Label-Free Chemical Imaging of Catalytic Solids by Coherent Anti-Stokes Raman Scattering and Synchrotron-Based Infrared Microscopy

Take a look inside: The combination of coherent anti-Stokes Raman scattering and synchrotron-based IR microscopy during the catalytic conversion of thiophene derivatives on zeolite crystals yields space- and time-resolved chemically specific information without the need for labeling (see picture). The thiophene reactant is mostly present in the center of the crystal, and the product is aligned within the straight pores of the zeolites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deactivation of Cu-Exchanged Automotive-Emission NH 3 -SCR Catalysts Elucidated with Nanoscale Resolution Using Scanning Transmission X-ray Microscopy

To gain insight into the underlying mechanisms of catalyst durability for the selective catalytic reduction (SCR) of NO x with an ammonia reductant, we employed scanning transmission X-ray microscopy (STXM) to study Cu-exchanged zeolites with the CHA and MFI framework structures before and after simulated 135 000-mile aging. X-ray absorption near-edge structure (XANES) measurements were performed at the Al K- and Cu L-edges. The local environment of framework Al, the oxidation state of Cu, and geometric changes were analyzed, showing a multi-factor-induced catalytic deactivation. In Cu-exchanged MFI, a transformation of Cu II to Cu I and Cu x O y was observed. We also found a spatial correlation between extra-framework Al and deactivated Cu species near the surface of the zeolite as well as a weak positive correlation between the amount of CuI and tri-coordinated Al. By inspecting both Al and Cu in fresh and aged Cu-exchanged zeolites, we conclude that the importance of the preservation of isolated Cu II sites trumps that of Brønsted acid sites for NH 3 -SCR activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro‐ and Nanoscale Heterogeneities in Zeolite Beta as Measured by Atom Probe Tomography and Confocal Fluorescence Microscopy

Micro- and nanoscale information on the activating and deactivating coking behaviour of zeolite catalyst materials increases our current understanding of many industrially applied processes, such as the methanol-to-hydrocarbon (MTH) reaction. Atom probe tomography (APT) was used to reveal the link between framework and coke elemental distributions in 3D with sub-nanometre resolution. APT revealed 10–20 nanometre-sized Al-rich regions and short-range ordering (within nanometres) between Al atoms. With confocal fluorescence microscopy, it was found that the morphology of the zeolite crystal as well as the secondary mesoporous structures have a great effect on the microscale coke distribution throughout individual zeolite crystals over time. Additionally, a nanoscale heterogeneous distribution of carbon as residue from the MTH reaction was determined with carbon-rich areas of tens of nanometres within the zeolite crystals. Finally, a short length-scale affinity between C and Al atoms, as revealed by APT, indicates the formation of carbon-containing molecules next to the acidic sites in the zeolite.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Situ Characterization of Dynamic Morphological and Phase Changes of Selenium-doped Germanium Using a Single Particle Cell and Synchrotron Transmission X-ray Microscopy

The dynamic information of lithium-ion battery active materials obtained from coin cell-based in-situ characterizations might not represent the properties of the active material itself because many other factors in the cell could have impacts on the cell performance. To address this problem, a single particle cell was developed to perform the in-situ characterization without the interference of inactive materials in the battery electrode as well as the X-ray-induced damage. In this study, the dynamic morphological and phase changes of selenium-doped germanium (Ge 0.9 Se 0.1 ) at the single particle level were investigated via synchrotron-based in-situ transmission X-ray microscopy. The results demonstrate the good reversibility of Ge 0.9 Se 0.1 at high cycling rate that helps understand its good cycling performance and rate capability. This in-situ and operando technique based on a single particle battery cell provides an approach to understanding the dynamic electrochemical processes of battery materials during charging and discharging at the particle level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale properties of lead halide perovskites by scanning tunneling microscopy

Since the introduction of lead halide perovskites, tremendous progress has been made regarding their stability, reproducibility and durability. However, one of the issues that remains is related to the interfacial atomic structure arrangement and structure-property relationship under optical and electrical stimuli. In this critical review, we highlight the recent progress using scanning tunneling microscopy (STM) to understand the nanoscale properties and dynamic processes occurring in these halide perovskite materials. STM is known to be a very challenging technique, which is reflected by the low number of relevant publications in the last years. These initial reports mirror the unique potential of STM to give Ångstrom-scale insight into the (opto)-electronic properties, morphology and underlying electronic structure and provide a path toward harnessing the full potential of these materials. However, care must be taken to understand the effects of the perturbations caused by STM and tailor the measurement conditions accordingly.

36 MATERIALS SCIENCE↗

Imaging of surface nanobubbles by atomic force microscopy in liquids: Influence of drive frequency on the characterization of ultrasoft matter: Surface Nanobubbles and Soft Matter by AFM

Imaging of soft matter with atomic force microscopy (AFM) is challenging due to tip-induced deformation, which convolutes with the measurement. The challenges are generally more serious in liquid environments due to a severe loss of sensitivity of the vibrating microcantilever to external forces, as well as due to the presence of undesirable mechanical resonances when piezoelectric excitation systems are used. Furthermore, the choice of imaging parameters can have a significant impact on the quality of the results, such that the customary practices used for tuning the cantilever are not always appropriate. Here we explore the influence of the chosen drive frequency on the imaging of ultrasoft matter, using surface gas nanobubbles on gold-coated glass and highly oriented pyrolytic graphite (HOPG) as a test platform. We carry out single- and multifrequency AFM experiments using both the traditional amplitude-peak method and the recently proposed phase-slope-peak method for tuning the cantilever, as well as piezoelectric and photothermal excitation, providing an extensive discussion on the factors governing the level of tip-induced sample deformation and the quality of the phase contrast obtained for each of the methods. The general conclusion is that there is no “one-size-fits-all” approach for tuning the cantilever for low-impact tapping-mode AFM, although rational optimization of the imaging process is generally possible, whereby the choice of the drive frequency plays a prominent role. The physical insight and guidelines provided here can be extremely useful for the gentle imaging of a wide range of biological and other soft materials in liquid environments. Microsc. Res. Tech. 80:41–49, 2017.

42 ENGINEERING↗

Measuring the dynamic response of the thylakoid architecture in plant leaves by electron microscopy

The performance of the photosynthesis machinery in plants, including light harvesting, electron transport, and protein repair is controlled by structural changes of the thylakoid membrane system inside the chloroplasts. In particular, the structure of the stacked grana area of thylakoid membranes is highly dynamic, changing in response to different environmental cues such as light intensity. For example, the aqueous thylakoid lumen enclosed by thylakoid membranes in grana has been documented to swell in the presence of light. However, light-induced alteration of the stromal gap in the stacked grana (partition gap) and of the unstacked stroma lamellae have not been well characterized. Light-induced changes of the entire thylakoid membrane system including the lumen in both stacked and unstacked domains as well as the partition gap are presented here, and the functional implications are discussed. This structural analysis was made possible by development of a robust semi-automated image analysis method combined with optimized plant tissue fixation techniques for transmission electron microscopy generating quantitative structural results for the analysis of thylakoid ultrastructure.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-Scaled Microstructures in Natural Rubber Characterized by Synchrotron X-ray Scattering and Optical Microscopy

Multi-scaled microstructures induced by natural impurities (i.e., proteins, phospholipids, carbohydrates) in natural rubber (NR) were investigated by synchrotron small-angle X-ray scattering (SAXS), wide-angle X-ray diffraction (WAXD), and optical microscopy using several kinds of untreated and chemically treated un-vulcanized samples. These microstructures include large aggregates (size less than 50 m), well-defined crystals (size less than a few 10 m), and micelles (size much less than 10 m). In un-vulcanized NR samples, even though the concentrations of natural impurities are relatively low, the dispersion of these microstructures significantly affects the mechanical properties

43 PARTICLE ACCELERATORS↗

Prevention of nanoscale wear in atomic force microscopy through the use of monolithic ultrananocrystaline diamond probes.

Nanoscale wear is a key limitation of conventional atomic force microscopy (AFM) probes that results in decreased resolution, accuracy, and reproducibility in probe-based imaging, writing, measurement, and nanomanufacturing applications. Diamond is potentially an ideal probe material due to its unrivaled hardness and stiffness, its low friction and wear, and its chemical inertness. However, the manufacture of monolithic diamond probes with consistently shaped small-radius tips has not been previously achieved. The first wafer-level fabrication of monolithic ultrananocrystalline diamond (UNCD) probes with <5-nm grain sizes and smooth tips with radii of 30-40 nm is reported, which are obtained through a combination of microfabrication and hot-filament chemical vapor deposition. Their nanoscale wear resistance under contact-mode scanning conditions is compared with that of conventional silicon nitride (SiN{sub x}) probes of similar geometry at two different relative humidity levels ({approx}15 and {approx}70%). While SiN{sub x} probes exhibit significant wear that further increases with humidity, UNCD probes show little measurable wear. The only significant degradation of the UNCD probes observed in one case is associated with removal of the initial seed layer of the UNCD film. The results show the potential of a new material for AFM probes and demonstrate a systematic approach to studying wear at the nanoscale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Signal Origin of Electrochemical Strain Microscopy and Link to Local Chemical Distribution in Solid State Electrolytes

Electrochemical strain microscopy (ESM) is a distinguished method to characterize Li-ion mobility in energy materials with extremely high spatial resolution. The exact origin of the cantilever deflection when the technique is applied on solid state electrolytes (SSEs) is currently discussed in the literature. Under-standing local properties and influences on ion mobility in SSEs is of utmost importance to improve such materials for next generation batteries. Here, the exact signal formation process of ESM when applied on sodium super ionic conductor (NASICON)-type SSE containing Na- and Li-ions is investigated. Changes in the dielectric properties, which are linked to the local chemical composition, are found to be responsible for the observed contrast in the deflection of the cantilever instead of a physical volume change as a result of Vegard´s Law. The cantilever response is strongly reduced in areas of high sodium content which is attributed to a reduction of the tip-sample capacitance in comparison to areas with high lithium content. This is the first time a direct link between electrostatic forces in contact mode and local chemical information is demonstrated on SSEs. Furthermore, the results open up new possibilities in information gain since dielectric proper-ties are sensitive to subtle changes in local chemical composition.

36 MATERIALS SCIENCE↗

Probing the Mechanical Properties of 2D Materials via Atomic‐Force‐Microscopy‐Based Modulated Nanoindentation

Abstract As the field of low‐dimensional materials (1D or 2D) grows and more complex and intriguing structures are continuing to be found, there is an emerging need for techniques to characterize the nanoscale mechanical properties of all kinds of 1D/2D materials, in particular in their most practical state: sitting on an underlying substrate. While traditional nanoindentation techniques cannot accurately determine the transverse Young's modulus at the necessary scale without large indentations depths and effects to and from the substrate, herein an atomic‐force‐microscopy‐based modulated nanomechanical measurement technique with Angstrom‐level resolution (MoNI/ÅI) is presented. This technique enables non‐destructive measurements of the out‐of‐plane elasticity of ultra‐thin materials with resolution sufficient to eliminate any contributions from the substrate. This method is used to elucidate the multi‐layer stiffness dependence of graphene deposited via chemical vapor deposition and discover a peak transverse modulus in two‐layer graphene. While MoNI/ÅI has been used toward great findings in the recent past, here all aspects of the implementation of the technique as well as the unique challenges in performing measurements at such small resolutions are encompassed.

2D materials↗

Correlated X‐Ray and Electron Microscopies of a Single Biphasic GaAs Nanowire

Engineering the properties of semiconductors by changing their crystalline phase is a technologically and economically relevant alternative to doping using foreign elements, with strong potential for photonic and electronic applications. Although major advances have been reported recently for crystal‐phase engineering of III‐V and group IV semiconductor nanowires, interfacing two mismatched crystalline phases in a nanostructure induces several deformation mechanisms, which remain largely unexplored. Here, using state‐of‐the‐art synchrotron X‐ray nanobeam diffraction and transmission electron microscopy, subtle twisting and bending is unveiled within an individual GaAs nanowire containing cubic and hexagonal segments. Their role is discussed in accommodating the inter‐reticular spacing fluctuations, and their variations are correlated to the nanoscale phase distribution and to the effect of the NW support. This study brings direct evidence of a complex combination of deformation mechanisms in biphasic nanowires, which opens a new path to tune the nanowire properties with appealing perspectives for device engineering in nanophotonics and nanomechanics.

III-V semiconductors↗

A Machine Learning Approach to Quantitative Analysis of Enamel Microstructure from Scanning Electron Microscopy Images

Dental enamel, the outermost tissue of mammalian teeth, must withstand a lifetime of wear and cyclic contact. To meet this demand, enamel possesses a combination of high hardness and resistance to fracture, properties that are typically mutually exclusive. The impressive damage tolerance has been attributed largely to decussation of the enamel rods, the principal unit of its microstructure. As such, enamel is inspiring the design of next‐generation structural materials. However, quantitative descriptions of the decussated enamel rod microstructure remain limited due to challenges encountered in applying computed tomography and in acquiring quality images appropriate for traditional digital processing methods. Here, a machine learning segmentation method is applied to images of the enamel obtained using scanning electron microscopy to support quantitative analysis of the microstructure. A pretrained convolutional neural network is used to expand the input training image dataset to allow the training of a random forest classifier, which ultimately segments the image with a very small training set ( n = 3 images). A validation of this segmentation method is presented, in addition to its application to calculate relevant microstructural parameters for images of tooth enamel from selected mammalian species. The methodology applied here is equally applicable to other hard tissues.

36 MATERIALS SCIENCE↗

High-Resolution Imaging of Cellulose Organization in Cell Walls by Field Emission Scanning Electron Microscopy

Field emission scanning electron microscopy (FESEM) is a powerful tool for analyzing surface structures of biological and nonbiological samples. However, when it is used to study fine structures of nanometer-sized microfibrils of epidermal cell walls, one often encounters tremendous challenges to acquire clear and undistorted images because of two major issues: (1) Preparation of samples suitable for high resolution imaging; due to the delicateness of some plant materials, such as onion epidermal cell walls, many things can happen during sample processing, which subsequently result in damaged samples or introduce artifacts. (2) Difficulties to acquire clear images of samples which are electron-beam sensitive and prone to charging artifacts at magnifications over 100,000×. In this chapter we described detailed procedures for sample preparation and conditions for high-resolution FESEM imaging of onion epidermal cell walls. Lastly, the methods can be readily adapted for other wall materials.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing the Number of Kinesin Motors Bound to Microtubules in the Gliding Motility Assay Using FLIC Microscopy [Book Chapter]

Intracellular transport by kinesin motors moving along their associated cytoskeletal filaments, microtubules, is essential to many biological processes. This active transport system can be reconstituted in vitro with the surface-adhered motors transporting the microtubules across a planar surface. In this geometry, the kinesin-microtubule system has been used to study active self-assembly, to power microdevices, and to perform analyte detection. Fundamental to these applications is the ability to characterize the interactions between the surface tethered motors and microtubules. Further, Fluorescence Interference Contrast (FLIC) microscopy can illuminate the height of the microtubule above a surface, which, at sufficiently low surface densities of kinesin, also reveals the number, locations, and dynamics of the bound motors.

59 BASIC BIOLOGICAL SCIENCES↗

Image-Guided Cryoablation of the Spine in a Swine Model: Clinical, Radiological, and Pathological Findings with Light and Electron Microscopy

PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface structure of manganese gallium quantum height islands on wurtzite ${\mathbf {GaN}}{\mathbf{(000}}{\bar{\mathbf{1}}})$ studied by scanning tunneling microscopy

Submonolayer deposition of manganese on gallium-rich, nitrogen polar \(\hbox {GaN}(000\bar{1})\) surface using radio-frequency nitrogen plasma molecular beam epitaxy leads to the spontaneous formation of manganese gallium into two distinct quantum height islands, 5-layer and 6-layer islands. Atomically resolved scanning tunneling microscopy reveals the atomically flat but unstable 5-layer island surface and the 6-layer island surface with relatively stable row structures. We present here possible surface models for these islands’ surfaces and discuss the clear structural differences explained with strains and partial relaxations. It is discovered that the 5-layer islands form under lateral strains and a relaxation process leading to non-uniform alternating strains results in the more energetically favorable row structures on the 6-layer island.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗