Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Measurement of the W-boson mass and width with the ATLAS detector using proton–proton collisions at $\sqrt{s}=7$ TeV

Proton-proton collision data recorded by the ATLAS detector in 2011, at a centre-of-mass energy of 7 TeV, have been used for an improved determination of the W-boson mass and a first measurement of the W-boson width at the LHC. Recent fits to the proton parton distribution functions are incorporated in the measurement procedure and an improved statistical method is used to increase the measurement precision. The measurement of the W-boson mass yields a value of m w = 80,366.5 ± 9.8 (stat.) ± 12.5 (syst.) MeV = 80,366.5 ± 15.9 MeV, and the width is measured as Γ w = 2202 ± 32 (stat.) ± 34 (syst.) MeV = 2202 ± 47 MeV. The first uncertainty components are statistical and the second correspond to the experimental and physics-modelling systematic uncertainties. Both results are consistent with the expectation from fits to electroweak precision data. The present measurement of m w is compatible with and supersedes the previous measurement performed using the same data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Linear Point Standard Ruler with DESI DR1 and DR2 Data

The linear point, a purely geometric feature in the monopole of the two-point correlation function, has been proposed as an alternative standard ruler. Compared to the peak in the correlation function, it is more robust to late-time nonlinear effects at the percent level. In light of improved simulations and high quality data, we revisit the robustness of the linear point and use it as an alternative to template-based fitting approaches typically used in BAO analyses. We present the linear point measurements on galaxy samples from the first and second data releases (DR1 and DR2) of the DESI survey. We convert the linear point into a dimensionless parameter $α_{iso,LP}$, defined as the ratio of the linear point in the fiducial cosmology and the observed value, analogous to the isotropic BAO scaling parameter $α_{iso}$ used in previous BAO measurements. Using the 2nd generation of AbacusSummit mock catalogs, we find that linear point measurements are more precise when calculated in the post-reconstruction regime with 15-60% smaller uncertainties than those pre-reconstruction. We find a systematic shift in the linear point measurements compared against the isotropic BAO measurements in mocks; we attribute this to the isotropic damping parameter responsible for smearing the linear point in the nonlinear regime. We propose a sample-dependent correction that mitigates the impact of late-time nonlinear effects. While this introduces a cosmology dependence in an otherwise model-independent measurement, this is necessary given the sub-percent precision dictated by current cosmological surveys. Comparing $α_{iso,LP}$ with isotropic BAO measurements made on the DESI DR1 and DR2 galaxy samples, we find excellent agreement after applying this correction, particularly post-reconstruction. We discuss future scope regarding cosmological inference with linear point measurements.

Uberoi, N. [Yale U.] (ORCID:0000000275179629)↗

Measurement of the $B_s^0 → μμ$ effective lifetime with the ATLAS detector

This paper reports the first ATLAS measurement of the $B_s^0 → μμ$ effective lifetime. The measurement is based on the data collected in 2015–2016, amounting to 26.3 fb -1 of 13 TeV LHC proton-proton collisions. The proper decay-time distribution of 58 ± 13 background-subtracted signal candidates is fit with simulated signal templates parameterised as a function of the $B_s^0$ effective lifetime, with statistical uncertainties extracted through a Neyman construction. The resulting effective measurement of the $B_s^0 → μμ$ lifetime is 0.99$^{+0.42}_{-0.07}$ (stat.) ± 0.17 (syst.) ps and it is found to be consistent with the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Pantheon+ Analysis: Cosmological Constraints

We present constraints on cosmological parameters from the Pantheon+ analysis of 1701 light curves of 1550 distinct Type Ia supernovae (SNe Ia) ranging in redshift from z = 0.001 to 2.26. This work features an increased sample size from the addition of multiple cross-calibrated photometric systems of SNe covering an increased redshift span, and improved treatments of systematic uncertainties in comparison to the original Pantheon analysis, which together result in a factor of 2 improvement in cosmological constraining power. For a flat ΛCDM model, we find Ω M = 0.334 ± 0.018 from SNe Ia alone. For a flat w 0 CDM model, we measure w 0 = –0.90 ± 0.14 from SNe Ia alone, H 0 = 73.5 ± 1.1 km s –1 Mpc –1 when including the Cepheid host distances and covariance (SH0ES), and w 0 = $-{0.978}_{-0.031}^{+0.024}$ when combining the SN likelihood with Planck constraints from the cosmic microwave background (CMB) and baryon acoustic oscillations (BAO); both w 0 values are consistent with a cosmological constant. We also present the most precise measurements to date on the evolution of dark energy in a flat w 0 w a CDM universe, and measure w a = $-{0.1}_{-2.0}^{+0.9}$ from Pantheon+ SNe Ia alone, H 0 = 73.3 ± 1.1 km s –1 Mpc –1 when including SH0ES Cepheid distances, and w a = $-{0.65}_{-0.32}^{+0.28}$ when combining Pantheon+ SNe Ia with CMB and BAO data. Finally, we find that systematic uncertainties in the use of SNe Ia along the distance ladder comprise less than one-third of the total uncertainty in the measurement of H 0 and cannot explain the present "Hubble tension" between local measurements and early universe predictions from the cosmological model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Current Status of Radiopharmaceutical Therapy

In radiopharmaceutical therapy (RPT), a radionuclide is systemically or locally delivered with the goal of targeting and delivering radiation to cancer cells while minimizing radiation exposure to untargeted cells. Examples of current RPTs include thyroid ablation with the administration of {sup 131}I, treatment of liver cancer with {sup 90}Y microspheres, the treatment of bony metastases with {sup 223}Ra, and the treatment of neuroendocrine tumors with {sup 177}Lu-DOTATATE. New RPTs are being developed where radionuclides are incorporated into systemic targeted therapies. To assure that RPT is appropriately implemented, advances in targeting need to be matched with advances in quantitative imaging and dosimetry methods. Currently, radiopharmaceutical therapy is administered by intravenous or locoregional injection, and the treatment planning has typically been implemented like chemotherapy, where the activity administered is either fixed or based on a patient’s body weight or body surface area. RPT pharmacokinetics are measurable by quantitative imaging and are known to vary across patients, both in tumors and normal tissues. Therefore, fixed or weight-based activity prescriptions are not currently optimized to deliver a cytotoxic dose to targets while remaining within the tolerance dose of organs at risk. Methods that provide dose estimates to individual patients rather than to reference geometries are needed to assess and adjust the injected RPT dose. Accurate doses to targets and organs at risk will benefit the individual patients and decrease uncertainties in clinical trials. Imaging can be used to measure activity distribution in vivo, and this information can be used to determine patient-specific treatment plans where the dose to the targets and organs at risk can be calculated. The development and adoption of imaging-based dosimetry methods is particularly beneficial in early clinical trials. In this work we discuss dosimetric accuracy needs in modern radiation oncology, uncertainties in the dosimetry in RPT, and best approaches for imaging and dosimetry of internal radionuclide therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in X-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard X-ray TESs to measure the absolute energies of muonic-argon (R-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. Here, we achieved similar to 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Assessing boundary condition and parametric uncertainty in numerical-weather-prediction-modeled, long-term offshore wind speed through machine learning and analog ensemble

To accurately plan and manage wind power plants, not only does the time-varying wind resource at the site of interest need to be assessed but also the uncertainty connected to this estimate. Numerical weather prediction (NWP) models at the mesoscale represent a valuable way to characterize the wind resource offshore, given the challenges connected with measuring hub-height wind speed. The boundary condition and parametric uncertainty associated with modeled wind speed is often estimated by running a model ensemble. However, creating an NWP ensemble of long-term wind resource data over a large region represents a computational challenge. Here, we propose two approaches to temporally extrapolate wind speed boundary condition and parametric uncertainty using a more convenient setup in which a mesoscale ensemble is run over a short-term period (1 year), and only a single model covers the desired long-term period (20 year). We quantify hub-height wind speed boundary condition and parametric uncertainty from the short-term model ensemble as its normalized across-ensemble standard deviation. Then, we develop and apply a gradient-boosting model and an analog ensemble approach to temporally extrapolate such uncertainty to the full 20-year period, for which only a single model run is available. As a test case, we consider offshore wind resource characterization in the California Outer Continental Shelf. Both of the proposed approaches provide accurate estimates of the long-term wind speed boundary condition and parametric uncertainty across the region (R 2 >0.75), with the gradient-boosting model slightly outperforming the analog ensemble in terms of bias and centered root-mean-square error. At the three offshore wind energy lease areas in the region, we find a long-term median hourly uncertainty between 10 % and 14 % of the mean hub-height wind speed values. Finally, we assess the physical variability in the uncertainty estimates. In general, we find that the wind speed uncertainty increases closer to land. Also, neutral conditions have smaller uncertainty than the stable and unstable cases, and the modeled wind speed in winter has less boundary condition and parametric sensitivity than summer.

17 WIND ENERGY↗

133Xe Noble Gas Mass Spectrometry Measurement for High Purity Germanium Detector Performance Verification

Idaho National Laboratory produces quality control standards for laboratories that operate xenon radionuclide monitoring systems. Activities reported with each quality control standard are quantified using high purity germanium detectors. A collection of measurement capabilities are being set up at Idaho National Laboratory to establish an in-house high purity germanium detector performance verification system, with noble gas mass spectrometry being one of these measurement capabilities. The first noble gas mass spectrometry and high purity germanium measurement comparison is presented here. A Xe-133 gas sample was prepared and the activity was quantified with high purity germanium detectors. The Xe-133 sample was diluted with a known quantity of isotopically enriched Xe-126 gas; the resulting Xe-133 : Xe-126 atom ratio was calculated to be 1.15x10-4 +/- 2% at reference time t. An aliquot of this gas sample containing approximately 10 million Xe-133 atoms was introduced into a ThermoFisher Scientific Helix MC Plus noble gas mass spectrometer for analysis. The measured Xe-133 : Xe-126 atom ratio was determined to be 1.10x10-4 +/- 2% (1-sigma uncertainty) at reference time t, about 4.3% lower than the atom ratio determined with the measured high purity germanium activity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A measurement of the K + → π + μ + μ – decay

A sample of 2.8 × 10 4 K + → π + μ + μ – candidates with negligible background was collected by the NA62 experiment at the CERN SPS in 2017–2018. The model-independent branching fraction is measured to be (9.15 ± 0.08) × 10 –8 , a factor three more precise than previous measurements. The decay form factor is presented as a function of the squared dimuon mass. A measurement of the form factor parameters and their uncertainties is performed using a description based on Chiral Perturbation Theory at O(p 6 ).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid-Phase Effects on Adsorption Processes in Heterogeneous Catalysis

Aqueous solvation free energies of adsorption have recently been measured for phenol adsorption on Pt(111). Endergonic solvent effects of ~1 eV suggest solvents dramatically influence a metal catalyst’s activity with significant implications for the catalyst design. However, measurements are indirect and involve adsorption isotherm models, which potentially reduces the reliability of the extracted energy values. Computational, implicit solvation models predict exergonic solvation effects for phenol adsorption, failing to agree with measurements even qualitatively. In this study, an explicit, hybrid quantum mechanical/molecular mechanical approach for computing solvation free energies of adsorption is developed, solvation free energies of phenol adsorption are computed, and experimental data for solvation free energies of phenol adsorption are reanalyzed using multiple adsorption isotherm models. Explicit solvation calculations predict an endergonic solvation free energy for phenol adsorption that agrees well with measurements to within the experimental and force field uncertainties. Computed adsorption free energies of solvation of carbon monoxide, ethylene glycol, benzene, and phenol over the (111) facet of Pt and Cu suggest that liquid water destabilizes all adsorbed species, with the largest impact on the largest adsorbates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifiability and predictability of integer- and fractional-order epidemiological models using physics-informed neural networks

Here we analyze a plurality of epidemiological models through the lens of physics-informed neural networks (PINNs) that enable us to identify time-dependent parameters and data-driven fractional differential operators. In particular, we consider several variations of the classical susceptible-infectious-removed (SIR) model by introducing more compartments and fractional-order and time-delay models. We report the results for the spread of COVID-19 in New York City, Rhode Island and Michigan states and Italy, by simultaneously inferring the unknown parameters and the unobserved dynamics. For integer-order and time-delay models, we fit the available data by identifying time-dependent parameters, which are represented by neural networks. In contrast, for fractional differential models, we fit the data by determining different time-dependent derivative orders for each compartment, which we represent by neural networks. We investigate the structural and practical identifiability of these unknown functions for different datasets, and quantify the uncertainty associated with neural networks and with control measures in forecasting the pandemic.

60 APPLIED LIFE SCIENCES↗

Planck 2018 results XI. Polarized dust foregrounds

The study of polarized dust emission has become entwined with the analysis of the cosmic microwave background (CMB) polarization in the quest for the curl-like B-mode polarization from primordial gravitational waves and the low-multipole E-mode polarization associated with the reionization of the Universe. We used the new Planck PR3 maps to characterize Galactic dust emission at high latitudes as a foreground to the CMB polarization and use end-to-end simulations to compute uncertainties and assess the statistical significance of our measurements. We present Planck EE, BB, and TE power spectra of dust polarization at 353 GHz for a set of six nested high-Galactic-latitude sky regions covering from 24 to 71% of the sky. We present power-law fits to the angular power spectra, yielding evidence for statistically significant variations of the exponents over sky regions and a difference between the values for the EE and BB spectra, which for the largest sky region are α EE = -2.42 ± 0.02 and α BB = -2.54 ± 0.02, respectively. The spectra show that the TE correlation and E/B power asymmetry discovered by Planck extend to low multipoles that were not included in earlier Planck polarization papers due to residual data systematics. We also report evidence for a positive TB dust signal. Combining data from Planck and WMAP, we have determined the amplitudes and spectral energy distributions (SEDs) of polarized foregrounds, including the correlation between dust and synchrotron polarized emission, for the six sky regions as a function of multipole. This quantifies the challenge of the component-separation procedure that is required for measuring the low-ℓ reionization CMB E-mode signal and detecting the reionization and recombination peaks of primordial CMB B modes. The SED of polarized dust emission is fit well by a single-temperature modified black-body emission law from 353 GHz to below 70 GHz. For a dust temperature of 19.6 K, the mean dust spectral index for dust polarization is β d P = 1.53±0.02. The difference between indices for polarization and total intensity is β d P -β d I = 0.05±0.03. By fitting multi-frequency cross-spectra between Planck data at 100, 143, 217, and 353 GHz, we examine the correlation of the dust polarization maps across frequency. We find no evidence for a loss of correlation and provide lower limits to the correlation ratio that are tighter than values we derive from the correlation of the 217- and 353 GHz maps alone. If the Planck limit on decorrelation for the largest sky region applies to the smaller sky regions observed by sub-orbital experiments, then frequency decorrelation of dust polarization might not be a problem for CMB experiments aiming at a primordial B-mode detection limit on the tensor-to-scalar ratio r ≃ 0.01 at the recombination peak. However, the Planck sensitivity precludes identifying how difficult the component-separation problem will be for more ambitious experiments targeting lower limits on r.

79 ASTRONOMY AND ASTROPHYSICS↗

Faraday-effect polarimetry for current profile measurement in the tokamak plasma edge

Toroidal current profile measurements in the tokamak plasma edge are critical for fusion plasma physics research and model validation. A three-wave Faraday-effect polarimeter-interferometer with a sub-centimeter spatial resolution is proposed on the DIII-D tokamak to determine the edge current profile via Abel inversion. By using probe beams with 316 µm wavelength, a low-field-side, vertical-view, single-pass optical layout covering the plasma edge region (R = 2.15–2.27 m) is assessed. Measurements with no greater than 0.1° polarimetric systematic uncertainty, no greater than 0.01° polarimetric root-mean-square noise (1 kHz bandwidth), and a 0.8 cm radial chord spacing are considered feasible based on the achieved performance of existing systems using similar wavelengths on fusion devices. Furthermore, synthetic diagnostic calculations taking various factors into account, such as diagnostic uncertainty and quality of magnetic flux surfaces, find that the edge current profile can be determined with up to 0.12 MA/m 2 uncertainty, or about 10% of the peak current density in the pedestal of an investigated high-confinement plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring dark forces with multimessenger studies of extreme mass ratio inspirals

Abstract The exploration of dark sector interactions via gravitational waves (GWs) from binary inspirals has been a subject of recent interest. We study dark forces using extreme mass ratio inspirals (EMRIs), pointing out two issues of interest. Firstly, the innermost stable circular orbit (ISCO) of the EMRI, which sets the characteristic length scale of the system and hence the dark force range to which it exhibits enhanced sensitivity, probes force mediator masses that complement those studied with supermassive black hole (SMBH) or neutron star binaries. The LISA mission (the proposedμAres detector) will probe mediators with massesm V ∼ 10 -16 eV (m V ∼ 10 -18 eV), corresponding to ISCOs of 10 6 M ⊙ (10 8 M ⊙ ) central SMBHs. Secondly, while the sensitivity to dark couplings is typically limited by the uncertainty in the binary component masses, independent mass measurements of the central SMBH through reverberation mapping campaigns or the motion of dynamical tracers enable one to break this degeneracy. Our results therefore highlight the necessity for coordinated studies, loosely referred to as “multimessenger”, between futureμHz- mHz GW observatories and ongoing and forthcoming SMBH mass measurement campaigns, including OzDES-RM, SDSS-RM, and SDSS-V Black Hole Mapper.

Astronomy & Astrophysics↗

Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility

We illustrate the absolute calibration of the continuum x-ray spectrometer (ConSpec), designed to measure the hot-spot electron temperature of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). The spectrometer measures emission from photon energies of 20 to 30 keV where opacity effects in ICF implosions at the NIF are negligible and provides spatial resolution to separate the hot-spot emission from other x-ray sources, such as the gold emission from the hohlraum wall. Using a combination of x-ray ray tracing and calibration data taken using a well characterized x-ray source, we measure the dispersion, spatial resolution, and absolute sensitivity of the instrument. Finally, we present an example spectrum measured at the NIF and demonstrate the ability to measure the hot-spot electron temperature with uncertainty under 10%.

47 OTHER INSTRUMENTATION↗

Dark Energy Survey Year 3 results: Exploiting small-scale information with lensing shear ratios

Using the first three years of data from the Dark Energy Survey (DES), we use ratios of small-scale galaxy-galaxy lensing measurements around the same lens sample to constrain source redshift uncertainties, intrinsic alignments and other systematics or nuisance parameters of our model. Instead of using a simple geometric approach for the ratios as has been done in the past, we use the full modeling of the galaxy-galaxy lensing measurements, including the corresponding integration over the power spectrum and the contributions from intrinsic alignments and lens magnification. We perform extensive testing of the small-scale shear-ratio (SR) modeling by studying the impact of different effects such as the inclusion of baryonic physics, nonlinear biasing, halo occupation distribution descriptions and lens magnification, among others, and using realistic N -body simulations of the DES data. We validate the robustness of our constraints in the data by using two independent lens samples with different galaxy properties, and by deriving constraints using the corresponding large-scale ratios for which the modeling is simpler. The results applied to the DES Y3 data demonstrate how the ratios provide significant improvements in constraining power for several nuisance parameters in our model, especially on source redshift calibration and intrinsic alignments. For source redshifts, SR improves the constraints from the prior by up to 38% in some redshift bins. Such improvements, and especially the constraints it provides on intrinsic alignments, translate to tighter cosmological constraints when shear ratios are combined with cosmic shear and other 2pt functions. In particular, for the DES Y3 data, SR improves S 8 constraints from cosmic shear by up to 31%, and for the full combination of probes ( 3 × 2 pt ) by up to 10%. The shear ratios presented in this work are used as an additional likelihood for cosmic shear, 2 × 2 pt and the full 3 × 2 pt in the fiducial DES Y3 cosmological analysis.

79 ASTRONOMY AND ASTROPHYSICS↗