Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Triple-frequency radar retrieval of microphysical properties of snow

Abstract. An algorithm based on triple-frequency (X, Ka, W) radar measurements that retrieves the size, water content and degree of riming of ice clouds is presented. This study exploits the potential of multi-frequency radar measurements to provide information on bulk snow density that should underpin better estimates of the snow characteristic size and content within the radar volume. The algorithm is based on Bayes' rule with riming parameterised by the “fill-in” model. The radar reflectivities are simulated with a range of scattering models corresponding to realistic snowflake shapes. The algorithm is tested on multi-frequency radar data collected during the ESA-funded Radar Snow Experiment For Future Precipitation Mission. During this campaign, in situ microphysical probes were mounted on the same aeroplane as the radars. This nearly perfectly co-located dataset of the remote and in situ measurements gives an opportunity to derive a combined multi-instrument estimate of snow microphysical properties that is used for a rigorous validation of the radar retrieval. Results suggest that the triple-frequency retrieval performs well in estimating ice water content (IWC) and mean mass-weighted diameters obtaining root-mean-square errors of 0.13 and 0.15, respectively, for log 10IWC and log 10Dm. The retrieval of the degree of riming is more challenging, and only the algorithm that uses Doppler information obtains results that are highly correlated with the in situ data.

54 ENVIRONMENTAL SCIENCES↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GAMPix: a novel fine-grained, low-noise and ultra-low power pixelated charge readout for TPCs

Here, we report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize the use of liquid argon time projection chamber technology for gamma ray astrophysics, for which a fine grained low power charge readout is essential. GAMPix uses a new architecture with coarse and fine scale instrumented electrodes to solve the twin problems of loss of measured charge after diffusion, and high readout power. Fundamentally, it enables low noise and ultra low power charge readout at the spatial scale limited by diffusion in a time projection chamber, and has other possibly applications, including future DUNE modules.

Shutt, Tom↗

Photochemistry sample sticks for inelastic neutron scattering

Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. Furthermore, these new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The NOvA Test Beam Program

NOvA is a long-baseline off-axis beam neutrino experiment at Fermilab and Ash River, Minnesota. By measuring νμ \nu_\mu disappearance and νe \nu_e appearance at the 14 kiloton NOvA Far Detector, the experiment is addressing outstanding questions in neutrino physics, including the neutrino mass hierarchy and existence of leptonic CP violation. The NOvA Test Beam program, under deployment at the Fermilab Test Beam Facility, will use a scaled-down NOvA detector to sample beams of tagged electrons, muons, pions, and protons in the momentum range of 0.3 to 2 GeV/c. It will further the NOvA physics reach by precisely measuring the detector's muon energy scale and electromagnetic and hadronic response, and provide real data for detailed studies of particle identification techniques. Ongoing efforts on beamline instrumentation, data acquisition, simulation, momentum reconstruction and particle identification are presented. Implications for the neutrino oscillation measurements are discussed.

Huang, Junting [Texas U.]↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NGEE Arctic, Canopy Spectral Reflectance, Utqiagvik (Barrow), Alaska, 2014-2016

Measurements of full-spectrum (i.e. 350-2500 nm) canopy spectral reflectance of Arctic plant species within the BEO, Barrow, Alaska. Spectra were collected using Spectra Vista Corporation (SVC) HR-2014i and Spectral Evolution (SE) PSR+ instruments mounted on a tripod or monopod together with a Spectralon white plate to calibrate each measurement under variable illumination conditions. Data were collected in Utqiagvik (Barrow), Alaska during the 2014 to 2016 period. Data package includes processed spectra (*.csv) files and original instrument output and processing files (*.zip).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 10-year research effort (2012-2022) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Fission TPC cross section ratio results [Abstract]

The fission TPC was designed for precision fission cross section ratio measurements. The high-fidelity 3D particle tracking data is used to conduct a detailed analysis of the uncertainty contributions. In this contribution a brief overview of the instrument was presented. The results of the 238 U(n,f)/ 235 U(n,f) cross section ratio measurement published in [Phys. Rev C 97, 034618 (2018)] were reviewed and the preliminary status of the 239 Pu(n,f)/ 235 U(n,f) cross section ratio measurement was shown.

238U(n,f)/235U(n,f) cross section ratio↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]↗

Implications of Aerosol Physicochemical Properties Including Ice Nucleation at ARM Mega Sites for Improved Understanding of Microphysical Atmospheric Cloud Processes (Final Technical Report)

Continuous, long-term measurements of atmospheric ice-nucleating particles (INPs) that influence clouds and precipitation were conducted to investigate the abundance and variability of ground-level INPs across the world. Three field campaigns were organized by the DOE Atmospheric Radiation Measurement (ARM) program, including Examining INP from Southern Great Plains (ExINP-SGP, 2019), Examining INP from Eastern North Atlantic (ExINP-ENA, 2020 – 2021), and Examining INP from North Slope of Alaska (ExINP-NSA, 2021 – 2024). Additional small-scale supporting field experiments were performed in 2019 and 2021 to collect airborne particulate matter at SGP for complementary laboratory characterization of the particles’ physical and chemical properties [Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY), 2019; ExINP-SGP II, 2021]. In these studies, the PI’s team measured INP concentration with both real-time and laboratory measurements in a wide range of freezing temperatures ($T$ from 0 °C to about –30 °C). This project elucidated spatial variability and seasonality in the abundance of immersion mode active INPs across three ARM sites using a single instrument, a Portable Ice Nucleation Experiment (PINE) chamber version 03 (PINE-03 hereafter). Collocated aerosol and meteorological data were analyzed to assess the correlation between ambient INP abundance, air mass origin region, and meteorological variability. Our findings suggest very high freezing efficiency of INPs at the NSA site across the measured temperatures (ice nucleation active surface site density, $n_s(T)$, $\approx 2 \times 10^{8} - 10^{10}$ m -2 for from –16 to –31 °C), which is a factor of 10 – 1000 times greater efficiency as compared to that found in the previous mid-latitude INP measurements in autumn using the same instrument; surprisingly high INP abundance ($\ge 1 \text{ L}^{-1}$ at –25 °C) for the examined temperatures throughout the year that PINE-03 did not measure at other sites; and high INP concentration in spring, possibly related to arctic haze episodes.

58 GEOSCIENCES↗

Density measurements for the National Ignition Facility (NIF) opacity platform

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. Here, we present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.

47 OTHER INSTRUMENTATION↗