Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Integrated energy system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

An Advanced Cooling Device for Concentrated Photovoltaic Systems

Concentrated photovoltaics (CPV) have the potential to significantly enhance the energy conversion utilization of solar panels and reduce solar generation costs, making them a crucial area of advancement in solar power generation technology. However, the concentration of sunlight can lead to overheating of solar panels, resulting in a notable reduction in both the efficiency of solar power generation and the lifespan of the panels. This challenge remains the predominant technical hurdle that hinders the application of concentrated photovoltaic power generation technology. In this study, we propose a new cooling method for concentrated photovoltaic power generation systems via an integrated approach of incorporating Phase-Change Thermal Storage (PCTS) and Thermoelectric Generator (TEG) technology. This new method not only enhances the overall system's electricity generation efficiency but also effectively resolves the technical challenge of concentrated photovoltaic panel overheating issues, ensuring the continuity of concentrated photovoltaic power generation and extending the lifespan of solar panels and their components. In order to make full use of the wasted heat generated by photovoltaic power generation and effectively improve the power generation efficiency of the system, this work developed a phase change heat storage device based on a phase change material. This device uses the temperature difference between day and night to recover wasted heat from photovoltaic power generation. Through integration with the thermoelectric power generation system, thermal energy can be converted into electrical energy. In addition, the Peltier effect of thermoelectric materials is used to construct a photovoltaic panel overheating protection system, which significantly improves the reliability and service life of the system.

Gou, Yimeng↗

Spaced out: An economic framework to explore the impacts of PV panel spacing on large-scale farming in Colorado

CONTEXT Agrivoltaic systems co-locate solar technologies with agricultural operations on an integrated plot of land and potentially provide benefits to both energy and agricultural systems. To date, large-scale (>5-MW) agrivoltaic projects in the United States have been limited to grazing and ecovoltaic applications, raising questions about the impact and scalability of agrivoltaic crop systems. Many agrivoltaic designs raise the height of the solar panels to accommodate agricultural practices while keeping energy density high. However, raising the panels results in increased photovoltaic (PV) development costs, which often are higher than the economic returns of crop production underneath the panels. This leads to unfavorable project economics and the need for other agrivoltaic solutions than raising panels. OBJECTIVE To explore other solutions, we perform an initial feasibility analysis for an agrivoltaic solution that can integrate with large-scale farming practices by increasing the row spacing in between panels. Increased PV row spacing is a low-cost approach for scaling agrivoltaics to accommodate crop production and this spacing can be tailored to required crop equipment for different regions. Increasing row spacing will reduce the power density (PV installed per acre), but in areas that are not land limited, these agrivoltaic designs could be economically feasible. Our analysis establishes a framework for a feasibility analysis for where and with what crops spaced out panel agrivoltaic solutions might be economical. METHODS Using a case study for large-scale agriculture crops in Colorado, we establish a framework for wide-row agrivoltaic economic feasibility analysis. We utilized the System Advisor Model to calculate technoeconomic metrics to compare different row spacing solutions and capture tradeoffs of these system designs. RESULTS AND CONCLUSIONS We find that, in some circumstances, wider row agrivoltaic solutions that allow for continued mechanized crop production can provide economic benefits over a traditional utility-scale PV system. For most crops examined in this analysis, roughly $\$$200/acre in agricultural profit justified spacing out the panels to at least 31.7 ft. to accommodate agrivoltaic configurations versus PV only configurations. Additionally, opportunities for increased agricultural revenue with agrivoltaic systems allow PV project economics to tolerate a larger range of CAPEX variability while remaining economically viable relative to the PV only configurations. SIGNIFICANCE This framework can be adapted for a wide variety of crops and regions and allows for examination of economically favorable sites for future agrivoltaic systems that utilize different configuration and expand opportunities for agrivoltaics.

14 SOLAR ENERGY↗

Techno-Economic Assessment of Destabilized Li Hydride Systems for High Temperature Thermal Energy Storage

A comprehensive techno-economic analysis of destabilized Li hydrides, used as thermal energy storage systems in concentrating solar power plants, is presented and discussed. Two systems, operating at temperatures on the order of 550–650 °C, are selected as thermal energy storage units for steam power plants, namely the Si-destabilized Li hydride (LiSi) and the Al-destabilized Li hydride (LiAl). Two thermal energy storage systems, operating at temperatures on the order of 700–750 °C, are selected for integration in supercritical CO2 power plants, namely the Si-destabilized Li hydride (LiSi) and the Sn-destabilized Li hydride (LiSn). Each storage system demonstrates excellent volumetric capacity, achieving values between 100 and 250 kWhth/m3. The LiSi-based thermal energy storage systems can be integrated with steam and supercritical CO2 plants at a specific cost between 107 US$/kWhth and 109 US$/kWhth, with potential to achieve costs on the order of 74 US$/kWhth under enhanced configurations and scenarios. The LiAl-based storage system has the highest potential for large scale applications. The specific cost of the LiAl system, integrated in solar steam power plants, is equal to approximately 74 US$/kWhth, with potential to reach values on the order of 51 US$/kWhth under enhanced performance configurations and scenarios.

Corgnale, Claudio↗

Cybersecurity Baselines for Electric Distribution Systems and DER

The National Association of Regulatory Utility Commissioners (NARUC) has partnered with the Department of Energy (DOE) to develop a set of cybersecurity baselines for electric distribution systems and the distributed energy resources (DERs) that connect to them. Cybersecurity is an integral underpinning of power system resilience, and this initiative builds on work that states have undertaken over the last decade to mitigate cybersecurity risk across their critical infrastructures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Operation of Energy Systems with Large Amounts of Variable Generation: IEA Wind TCP Task 25 (Final Summary Report)

This report summarizes findings on wind integration from the 17 countries or sponsors participating in the International Energy Agency Wind Technology Collaboration Program (IEA Wind TCP) Task 25 from 2006-2020. Both real experience and studies are reported. Many wind integration studies incorporate solar energy, and most of the results discussed here are valid for other variable renewables in addition to wind. The national case studies address several impacts of wind power on electric power systems. In this report, they are grouped under long-term planning issues and short-term operational impacts. Long-term planning issues include grid planning and capacity adequacy. Short-term operational impacts include reliability, stability, reserves, and maximizing the value of wind in operational timescales (balancing related issues). The first section presents the variability and uncertainty of power system-wide wind power, and the last section presents recent studies toward 100% shares of renewables. The appendix provides a summary of ongoing research in the national projects contributing to Task 25 for 2021-2024. The design and operation of power and energy systems is an evolving field. As ambitious targets toward net-zero carbon energy systems are announced globally, many scenarios are being made regarding how to reach these future decarbonized energy systems, most of them involving large amounts of variable renewables, mainly wind and solar energy. The secure operation of power systems is increasingly challenging, and the impacts of variable renewables, new electrification loads together with increased distribution system resources will lead to somewhat different challenges for different systems. Tools and methods to study future power and energy systems also need to evolve, and both short-term operational aspects (such as power system stability) and long-term aspects (such as resource adequacy) will probably see new paradigms of operation and design. The experience of operating and planning systems with large amounts of variable generation is accumulating, and research to tackle the challenges of inverter-based, nonsynchronous generation is on the way. Energy transition and digitalization also bring new flexibility opportunities, both short and long term.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Evaluation of Topology Optimization to Achieve Energy Savings at the Urban District Level: Preprint

Advanced district thermal energy systems have the potential to achieve significant energy savings and facilitate the integration of renewable thermal resources and waste heat, contributing to reductions in carbon emissions. Such systems, also known as fifth generation district heating and cooling (5GDHC) systems, circulate water at temperatures close to ambient, and leverage electrically-driven water-source heat pumps located at connected buildings to further temper the water. However, barriers exist to the adoption of 5GDHC systems, including the factorial growth in potential network configurations as a function of the number of considered buildings. Topology optimization, which seeks to answer the questions, “Which is the best subset of buildings, if any, to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?” can accelerate the adoption of 5GDHC systems. This study is part of an effort to develop a topology optimization framework for district thermal energy systems. In this study, a heuristic for one aspect of the topology optimization problem---the use of the minimal spanning tree network to connect a given set of buildings at the least life cycle cost---is validated.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Mitigating energy demand sector emissions: The integrated modelling perspective

Mitigating carbon emissions in the current energy system will require fundamental changes of both the energy supply and the energy demand sectors. Previous global model-based analyses, however, have focused mostly on energy supply transformations, while the energy demand sector changes are less well understood. In this study, this knowledge gap is addressed by analysing in detail the projected future energy demand projections, and the required demand-side changes to reach stringent mitigation targets using a suite of integrated assessment models. We examine industry, transport and buildings sector pathways across four models and three different reference scenarios from the Shared-Socioeconomic Pathway framework which is used as a set of common future perspectives by the climate research community. The demand side mitigation efforts are compared to a more detailed, sector-specific, technology-oriented assessments of abatement potential based on a literature review for the year 2030. The results indicate that strong emission growth in the industry and transport sector can be attributed to increasing final energy per capita and population growth. In the stringent mitigation scenarios energy efficiency, electrification and switching to low carbon fuel are all required in the short term. In the green growth SSP1 scenario the required emission reduction is significantly less than other scenarios showing that the demand growth and the technology development largely affects the sectors’ mitigation challenge. The technology assessment estimates that in particular in the transport and buildings sector there is a higher potential to reduce demand-side emissions through energy efficiency improvements than currently envisioned in the integrated assessment models.

Edelenbosch, Oreane Y.↗

Interdisciplinary Approaches to Cybervulnerability Impact Assessment for Energy Critical Infrastructure

As energy infrastructure becomes more interconnected, understanding cybersecurity risks to production systems requires integrating operational and computer security knowledge. We interviewed 18 experts working in the field of energy critical infrastructure to compare what information they find necessary to assess the impact of computer vulnerabilities on energy operational technology. These experts came from two groups: 1) computer security experts and 2) energy sector operations experts. We find that both groups responded similarly for general categories of information and displayed knowledge about both domains, perhaps due to their interdisciplinary work at the same organization. Yet, their discussion of each group’s domain-specific training, motivations, and limitations, as well as their suggestions for collaboration across domains, highlighted how these two groups can work together to help each other secure the energy grid. Our findings inform the development of interdisciplinary security approaches in critical-infrastructure contexts.

97 MATHEMATICS AND COMPUTING↗

Interdisciplinary Approaches to Cyber-vulnerability Impact Assessment for Energy Critical Infrastructure

As energy infrastructure becomes more interconnected, understanding cybersecurity risks to production systems requires integrating operational and computer security knowledge. We interviewed 18 experts working in the field of energy critical infrastructure to compare what information they find necessary to assess the impact of computer vulnerabilities on energy operational technology. These experts came from two groups: 1) computer security experts and 2) energy sector operations experts. We find that both groups responded similarly for general categories of information and displayed knowledge about both domains, perhaps due to their interdisciplinary work at the same organization. Yet, we found notable differences in the details of their responses and in their stated perceptions of each group’s approaches to impact assessment. Their suggestions for collaboration across domains highlighted how these two groups can work together to help each other secure the energy grid. Our findings inform the development of interdisciplinary security approaches in critical-infrastructure contexts.

97 MATHEMATICS AND COMPUTING↗

Repowering Coal Plants as Pumped Thermal Energy Storage

This conference presentation presents the results from a DOE FE funded study on the integration of a Malta Pumped Heat Energy Storage system with a retiring coal-fired power plant, and the economic benefits to the asset owner and the local community.

20 FOSSIL-FUELED POWER PLANTS↗

A Multi-Model, Multi-Scale Research Program in Stressors, Responses, and Coupled Systems Dynamics at the Energy-Water-Land Nexus and for Concentrated, Interdependent Infrastructures: Toward Next Generation Capabilities in Integrated Impacts, Adaptation, and Vulnerability (I-IAV) Modeling and a Community of Practice

The goal of this research program was to build a next generation integrated suite of science-driven modeling and analytic capabilities, and a more expanded and connected community of practice, for analyses of the stressors, impacts, adaptations and vulnerabilities of global and regional change. The emphasis was on understanding energy-water-land interactions and feedbacks and interdependent infrastructures at appropriate regional and temporal scales. Although the scope spans many complex facets of data, modeling, and analysis, as well as scales appropriate for integrated impacts and adaptation research, the focus of this effort was the development of multi-model, multi-scale capabilities spanning the domains of Multi-Sector Dynamics (MSD) models; Impact, Adaptation, and Vulnerability (IAV) models; and Earth System Models (ESMs).

54 ENVIRONMENTAL SCIENCES↗

Energy Storage in South Asia: Understanding the Role of Grid-Connected Energy Storage in South Asia’s Power Sector Transformation

During the last decade, the cost of energy storage technologies, primarily lithium-ion battery energy storage systems (BESS), has declined rapidly and is projected to decline further over the next decade. This study provides a first-of-its-kind assessment of cost-effective opportunities for grid-scale energy storage deployment in South Asia both in the near term and the long term, including a detailed analysis of energy storage drivers, potential barriers, and the role of energy storage in system operations. We conduct scenarios-based capacity expansion modeling to assess when, where and how much energy storage can be cost-effectively deployed in India through 2050. The analysis relies on state-of-the-art modeling approaches to uncover and compare the value streams of battery storage with different durations as well as pumped storage hydropower. We also run hourly simulations of system operations in 2030 and 2050 to understand how energy storage will be utilized by system operators to help integrate RE and reduce operating costs. For Bangladesh, Bhutan, and Nepal, we use operational simulations to explore how increasing deployment of energy storage can help optimize the use of domestic resources and cross-border electricity trade.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Modular, Crushed-Rock Thermal Energy Storage Pilot Design (Final Report)

The goal of this project was to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The completed effort included a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. For the feasibility study, the Brenmiller technology was designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) NGCC plant in Astoria, New York. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. The study also included a techno-economic evaluation of a 200 MWh commercial-scale demonstration. Prior to this project, EPRI had reviewed Brenmiller’s technology, which is being built to demonstrate bGen™ at 1.7 MWe on a solar plant (Rotem) and has been designed for an NGCC facility in Italy, assessing it at technology readiness level (TRL) 5. Brenmiller is also conducting a separate 1-MWth pilot with NYPA that pairs a bGen™ module with a microturbine for a combined-heat-and-power (CHP) application to improve efficiency and provide flexibility. The next-step pilot being designed as part of this project would represent a 5-fold increase in scale, versus Rotem, and would show the technology’s ability to provide effective and economical energy storage, bringing the technology to TRL 6. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. The main objective of the work completed by the Electric Power Research Institute, Inc. (EPRI), Brenmiller Energy (Brenmiller), New York Power Authority (NYPA), and United E&C (formerly AECOM) was to perform a Phase I feasibility study on the integration of a crushed-rock thermal energy storage (TES) with a fossil plant. Under this project, the EPRI-led team successfully completed a feasibility study to prepare for the potential future Phase II pre-front end engineering design (pre-FEED) to implement a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. Specific deliverables under this project included the Technology Maturation Plan, Conceptual Study, Techno-Economic Assessment, Technology Gap Assessment, Project Plan for Phase II (submitted as Phase II Renewal Application), Commercialization Plan, and the Final Report (this document). This Final Report includes a compilation of the various summary reports that were prepared during the 12-month schedule of the Phase I project execution under award DE-FE0032017.

03 NATURAL GAS↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗