Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOADING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Hierarchical sulfur electrodes as a testing platform for understanding the high-loading capability of Li-S batteries

Lithium-sulfur (Li-S) batteries are considered as an attractive electrochemical energy storage system due to the high theoretical capacity of sulfur (1,675 mA h g -1 ). However, high-loading sulfur cathodes would need to be employed for the Li-S cells to be practical, but the resulting poor cell cyclability and severe electrode degradation hamper their development. Here in this paper, we present a hierarchical sulfur cathode as a testing platform for understanding the high-loading capability of Li-S batteries. The hierarchical cathode presents good electrochemical utilization of above 70%, stable cyclability for 500–1,000 cycles, and high sulfur loadings of 4.2–10.0 mg cm -2 . The exploration of the activation and the polysulfide-retention processes of the high-loading cathodes illustrates that the electrochemical stability mainly results from the stabilization of dissolved polysulfides within the cathode region as the electrochemically active catholyte. Therefore, the utilization of stabilized polysulfide migration might be a meaningful opportunity for designing high-loading cathodes and further improving their electrochemical stability and long-term cyclability.

25 ENERGY STORAGE↗

Extreme fast charge aging: Effect of electrode loading and NMC composition on inhomogeneous degradation in graphite bulk and electrode/electrolyte interface

Empowering extreme fast charging (XFC) requires a comprehensive understanding of its application with advanced anode and cathode materials in lithium-ion batteries. No report exists for the full extent of limitations for the anode with crosstalk effect from paired cathode as well as Li plating due to electrode loading under XFC. In this study, a combination of cell testing and multiple length characterization is used to investigate XFC aging mechanism in cells with a low loading of 1.5 mAh cm -2 and high loading of 2.5 mAh cm -2 for graphite (Gr)/Ni-rich LiNi x Mn y Co 1-x-y O 2 (NMCs). Operando XRD mappings show 1.5 mAh cm -2 loadings result in higher strain in graphite for all three cathode types. Among the three NMC cathodes, the graphite from NMC532 and NMC811 cells show comparable strain. Scanning electron microscopy (SEM) images show distinct differences between 6-C-charged anodes in two loadings. Significantly increased electrode thickness can be seen due to more damage in the graphite bulk and accumulation of the electrolyte decomposition products in electrode pores. X-ray photoelectron spectroscopy (XPS) reveals both cathode chemistry and Li plating influence the non-uniform SEI composition on graphite surface. We report higher Ni content in NMC811 promotes the higher levels of salt decomposition on the SEI and formation of higher mass of electrolyte aging products.

25 ENERGY STORAGE↗

Preparation of resveratrol-loaded nanoporous silica materials with different structures

Solid, nanoporous silica-based spherical mesoporous MCM-41 and KIL-2 with interparticle mesoporosity as well as nanosized zeolite BEA materials differing in morphology and pore size distribution, were used as carriers for the preparation of resveratrol-loaded delivery systems. Two preparation methods have been applied: (i) loading by mixing of resveratrol and mesoporous carrier in solid state and (ii) deposition in ethanol solution. The parent and the resveratrol loaded carriers were characterized by XRD, TEM, N2 physisorption, thermal analysis, and FT-IR spectroscopy. The influence of the support structure on the adsorption capacity and the release kinetics of this poorly soluble compound were investigated. Our results indicated that the chosen nanoporous silica supports are suitable for stabilization of trans-resveratrol and reveal controlled release and ability to protect the supported compound against degradation regardless of loading method. The solid-state dry mixing appears very effective for preparation of drug formulations composed of poorly soluble compound. - Graphical abstract: trans-Resveratrol was stabilized in the pores of BEA zeolite, MCM-41and KIL2 mesoporous silicas. - Highlights: • BEA, KIL-2 and MCM-41 materials were used as carriers for resveratrol loading. • Resveratrol encapsulation in ethanol solution and solid state procedure were applied. • The solid-state preparation appears very effective for stabilization of trans-resveratrol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and peferentially loading of nickel nanoparticle on CdS surface and its photocatalytic performance for hydrogen evolution under visible light

Graphical abstract: Ni nanoparticles were prepared via chemical reduction of aqueous NiCl{sub 2} by borohydride reducing agent in the presence of polyvinlylpyrolidone as a modifier to prevent fast growth of Ni crystals and their aggregation, and then preferentially deposited on (1 0 0), (0 0 2), and (1 0 1) crystal planes of CdS by photo-induced electrons while water splitting reaction occurred simultaneously. Resultant nickel nanoparticles have a size of about 3 nm, and contributes to decreasing the photoluminescence peak intensity of CdS, which means that nickel functions as the trapper of photo-generated electrons thereby quenching the photoluminescence of CdS. Therefore, nano-Ni/CdS photocatalyst with a Ni loading of 2.5% possesses the best visible-light catalytic activity for water splitting-hydrogen evolution and provides a hydrogen production rate of up to 9050 μmol h{sup −1} g{sup −1}, while it exhibits stabilized activity towards H{sub 2} evolution as well. - Highlights: • Ni nanoparticles are prepared by chemical reduction and then loaded on CdS surface by photo-reduction. • Non-noble metal Ni nanoparticles (size: about 3 nm) act as co-catalyst for photocatalytic H{sub 2} evolution. • Nano-Ni/CdS exhibits high activity (9050 μmol h{sup −1} g{sup −1}) and perfect stability. - Abstract: Ni nanoparticles were prepared via chemical reduction of NiCl{sub 2} by NaBH{sub 4} in the presence of polyvinlylpyrolidone (PVP), and loaded on the surface of CdS by photo-induced electrons while water splitting reaction occurred simultaneously. Resultant Ni/CdS was characterized by high-resolution transmission electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, ultraviolet–visible light diffuse reflectance spectrometry, and photoluminescence spectrometry. It was found that as-prepared Ni nanoparticles are about 3 nm, and preferentially deposited on (1 0 0), (0 0 2), and (1 0 1) crystal planes of CdS. Meanwhile, loading nickel decreases the photoluminescence intensity of CdS, which means nickel functions as the trapper of photo-generated electrons. Therefore, nano-Ni/CdS photocatalyst with a Ni loading of 2.5% possesses the best visible-light catalytic activity for water splitting-hydrogen evolution and provides a hydrogen production rate of up to 9050 μmol h{sup −1} g{sup −1}, while it exhibits stabilized activity towards H{sub 2} evolution as well.

36 MATERIALS SCIENCE↗

Towards standardized nuclear reactors: Seismic isolation and the cost impact of the earthquake load case

We report nuclear energy has a key role to play in global decarbonization. Impediments to the widespread deployment of reactors are their projected high capital cost and levelized cost of energy, and time required to analyze, design, license, construct, and commission them. The earthquake load case is a key cost driver for a new build nuclear plant, because near-surface soils and seismic hazard are different at each site, requiring site-specific analysis, design, engineering, qualification, licensing, and regulatory review, essentially making every design First-of-a-Kind (FoaK). To enable deployment at the scale needed for deep decarbonization, the cost and time impact of the seismic load case must be significantly mitigated, and plants must be standardized. Seismic base isolation has been proven to considerably reduce the earthquake response of structures and equipment but has yet to be applied to a nuclear power plant in the United States, in part because the financial impacts, positive or negative, are not known. Because there are no recent non-proprietary data to characterize the influence of the seismic load case on capital cost, it is difficult to confidently quantify the financial benefits of seismic isolation. Scheme-level designs of two fundamentally different advanced reactor buildings were developed to assemble cost data on the influence of the seismic load case. Both buildings were equipped with three bespoke pieces of safety-related equipment and analyzed for incremented levels of earthquake shaking to quantify the seismic penalty on equipment, in terms of vessel weights and horizontal accelerations. Using analysis results, a questionnaire was developed and transmitted to nuclear utilities, reactor developers, engineers, and equipment suppliers to collect cost data on engineering and fabrication costs for these unique pieces of safety-class equipment. Synthesis of the cost data showed that the seismic load case significantly affects the capital cost (sum of engineering and fabrication cost) of safety-class equipment, with engineering costs being comparable to fabrication costs. Standardization of safety-class equipment is made possible by seismic isolation, that is, equipment designed for minimal seismic robustness can resist earthquake shaking at a site of much higher seismic hazard. The average reduction in the capital cost of the safety-related equipment, enabled by seismic isolation, is a factor of two for FoaK equipment and a factor of five for standardized equipment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading

Highlights: • A large centrifuge model of a geomembrane-lined landfill was seismically loaded. • The scaled peak acceleration of the strongest input motion was 0.6 g. • Laboratory testing was conducted to obtain properties of the model materials. • Collected data included liner strains due to downdrag and seismic loading. • Results show that settlement and seismic loading can potentially damage geomembranes. • Results can be used to validate numerical models for geomembrane performance. •The laboratory and centrifuge testing data is publicly available. - Abstract: A large scale centrifuge test of a geomembrane-lined landfill subject to waste settlement and seismic loading was conducted to help validate a numerical model for performance based design of geomembrane liner systems. The test was conducted using the 240 g-ton centrifuge at the University of California at Davis under the U.S. National Science Foundation Network for Earthquake Engineering Simulation Research (NEESR) program. A 0.05 mm thin film membrane was used to model the liner. The waste was modeled using a peat-sand mixture. The side slope membrane was underlain by lubricated low density polyethylene to maximize the difference between the interface shear strength on the top and bottom of the geomembrane and the induced tension in it. Instrumentation included thin film strain gages to monitor geomembrane strains and accelerometers to monitor seismic excitation. The model was subjected to an input design motion intended to simulate strong ground motion from the 1994 Hyogo-ken Nanbu earthquake. Results indicate that downdrag waste settlement and seismic loading together, and possibly each phenomenon individually, can induce potentially damaging tensile strains in geomembrane liners. The data collected from this test is publically available and can be used to validate numerical models for the performance of geomembrane liner systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlled Enzyme Cargo Loading in Engineered Bacterial Microcompartment Shells

Bacterial microcompartments (BMCs) are nanometer-scale organelles with a protein-based shell that serve to colocalize and encapsulate metabolic enzymes. They may provide a range of benefits to improve pathway catalysis, including substrate channeling and selective permeability. Several groups are working toward using BMC shells as a platform for enhancing engineered metabolic pathways. The microcompartment shell of Haliangium ochraceum (HO) has emerged as a versatile and modular shell system that can be expressed and assembled outside its native host and with non-native cargo. Further, the HO shell has been modified to use the engineered protein conjugation system SpyCatcher–SpyTag for non-native cargo loading. Here, we used a model enzyme, triose phosphate isomerase (Tpi), to study non-native cargo loading into four HO shell variants and begin to understand maximal shell loading levels. We also measured activity of Tpi encapsulated in the HO shell variants and found that activity was determined by the amount of cargo loaded and was not strongly impacted by the predicted permeability of the shell variant to large molecules. All shell variants tested could be used to generate active, Tpi-loaded versions, but the simplest variants assembled most robustly. We propose that the simple variant is the most promising for continued development as a metabolic engineering platform.

59 BASIC BIOLOGICAL SCIENCES↗

Supported Oxygen Evolution Catalysts by Design: Toward Lower Precious Metal Loading and Improved Conductivity in Proton Exchange Membrane Water Electrolyzers

Reducing the precious metal content of water oxidation catalysts for proton-exchange-membrane water electrolyzers remains a critical barrier to their large-scale deployment. Herein, we present an engineered architecture for supported iridium catalysts, which enables decreased precious metal content and improved activity and conductivity. The improvement in performance at lower precious metal loading is realized by the deposition of a conformal layer of platinum nanoparticles on titanium dioxide (TiO 2 ) using a facile photoreduction method to prepare conductive layer coated supports (CCSs). Platinum nanoparticles are homogeneously dispersed on TiO 2 , and the conductivity of the subsequent catalysts with 39 wt % precious group metal loadings is significantly higher than the commercial 75 wt % loaded IrO 2 -TiO 2 catalysts. The conformal conductive layer also maintains an enhanced conductivity and electrochemical activity upon thermal annealing when compared to catalysts without the conductive layer and nonconformal heterogeneous conductive layer. The iridium mass activity from half-cell studies shows a 141% improvement for CCS supported catalysts at 42% lower loadings compared to the commercial catalysts. The conductive layer also improves the single cell electrolyzer performance at a similar catalyst loading in comparison to a commercial state-of-the-art catalyst. Here, we correlate the physical properties of the engineered catalysts with their electrochemical performance in electrolyzers to understand structure-activity relationships, and we anticipate further performance improvements upon synthesis and materials optimizations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operando neutron imaging-guided gradient design of Li-ion solid conductor for high-mass-loading cathodes

High-mass-loading cathodes are crucial for achieving high energy density in all-solid-state batteries from the lab scale to industry. However, as mass-loading increases, electrochemical performance is significantly compromised due to sluggish kinetics. In this work, operando neutron imaging is deployed on a high-mass-loading NMC 811 cathode of 33 mg/cm 2 (5.0 mAh/cm 2 ) and directly visualizes the lithiation prioritization of the cathode active material (CAM) from the solid electrolyte membrane side to the current collector side. In addition to the tortuosity, another key limitation on ion transfer in the cathode arises from the mismatch between the uniform distribution of the solid electrolyte (catholyte) in the conventional composite cathode and the non-uniform Li + flux generated by the faradaic reaction of CAMs. Therefore, we engineer a gradient in the catholyte concentration to match the Li + flux distribution as a means of eliminating the ion transfer obstacle. This approach demonstrates enhanced rate performance, even with high-mass-loading cathodes. A LiCoO 2 composite cathode with 100 mg/cm 2 high-mass-loading exhibits an areal capacity of 10.4 mAh/cm 2 at a current density of 2.25 mA/cm 2 . This work provides insight into the ion-transport limitation in thick cathodes and demonstrates an effective gradient design to overcome the kinetic barrier and achieve high battery performance.

Batteries↗

A Separation Voltage Polarity Switching Method for Higher Sample Loading Capacity and Better Separation Resolution in Transient Capillary Isotachophoresis Separation

A separation voltage polarity switching transient capillary isotachophoresis (PS-tCITP) was developed to overcome a major sample loading volume limitation in transient capillary isotachophoresis (tCITP). The fundamental idea of PS-tCITP is to let sample ions move back and forth in the separation capillary during their initial isotachophoresis focusing stage by switching the polarity of separation voltage, in order to both increase the sample loading volume and improve the separation efficiency as compared to the conventional tCITP method. The experimental evaluation of the novel PS-tCITP method by using two peptide standards at 2 µM concentration showed that the maximum sample loading volume could be increased from 45% of the total separation capillary volume in tCITP to 70% in PS-tCITP, which resulted in a more than 1.5 fold increases in the peptide peak intensity at a given length/volume of the separation capillary. Due to the consecutive focusing of sample volume from each polarity switching of separation voltage, the separation time window at a given sample loading volume was also increased significantly in PS-tCITP as compared to tCITP. Experiment comparison between tCITP and PS-tCITP at 45% sample loading volume using the same setup showed that the migration time difference between the two peptide peaks increased from 0.3 min in tCITP to 0.363 min in PS-tCITP with similar peak widths and heights, resulting in roughly a 21% improvement in separation resolution. The performance advantages of PS-tCITP separation over tCITP separation was further verified by using a mixture of six peptide standards.

Wu, Huanming↗

Study of beam loading and its compensation in the Compact Ultrafast Terahertz Free-Electron Laser injector linac

The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic load balance scheme for the DSMC algorithm

The direct simulation Monte Carlo (DSMC) algorithm, devised by Bird, has been used over a wide range of various rarified flow problems in the past 40 years. While the DSMC is suitable for the parallel implementation on powerful multi-processor architecture, it also introduces a large load imbalance across the processor array, even for small examples. The load imposed on a processor by a DSMC calculation is determined to a large extent by the total of simulator particles upon it. Since most flows are impulsively started with initial distribution of particles which is surely quite different from the steady state, the total of simulator particles will change dramatically. The load balance based upon an initial distribution of particles will break down as the steady state of flow is reached. The load imbalance and huge computational cost of DSMC has limited its application to rarefied or simple transitional flows. In this paper, by taking advantage of METIS, a software for partitioning unstructured graphs, and taking the total of simulator particles in each cell as a weight information, the repartitioning based upon the principle that each processor handles approximately the equal total of simulator particles has been achieved. The computation must pause several times to renew the total of simulator particles in each processor and repartition the whole domain again. Thus the load balance across the processors array holds in the duration of computation. The parallel efficiency can be improved effectively. The benchmark solution of a cylinder submerged in hypersonic flow has been simulated numerically. Besides, hypersonic flow past around a complex wing-body configuration has also been simulated. The results have displayed that, for both of cases, the computational time can be reduced by about 50%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental characterization and constitutive modeling of the mechanical behavior of molybdenum under electromagnetically applied compression-shear ramp loading

Magnetically applied pressure-shear (MAPS) is a new experimental technique that provides a platform for direct measurement of material strength at extreme pressures. The technique employs an imposed quasi-static magnetic field and a pulsed power generator that produces an intense current on a planar driver panel, which in turn generates high amplitude magnetically induced longitudinal compression and transverse shear waves into a planar sample mounted on the drive panel. In order to apply sufficiently high shear traction to the test sample, a high strength material must be used for the drive panel. Molybdenum is a potential driver material for the MAPS experiment because of its high yield strength and sufficient electrical conductivity. To properly interpret the results and gain useful information from the experiments, it is critical to have a good understanding and a predictive capability of the mechanical response of the driver. In this work, the inelastic behavior of molybdenum under uniaxial compression and biaxial compression-shear ramp loading conditions is experimentally characterized. It is observed that an imposed uniaxial magnetic field ramped to approximately 10 T through a period of approximately 2500 μs and held near the peak for about 250 μs before being tested appears to anneal the molybdenum panel. In order to provide a physical basis for model development, a general theoretical framework that incorporates electromagnetic loading and the coupling between the imposed field and the inelasticity of molybdenum was developed. Based on this framework, a multi-axial continuum model for molybdenum under electromagnetic loading is presented. The model reasonably captures all of the material characteristics displayed by the experimental data obtained from various experimental configurations. Additionally, data generated from shear loading provide invaluable information not only for validating but also for guiding the development of the material model for multiaxial loadings.

36 MATERIALS SCIENCE↗

Numerical characterization of quasi-steady thermal load for thin crystal at cryogenic temperature with nondiffusive heat transfer

With dramatically improved brightness and repetition rate, the thermal load for crystal optics in x-ray free-electron laser applications has also significantly increased. To mitigate the thermal load, one effective method is cryogenic cooling. However, the emerging nondiffusive heat transfer phenomenon at cryogenic temperature may cause design failure if overlooked. To evaluate the optical performance of thin crystal optics under thermal load at cryogenic temperature, an integrated numerical tool is presented and applied to characterize the thermal load on thin crystals with nondiffusive phenomena accounted. Significant thermally induced distortion of the rocking curve is observed from numerical simulation, leading to potential seed power reduction in hard x-ray self-seeding application. Cryogenic cooling is confirmed necessary by simulation to handle the thermal load at high repetition rate operation.

42 ENGINEERING↗

Impact of power flow on Z-pinch loads

Magnetically insulated transmission lines (MITLs) are used to deliver tens of MA to a Z-pinch load. The MITLs suffer current losses due to contaminant plasma located in the anode–cathode gap which is swept toward the load along the power flow. The swept up contaminant plasma can deposit mass and energy onto the load resulting in deformations or the seeding of macroscopic instabilities. This paper discusses 2D fully kinetic simulations of the contaminant plasma evolution which predict the current losses and the flux of mass and energy onto the load. Furthermore, the effects of a dynamic, i.e., imploding, load are shown to increase both the current loss and the mass and energy flux. The MITL used is a conical, radially converging design which is a feature common to MA-scale Z-pinch accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structural mechanism of helicase loading onto replication origin DNA by ORC-Cdc6

Significance The loading of the core Mcm2-7 helicase onto origin DNA is essential for the formation of replication forks and genomic stability. Here, we report two cryo-electron microscopy (cryo-EM) structures that capture helicase loader–helicase complexes just prior to DNA insertion. These pre-loading structures, combined with a computational simulation of the dynamic transition from the pre-loading state to the loaded state, provide crucial insights into the mechanism required for topologically linking the helicase to DNA. The helicase loading system is highly conserved from yeast to human, which means that the molecular principles described here for the yeast system are likely applicable to the human system.

59 BASIC BIOLOGICAL SCIENCES↗

Fluid temperature predictions of geothermal borefields using load estimations via state observers

Fluid temperature predictions of geothermal borefields usually involves temporal superposition of its characteristic g-function, using load aggregation schemes to reduce computational times. Assuming that the ground has linear properties, it can be modeled as a linear state space system where the states are the aggregated loads. However, the application and accuracy of these models is compromised when the borefield is already operating and its load history is not registered or there are gaps in the data. This paper assesses the performance of state observers to estimate the borefield load history and obtain accurate fluid predictions. Results show that both Time-Varying Kalman Filter (TVKF) and Moving Horizon Estimator (MHE) provide predictions with average and maximum errors below 0.1 $^\circ C$ and 1 $^\circ C$ respectively. MHE outperforms TVKF in terms of n-step ahead output predictions and load history profile at the expenses of about 5 times more computational time.

Figueroa, Iago C.↗

Metal-loaded organic scintillators for neutrino physics

Organic liquid scintillators are used in many neutrino physics experiments of the past and present. In particular for low energy neutrinos when realtime and energy information are required, liquid scintillators have several advantages compared to other technologies. In many cases the organic liquid needs to be loaded with metal to enhance the neutrino signal over background events. Several metal loaded scintillators of the past suffered from chemical and optical instabilities, limiting the performance of these neutrino detectors. Different ways of metal loading are described in the article with a focus on recent techniques providing metal loaded scintillators that can be used under stable conditions for many years even in ton scale experiments. Lastly, we review applications of metal loaded scintillators in neutrino experiments and compare the performance as well as the prospects of different scintillator types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗