Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETOMETERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Correlation Between Microstructure and In-Field Performance of Zr-Added REBCO Coated Conductors Made by Advanced MOCVD

In this paper, we present correlation features between critical current density (J c ) and microstructural characteristics of Zr-added (0, 5, and 15 mol.%) REBa 2 Cu 3 O 7-x (REBCO and RE = rare earth) coated conductors fabricated by the novel advanced metal organic chemical vapor deposition technique. The J c along the tape normal (~ B || c-axis) measured by a vibrating sample magnetometer at 30 and 65 K and magnetic flux density range of 0-14 T was used for qualitative comparison of different Zr-added REBCO tapes. It is found that tapes with enhanced in-field J c exhibit a rise of critical current (plateau or fishtail effect) at magnetic flux density 1-8 T and temperatures 65 K. The TEM microstructure analysis indicates that the plateau effect is not the intrinsic property of REBCO matrix but depends on size distribution and density of BaZrO 3 (BZO) self-assembled nanocolumns. Two types of BZO microstructures have been identified: one with uniform BZO diameter 4-7 nm, whereas some films exhibit bottle-shaped BZO nanocolumns with alternating wide and narrow sections, 7-13 and 4-6 nm, respectively. The non-uniform shape and broad size distribution of BZO nanocolumns are correlated to more vortex pinning strength and matching field.

2G high-temperature superconductor (2GHTS)↗

Correlation of In-Field Performance of Thick REBCO Films Between 0–14 T and 4.2–77 K

We present results on correlation of in-field performance of 2G-high temperature superconductor (HTS) tapes produced by an advanced metal organic chemical vapor deposition (A-MOCVD) system which enables growth of very thick films (>4 μm) without deterioration in performance with thickness. A set of 175 samples has been measured using a vibrating sample magnetometer (VSM), at temperatures ranging from 4.2 to 77 K and field from 0 to 14 T (B⊥tape). The sample set contains a wide range of characteristics, with Zr doping from 0 to 20 mol.%, film thickness from 1 to over 4 μm and a range of compositions with varying rare earth (RE) excess, as well as varying Ba/Cu stoichiometry. The set has been purposely chosen to include a very wide range of properties, with the goal of identifying common features of REBCO conductors that are independent of the listed variables. The in-field critical current density (Jc) performance has been separated into two factors, temperature dependent self-field Jc and field and temperature dependent retention factor. The results reveal very systematic trends in maximum Jc correlation with temperature and field, which can be utilized both for long length characterization and as a tool for providing insight into pinning mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting Hardware Trojans in PCBs Using Side Channel Loopbacks

Malicious modifications to printed circuit boards (PCBs) are known as hardware Trojans. These may arise when malafide third parties alter PCBs premanufacturing or postmanufacturing and are a concern in safety-critical applications, such as industrial control systems. In this research, we examine how data-driven detection can be utilized to detect such Trojans at run-time. We develop a flexible and reconfigurable PCB test bed derived from the popular open-source programmable logic controller (PLC) platform “OpenPLC.” We then develop a Trojan detection framework, which utilizes and analyzes multimodal side channels (e.g., timing, magnetic signals, power, and hardware performance counters). We consider defender-configurable input/output (I/O) loopback test, comparison with design-document baselines, and magnetometer-aided monitoring of system behavior under defender-chosen excitations. Our approach can extend to golden-free environments. Golden (known-good) versions of the PCBs are assumed not available, but design information, datasheets, and component-level data are available. We demonstrate the efficacy of our approach on a range of Trojans instantiated in the test bed.

42 ENGINEERING↗

Voltage-driven, local, and efficient excitation of nitrogen-vacancy centers in diamond

Magnetic sensing technology has found widespread application in a diverse set of industries including transportation, medicine, and resource exploration. These uses often require highly sensitive instruments to measure the extremely small magnetic fields involved, relying on difficult-to-integrate superconducting quantum interference devices and spin-exchange relaxation-free magnetometers. A potential alternative, nitrogen-vacancy (NV) centers in diamond, has shown great potential as a high-sensitivity and high-resolution magnetic sensor capable of operating in an unshielded, room-temperature environment. Transitioning NV center–based sensors into practical devices, however, is impeded by the need for high-power radio frequency (RF) excitation to manipulate them. We report an advance that combines two different physical phenomena to enable a highly efficient excitation of the NV centers: magnetoelastic drive of ferromagnetic resonance and NV-magnon coupling. Our work demonstrates a new pathway that combine acoustics and magnonics that enables highly energy-efficient and local excitation of NV centers without the need for any external RF excitation and, thus, could lead to completely integrated, on-chip, atomic sensors.

42 ENGINEERING↗

Effect of defects in the rare-earth sublattice of the Kondo insulator YbB{sub 12} on its spectral characteristics and magnetic susceptibility

The results of measuring the static and dynamic magnetic susceptibilities of several series of samples, which are based on the YbB{sub 12} Kondo insulator and are substituted in the rare-earth sublattice, are analyzed. Substitution is performed by nonmagnetic isoelectronic Lu ions; magnetic isoelectronic Tm ions; and nonisoelectronic nonmagnetic Y, Sc, and Zr ions. The static susceptibility is measured by a SQUID magnetometer in weak fields, and the dynamic susceptibility is determined from inelastic neutron scattering data. The magnetic properties are simulated using the spectral function found from neutron experimental data. A one-to-one correspondence is established between the influence of an impurity on the initial neutron spectrum and the temperature dependence of the static susceptibility. The results obtained allow one to analyze the relation between the magnetic properties and the electronic structure of the compounds of the given class.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The nEDM experiment at the SNS

The nEDM collaboration proposes to measure the neutron electric dipole moment at the Spallation Neutron Source (Oak Ridge National Laboratory). The nEDM is a clear signature of CP violation. According to the Standard Model the nEDM is very small (∼10{sup −31} e cm), but many theories predict much higher values. In the proposed experiment polarized cold neutrons from the SNS would be trapped in liquid helium at a temperature of about 400 mK. The neutron spin would precess in a very uniform magnetic field (H ∼ 30 mG), and the experiment would measure the change in the precession frequency when a very strong electric field (E ∼ 50 kV/cm) is applied. Polarized {sup 3}He atoms serve as a co-magnetometer. The goal of the experiment is to measure the nEDM with an accuracy of ∼9 × 10{sup −28} e cm, which is more than an order of magnitude better than existing results.

43 PARTICLE ACCELERATORS↗

Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

Abstract State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System

A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject’s scalp. We have conducted two MEG experiments on three subjects: assessment of somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial MEG system based on superconducting quantum interference devices (SQUIDs). We cross validated the robustness of our system by calculating the distance between the location of the equivalent current dipole (ECD) yielded by our OPM-based MEG system and the ECD location calculated by the commercial SQUID-based MEG system. We achieved sub-centimeter accuracy for both SEF and AEF responses in all three subjects. Due to the proximity (12 mm) of the OPM channels to the scalp, it is anticipated that future OPM-based MEG systems will offer enhanced spatial resolution as they will capture finer spatial features compared to traditional MEG systems employing SQUIDs.

60 APPLIED LIFE SCIENCES↗

OM300 Direction Drilling Module

OM300 – Geothermal Direction Drilling Navigation Tool: Design and produce a prototype directional drilling navigation tool capable of high temperature operation in geothermal drilling Accuracies of 0.1° Inclination and Tool Face, 0.5° Azimuth Environmental Ruggedness typical of existing oil/gas drilling Multiple Selectable Sensor Ranges High accuracy for navigation, low bandwidth High G-range & bandwidth for Stick-Slip and Chirp detection Selectable serial data communications Reduce cost of drilling in high temperature Geothermal reservoirs Innovative aspects of project Honeywell MEMS* Vibrating Beam Accelerometers (VBA) APS Flux-gate Magnetometers Honeywell Silicon-On-Insulator (SOI) High-temperature electronics Rugged High-temperature capable package and assembly process

15 GEOTHERMAL ENERGY↗

Evaluation of Anisotropic Magnetoresistive (AMR) Sensors for a Magnetic Field Scanning System for SRF Cavities

One of the significant causes of residual losses in superconducting radio-frequency (SRF) cavities is trapped magnetic flux. The flux trapping mechanism depends on many factors that include cool-down conditions, surface preparation techniques, and ambient magnetic field orientation. Suitable diagnostic tools are not yet available to quantitatively correlate such factors’ effect on the flux trapping mechanism. A magnetic field scanning system (MFSS) consisting of AMR sensors, fluxgate magnetometers, or Hall probes is recently commissioned to scan the local magnetic field of trapped vortices around 1.3 GHz single-cell SRF cavities. In this contribution, we will present results from sensitivity calibration and the first tests of AMR sensors in the MFSS.

Parajuli, I. P.↗

Simulation of the thermoelectric effect in a multi-metallic superconducting cavity

Superconducting radio-frequency accelerating cavities made with different material layers, such as copper, Nb or Nb₃Sn, are susceptible to thermoelectric effects due to differences in Seebeck coefficients between the metals. A temperature gradient across the surfaces can drive thermoelectric currents, which may impact the cavity performance. A layered Cu/Nb/Nb3Sn single-cell cavity was tested with cryocoolers in 2022. Three heaters were mounted on the cavity surface at different locations and three single-axis cryogenic fluxgate magnetometers were attached close to the cavity equator. A linear increase in the magnetic field was measured while increasing the heaters' power. The cavity setup was analyzed with COMSOL and the results showed a trend similar to that observed in the experiment. This contribution details the approach chosen for the simulation and some of the challenges encountered.

Accelerator Physics↗

Preliminary Results from Magnetic Field Scanning System for a Single-Cell Niobium Cavity

One of the building blocks of modern particle accelerators is superconducting radiofrequency (SRF) cavities. Niobium is the material of choice to build such cavities, which operate at liquid helium temperature (2 - 4 K) and have some of the highest quality factors found in Nature. There are several sources of residual losses, one of them is trapped magnetic flux, which limits the quality factor in SRF cavities. The flux trapping mechanism depends on different niobium surface preparations and cool-down conditions. Suitable diagnostic tools are not yet available to study the effects of such conditions on magnetic flux trapping. A magnetic field scanning system (MFSS) for SRF cavities using Hall probes and Fluxgate magnetometer has been designed, built, and is commissioned to measure the local magnetic field trapped in 1.3 GHz single-cell SRF cavities at 4 K. In this contribution, we will present the preliminary results from MFSS for a single cell niobium cavity.

Ciovati, G.↗

QUENCH DETECTION IN A SUPERCONDUCTING RADIO FREQUENCY CAVITY WITH COMBINED TEMPERATURE AND MAGNETIC FIELD MAPPING

Local dissipation of RF power in superconducting radio frequency cavities create so called "hot-spots", primary precursors of cavity quench driven by either thermal or magnetic instability. These hot-spots are detected by a temperature mapping system, and a large increase in temperature on the outer surface is detected during cavity quench events. Here, we have used combined magnetic and temperature mapping systems using anisotropic magneto-resistance (AMR) sensors and carbon resisters to locate the hot spots and areas with high trapped flux on a 3.0 GHz single-cell Nb cavity during the RF tests at 2.0 K. The quench location and hot spots were detected near the equator when the residual magnetic field in the Dewar is kept < 1 mG. The hot spots and quench locations moved when the magnetic field is trapped locally, as detected by T-mapping system. No significant dynamics of trapped flux is detected by AMR sensors, however change in magnetic flux during cavity quench is detected by a flux gate magnetometer, close to the quench location. The result provide the direct evidence of hot spots and quench events due to localized trapped vortices.

Ciovati, Gianluigi↗

Multifunctional Integrated Sensors (MFISES)

Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and the real world applications of the sensors systems.

42 ENGINEERING↗

The MCDB System for Management and Analysis of Petabyte-Scale Uncertain Data

Analysts working with very large data sets often use statistical models to “guess” at unknown, inaccurate, or missing information associated with the data. For example, a distant object viewed through an optical lens will have its position slightly shifted by imperfections in the lens. Thus, rather than considering the object’s observed position to be absolutely correct, it makes sense to take into account the lens’s imperfections to obtain a probabilistic guess as to the object’s true position. For another example, it might be important to associate some sort of error distribution with each of the individual sensors in an array of magnetometers. This error distribution may be complex and include spatially-driven covariances, because errors in nearby sensors are likely to be correlated (caused, for example, by the presence of some nearby, fixed metal object). This project is concerned with the design and implementation of a prototype data management system called the Monte Carlo Database System, or MCDB for short. MCDB allows an expert-level analyst or statistician to attach arbitrary stochastic models to very large data sets in order to “guess” the values for unknown or inaccurate data, such as the actual position of the observed object in the lens example above. When the resulting data set is analyzed, the underlying stochastic models are used to generate hundreds or thousands of possible data set instances, and each of those possible instances is analyzed separately by MCDB. Thus, MCDB does not just give a single answer to the analysis, but it actually gives an empirical distribution of query results that embody the underlying uncertainty, and can in turn be analyzed using standard statistical techniques. The stochastic models in MCDB are implemented as user-defined, external C++ libraries called Variable Generation functions (VG functions for short). Because the VG function interface is exceedingly general, it allows MCDB to be used in a very wide variety of application domains, in conjunction with virtually any stochastic model. Ultimately, we ended up calling the system that we developed over the course of the project SimSQL, to denote the fact that it allowed for stochastic simulation of data. The software developed during the lifetime of the project is available for download from the SimSQL project website: http://cmj4.web.rice.edu/SimSQL/SimSQL.html.

42 ENGINEERING↗

P13631-E002PF: Pulsed field magnetostriction of Ba 2 CoTeO 6

Ba 2 CoTeO 6 is an insulating material consisting of two magnetic subsystems referred as A and B build of S=1/2 spins. Subsystem A is considered to be a Heisenberg-like antiferromagnet (AFM) on a triangular lattice and subsystem B is a J 1 -J 2 Ising-like AFM on a honey-comb lattice. The magnetic phase transitions are observed at T N1 = 12 K and T N2 =3K for A and B respectively. The application of magnetic fields unveils a rich phase diagram that varies depending on the direction of the applied field for either H ll c or H perp c. To date the phase diagram has been investigated by means of specific heat measurement up to 9T and susceptibility measurements with a SQUID magnetometer up to 7T. Magnetization measured in pulsed magnetic fields up to 60T at 1.3K and 4.2K reveal several steps and plateaux occurring at varying critical fields depending on the crystallographic direction. Common to the magnetization parallel c and perpendicular c is the saturation above 40T.

36 MATERIALS SCIENCE↗

Effects of EMF Emissions from Cables and Junction Boxes on Marine Species

Studies have shown that diverse aquatic species are electrosensitive. Many fishes, and marine mammals, can either detect, navigate by, or are affected by electromagnetic fields (EMF) with various sensitivities, and their behavior may be impacted by unnatural EMF emissions in the water column. Sharks, rays and skates are known to have the highest sensitivity to electric fields. Electric field emissions in the range 0.5–100 micro volt/m appear to attract them, and emissions over 100 micro volt/m to repulse them. A marine hydrokinetic MHK device will have multiple components and associated multiple submarine cables on the seafloor and running through the water column and would potentially increase the level of EMF emissions to which the marine species at the site may be exposed to. There are therefore concerns amongst stakeholders that EMF emissions associated with MHK devices and their components may act as barriers to species migration, cause disorientation, change community compositions and ecosystems, and that they may attract sharks, leading to a local increase in the risk of shark attacks. However, field data to validate and model potential relationships between observed responses and the EMF emissions in situ are sparse. A program of experimental field surveys were conducted off the coast of South Florida, USA to characterize the electromagnetic field (EMF) emissions in the water column from a submarine cable, and to monitor for responses of local aquatic species. The field surveys were conducted at the South Florida Ocean Measurement Facility (SFOMF) off Fort Lauderdale, which is a cabled offshore in-water navy range. It consists of multiple active submarine power cables and a number of junction boxes, with the capability to transmit AC/DC power at a range of strength and frequencies. The site includes significant marine life activities and community structure, including highly mobile species, such as sharks, stingrays, mammals and turtles. SFOMF therefore typifies a setting representative of an offshore location where a MHK device may be sited. Background electromagnetic field (EMF) levels and EMF emissions due to submarine cables were measured using a custom E-field sensor and a commercial magnetometer deployed from an autonomous underwater vehicle (AUV) at various fixed altitudes above the seafloor. EMF signatures detected from power cables and junction boxes are contrasted against ambient background levels and other EMF sources. The potential responses of local marine species were observed at selected representative locations using divers on SCUBA, complemented with fixed cameras on the sea bottom and by a set of video cameras mounted on the AUV. The objectives of the study were: 1) to characterize the EMF emission levels associated with submarine cables 2) to monitor potential responses of aquatic animals to the emissions and 3) to develop an associated database of field observations. As control, observations of EMF levels and in situ marine species were conducted with power in the cable turned off. Good quality measurements of EMF emissions were obtained using the mobile AUV platform and the data from the surveys were used to develop contour maps of the EMF levels in the water column above the live cable as well as to provide information about how the field decays away from the cable. The measurements show good agreement with theoretical models of the how EMF levels decay away from the cable in deep and shallow water environment. Electric fields in excess of 200µV/m were measured in the vicinity of the cable during the power on state. Quarterly surveys by SCUBA divers were conducted, using point and transect count methods, over a period of one year at three locations, one at a shallow site where the water depth is approximately 5m, and the other at the Barracuda Reef where the water depth is approximately 10m. The sampling results were analyzed to determine if the presence of an SFOMF generated EMF alters: (1) abundance, species richness, and assemblage structure of coral reef fishes, (2) the behavior of fishes including elasmobranchs, and (3) the distribution of marine turtles and mammals. Diver observations were also used in attempt to discern if there were any noticeable organismal responses during the transitional period between ambient OFF to energized AC or DC power states, and video footage was intended to augment the in-situ visual survey data and aid in interpretation of the results. Comparisons are provided between observation datasets between the three sites and between the point and transect count methods. Presence of several individual elasmobranch species, including sharks and stingrays, were recorded during the surveys. No apparent effect on richness could be discerned between the power on and off states. No apparent sudden animal movements were observed during transitions between power states.

16 TIDAL AND WAVE POWER↗

Assessment of Potential Impact of Electromagnetic Fields from Undersea Cable on Migratory Fish Behavior

The US Department of Energy and US Department of the Interior, Bureau of Ocean Energy Management commissioned this study to address the limited scientific data on the impacts of high voltage direct current cables on aquatic biota, in particular migratory species within the San Francisco Bay. Empirical evidence exists that marine animals perceive and orient to local distortions in the earth’s main geomagnetic field magnetic field. The electromagnetic fields (EMF) generated by the cables that carry electricity from hydrokinetic energy sources to shore-based power stations may produce similar local distortions in the earth’s main field. Concern exists that animals that migrate along the continental shelves might orient to the EMF from the cables, and move either inshore or offshore away from their normal path. The Trans Bay Cable (TBC) is a ±200-kilovolt (kV), 400 MW 85-km long High Voltage Direct Current (DC) buried transmission line linking Pittsburg, CA with San Francisco, CA (SF) through the San Francisco Bay. The study addresses the following specific questions based on measurements and projections of the EMF produced by an existing marine cable, the TBC, in San Francisco Bay. Specifically, does the presence of EMF from an operating power cable alter the behavior and path of bony fishes and sharks along a migratory corridor? Does the EMF from an operating power cable guide migratory movements or pose an obstacle to movement? To meet the main study objectives several activities needed to be carried out: 1) modeling of the magnetic fields produced by the TBC, 2) assessing the migratory impacts on Chinook salmon smolts (Oncorhynchus tshawytscha) and green sturgeon (Acipenser medirostris) as a result of local magnetic field distortions produced by bridge structures and 3) analyzing behavioral responses by migratory Chinook salmon and green sturgeon to a high-voltage power cable. To meet the first objective, magnetic field measurements were made using two submerged Geometrics magnetometers towed behind a survey vessel in four locations in the San Francisco estuary along profiles crossing the cable path. We applied basic formulas to describe magnetic field from a DC cable summed vectorially with the background geomagnetic field (in the absence of other sources that would perturb the ambient field) to derive characteristics of the cable not immediately or otherwise observable. The magnetic field profiles of 76 survey lines were regressed against the measured fields, representing eight days of measurement. Many profiles were dominated by field distortions caused by bridge structures or other submerged objects, and the cable contribution to the field was not detectable. The regressions based on fundamental principles (Biot Savart law) and the vectorial summation of cable and geomagnetic fields provide estimates of cable characteristics consistent with plausible expectations. For the second objective, detailed gradiometer survey were examined. Distortions in the earth’s main field produced by bridges across the estuary were much greater than those from the TBC. The former anomalies exceeded the latter by an order of magnitude or more. Significant numbers of tagged Chinook salmon smolts migrated past bridges, which produced strong magnetic anomalies, to the Golden Gate Bridge, where they were recorded by dual arrays of acoustic tag-detecting monitors moored in lines across the mouth of the bay. Adult green sturgeon successfully swam upstream and downstream through the estuary on the way to and from their spawning grounds. Hence, the large anomalies produced by the bridges that run perpendicular to these migration routes do not appear to present a strong barrier to the natural seasonal movement patterns of salmonid smolts and adult green sturgeon. Finally, to assess the behavioral responses by migratory Chinook salmon and green sturgeon to a high- voltage power cable - the potential impacts effect of the TBC on fishes migrating through the San Francisco Estuary were examined. These included late-fall run Chinook salmon smolts (Oncorhynchus tshawytscha) that migrate downstream through the San Francisco Estuary to the Pacific Ocean and adult green sturgeon (Acipenser medirostris), which migrate upstream from the ocean through the estuary to their spawning habitat in the upper Sacramento River and return to the ocean after spawning occurs. Our results indicate Chinook salmon smolts may be attracted to the cable after activation (more cable location crossings, more detections at Bay Bridge, high importance of distance to cable in predicting fish location), but are not impeded from successfully migrating through the San Francisco Bay (similar proportions of successful exits, faster transit rates). Cable activity had opposite effects on outbound and inbound green sturgeon migrations: outbound migrations had significantly longer transit times while inbound migrations had significantly shorter migration times. However, the proportion of green sturgeon that successfully migrated through the San Francisco Bay was not strongly impacted after cable activation for either migration type. Based on the work, we provide the following conclusions: 1) calculations of magnetic fields for assessment of marine life can be performed; however, local anomalies in the fields resulting from submerged structures require validation of such calculations through collection of ambient DC magnetic field data, 2) the large anomalies produced by the bridges that run perpendicular to these migration routes do not appear to present a strong barrier to the natural seasonal movement patterns of salmonid smolts and adult green sturgeon and 3) Chinook salmon smolts may be attracted to the activated cable based on analysis of cable crossing, misdirections, and first presence at the array data, however, the cable activation does not appear to change the proportion of smolts that successfully migrate through the San Francisco Bay. Cable activation impacts inbound and outbound migrating adult green sturgeon: travel time was increased for outbound migrations but decreased for inbound migrations. However, cable activation did not appear to impact the success of either migration type in this species.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗