Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Iron nitride permanent magnet and technique for forming iron nitride permanent magnet

A permanent magnet may include a Fe 16 N 2 phase constitution. In some examples, the permanent magnet may be formed by a technique that includes straining an iron wire or sheet comprising at least one iron crystal in a direction substantially parallel to a <001> crystal axis of the iron crystal; nitridizing the iron wire or sheet to form a nitridized iron wire or sheet; annealing the nitridized iron wire or sheet to form a Fe 16 N 2 phase constitution in at least a portion of the nitridized iron wire or sheet; and pressing the nitridized iron wires and sheets to form bulk permanent magnet.

Wang, Jian-Ping↗

Magnetic Field Sensing via Optically Detected Magnetic Resonance and Spin Relaxometry Using Nitrogen Vacancies in Nanodiamonds

Quantum sensing is broadly defined as the use of quantum materials, quantum coherence, and/or quantum entanglement to measure physical quantities and/or to enhance the sensitivity of classical analytical measurements. Certain materials exhibit interesting quantum properties that have the potential to be utilized in quantum sensing applications. One such quantum property is electronic spin, which is utilized in this work. Here, we built a custom apparatus capable of conducting both optically detected magnetic resonance (ODMR) and spin relaxometry. The quantum material investigated was an ensemble of nitrogen vacancies (NV) in nanodiamonds. We have characterized the system and measured ODMR spectra for different strengths of the applied DC magnetic field and clearly observed the expected splitting of the resonances due to Zeeman splitting. We also have measured the spin relaxation times for two different powers of the applied AC magnetic field. The lower power dataset exhibited expected exponential temporal dependence of the relaxation of a modified spin state, whereas the higher power dataset exhibited stretched exponential dependence of the modified spin state, indicating the presence of high-power phenomena that emerge that retard the relaxation of the spin state.

Lander, Gary↗

Effects of Fe and Co Co-doping on Structural, Magnetic, and Optical Properties of Ti{sub 0.9}Fe{sub 0.1−x}Co{sub x}O{sub 2} Magnetic Semiconductors

A series of six samples with a general formula Ti{sub 0.9}Fe{sub 0.1−x}Co{sub x}O{sub 2} (x = 0.0, 0.02, 0.04, 0.06, 0.08, and 0.1) has been synthesized by solid-state reaction method at annealing temperature of 1150 {sup ∘}C for 2 hours. The synthesized samples have been characterized by X-ray diffractometer, Raman spectroscopy, scanning electron microscopy, EDX, vibrating sample magnetometer, and ultraviolet-visible spectroscopy to investigate structural, defective, morphological, elemental, magnetic, and optical properties. Structural analysis revealed dominant structure of rutile with a minor peak of hematite and anatase. An intensity loss and peak broadening of TiO{sub 2} (rutile) vibration lines has been observed from Raman analysis. Magnetic characterization showed ferromagnetic behavior at room temperature. Optical characterization revealed blue shift in band gap energy with increasing amount of Co concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wave-Vector Filtering Effect in a Novel Magnetic Nanostructure with Zero Average Magnetic Field

We report a theoretical investigation on wave-vector filtering (WVF) effect in a magnetic nanostructure, which can be experimentally realized by depositing ferromagnetic (FM) stripes on the surface of GaAs/Al{sub x}Ga{sub 1-x}As heterostructure. An appreciable WVF effect appears in this nanosystem. The WVF efficiency is associated with structural parameters of magnetic nanostructure. Therefore, such a device can be employed as a momentum filter for nanoelectronics device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synthesis and Characterization of Hydrophobic Fe{sub 3}O{sub 4} Magnetic Nanoparticles with High Saturation Magnetization

A simple one-step solvothermal method is proposed to prepare hydrophobic Fe{sub 3}O{sub 4} nanoparticles (MNPs) using iron acetylacetonate (Fe(acac){sub 3}), oleylamine (OAm), and ethylene glycol (EG). X-ray powder diffraction, scanning electron microscope, infrared spectroscopy, transmission electron microscopy, X-ray photoelectron spectrometry, and vibrating sample magnetometer are used to characterize the structure, morphology, and properties of products. The testing results indicate that the as-synthesized products are spherical-like hydrophobic MNPs, superparamagnetic at room temperature, with a saturation magnetization up to 76.8 emu/g. The good hydrophobic property of MNPs is attributed to the coverage of oleylamine, without causing a remarkable loss of magnetic property. In addition, the influences of material ratio, aging time, oleic acid, and stearic acid used as additives are studied in our research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Simulations of magnetic field gradients due to micro-magnets on a triple quantum dot circuit

To quantify the effects of local magnetic fields on triple quantum dots, the Heisenberg Hamiltonian has been diagonalized for three electrons coupled via the exchange interaction. In particular, we have investigated different geometries of micro-magnets located on top of the triple dot in order to optimize the field gradient characteristics. In this paper, we focus on two geometries which are candidates for an addressable EDSR triple quantum dot device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A table-top, repetitive pulsed magnet for nonlinear and ultrafast spectroscopy in high magnetic fields up to 30 T

We have developed a mini-coil pulsed magnet system with direct optical access, ideally suited for nonlinear and ultrafast spectroscopy studies of materials in high magnetic fields up to 30 T. The apparatus consists of a small coil in a liquid nitrogen cryostat coupled with a helium flow cryostat to provide sample temperatures down to below 10 K. Direct optical access to the sample is achieved with the use of easily interchangeable windows separated by a short distance of ∼135 mm on either side of the coupled cryostats with numerical apertures of 0.20 and 0.03 for measurements employing the Faraday geometry. As a demonstration, we performed time-resolved and time-integrated photoluminescence measurements as well as transmission measurements on InGaAs quantum wells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partial homogeneity based high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

In nuclear magnetic resonance (NMR) technique, it is of great necessity and importance to obtain high-resolution spectra, especially under inhomogeneous magnetic fields. In this study, a method based on partial homogeneity is proposed for retrieving high-resolution one-dimensional NMR spectra under inhomogeneous fields. Signals from series of small voxels, which characterize high resolution due to small sizes, are recorded simultaneously. Then, an inhomogeneity correction algorithm is developed based on pattern recognition to correct the influence brought by field inhomogeneity automatically, thus yielding high-resolution information. Experiments on chemical solutions and fish spawn were carried out to demonstrate the performance of the proposed method. The proposed method serves as a single radiofrequency pulse high-resolution NMR spectroscopy under inhomogeneous fields and may provide an alternative of obtaining high-resolution spectra of in vivo living systems or chemical-reaction systems, where performances of conventional techniques are usually degenerated by field inhomogeneity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comparison of numerical simulations and analytical theory of the dynamics of interacting magnetic vortices

Magnetostatic interactions between vortices in closely spaced planar structures are important for applications including vortex-based magnonic crystals and spin torque oscillator networks. Analytical theories that include magnetostatic interaction effects have been proposed but have not yet been rigorously tested. Here, we compare micromagnetic simulations of the dynamics of magnetic vortices confined in three disks in an equilateral triangle configuration to analytical theories that include coupling. Micromagnetic simulations show that the magnetostatic coupling between the disks leads to splitting of the gyrotropic resonance into three modes and that the frequency splitting increases with decreasing separation. The temporal profiles of the magnetization depend on the vortex polarities and chiralities; however, the frequencies depend only on the polarity combinations and will fall into one of two categories: all polarities equal or one polarity opposite to the others, where the latter leads to a larger frequency splitting. Although the magnitude of the splitting observed in the simulations is larger than what is expected based on purely dipolar interactions, a simple analytical model that assumes dipole-dipole coupling captures the functional form of the frequency splitting and the motion patterns just as well as more complex models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High sensitivity microwave detection using a magnetic tunnel junction in the absence of an external applied magnetic field

In the absence of any external applied magnetic field, we have found that a magnetic tunnel junction (MTJ) can produce a significant output direct voltage under microwave radiation at frequencies, which are far from the ferromagnetic resonance condition, and this voltage signal can be increase by at least an order of magnitude by applying a direct current bias. The enhancement of the microwave detection can be explained by the nonlinear resistance/conductance of the MTJs. Our estimation suggests that optimized MTJs should achieve sensitivities for non-resonant broadband microwave detection of about 5000 mV/mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methods of high current magnetic field generator for transcranial magnetic stimulation application

This paper describes the design procedures and underlying concepts of a novel High Current Magnetic Field Generator (HCMFG) with adjustable pulse width for transcranial magnetic stimulation applications. This is achieved by utilizing two different switching devices, the MOSFET and insulated gate bipolar transistor (IGBT). Results indicate that currents as high as ±1200 A can be generated with inputs of +/−20 V. Special attention to tradeoffs between field generators utilizing IGBT circuits (HCMFG{sub 1}) and MOSFET circuits (HCMFG{sub 2}) was considered. The theory of operation, design, experimental results, and electronic setup are presented and analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualization and quantification of magnetic nanoparticles into vesicular systems by combined atomic and magnetic force microscopy

We report a phenomenological approach for the quantification of the diameter of magnetic nanoparticles (MNPs) incorporated in non-ionic surfactant vesicles (niosomes) using magnetic force microscopy (MFM). After a simple specimen preparation, i.e., by putting a drop of solution containing MNPs-loaded niosomes on flat substrates, topography and MFM phase images are collected. To attempt the quantification of the diameter of entrapped MNPs, the method is calibrated on the sole MNPs deposited on the same substrates by analyzing the MFM signal as a function of the MNP diameter (at fixed tip-sample distance) and of the tip-sample distance (for selected MNPs). After calibration, the effective diameter of the MNPs entrapped in some niosomes is quantitatively deduced from MFM images.

36 MATERIALS SCIENCE↗

Magnetized ICF implosions: non-axial magnetic field topologies

This paper explores four different magnetic field topologies for application to spherical inertial confinement fusion implosions: axial, mirror, cusp and closed field lines. A mirror field is found to enhance the impact of magnetization over an axial field; this is because the mirror field more closely follows the hot-spot surface. A cusp field, while simple to generate, is not found to have any benefits over the tried-and-tested axial field. Closed field lines are found to be of the greatest benefit to hot-spot performance, with the simulated design undergoing a 2× increase in ion temperature before α-heating is considered. The plasma properties of the simulation with closed field lines are radically different from the unmagnetized counterpart, with electron temperatures in excess of 100 keV, suggesting that a fundamental redesign of the capsule implosion is possible if this method is pursued.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EVIDENCE OF MAGNETIC FIELD SWITCH-OFF IN COLLISIONLESS MAGNETIC RECONNECTION

The long-term evolution of large domain particle-in-cell simulations of collisionless magnetic reconnection is investigated following observations that show two possible outcomes for collisionless reconnection: toward a Petschek-like configuration or toward multiple X points. In the present simulation, a mixed scenario develops. At earlier time, plasmoids are emitted, disrupting the formation of Petschek-like structures. Later, an almost stationary monster plasmoid forms, preventing the emission of other plasmoids. A situation reminiscent of Petschek’s switch-off then ensues. Switch-off is obtained through a slow shock/rotational discontinuity compound structure. Two external slow shocks (SS) located at the separatrices reduce the in-plane tangential component of the magnetic field, but not to zero. Two transitions reminiscent of rotational discontinuities (RD) in the internal part of the exhaust then perform the final switch-off. Both the SS and the RD are characterized through analysis of their Rankine–Hugoniot jump conditions. A moderate guide field is used to suppress the development of the firehose instability in the exhaust.

79 ASTRONOMY AND ASTROPHYSICS↗

Permanent Magnet Synchronous Condenser with Solid State Excitation

A synchronous condenser consists of a free-spinning wound-field synchronous generator and a field excitation controller. In this paper, we propose a synchronous generator that employs a permanent magnet synchronous generator (PMSG) instead of a wound-field machine. PMSGs have the advantages of higher efficiency and reliability. In the proposed configuration, the reactive power control is achieved by a voltage source converter connected in series with the PMSG and the grid. The converter varies the phase voltage of the PMSG so as to create the same effect of over or under excitation in a wound-field machine. The converter output voltage level controls the amount and the direction of the produced reactive power and the voltage's phase is kept in-phase with the grid voltage except a slight phase can be introduced so that some power can be drawn from the grid for maintaining the DC bus voltage level of the converter. Since the output voltage of the converter is only a fraction of the line voltage, its VA rating is only a fraction of the rating of the PMSG. The proposed scheme is shown to be effective by computer simulation.

17 WIND ENERGY↗