Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Advances in laser technology for the atmospheric sciences; Proceedings of the Seminar, San Diego, Calif., August 25, 26, 1977

These papers deal with recent research, developments, and applications in laser and electrooptics technology, particularly with regard to atmospheric effects in imaging and propagation, laser instrumentation and measurements, and particle measurement. Specific topics include advanced imaging techniques, image resolution through atmospheric turbulence over the ocean, an efficient method for calculating transmittance profiles, a comparison of a corner-cube reflector and a plane mirror in folded-path and direct transmission through atmospheric turbulence, line-spread instrumentation for propagation measurements, scaling laws for thermal fluctuations in the layer adjacent to ocean waves, particle sizing by laser photography, and an optical Fourier transform analysis of satellite cloud imagery. Other papers discuss a subnanosecond photomultiplier tube for laser application, holography of solid propellant combustion, diagnostics of turbulence by holography, a camera for in situ photography of cloud particles from a hail research aircraft, and field testing of a long-path laser transmissometer designed for atmospheric visibility measurements.

Trolinger, J. D.↗

The Earth Radiation Budget Experiment nonscanner instrument

Two Earth Radiation Budget Experiment (ERBE) nonscanner instruments are flying with companion scanner instruments to measure the earth's energy budget from low earth orbit. A third set of instruments will be launched in March 1986. This program is the first designed to make a comprehensive set of highly accurate measurements of the earth's energy budget on the spectral, spatial, and temporal scales specified by the scientific community for use in climatological research. The ERBE nonscanner combines the use of the highly accurate active cavity radiometer (ACR) detector with a comprehensive preflight calibration and characterization program and a design which includes operational flexibility and in-flight calibration checks to achieve and maintain, throughout its 2-year design life, a measurement accuracy capability not previously possible. This paper describes the ERBE nonscanner instrument, its operation, calibration, and mission profile.

Luther, M. R.↗

Liquid-Crystal Point-Diffraction Interferometer for Wave-Front Measurements

A new instrument, the liquid-crystal point-diffraction interferometer (LCPDI), is developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point-diffraction interferometer and adds to it a phase-stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave fronts with very high data density and with automated data reduction. We describe the theory and design of the LCPDI. A focus shift was measured with the LCPDI, and the results are compared with theoretical results,

Mercer, Carolyn R.↗

Optical Instrumentation for Temperature and Velocity Measurements in Rig Turbines

Non-intrusive optical measurement techniques have been examined in the context of developing robust instruments which can routinely yield data of engineering utility in high speed turbomachinery test rigs. The engineering requirements of such a measurement are presented. Of particular interest were approaches that provide both velocity and state-variable information in order to be able to completely characterize transonic flowfields. Consideration of all of the requirements lead to the selection of particle image velocimetry (PIV) for the approach to velocity measurement while laser induced fluorescence of oxygen (O2 LIF) appeared to offer the most promise for gas temperature measurement. A PIV system was developed and demonstrated on a transonic turbine stage in the MIT blowdown turbine facility. A comprehensive data set has been taken at one flow condition. Extensive calibration established the absolute accuracy of the velocity measurements to be 3-5 %. The O2 LIF proved less successful. Although accurate for low speed flows, vibrational freezing of O2 prevented useful measurements in the transonic, 300-600 K operating range of interest here.

Ceyhan, I.↗

Subsatellite measurements of plasma and energetic particles

The Apollo 16 particles and fields subsatellite is instrumented to measure (1) plasma and energetic-particle fluxes, (2) vector magnetic fields, and (3) velocity of the subsatellite to a high precision for the purpose of determining lunar gravitational anomalies. Results from the magnetic-field and gravitational-field experiments are discussed. The results obtained from the plasma and energetic-particle detectors are discussed briefly. The plasma and energetic-particles experiment describes the various plasma regimes in which the moon moves, and determines how the moon interacts with the plasma and magnetic fields in the environment.

Anderson, K. A.↗

Derivation of Cumulus Cloud Dimensions and Shape from the Airborne Measurements by the Research Scanning Polarimeter

The Research Scanning Polarimeter (RSP) is an airborne instrument, whose measurements have been extensively used for retrievals of microphysical properties of clouds. In this study we show that for cumulus clouds the information content of the RSP data can be extended by adding the macroscopic parameters of the cloud, such as its geometric shape, dimensions, and height above the ground. This extension is possible by virtue of the high angular resolution and high frequency of the RSP measurements, which allow for geometric constraint of the cloud's 2D cross section between a number of tangent lines of view. The retrieval method is tested on realistic 3D radiative transfer simulations and applied to actual RSP data.

Remote sensing↗

2.3.3.404 - National Lab and University Collaboration for MHK Instrumentation and Data Processing Tools

Field and laboratory validation, testing, demonstration, and operation are critical steps for increasing the technology readiness level of marine energy (ME) converters because they provide high-quality testing and performance data that are critical information used to feed all aspects of technology development. This project, in partnership with industry, enables the marine and hydrokinetic energy (MHK) community to reliably and efficiently collect, process, manage, and share quality data by facilitating access to and development of instrumentation, guidelines and data processing/QA tools. Under this project, open-source data processing code (MHKiT) and tools (ME Data Pipeline, MRE Code Hub, PRIMRE Code Catalog), instrumentation (loads measurements), data acquisition systems (miniDAQ), and measurement guidance tools (Telesto, high EMI guidance) were developed to facilitate the collection and processing of quality laboratory and field data. Overall, this project is intended to improve the quality of the data collected during laboratory and field demonstration projects by standardizing the collection and processing techniques, as well as by improving access to instrumentation, code, and measurement guidance. Quality data will, in turn, lead to improved knowledge capture following ME device testing.

data processing↗

Evaluation of an electro-optic remote displacement measuring system

An instrumentation system to provide a noncontact method for measurement of target positions was evaluated. The system employs two electro-optic camera units which give stereo information for use in determining three dimensional target locations. Specially developed, infrared sensitive photodetectors are used in the cameras to sense radiation from light emitting diode targets. Up to 30 of these targets can be monitored with a sampling rate of 312 Hz per target. An important part of the system is a minicomputer which is used to collect the camera data, sort it, make corrections for distortions in the electro-optic system, and perform the necesssary coordinate transformations. If target motions are restricted to locations in a plane which is perpendicular to a camera's optical axis, the system can be used with just one camera. Calibrations performed in this mode characterize accuracies in single camera operation. This information is also useful in determination of single camera contributions to total system errors. For this reason the system was tested in both the single camera and two camera (stereo) modes of operation.

Monteith, J. H.↗

A preliminary assessment of the problems in the use of interference filter photometers to determine total ozone

In the spring of 1979 an investigation was started involving the intercomparison of five ground based instruments designed to measure total ozone. The instruments considered include the Dobson spectrometer, the Russian M-83 ozonometer, the Brewer Ozone Spectrophotometer, the New Zealand (Canterbury) filter photometer, and the SenTran Company filter photometer. Three of these instruments use optical filters to make spectrophotometric determinations of total atmospheric ozone. The M-83 uses glass absorption filters to isolate the ultraviolet bands used. The Canterbury and the SenTran instruments use narrow-bandpass dielectric interference filters for the same purpose. Instruments employing optical filters are very appealing since they can be made small, rugged, and relatively inexpensive. However, the results of the reported investigation show that serious problems must be resolved before any filter instrument can be considered reliable enough for the conduction of long term, meaningful ozone measurements.

Gerlach, J. C.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗

Third-generation FAGE instrument for tropospheric hydroxyl radical measurement

A single-stage, frequency-doubled, copper vapor laser-pumped dye laser has been constructed to be used in the measurement of atmospheric hydroxyl radical concentrations. A new photon counting instrument is used for HO fluorescence detection. Theoretical and experimental studies of instrument performance show better sensitivities and reduced photolytic interferences than have been possible with previous systems based upon Nd:YAG pumping.

Chan, C. Y.↗

Microgravity Environment Description Handbook

The Microgravity Measurement and Analysis Project (MMAP) at the NASA Lewis Research Center (LeRC) manages the Space Acceleration Measurement System (SAMS) and the Orbital Acceleration Research Experiment (OARE) instruments to measure the microgravity environment on orbiting space laboratories. These laboratories include the Spacelab payloads on the shuttle, the SPACEHAB module on the shuttle, the middeck area of the shuttle, and Russia's Mir space station. Experiments are performed in these laboratories to investigate scientific principles in the near-absence of gravity. The microgravity environment desired for most experiments would have zero acceleration across all frequency bands or a true weightless condition. This is not possible due to the nature of spaceflight where there are numerous factors which introduce accelerations to the environment. This handbook presents an overview of the major microgravity environment disturbances of these laboratories. These disturbances are characterized by their source (where known), their magnitude, frequency and duration, and their effect on the microgravity environment. Each disturbance is characterized on a single page for ease in understanding the effect of a particular disturbance. The handbook also contains a brief description of each laboratory.

DeLombard, Richard↗

The Magnetospheric Multiscale Mission...Resolving Fundamental Processes in Space Plasmas

The Magnetospheric Multiscale (MMS) mission is a multiple-spacecraft Solar-Terrestrial Probe designed to study the microphysics of magnetic reconnection, charged particle acceleration, and turbulence in key boundary regions of Earth's magnetosphere. These three processes, which control the flow of energy, mass, and momentum within and across plasma boundaries, occur throughout the universe and are fundamental to our understanding of astrophysical and solar system plasmas. Only in Earth's magnetosphere, however, are they readily accessible for sustained study through in-situ measurement. MMS will employ five co-orbiting spacecraft identically instrumented to measure electric and magnetic fields, plasmas, and energetic particles. The initial parameters of the individual spacecraft orbits will be designed so that the spacecraft formation will evolve into a three-dimensional configuration near apogee, allowing MMS to differentiate between spatial and temporal effects and to determine the three dimensional geometry of plasma, field, and current structures. In order to sample all of the magnetospheric boundary regions, MMS will employ a unique four-phase orbital strategy involving carefully sequenced changes in the local time and radial distance of apogee and, in the third phase, a change in orbit inclination from 10 degrees to 90 degrees. The nominal mission operational lifetime is two years. Launch is currently scheduled for 2006.

Curtis, S.↗

Profiling of Atmospheric Water Vapor with MIR and LASE

This paper presents the first and the only simultaneous measurements of water vapor by MIR (Millimeter-wave Imaging Radiometer) and LASE (Lidar Atmospheric Sounding Experiment) on board the same ER-2 aircraft. Water vapor is one of the most important constituents in the Earth's atmosphere, as its spatial and temporal variations affect a wide spectrum of meteorological phenomena ranging from the formation of clouds to the development of severe storms. Its concentration, as measured in terms of relative humidity, determines the extinction coefficient of atmospheric aerosol particles and therefore visibility. These considerations point to the need for effective and frequent measurements of the atmospheric water vapor. The MIR and LASE instruments provide measurements of water vapor profiles with two markedly different techniques. LASE can give water vapor profiles with excellent vertical resolution under clear condition, while MIR can retrieve water vapor profiles with a crude vertical resolution even under a moderate cloud cover. Additionally, millimeter-wave measurements are relatively simple and provide better spatial coverage.

Wang, J. R.↗

Science Results From The ARCADE Open-Aperture Cryogenic Balloon Payload

The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) is a balloon-borne instrument to measure the frequency spectrum of the cosmic microwave background and diffuse Galactic foregrounds at centimeter wavelengths. ARCADE greatly reduces measurement uncertainties compared to previous balloon-borne or ground-based instrument using a double-nulled design that features fully cryogenic optics with no windows between the atmosphere and the 2.7 K instrument. A four-hour flight in 2006 achieved sensitivity comparable to the COBE/FIRAS satellite measurement while providing new insights for emission ranging from spinning dust in the interstellar medium to an unexpectedly bright extragalactic radio background. I will discuss scientific results from the ARCADE program and implications of the ARCADE cold optics for millimeter and sub-mm astronomy.

Kogut, Alan J.↗