adds a lot of complexity to sweeps because of the introduction of cyclic dependencies with curved mesh cells. In this article we will present a comprehensive implementation of sweeping, to a piecewise-linear DFEM spatial discretization with particular focus on handling cyclic dependencies and possible extensions to higher order spatial discretizations. We find that these methods are implemented in a new C++ simulation framework called Chi-Tech (). We present some typical simulation results with some performance aspects that one can expect during real world simulations, we also present a scaling study to >100k processes where Chi-Tech maintains greater than 80% efficiency solving a total of 87.7 trillion angular flux unknowns for a 116 group simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An international initiative on long-term behavior of high-level nuclear waste glass

Nations using borosilicate glass as an immobilization material for radioactive waste have reinforced the importance of scientific collaboration to obtain a consensus on the mechanisms controlling the long-term dissolution rate of glass. This goal is deemed to be crucial for the development of reliable performance assessment models for geological disposal. The collaborating laboratories all conduct fundamental and/or applied research using modern materials science techniques. This paper briefly reviews the radioactive waste vitrification programs of the six participant nations and summarizes the current state of glass corrosion science, emphasizing the common scientific needs and justifications for on-going initiatives.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model Order Reduction Algorithm for Estimating the Absorption Spectrum

The ab initio description of the spectral interior of the absorption spectrum poses both a theoretical and computational challenge for modern electronic structure theory. Due to the often spectrally dense character of this domain in the quantum propagator’s eigenspectrum for medium-to-large sized systems, traditional approaches based on the partial diagonalization of the propagator often encounter oscillatory and stagnating convergence. Electronic structure methods which solve the molecular response problem through the solution of spectrally shifted linear systems, such as the complex polarization propagator, offer an alternative approach which is agnostic to the underlying spectral density or domain location. This generality comes at a seemingly high computational cost associated with solving a large linear system for each spectral shift in some discretization of the spectral domain of interest. In this work, we present a novel, adaptive solution to this high computational overhead based on model order reduction techniques via interpolation. Model order reduction reduces the computational complexity of mathematical models and is ubiquitous in the simulation of dynamical systems and control theory. The efficiency and effectiveness of the proposed algorithm in the ab initio prediction of X-ray absorption spectra is demonstrated using a test set of challenging water clusters which are spectrally dense in the neighborhood of the oxygen K-edge. On the basis of a single, user defined tolerance we automatically determine the order of the reduced models and approximate the absorption spectrum up to the given tolerance. We also illustrate that, for the systems studied, the automatically determined model order increases logarithmically with the problem dimension, compared to a linear increase of the number of eigenvalues within the energy window. Furthermore, we observed that the computational cost of the proposed algorithm only scales quadratically with respect to the problem dimension.

IDREAM, K-Edge, theoretical, computational, electr↗