Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Multiple ferroic orders and toroidal magnetoelectricity in the chiral magnet BaCoSiO 4

Discovering ferroic phase transitions and their consequential physical properties is at the core of condensed matter science due to rich physics and tremendous technological promises. BaCoSiO 4 , a chiral antiferromagnet, belongs to the tetrahedron-based chiral system, and exhibits diverse ferroic orders with coexisting chirality, polarity, trimerization, ferrorotational distortions, and magnetism. However, their mutual couplings remain to be explored. Here in this work, we used a comprehensive combination of several experimental tools—in situ x-ray, transmission electron microscopy, magnetization, and magnetoelectric measurements of single-crystalline BaCoSiO 4 —to investigate hierarchical phase transitions, their microscopic domain structures, and the resulting magnetoelectricity. We found that two different structural chiralities develop through distinct processes: global homochirality and local heterochirality induced by the ferrorotational distortions on top of existing polarization. In addition, magnetic chirality, with the simultaneous presence of net magnetic moment and magnetic toroidal moment, develops below 3.2 K due to the global chirality, which leads to magnetic field tunable toroidal magnetoelectricity. Thus, BaCoSiO 4 exhibits uniquely all four types of ferroic orders and provides an avenue to explore, for example, tunable or dynamic coupling of multiple ferroic degrees of freedom.

36 MATERIALS SCIENCE↗

Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible {sup 3}He/10 T cryostat

The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped {sup 3}He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning electron microscopy image representativeness: morphological data on nanoparticles

Summary A sample of a nanomaterial contains a distribution of nanoparticles of various shapes and/or sizes. A scanning electron microscopy image of such a sample often captures only a fragment of the morphological variety present in the sample. In order to quantitatively analyse the sample using scanning electron microscope digital images, and, in particular, to derive numerical representations of the sample morphology, image content has to be assessed. In this work, we present a framework for extracting morphological information contained in scanning electron microscopy images using computer vision algorithms, and for converting them into numerical particle descriptors. We explore the concept of image representativeness and provide a set of protocols for selecting optimal scanning electron microscopy images as well as determining the smallest representative image set for each of the morphological features. We demonstrate the practical aspects of our methodology by investigating tricalcium phosphate, Ca 3 (PO 4 ) 2 , and calcium hydroxyphosphate, Ca 5 (PO 4 ) 3 (OH), both naturally occurring minerals with a wide range of biomedical applications.

ODZIOMEK, KATARZYNA↗

Microstructure of RERTR Du-Alloys Irradiated with Krypton Ions up to 100 dpa

The radiation stability of the interaction product formed at the fuel–matrix interface of research reactor dispersion fuels, under fission-product bombardment, has a strong impact on fuel performance. Three depleted uranium alloys were cast that consisted of the following five phases to be investigated: U(Si, Al)3, (U, Mo)(Si, Al)3, UMo2Al20, U6Mo4Al43, and UAl4. Irradiation of transmission electron microscopy (TEM) disc samples with 500-keV Kr ions at 200 °C to doses up to 100 displacements per atom (dpa) were conducted using a 300-keV electron microscope equipped with an ion accelerator. TEM results show that the U(Si, Al)3 and UAl4 phases remain crystalline at 100 dpa without forming voids. The (U, Mo)(Si, Al)3 and UMo2Al20 phases become amorphous at 1 and 2 dpa, respectively, and show no evidence of voids at 100 dpa. The U6Mo4Al43 phase goes to amorphous at less than 1 dpa and reveals high density voids at 100 dpa.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Controlled polarity of sputter-deposited aluminum nitride on metals observed by aberration corrected scanning transmission electron microscopy

The polarity determination process of sputter-deposited aluminum nitride (AlN) on metals has been analyzed using aberration corrected atomic resolution scanning transmission electron microscope. Direct growth of c-axis orientated AlN on face centered cubic metals (fcc) (111) with the local epitaxy has been observed, and the polarity was determined at the AlN/metal interface. We found that the AlN polarity can be controlled by the base metal layer: N-polarity AlN grows on Pt(111) while Al-polarity AlN forms on Al(111). Based on these results, the growth mechanism of AlN on metals is discussed.

36 MATERIALS SCIENCE↗

Force feedback microscopy based on an optical beam deflection scheme

Force feedback microscopy circumvents the jump to contact in atomic force microscopy when using soft cantilevers and quantitatively measures the interaction properties at the nanoscale by simultaneously providing force, force gradient, and dissipation. The force feedback microscope developed so far used an optical cavity to measure the tip displacement. In this Letter, we show that the more conventional optical beam deflection scheme can be used to the same purpose. With this instrument, we have followed the evolution of the Brownian motion of the tip under the influence of a water bridge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of carbon nanostructures in nuclear graphite under high-temperature in situ electron-irradiation

Defect evolution in nuclear graphite has been studied in real time using high-temperature in situ transmission electron microscopy. In situ electron-irradiation was conducted at 800 °C on a 200 kV transmission electron microscope with a dose rate, given in terms of displacements per atom per second, of approximately 1.46 × 10 –3 dpa/s. Defect domains consisting of ordered arrangements of pentagons, hexagons, and heptagons exist intrinsically in nuclear graphite and in addition are readily produced via electron-irradiation; however, at elevated temperatures these defect domains undergo atomic rearrangements resulting in the formation of carbon nanostructures via curling and closure of the basal planes. The formation of fullerenes and other structures due to thermal annealing or high-temperature electron-irradiation has been observed in disordered regions of the microstructure and interstitially between basal planes. Furthermore, these defect structures result in localized swelling and expansion of crystallites along the c axis; thus, it is proposed as one of the many atomic mechanisms involved in the dimensional change of nuclear graphite subjected to high-temperature irradiation.

36 MATERIALS SCIENCE↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Eutectic nucleation in hypoeutectic Al-Si alloys

The nucleation mechanism of eutectic grains in hypoeutectic Al-Si foundry alloys has been investigated by examining deep etched specimens in high-resolution field emission gun scanning electron microscope (FEG-SEM) and by using in-situ Focused Ion Beam (FIB) milling and microscopy. Both unmodified and Sr-modified alloys were studied to characterize the nucleation mechanism of eutectic silicon flakes and fibers. It is proposed that following nucleation of eutectic Al on the primary {alpha}-Al dendrites, fine Si particles form at the solidification front upon which the eutectic Si flakes and fibers could develop. The formation of small Si particles is attributed to Si enrichment of the remaining melt due to the formation of eutectic Al (aluminum spikes) at the eutectic temperature. A hypothesis is then proposed to explain the mechanism of eutectic grains formation with main emphasis on the eutectic Si phase.

36 MATERIALS SCIENCE↗

A melting-like process and the local structures during the anatase-to-rutile transition

Highlights: • The maximum size of anatase crystallites is more useful to describe the phase stability than the traditional critical size. • The melting-like process accelerates the phase transition from anatase to rutile. • The cis-coordinated anatase is transformed to trans-coordinated rutile by torsion & rotation of TiO{sub 6} octahedra in anatase. Phase transition of titanium oxide from anatase to rutile was investigated by using transmitted electron microscope (TEM), scanning electron microscope (SEM) and X-ray diffraction (XRD), in combination with the atomic pair distribution function (PDF) technique. The transition range is about 528–805 °C and the critical size is ~73 nm for the sol-gel samples calcined for 6 h. A melting-like process was evidently observed in the transition samples by SEM and it will speed up the phase transition. PDF reveals that anatase crystallites are packed by neighbouring TiO{sub 6} octahedra in a cis-coordinated way. Anatase crystallites larger than the critical size will be unstable and transform into rutile in a trans-coordinated way by torsion and rotation of part of octahedra and it will rapidly spread the entire crystallites driven by a melting-like process. We suggest the maximum size of anatase will be more technically useful for the description of the phase stability from anatase to rutile because unstable small anatase crystals are consumed during longer calcination process to grow the larger anatase crystals.

36 MATERIALS SCIENCE↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

MICROSCOPIC DYNAMICS AT THE GLASS TRANSITION: INSIGHTS FROM SOFT COLLOIDAL DISPERSIONS

We investigate the microscopic dynamics of compressible colloidal particles as function of concentration through dynamic light scattering and confocal microscopy experiments. In analogy with hard sphere (HS) colloidal systems, we find that the particles display liquid, supercooled liquid or glassy dynamics, depending on volume fraction. In the present case, however caging effects are observed for particle volume fractions higher than one, i.e. when the particles are compressed. We find that heterogeneous dynamics, described by a non Gaussian distribution of the displacements, play a major role in the supercooled liquid in proximity of the relaxation time.

36 MATERIALS SCIENCE↗

Dynamic compressive behavior of Pr-Nd alloy at high strain rates and temperatures

Based on compressive tests, static on 810 material test system and dynamic on the first compressive loading in split Hopkinson pressure bar (SHPB) tests for Pr-Nd alloy cylinder specimens at high strain rates and temperatures, this study determined a J-C type [G. R. Johnson and W. H. Cook, in Proceedings of Seventh International Symposium on Ballistics (The Hague, The Netherlands, 1983), pp. 541-547] compressive constitutive equation of Pr-Nd alloy. It was recorded by a high speed camera that the Pr-Nd alloy cylinder specimens fractured during the first compressive loading in SHPB tests at high strain rates and temperatures. From high speed camera images, the critical strains of the dynamic shearing instability for Pr-Nd alloy in SHPB tests were determined, which were consistent with that estimated by using Batra and Wei's dynamic shearing instability criterion [R. C. Batra and Z. G. Wei, Int. J. Impact Eng. 34, 448 (2007)] and the determined compressive constitutive equation of Pr-Nd alloy. The transmitted and reflected pulses of SHPB tests for Pr-Nd alloy cylinder specimens computed with the determined compressive constitutive equation of Pr-Nd alloy and Batra and Wei's dynamic shearing instability criterion could be consistent with the experimental data. The fractured Pr-Nd alloy cylinder specimens of compressive tests were investigated by using 3D supper depth digital microscope and scanning electron microscope.

36 MATERIALS SCIENCE↗

Three-dimensional fabrication and characterisation of core-shell nano-columns using electron beam patterning of Ge-doped SiO{sub 2}

A focused electron beam in a scanning transmission electron microscope (STEM) is used to create arrays of core-shell structures in a specimen of amorphous SiO{sub 2} doped with Ge. The same electron microscope is then used to measure the changes that occurred in the specimen in three dimensions using electron tomography. The results show that transformations in insulators that have been subjected to intense irradiation using charged particles can be studied directly in three dimensions. The fabricated structures include core-shell nano-columns, sputtered regions, voids, and clusters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a cost effective surface-patterned transparent conductive coating as top-contact of light emitting diodes

Sol-gel process has been used to form indium zinc oxide films using an optimized combination of zinc to indium concentration in the precursor solutions. Different structures, like one (1D) and two-dimensional (2D) gratings and diffractive optical elements (DOEs) in the form of Fresnel lens are fabricated on the film surface of proposed top metal contact of LED by imprint soft lithography technique. These structures can enhance the LED's light extraction efficiency (LEE) or can shape the output beam pattern, respectively. Several characterizations are done to analyze the material and structural properties of the films. The presence of 1D and 2D gratings as well as DOEs is confirmed from field emission scanning electron and atomic force microscopes analyses. Although, X-ray diffraction shows amorphous nature of the film, but transmission electron microscopy study shows that it is nano crystalline in nature having fine particles (∼8 nm) of hexagonal ZnO. Shrinkage behaviour of gratings as a function of curing temperature is explained by Fourier transform infra-red spectra and thermo gravimetric-differential thermal analysis. The visible transmission and sheet resistance of the sample are found comparable to tin doped indium oxide (ITO). Therefore, the film can compete as low cost substitute of ITO as top metal contact of LEDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface localisation of laser photoelectron emission using Cu{sub 2}O and Ag film structures

A laser electron source localised on a photocathode surface was developed on the basis of Ag and Cu{sub 2}O thin films sequentially deposited by magnetron sputtering on a glass substrate. Photoemission of electrons under the action of the fourth (263 nm) harmonic of a femtosecond fibre laser was initiated from the surface of an Ag film deposited on the substrate surface. Photoelectron source localisation on the photocathode surface was provided by sputtering the Cu{sub 2}O copper oxide film on its surface, which significantly (about 50 times) reduced the photoemission efficiency, and by subsequent removal of the copper oxide layer in the photoemission spot with a diameter of ∼15 μm by means of focused second-harmonic radiation of a femtosecond fibre laser. In conducting research on the photocathode surface, a grid of photoemission spots was formed, which greatly facilitated the laser beam alignment with the photoemission spot. A decrease in the noises of ultrafast transmission electron microscope, associated with spatial fluctuations of the laser beam initiating pulsed photoelectron emission from the microscope photocathode when using a localised electron source on the basis of a structure of thin Cu{sub 2}O and Ag films, was experimentally demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional optical trapping and orientation of microparticles for coherent X-ray diffraction imaging

Optical trapping has been implemented in many areas of physics and biology as a noncontact sample manipulation technique to study the structure and dynamics of nano-andmesoscale objects. It provides a unique approach for manipulating microscopic objects without inducing undesired changes in structure. Combining optical trapping with hard X-ray microscopy techniques, such as coherent diffraction imaging and crystallography, provides a nonperturbing environment where electronic and structural dynamics of an individual particle in solution can be followed in situ. It was previously shown that optical trapping allows the manipulation of micrometer-sized objects for Xray fluorescence imaging. However, questions remain over the ability of optical trapping to position objects for X-ray diffraction measurements, which have stringent requirements for angular stability. Our work demonstrates that dynamic holographic optical tweezers are capable of manipulating single micrometer-scale anisotropic particles in a microfluidic environment with the precision and stability required for X-ray Bragg diffraction experiments-thus functioning as an "optical goniometer." The methodology can be extended to a variety of X-ray experiments and the Bragg coherent diffractive imaging of individual particles in solution, as demonstrated here, will be markedly enhanced with the advent of brighter, coherent X-ray sources.

Gao, Yuan↗

HRTEM low dose: the unfold of the morphed graphene, from amorphous carbon to morphed graphenes

We present experimental evidence under low-dose conditions transmission electron microscopy for the unfolding of the evolving changes in carbon soot during mechanical milling. The milled soot shows evolving changes as a function of the milling severity or time. Those changes are responsible for the transformation from amorphous carbon to graphenes, graphitic carbon, and highly ordered structures such as morphed graphenes, namely Rh6 and Rh6-II. The morphed graphenes are corrugated layers of carbon with cross-linked covalently nature and sp2 - or sp3 -type allotropes. Electron microscopy and numerical simulations are excellent complementary tools to identify those phases. Furthermore, the TEAM 05 microscope is an outstanding tool to resolve the microstructure and prevent any damage to the sample. Other characterization techniques such as XRD, Raman, and XPS fade to convey a true identification of those phases because the samples are usually blends or mixes of the mentioned phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗